• Title/Summary/Keyword: Cause of fire

Search Result 821, Processing Time 0.027 seconds

Cracking Behavior of Cement and Concrete Damaged by High Temperature of 800℃ (800℃ 조건에서의 시멘트 경화체의 균열 특성)

  • Ji, Woo-Ram;Park, Ji Woong;Shin, Ki Don;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.26-27
    • /
    • 2017
  • In this study, the cracking characteristics of cured pastes at 800℃ were investigated by X-ray CT. The test specimens were fabricated with and without aggregate, and the heating rate condition was applied at rapid heating (10.0℃/min). It is considered that the rapid heating condition does not cause a temperature gradient phenomenon because the temperature difference between the surface and the center of the sample is small due to a low heating rate unlike an actual fire. The cracking condition of the specimens without aggregate was more severe than that of specimens with aggregate.

  • PDF

A Study on Institutional Guarantee to Enhancing Diseases Management for Citizens and Fire Fighters exposed with Toxic Substances at a Disaster Site - based on lessons from 911 terrorism in the U.S. - (재난현장 유해물질 노출 시민 및 소방공무원 질병관리 제도적 보장에 관한 연구 -미국 911테러 사건을 통한 교훈을 기반으로-)

  • Kim, Jin-Keun;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.2
    • /
    • pp.1-13
    • /
    • 2017
  • In this study, using the synetics technique for strategies by making unfamiliarity into familiarity in the case of 911 terrorism. This study has meaningful messages for citizens and firefighters' illness caused by disaster sites in the field of disaster management in Korea. There are 7 stages to explain cause of a variety of cancers happening to citizens and firefighters in this study. The 7 stages are composed of real situation, direct analogies, personal analogies, symbolic analogies, new direct analogies, and review. This synetics will contribute to providing better ideas for citizens and firefighters' physical and mental health conditions.

A Study on Measuring Residues and Ignition Characteristics of the Gunpowder by Using a Handgun (권총용 화약잔사의 실측 및 발화특성에 관한 연구)

  • Song, Jae-Yong;Choi, Young-Woo;Kim, Dong-Hwan;Nam, Jung-Woo;Kim, Jin-Pyo
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.102-106
    • /
    • 2010
  • This paper studied the measurement about the gunpowder residue quantity by using a handgun and we carried out an experiment ignition characteristics of the gunpowder residue for the investigation fire cause into the indoor shooting range in Busan. The measurement of the gunpowder residue quantity is spouted by using a 0.38 inch gun and 9 mm gun. We were carried out evaluation experiments such as impact sensitivity test, static electricity sensitivity test, friction sensitivity test and measuring a flash point for the ignition characteristics about the gunpowder residue. From experiment results, the impact sensitivity and friction sensitivity of the gunpowder residue in comparison with ball powder are highly sensitive and the gunpowder residue ignites at a relatively low temperature.

Study of Occurrence Tendency and Cause Analysis of Arson (방화의 발생추이와 원인분석)

  • 김동현;김광일
    • Fire Science and Engineering
    • /
    • v.12 no.1
    • /
    • pp.27-33
    • /
    • 1998
  • Arson is one of the serious crime. It shows high increasing rate compared with the past, and the causes of arson are getting diversified and specialized in this modern society. In this thesis, the actual state and tendency of arson during latest 5 years have been analyzed on the basis of 'crime analysis' which is material of the National Police Agency. Based on the above analyzed material, measures for arson in foreign countries are examined and necessary matters to counter arson in Korea are inferred.

  • PDF

A Study on Fault Mode Control of a Soft Recoil System (연식주퇴 시스템의 오류모드 제어기법에 관한 연구)

  • Shin, Chul-Bong;Bae, Jae-Sung;Hwang, Jai-Hyuk;Kang, Kuk-Jeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.255-259
    • /
    • 2008
  • A soft-recoil system, which is a new technology, can dramatically reduce a recoil force. Due to the inaccurate explosion, various fault modes may happen. These fault modes can cause the serious damage of the recoil system and must be suppressed to avoid them. In the present study, the fault mode control method of the soft-recoil system is investigated. A hydraulic damper is working under normal mode and a MR damper is additionally working when the fault modes happen. In the design of the fault mode controller, the detection method of the fault mode is important as well as its suppression. The results of the simulation show that the soft-recoil system performs when the fault modes happen.

