• Title/Summary/Keyword: Cause of fire

Search Result 819, Processing Time 0.027 seconds

Effects of Task Stress on the Job Satisfaction of Fire Protection Management Workers (소방시설관리업 종사자의 직무스트레스가 직무만족에 미치는 영향)

  • Lim, Kyoung-Yeon;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.130-139
    • /
    • 2019
  • This study identified the level of task stress experienced by fire protection system management workers and analyzed the effects of task stress on job satisfaction and proposed future response. First, task stress according to background cause showed differences in relation to age, position, monthly salary, total career, license, and task, but there was no difference in relation to academic background. Second, of the sub-parameters of stress, physical environment, task demand, organizational system, lack of reward, and workplace culture have negative effects on job satisfaction as stress increases, while interpersonal relation conflict and job insecurity do not have any effect. In the future, it will be necessary to investigate the empirical causes of work overload and to study organization-level stress relief measures.

Semi-numerical Study on the Flame Tilt Equation due to Wind on the Surface Fire in Forest Fire (산불 지표화에서의 바람에 의한 화염각 변화 산정식 도출에 관한 준-수치해석 연구)

  • Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.90-95
    • /
    • 2009
  • The wind is very important factor in forest fire spread. Flame spread has a change through wind pattern change in forest fire. In order to analyze the forest fire flame spread rate, change of flame tilt depending on wind may be considering first. This is be cause the flame spread rate varies by the flame tilt changed due to transfer of heat. Especially, as wind speed grow, flame gets closer to surface, heat transfer ratio increase, virgin fuel bed reaches ignition temperature more rapidly, and flame moves faster. This study deduces, through experiment and physical figure analysis, relations on the change behavior of flame tilt due to wind. The value of flame tilt angle calculated from the equation and the experiment value showed average error angle of $3.3^{\circ}$, which is relatively smaller than results of previous studies that used other coefficient. Froude number coefficient A can be calculated in the method provided in this research for estimation of flame tilt angle of virgin fuel bed with varying thermal properties. The research finding is expected to be applied to future studies on flame spread through numerical analysis of heat transfer.

A Literature Study on Ophthalmologic Disease Remedies of the four Famous Physicians in JinYuan Period (金元四大家의 眼病治療法에 關한 文獻的 硏究)

  • Kim, Seong-Bae;Kim, Jong-Han;Lim, Gyu-Sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.7 no.1
    • /
    • pp.15-34
    • /
    • 1994
  • This is a literature Study on ophthalmologic disease remedies of the four famous physicians in Jin Yuan period. The results were as follows: 1. Yu Wan So regarded the cause of ophthalmologic disease as the wind and heat(風熱), the blood deficiency(血少), or the deficiency of vital function and essence ,of the kidney(腎氣虛). For each treatment he used the method to remove wind and heat(除風散熱), the tranquillizing and tonifying method to nourish the heart and to relieve mental strain due to dificiency of vital essence(養血安神). the method to nourish Yin in the kidney(補腎水). The important nature of the these medicines is bitter and cold. 2. Jang Jong Jeung regarded the cause of ophthalmologic disease as the blood excess(血太過). or the blood deficiency(血不及). or the fire and heat(火熱). For each treatment he used the method to extract blood(出血療法). the method to nourish the liver and the kidney(補肝腎療法). or the method of vomiting and diarrhea(吐不法). The medicines are usuallly classified into external treatment medicines(外用藥). medicines to disintegrate mass(破積聚藥). purgating medicines(攻下藥). 3. Lee Dong Won regarded the cause of ophthalmologic disease as the spleen and the stomach weakness(脾胃虛弱), excessive fire in the heart(心火太盛). For each treatment he used the method to tranquillize the spleen and the stomach (調理脾胃). the tranquillizing and tonifying method to nourish the heart and to relieve mental strain due to deficiency of vital essence(養血安神). 4. Ju Dan Gye regarded the cause of ophthalmologic disease as the wind and heat(風熱). the blood deficiency(血少). the mental exhaustion(神勞). the kidney weakness(腎弱). For each treatment he used the method to remove wind and heat(除風散熱), the method to nourish blood and yin water(養血補水), the method to relieve mental strain and to remove spiritual heat(安腎瀉神火). the method to nourish yin water(養陰水). These drugs are usually classified into the medicines to remove endogenous heat(淸熱藥). the medicines to nourish yin(補陰藥).

