• 제목/요약/키워드: Cavity length

검색결과 460건 처리시간 0.028초

$\lambda$/4 위상천이 DFB 레이저 다이도드에서 grating 구조상의 비이상성이 발진특성에 미치는 영향 (Effects of structural nonidealities on the lasing characteristics of $\lambda$/4 phase-shifted DFB lasers)

  • 조종섭;김상배
    • 전자공학회논문지A
    • /
    • 제33A권7호
    • /
    • pp.245-252
    • /
    • 1996
  • $\lambda$/4 phase-shifted DFB lasers with nonideal grating structure have been studied by using an effective-index transfer matrix method where material dispersion, vwaveguide dispersion and waveguide-structuredependent loss are taken into consideration. Nonideal grating structure in the center phase-shift region does not incur serous degradation of laser characteristics. Phase-shift error from the ideal shift of $\pi$ causes a decrease in the threshold gain difference and lasing wavelength shift and should be less than $\pi$/4 when residual facet reflectivity is 0.7%. also, positional error of the phase-shift should be less than 9% of the cavity length in order for the threshold gain difference to be decreased less than 10%.

  • PDF

열전 냉각기가 집적된 레이저 다이오드 (Design and Fabrication of Laser Diode Integrated with Peltier Cooler)

  • 이상일;박정호
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.159-165
    • /
    • 1995
  • A double-heterostructure mesa-stripe-geometry laser diode integrated with thermoelectric Peltier cooler has been designed and fabricated. Epi-layers have been grown by metal organic chemical vapor deposition(MOCVD) method. Peltier cooling effect has been measured for devices with a mesa width of 14$\mu$m and a cavity length of 380$\mu$m. The effects of thermoelectric cooling could be shown by measuring the optical output of the laser with the increase of the current in the thermoelectric cooler. While the input courrent of the laser was maintained at 250mA, the optical output was decreased from 4.8mW to 3.8mW due to heating, but with the thermoelectric cooler on the optical output power was recovered by more than 40%. The results show that the complicated cooling device is not needed since the cooling can be achevied by the developement of the fabrication processing.

  • PDF

2-종 모드 레이저를 이용한 고분해능 헤터로다인 간섭계 (A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser)

  • 김민석;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.214-219
    • /
    • 1997
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600-1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with aims to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial mode laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, whlch allows us to perform multiple measurements of up to 10 machine axes simultaneously.

  • PDF

다수캐비티 사출금형에서 엘라스토머 TPV의 충전 불균형 (Filling Imbalance of Elastomer TPVs in Injection Mold with Multi-Cavity)

  • 한동엽;권윤숙;노병수;정영득
    • 한국정밀공학회지
    • /
    • 제24권2호
    • /
    • pp.41-46
    • /
    • 2007
  • Recently, the study for filling imbalance in thermoplastic polymer has gradually been increased. However, it is hard to find the researches for filling imbalance of thermoplastic elastomer(TPE). The experiment of filling imbalance was conducted for the three kinds of thermoplastic vulcanizes(TPVs) in the mold with geometrically balanced runner system. In this experiment, the effects of the melt temperature and injection speed on the filling imbalance were investigated. To solve the filling imbalance, Runner Core pin(RC pin) in the experimental mold was adopted and it's effects was tested. In this paper, we present that the insert length of RC pin is dependent to each polymers for optimal filling balance.

디지털 호모다인 검출방식을 이용한 간섭형 광섬유센서의 신호처리 (Signal processing of interferometric fiber-optic sensor utilizing a digital homodyne detection)

  • 예윤해
    • 한국광학회지
    • /
    • 제6권1호
    • /
    • pp.62-69
    • /
    • 1995
  • 레이저 다이오드 구동 전류펄스기간의 발진주파수 변조와 간섭계 출력신호의 시간지연 샘플링을 이용하여 3x3 coupler등과 같은 특수 광부품을 사용하지 않고도 1개씩의 광원과 광검출기를 이용하여 측정신호의 변화방향과 함께 half fringe의 수를 count할 수 있으며 광연결선 주변환경의 변화에 의한 세기변화 에러도 피할 수 있는 간섭형 센서를 위한 새로운 신호처리방식을 제안하고 이 방식을 거울내장형 FP간섭계를 이용한 온도센서에 적용하였다. 온도센서소자로 cavity length가 1cm인 FP간섭계를 이용하여 실온에서 360.deg.C에 걸쳐 분해능 2.7.deg.C로 측정하였으며 이때 최대측정속도는 $ 1.378*10^{5}$.deg.C/sec로 계산되었다. 이 방식에서 분해능과 최대측정속도는 반비례 관계를 가지며 감지 광섬유의 길이에 비례하여 분해능을 높일 수 있다. 또한 6개까지의 센서소자를 한개의 광원과 광검출기로 모니터하는 다중화 센싱 또한 가능한 신호처리 방식으로써 불평형 간섭계를 이용한 모든 종류의 센서에 대해 적용이 가능하다.