  • PDF

Improving the Safety Regulation For Self Contained Breathing Apparatus (특정소방대상물의 공기호흡기 안전규제 개선방안)

  • Lee, Sang-Pal
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.45-51
    • /
    • 2010
  • The objective of this study to analyse the cause and pattern of failing to use in Self Contained Breathing Apparatus using by government regulation for producer and client. Regulation for producer is related to legal and institution of safety inspectiontest of SCBA. Rregulation for client is preventive maintenance. Improving fail in use of SCBA are following. First, expansion of ad hoc collection inspection and safety checking is required. Second, the strict application of the law for monitoring and auditing disposal procedure in low performance SCBA is required.

A Study on the Unbalanced Current Distribution of HTS Power Cable (초전도 전력케이블의 전류 불평형에 관한 연구)

  • Kim, Jae-Ho;Park, Chung-Hwa
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.

A Study on the Cause Analysis and Countermeasures of the Traditional Market for Fires in the TRIZ Method (TRIZ 기법에 의한 재래시장 화재의 원인분석과 대책에 관한 연구)

  • Seo, Yong-Goo;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2017
  • The fires in the traditional markets often occur recently with the most of them expanded into great fires so that the damage is very serious. The status of traditional markets handling the distribution for ordinary people is greatly shrunk with the aggressive marketing of the local large companies and the foreign large distribution companies after the overall opening of the local distribution market. Most of the traditional markets have the history and tradition from decades to centuries and have grown steadily with the joys and sorrows of ordinary people and the development of the local economy. The fire developing to the large fire has the characteristics of the problem that the fire possibility is high since all products can be flammable due to the deterioration of facilities, the arbitrary modification of equipment, and the crowding of the goods for sale. Furthermore, most of the stores are petty with their small sizes so that the passage is narrow affecting the passage of pedestrians. Accordingly, the traditional markets are vulnerable to fire due to the initial unplanned structural problem so that the large scale fire damage occurs. The study is concerned with systematically classifying and analyzing the result by applying the TRIZ tool to the fire risk factors to extract the fundamental problem with the fire of the traditional market and make the active response. The study was done for preventing the fire on the basis of it and the expansion to the large fire in case of fire to prepare the specific measure to minimize the fire damage. On the basis of the fire expansion risk factor of the derived traditional market, the study presented the passive measures such as the improvement of the fire resisting capacity, the fire safety island, etc. and the active and institutional measures such as the obligation of the fire breaking news facilities, the application of the extra-high pressure pump system, the divided use of the electric line, etc.

The Development of Power Detection System Using One-Chip Microcontroller (원칩마이크로콘트롤러를 이용한 전력감시장치 개발)

  • Sin, Sa-Hyeon;Choe, Nak-Il;Lee, Seong-Gil;Im, Yang-Su;Jo, Geum-Bae;Baek, Hyeong-Rae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.180-186
    • /
    • 2002
  • This paper describes on the development of power detection system with one-chip microcontroller. The designed system is composed of power detection circuits and analyzing software. The system detects, 3-phases voltage, 3-phases current, external temperature, leakage current and stores in flash memory. AT89C52 was used as CPU and AM29F040B was used as memory to store the data. The analysis saftware was developed to detect the cause of the electrical fire incidents. With a data-compression technology, the data can be stored for the 43.5 days in a normal state, four hours and fifteen minutes in emergency state.

A Study on the Safety Improvement of Mixed Acid Storage Facility through the Accident Investigation Applicated by RCA (혼산 저장설비 사고의 근본원인 분석을 통한 안전성 향상방안)

  • Kwon, Nam-Ho;Kim, Dong-Joon
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.47-54
    • /
    • 2018
  • Mixed acid is very reactive and highly corrosive. it has been causing many accidents in a electronic industry, a steel industry, and a chemical industry. Therefore, it is required that the high safety level for the acid storage facilities. In this study, we investigated the accident causes for resent leak accidents with Root Cause Analysis (RCA). The root causes analysed by RCA were categorized as nine divisions by the their characteristics. Furthermore, each nine divisions causes was applied to the PDCA model which are using at OHSAS 18001. It is suggested that the nine division with the root causes can be the essential items for the development of the safety management manual. It is helpful to the safety improvement of the acid storage facility.