• Title/Summary/Keyword: Cause of fire

Search Result 821, Processing Time 0.025 seconds

Analysis of Forest Fires during Chosun Dynasty through Historical Literature Survey (역사문헌 고찰을 통한 조선시대 산불특성 분석)

  • Kim, Dong-Hyun;Kang, Young-Ho;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.8-21
    • /
    • 2011
  • This study surveyed historical records on outbreak and features of forest fires during Chosun Dynasty's 518 years in being and analyzed the Annals of the Chosun Dynasty; The Diaries of the Royal Secretariat, archives from Records of the Border Defense Council, The Compilation of Ministry Proposals, Posthumous Records of King Cholchong etc. Forest fires were most prevalent and extreme during King Hyunjong (14 cases) and King Sunjo (13 cases) due to strong wind, and the biggest-ever forest fire broke out in the fourth year of King Soonjo (1804) in the east coast of Korea in Kangwon province. The fire had resulted in 61 fatalities and 2,600 destroyed houses. Forest fire in the east coast of Korea, Kangwon province, in the $13^{th}$ year of King Hyeonjong (1672) is recorded to have caused the highest number of deaths, 65people. The most frequent cause of forest fires during Chosun Dynasty was unidentified (42 cases), followed by accidental fire (10 cases), arson or lightning (3 cases), fire during hunting (2 cases), play with fire by children, destruction of patty fields and dry fields by fire and house fire (1 case respectively). By region, 56 % of forest fires erupted in the east coast (39 cases) and this was followed by the west sea (9 cases), Seoul and central region (8 cases) and the southern part of Korea (7 cases). By season, spring was found to be most vulnerable to forest fire as it accounted for 73 % of the total amounting to 46 cases. Behind were summer (11 cases), winter (6 cases) and autumn (0 case). Specifically, most forest fire broke out on April and May, which is the same as today. Archives and literature indicate that the person who involved in forest fire by accidental as well as arson had to be punished by banishment, expulsion from government office and public hanging. Also, officials in charge of the region that suffered forest fire were subject to reprimand. In conclusion, risk and gravity of forest fires were evident during the Chosun Dynasty as specified in historical archives and share many similarities with today's forest fires in terms of the duration and regional patterns.

The Sophisticated Causes in the Phaedo (『파이돈』에서의 세련된 원인들)

  • Chun, Hunsang
    • Journal of Korean Philosophical Society
    • /
    • no.122
    • /
    • pp.1-23
    • /
    • 2018
  • In the final argument for the immortality of the soul in the Phaedo, Socrates establishes a new type of cause which he describes as 'more sophisticated' and on the basis of it attempts to show that the soul is immortal. In the process, he introduces three examples for the cause, i.e. three, fire, and snow. But there has been considerable controversy over the ontological status of the three and the soul. Some scholars think that they are all forms; others believe that neither of them is. In this paper I argue that in fact one of them is a form, while the others are not. I also argue that the fact that they do not have the same ontological status and the uncertainty in the nature of the soul itself weaken the cogency of the final argument as a whole.

A Research on the Shotcrete Tunnel Application to Concrete mixing PET Fiber (PET FIBER를 혼입한 콘크리트의 숏크리트 터널 적용에 관한 연구)

  • Kim, Joo-Seok;Yoo, Sang-Geon;Lee, Yong-Jun;Shin, Hyum-Seong;Kim, Eun-Kyum
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.928-934
    • /
    • 2008
  • Resently, Fiber Reinforced Concrete is used for not only preventing crack of concrete but also reinforcing general methods. Steel Fiber and PP(poly-propylene) Fiber are usually used as fiber reinforced materials. However, using these materials for shotcrete on Railway tunnel can cause some problems such as damage of pressure hose and shotcrete rebound. In addition, Steel fiber is an expensive material and it can cause safety problems during applying to shotcrete. PP Fiber can cause a problem in fiber balling during applying to shotcrete railway tunnel construction. A purpose of the research is applying a development of PET(Poly Etylene Terephtalate) fiber by recycling pet bottles to the shotcrete tunnel exposed to explosion spalling. To investigate the reinforcement effect of the PET fiber, some basic tests are accomplished to physical properties and explosion spalling by fire. As a result of the tests, a concrete mixing the PET fiber has stronger resistance effect in the explosion spalling by high temperature than another strong fiber concrete does, and that the former concrete is also equal or more effective on the result of the above tests to physical properties like compression and strain than the latter one is demonstrated.

