• Title/Summary/Keyword: Cavity sensor

Search Result 146, Processing Time 0.035 seconds

MAXIZYMEs: Allosterically controllable ribozymes with biosensor functions

  • Kurata, Hiroyuki;Miyagishi, Makoto;Kuwabara, Tomoko;Warashina, Masaki;Taira, Kazunari
    • BMB Reports
    • /
    • v.33 no.5
    • /
    • pp.359-365
    • /
    • 2000
  • Ribozymes are catalytic RNAs that can cleave RNAs at specific sites, thus they have been employed to degrade a target mRNA in vivo. Development of allosterically controllable ribozymes is of great current interest, but it remained difficult to furnish such functions to ribozymes in cultured cells or in animals. Recently, we designed allosterically controllable ribozymes termed maxizymes, which have sensor arms that recognize target mRNA sequences and, in the presence of such target sequences only, they form a cavity that can capture catalytically indispensable $Mg^{2+}$ ions, cleaving the target. The maxizyme was applied to therapy for chronic myelogenous leukemia (CML). It cleaved specifically the chimeric BCR-ABL mRNA, which caused CML, without damaging the normal ABL or BCR mRNA in mammalian cells and also in mice, providing the first successful example for allosteric control of the activity of artificial ribozymes in vivo.

  • PDF

The Experimental Study on the Intraoral Pressure, Closure Duration, and Voice Onset Time(VOT) of Korean Stop Consonants (한국어 파열자음의 인두내압, 폐쇄기 및 Voice Onset Time(VOT)에 관한 실험적 연구)

  • 표화영;심현섭;박헌이;최재영;최성희;안성복;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.50-57
    • /
    • 1999
  • A study to get the data of normal stop consonants production as preliminary study for cleft palate patients was performed. Normal Korean native 21 speakers were pronounced $VCV(V=/a/,C=/P/,/{P^1}/,/P^h/,/t/,/{t^1}/,/{t^h}/,/k/,/{k^1}/,/{k^h}/)$ syllables with natural speech rate and intensity. With intrapharyngeal pressure waveforms by pressure sensor in oropharyngeal cavity, amplitude and time duration of intrapharyngeal pressure were analyzed, and with acoustic waveforms and spectrograms, closure duration and VOT were analyzed. As results, the highest amplitude of intrapharyngeal pressure showed in alveolars and heavily aspirated consonants. Velars and unaspirated consonants were higher than bilabials and slightly aspirated ones each, in intrapharyngeal pressure. Bilabilas, alveolars and velars showed similar rise time of intrapharyngeal pressure build-up, but in decay time and total duration time, bilabials were slightly shorter than alveolars and velars, with no statistic significance. In the aspects of tensity, unaspirated consonants showed the longest rise time, heavily aspirated, the second, and slightly aspirated consonants, the shortest, which were also seen in decay time and total duration time. In closure duration, slightly aspirated consonants had the shortest closure duration, and the heavily aspirated ones, the second, and unaspirated consonants showed the longest. In VOT, heavily aspirated consonants showed the longest, slightly aspirated ones, the second and unaspirated ones showed the shortest.

  • PDF

The RLG's Power Supply Design for Attitude Control in the Satellite (저궤도 위성 자세제어용 센서 RLG 전원 공급기 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1488-1490
    • /
    • 2008
  • The gyroscope is the sensor for detecting the rotation in inertial reference frame and constitute the navigation system together an accelerometer. As the inertial reference equipment for attitude determination and control in the satellite, the mechanical gyroscope has been used but it bring the disturbance for mass unbalance so the disturbance give a bad influence to the observation satellite mission because the mechanical gyroscope has the rotation parts. During the launch, The mechanical gyroscope is weak in vibration, shock and has the defect of narrow operating temperature range so it need the special design in integration. Recently the low orbit observation satellite for seeking the high pointing accuracy of image camera payload accept the FOG(Fiber Optic Gyro) or RLG(Ring Laser Gyro) for the attitude determination and control. The Ring Laser Gyro makes use of the Sanac effect within a resonant ring cavity of a He-Ne laser and has more accuracy than the other gyros. It need the 1000V DC to create the He-Ne plasma in discharge tube. In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply(HVPS) is proposed. Also, The analysis of flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design and voltage doubler circuit.