  • PDF

Josephson plasma excitation in vortex states

  • Kadowaki, K.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.21-21
    • /
    • 2000
  • The Josephson Plasma resonance in single crystalling Bi2Sr2CaCu2O8 has been investigated at a microwave frequency of 35 GHz in a cavity resonator. A sharp resonance is observed in a perpendicular oscillating magnetic field. The former is independent of the sample dimension, shile the latter shift to higher field as the sample size L is reduced, and it disappears when L becomes smaller than the critical length. The longitudinal plasma mode is a Nambu-Goldston mode in a superconductor, the experimental distinction between the longitudinal and the transverse mode leads to the conclusion that the existence of the Nambu-Goldston mod as predicted by Anderson was experimentally confirmed by direct observation of the Josephson plasma resonance with longitudinal excitations. The finite gap found in Josephson plasma resonance also provides a direct proof of the Anderson-Higgs mechanism within the context of the spontaneously broken phase symmetry of the Gauge-field theory in a superconductor.

  • PDF

Conduits for Coronary Bypass: Arteries Other Than the Internal Thoracic Artery's

  • Barner, Hendrick B.
    • Journal of Chest Surgery
    • /
    • 제46권3호
    • /
    • pp.165-177
    • /
    • 2013
  • This is the third in a series on coronary artery bypass which reviews three alternative arterial conduits. The radial artery has become the most widely used of the three and accumulating experience demonstrates better patency at 10 years versus saphenous vein. Drawbacks are a long incision on the forearm, the propensity for spasm and persistent sensory disturbance in about 10%. The first is answered by endoscopic harvest which may yield a shorter conduit but reduces sensory nerve injury. Spasm is managed pharmacologically and by less harvest trauma. The gastroepiploic artery is used in situ and free and although the abdominal cavity is entered complications are minimal and patency compares favorably with the radial artery. Use of the inferior epigastric artery remains minimal and its similar length often requires composite use but limited patency data are supportive. Other arteries have had rare use and this is unlikely to change because the three presented here have significant advantages and acceptance.

변형된 TE$_{113}$/TM$_{012}$ 삼중모드 도파관 대역통과여파기의 구현 (Implementation of a modified TE$_{113}$/TM$_{012}$ triple-mode waveguide bandpass filter)

  • 정근욱;이재현;박광량;김재명
    • 전자공학회논문지A
    • /
    • 제33A권11호
    • /
    • pp.70-77
    • /
    • 1996
  • In this paper, a modifed TE$_{113}$/TM$_{012}$ triple-mode bandpass filter is implemented by using a modified inter-cavity iris in which the number of slots are reduced upto 50%. In a coventioanl iris two prirs of slot apertures are used to independently couple three resonant modes between two adjacent cavities. However, if transverse magnetic polarizability of a pair of veritcal slot apertures is used to control weak horizontal TE$_{h}$-TE$_{h}$ mode coupling, the width of novel iris slots would substitute for the slot length of the conventional iris, causing to eliminate the horizontal slot apertures. The measured data of two filters, which are the modified filter and ocnventional one, are compared. Experimental result shows that the characteristics of the novel triple-mode filter matches well that of the conventional filter.

  • PDF

이중 헤테로 접합 레이저 다이오드의 횡방향 도파 및 빔폭 변화에 관한 연구 (A Study on the Lateral Waveguiding & Beam Width Variation of DH Laser Diode)

  • 김은수;박한규
    • 대한전자공학회논문지
    • /
    • 제20권1호
    • /
    • pp.15-21
    • /
    • 1983
  • 본 논문에서는 스트라입 구조형 이중 헤테로 접합 레이저 다이오드의 횡방향 도파 기구에 대한 이론적 해석이 시도되었다. 해석 과정에서 이득 및 굴절율의 공간적 변화를 주입전류의 수학적 모델로 결정하고 섭동된 파동방정식에 의한 횡방향 도파 해석을 통해 빔폭의 활성층 두께 스트라입 폭 및 캐비티 길이 의존성을 분석하였다.

  • PDF

수중익의 표면거칠기가 캐비테이션 특성에 미치는 영향 (Effects of the Surface Roughness on the Characteristics of the Cavitation in a Hydrofoil)

  • 윤경종;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.456-461
    • /
    • 2004
  • In this study, the characteristics of the cavitation behavior around hydrofoil are investigated with the commercial CFD code CFX-5. Calculations are performed for NACA 64108 hydrofoil by solving the time-averaged turbulent Navier-Stokes equations and discretized by finite volume method. We classify the different cavitating regimes in which appear at the hydrofoil according to the values of cavitation number, surface roughness and angle of attack. Special attention is paid to the following topics: cavity length, void fraction and lift breakdown.

  • PDF