  • PDF

Projecting forest fire potential in the Baekdudaegan of the Chungcheong region under the SSP scenario climate change using KBDI Drought Index (KBDI 가뭄지수를 이용한 SSP 기후변화 시나리오하의 충청지역 백두대간 산불 잠재력 전망)

  • Choi, Jaeyong;Kim, Su-Jin;Jung, Huicheul;Kim, Sung-Yeol;Moon, Geon-Soo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.6
    • /
    • pp.1-11
    • /
    • 2022
  • Recently, climate change has been regarded as a major cause of large-scale forest fires worldwide, and there is concern that more frequent and severe forest fires will occur due to the level of greenhouse gas emissions. In this study, the daily Keetch and Byram Drought Index (KBDI) of the Baekdudaegan in Chungcheong region including Sobaeksan, Songnisan, and Woraksan National Parks were calculated to assess effect of climate change on the forest fire potential- severity of annual maximum KBDI and frequency of high KBDI days. The present (2000~2019) and future KBDI(2021~2040, 2041~2060, 2081~2090) were calculated based on the meteorological observation and the ensemble regional climate model of the SSP1-2.6 and SSP5-8.5 scenarios with a spatial resolution of 1-km provided by Korea Meteorological Administration(KMA). Under the SSP5-8.5 scenario, 6.5℃ increase and 14% precipitation increase are expected at the end of the 21st century. The severity of maximum daily KBDI increases by 48% (+50mm), and the frequency of high KBDI days (> 100 KBDI) increases more than 100 days, which means the high potential for serious forest fires. The analysis results showed that Songnisan National Park has the highest potential for forest fire risk and will continue to be high in intensity and frequency in the future. It is expected that the forest vulnerability of the Baekdudaegan in the Chungcheong region will greatly increase and the difficulty in preventing and suppressing forest fires will increase as the abundance of combustible materials increases along with climate changes.

The main factor and counterplan for marine casualties of fishing vessel according to the type of fishing gear in Korea (업종별 어선 해양사고의 원인과 대책)

  • PARK, Byung-Soo;KANG, Il-Kwon;HAM, Sang-Jun;PARK, Chi-Wan;KIM, Su-Hyeong;CHO, Hyun-Kuk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.3
    • /
    • pp.232-240
    • /
    • 2016
  • Marine casualties originated from fishing vessels occupied about 71.2% of the whole marine casualties in Korea from 2008 to 2014, which has not changed much for a long time. Therefore, a pragmatic counterplan to decrease in casualties in fishing vessel is indispensable for reduction of marine casualties in Korea. Since the casualties occurred by fishing vessels may incline to a specific type of casualties according to the difference in the operating type; in this paper, 11 fishing types which occurred casualties frequently in numbers and occupied ratio were selected. Since the most frequent occurring casualties in fishing vessels were from collisions and fire explosion in statistics from KMST (2008~2014), the study focused on them. The collision is given a great deal of weight in all the casualties mostly due to the negligence of duty regardless of the job types. Gill netter, trap fishing boat, jig boat, multiple fishing boat and stow netter have their own specific causes of casualties in collision according to the operating types. The cause of fire explosion was mainly due to poor inspection and maintenance the electric cord. For this reason, it may be necessary for an operator to make strict precaution on the other vessels under way systematically, keep the regulation for preventing collisions, and for an engineer on watch to make a check the electricity periodically to reduce the fire explosion.

Investigation of the LPG Gas Explosion of a Welding And Cutting Torch at a Construction Site

  • Lee, Su-kyung;Lee, Jung-hoon;Song, Dong-woo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.811-818
    • /
    • 2018
  • A fire and explosion accident caused by a liquefied petroleum gas (LPG) welding and cutting torch gas leak occurred 10 m underground at the site of reinforcement work for bridge columns, killing four people and seriously injuring ten. We conducted a comprehensive investigation into the accident to identify the fundamental causes of the explosion by analyzing the structure of the construction site and the properties of propane, which was the main component of LPG welding and cutting work used at the site. The range between the lower and upper explosion limits of leaking LPG for welding and cutting work was examined using Le Chatelier's formula; the behavior of LPG concentration change, which included dispersion and concentration change, was analyzed using the fire dynamic simulator (FDS). We concluded that the primary cause of the accident was combustible LPG that leaked from a welding and cutting torch and formed a explosion range between the lower and upper limits. When the LPG contacted the flame of the welding and cutting torch, LPG explosion occurred. The LPG explosion power calculation was verified by the blast effect computation program developed by the Department of Defense Explosive Safety Board (DDESB). According to the fire simulation results, we concluded that the welding and cutting torch LPG leak caused the gas explosion. This study is useful for safety management to prevent accidents caused by LPG welding and cutting work at construction sites.