  • PDF

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

A Self-Oscillation Type SAW Microgyroscope Based on the Coriolis Effect of Progressive Waves (진행파의 코리올리효과를 이용한 자가발진형 표면탄성파 초소형 자이로스코프)

  • Oh, Hae-Kwan;Choi, Ki-Sun;Lee, Hyung-Keun;Lee, Kee-Keun;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.390-396
    • /
    • 2010
  • An 80MHz surface acoustic wave (SAW)-based gyroscope utilizing a progressive wave was developed on a piezoelectric substrate. The developed sensor consists of two SAW oscillators in which one is used for sensing element and has metallic dots in the cavity between input and output IDTs. The other is used for a reference element. Coupling of mode (COM) modeling was conducted to determine the optimal device parameters prior to fabrication. According to the simulation results, the device was fabricated and then measured on a rate table. When the device was subjected to an angular rotation, oscillation frequency differences between the two oscillators were observed because of the Coriolis force acting on the metallic dots. Depending on the angular rate, the difference of the oscillation frequency was modulated. The obtained sensitivity was approximately 52.35 Hz/deg.s within the angular rate range of 0~1000 deg/s. The performances of devices with three IDT structures for two kinds of piezoelectric substrates were characterized. Good thermal stability was also observed during the evaluation process.

Feasibility Study of the Application of Infinite Tube Probe in High Temperature Environment (고온 환경에서 무한 튜브 검출기의 적용에 관한 타당성 연구)

  • Kim, Hyeonjun;Ryu, Chulsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.108-119
    • /
    • 2020
  • Dynamic pressure sensor used in liquid rocket engine combustor and gas turbine is recess-mounted usually because it should work in high temperature environment. Although recess-mounted method can protect it from combustion gas in high temperature, tube resonance occurs in a tube-cavity system. To reduce it, the infinite tube probe(ITP) was introduced in this study. The ITP model suggested in previous literature was validated with experimental data and frequency response characteristics were analyzed. Guidelines for designing the ITP were suggested as frequency response profiles varied with geometric information and physical properties using this model.

Developement of Small 360° Oral Scanner Embedded Board for Image Processing (소형 360° 구강 스캐너 영상처리용 임베디드 보드 개발)

  • Ko, Tae-Young;Lee, Sun-Gu;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1214-1217
    • /
    • 2018
  • In this paper, we propose the development of a Small $360^{\circ}$ Oral Scanner embedded board. The proposed small $360^{\circ}$ oral scanner embedded board consists of image level and transfer method changing part FPGA part, memory part and FIFO to USB transfer part. The image level and transmission mode change unit divides the MIPI format oral image received through the small $360^{\circ}$ oral cavity image sensor and the image sensor into low power signal mode and high speed signal mode and distributes them to the port and transfers the level shift to the FPGA unit. The FPGA unit performs functions such as $360^{\circ}$ image distortion correction, image correction, image processing, and image compression. In the FIFO to USB transfer section, the RAW data transferred through the FIFO in the FPGA is transferred to the PC using USB 3.0, USB 3.1, etc. using the transceiver chip. In order to evaluate the efficiency of the proposed small $360^{\circ}$ oral scanner embedded board, it has been tested by an authorized testing institute. As a result, the frame rate per second is over 60 fps and the data transfer rate is 4.99 Gb/second

Laser-based THz Time-Domain Spectroscopy and Imaging Technology (레이저 기반 테라헤르츠 시간영역 분광 및 영상 기술)