A Study on the Improvement of Safety Management of Hazardous Chemicals Handling in the Workplace (유해화학물질 취급작업장의 안전관리 개선에 관한 연구)

  • Jeong, Gyeong-Sam;Baik, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.12-19
    • /
    • 2014
  • Workplaces handling hazardous chemicals are scattered, because of old-aging facilities are have been operating for more than 20 years, there is still has the risk of an accident. Advanced countries including the UN and strengthen regulation of chemicals, but the frequent leak accidents have become a big issue socially. In the case of subsequent domestic accidental chemical accident, the government and related departments for the overall prevention, preparedness, response system has been checked and improved. In this study, improvements of the related system and the plan of safety management for on the prevention of accidents and the initial response were suggested throughout the analysis of problems on the actual condition of safety management and such as standard of the related systems for handling, management for occurring the main cause of the leak and chemical accidents from hazardous chemicals handling in the workplace.

Prediction of Poor Contact by Analysis of Electrical Signal and Thermal Characteristics (전기적 신호와 열적특성 분석에 의한 접촉불량 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.36-41
    • /
    • 2012
  • Electrical Connections often cause fires due to poor contact. Occurrence rate of these fires tends to increase annually. The reason why poor contacts occur is often because it is the low mechanical pressure at the contact points. A typical connection method using mechanical pressure is a screw terminal type. This study reviewed these poor contact cases in the screw terminals. In order to get reproduction of such cases, two types of experiments were conducted. the first one was conducted under the normal contact condition, and the other one was conducted under the poor contact condition that screw terminal of breaker was loosen and did not meet the requirements of toque value. In both types of experiments, compulsory vibration was adopted as a variable to aggravate poor contacts. Each of various current values(4.5A, 9.0A, 13.5A) is input. In these experiments, relationships of a contact, electrical signal such as current and electric pulse by ZCT and thermal characteristics according to vibration effect are analyzed. The suggested data and results in this study provide the useful resources helping to investigate fires due to poor contact, and they develop the detector for poor contact and finally reduce the electrical fire occurrence rate.

A Study on The Awareness of Fire-Fighting Officer for Strengthening Capabilities of Disaster Response System (재난현장 대응체계 역량강화를 위한 소방공무원 의식조사 연구)

  • Woo, Jaebong;Shin, Hojoon;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.276-281
    • /
    • 2013
  • This thesis grasped problems by examining the current status of disaster response system repeated during the disaster according to the changes of social environment and suggested current status of disaster response system and developmental measures through the investigation of the awareness of fire-fighting officer. On disaster site, close cooperation system of disaster safety measure headquarter and urgent rescue controlling association must be formed and range and time of the action must be accurately improved so as not to cause duplication of rights for orders. Also, systematic education and training system must be established so as to strengthen disaster site reaction capability and manpower and equipment for it must be increased. Finally, detailed measures for improving initial reaction capability during the disaster, such as tactic development, reaction plan establishment, etc, are requested.

Application Plan of Exhaust Systems in Strengthening Evacuation Safety in Apartment Houses (공동주택의 피난안전성 강화를 위한 배기시스템 활용 방안 연구)

  • Lee, Hyun-Sang;Yoon, Myung-Oh;Lee, Young-Ju;Kim, Jeong-Joon
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.49-57
    • /
    • 2020
  • Apartment buildings are becoming taller and more densely populated with the advancements in science and the development of cities, Consequently, various amenities and safety facilities are being developed to improve the quality of life for residents. However, according to statistics, the number of casualties in apartments accounts for a high proportion of accidents, and the leading cause of the casualties is smoke emitted from fires while sleeping at night. Although it is best to install separate indoor facilities in apartments to minimize smoke damages to occupants, it is useful to minimize the smoke damages by utilizing the installed facilities while reducing the financial burden of occupants. Based on the review, the heat exchanger ventilation system and the kitchen collective exhaust system were selected, and the feasibility of these systems was verified through fire simulation. From the verification results, the available safe egress time improved by 27, 30, and 35 s on the 25th, 35th, 50th floors, respectively.