  • Kang, Kwang-Yong;Kwon, Bong-Joon;Paek, Mun Cheol;Kang, Kyeong Kon;Cho, Suyoung;Kim, Jangsun;Lee, Senung-Churl;Lee, Dae-sung
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.317-327
    • /
    • 2018
  • Terahertz (THz) time-domain spectroscopy(TDS), imaging techniques, and related systems have become mature technologies, widely used in many universities and research laboratories. However, the development of creative technologies still requires improved THz application systems. A few key points are discussed, including the innovative advances of mode-locking energy-emitting semiconductor lasers and better photoconductive semiconductor quantum structures. To realize a compact, low cost, and high performance THz system, it is essential that THz spectroscopy and imaging technologies are better characterized by semiconductor and nano-devices, both static and time-resolved. We introduce the THz spectroscopy and imaging systems, the OSCAT(Optical Sampling by laser CAvity Tuning) system and the ASOPS(ASynchronous Optical Sampling) system, are constructed by our research team. We report on the THz images obtained from their use.

Optical Resonance-based Three Dimensional Sensing Device and its Signal Processing (광공진 현상을 이용한 입체 영상센서 및 신호처리 기법)

  • Park, Yong-Hwa;You, Jang-Woo;Park, Chang-Young;Yoon, Heesun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.763-764
    • /
    • 2013
  • A three-dimensional image capturing device and its signal processing algorithm and apparatus are presented. Three dimensional information is one of emerging differentiators that provides consumers with more realistic and immersive experiences in user interface, game, 3D-virtual reality, and 3D display. It has the depth information of a scene together with conventional color image so that full-information of real life that human eyes experience can be captured, recorded and reproduced. 20 Mega-Hertz-switching high speed image shutter device for 3D image capturing and its application to system prototype are presented[1,2]. For 3D image capturing, the system utilizes Time-of-Flight (TOF) principle by means of 20MHz high-speed micro-optical image modulator, so called 'optical resonator'. The high speed image modulation is obtained using the electro-optic operation of the multi-layer stacked structure having diffractive mirrors and optical resonance cavity which maximizes the magnitude of optical modulation[3,4]. The optical resonator is specially designed and fabricated realizing low resistance-capacitance cell structures having small RC-time constant. The optical shutter is positioned in front of a standard high resolution CMOS image sensor and modulates the IR image reflected from the object to capture a depth image (Figure 1). Suggested novel optical resonator enables capturing of a full HD depth image with depth accuracy of mm-scale, which is the largest depth image resolution among the-state-of-the-arts, which have been limited up to VGA. The 3D camera prototype realizes color/depth concurrent sensing optical architecture to capture 14Mp color and full HD depth images, simultaneously (Figure 2,3). The resulting high definition color/depth image and its capturing device have crucial impact on 3D business eco-system in IT industry especially as 3D image sensing means in the fields of 3D camera, gesture recognition, user interface, and 3D display. This paper presents MEMS-based optical resonator design, fabrication, 3D camera system prototype and signal processing algorithms.

  • PDF

Development of Wideband Frequency Modulated Laser for High Resolution FMCW LiDAR Sensor (고분해능 FMCW LiDAR 센서 구성을 위한 광대역 주파수변조 레이저 개발)

  • Jong-Pil La;Ji-Eun Choi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1023-1030
    • /
    • 2023
  • FMCW LiDAR system with robust target detection capabilities even under adverse operating conditions such as snow, rain, and fog is addressed in this paper. Our focus is primarily on enhancing the performance of FMCW LiDAR by improving the characteristics of the frequency-modulated laser, which directly influence range resolution, coherence length, and maximum measurement range etc. of LiDAR. We describe the utilization of an unbalanced Mach-Zehnder laser interferometer to measure real-time changes of the lasing frequency and to correct frequency modulation errors through an optical phase-locked loop technique. To extend the coherence length of laser, we employ an extended-cavity laser diode as the laser source and implement a laser interferometer with an photonic integrated circuit for miniaturization of optical system. The developed FMCW LiDAR system exhibits a bandwidth of 10.045GHz and a remarkable distance resolution of 0.84mm.