  • PDF

A Study on Fire Analysis According to Temperature Characteristics of an Incandescent Electric Lamp at 220V/100W (220V/100W 백열전구의 온도특성에 따른 화재분석에 관한 연구)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Young-Seok;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, we are studied on the temperature characteristics and fire progress of an incandescent electric lamp at 220V/100W. In the case of stationary state, the ignition possibility of the incandescent electric lamp due to the heat generation was low because the temperature was measured at $161.9^{\circ}C$ the temperature was increased at $538.1^{\circ}C$ in the airtight chamber, but it does not generated the fire because the oxygen was not exist in the airtight chamber. When the lamp is broken, the filament of lamp was melted in the air. The gas of lamp interior spurted to the weakest part by external flame. Thus, the incandescent electric lamp is high possibility of fire when oxygens from airtight space. Also, it is known that the possibility of ignition is very high if combustion materials(sawdust) exists on surrounding. These experimental results will be utilized for the data in the investigation electrical fire cause.

Analysis on the Fire Accidents Vehicles Caused by Faults in the Same Anti-lock Brake System (ABS) of the same Manufacturer (동일한 제조사의 ABS 모듈 결함으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Lee, Dong-Kyu;Cho, Young-Jin;Moon, Byung-Sun;Song, Jae-Yong
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.121-127
    • /
    • 2019
  • This study examined a fire accident caused by a defect in the vehicle ABS module. A large number of vehicles using the same manufacturer's ABS module in recent fire events showed a tendency to combust due to the same faults. As previously stated in the ABS module which shows the electrical breakdown between the power lines supplied to the constant power source by the battery. The electrical breakdown of the ABS module was caused by defects of the ABS module itself that were influenced by of the external flame. These results highlight the need to determine if there is a deficiency of the ABS module in the investigation of the cause of a fire in a vehicle which is produced by the same manufacturer.

A Study on Dynamic Characteristics of EFPCD for Electrical Fire Prevention (전기화재 예방을 위한 EFPCD동작 특성에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.8-11
    • /
    • 2002
  • Recently, the spark and the overheat due to in the failure of pressure contacts on connecting points and the momentary short circuit have been the major causes of electrical fire because these may cause the deposition and the graphite of insulating materials in electrical wiring system. Also, because in these cases the current is a surge one, the losses and faults of a communication, a home appliances, a computer and a measuring instrument may occur. Especially, in such cases, we are very difficult to detect the failure of pressure contacts on connecting points and the momentary short circuit. In this paper, we have developed an auxiliary control device, the electrical fire prevention control device(EFPCD), of an earth leakage breaker(ELB). And we can pre-vent the electrical fire caused by the spark and the overheat occurring in the failure of pressure contacts in connecting points and the momentary short circuit with the EFPCD.

Night fire fighting helicopters operations and Aviation Safety (야간산불진화 헬기 운영과 항공안전)

  • Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.1
    • /
    • pp.145-151
    • /
    • 2014
  • Not only in Korea, but also in other countries, most helicopter accidents occur at low altitude. Analysis on accidents data collected both in Korea and other countries has brought two conclusions. Firstly, helicopter operations during the night hours carries a high risk. Secondly, the most common cause of night hour operations is loss of control due to the flight illusion. As an operation relying on a night vision in particular has a very high accident hazard, accompanying instruments such as NVG are ought to be provided. Hence, a thorough preparation and inspection on missions for night forest fire extinguishing should be required and perfect guidelines/road maps and enough training programs for the operation should be provided before the engagement in missions.

Distribution of Heat and Smoke Related to Openings in Hise-Rise Apartment Building Fires (고층 공동주택의 개구특성에 따른 화재시 열.연기유동에 관한 연구)

  • 이지희
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.59-79
    • /
    • 2001
  • The paper proposes alternatives for fire safety in architectural planning through heat-smoke distribution related to openings so that we decrease casualty and property loss by fire and lay a great emphasis on building high-rise apartments with consideration of fire safety in Korea. An analysis program(HFA-Heat Fluid Analysis) is built to perform simultaneously numerical analysis and experimental analysis on rooms, units and buildings. In consequence, on the first, fire prevention methods are required to be set up related to openings for design rooms since the flow of heat and smoke is influenced by the type of openings in high-rise apartments. Second, the numerical analysis showed that different planning types cause to show differences in the spreading time of heat and smoke to design the units of high-rise apartments. On the third, each unit building showed different fire behavior depending on openings by numerical analysis and small scaled experiment on heat and smoke flow.

  • PDF

Analysis of perception and parent education demand through parent experience of fire (화재에 대한 부모경험을 통한 인식도와 부모교육 요구도 분석)

  • Kim, In-Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.85-93
    • /
    • 2013
  • This study is based on parents that have preschool children of age 4~5, and analyzes the perception and parent education demand through parent experience of fire. As a result of the study about perception through parent experience about safety life, safety accidents, safety education of fire, the effect of parents' safety consciousness to fire safety life turned out to be moderate for fathers and large for mothers. The safety education method was mostly done in speaking than experience for fathers, while mothers did education through experience in daily life. Also the difficulties in safety education was lack of educating time for fathers while it was lack of knowledge and methods for mothers. Perception through parent experience of fire safety accidents showed that fathers did not have experience of fire safety accidents while mothers did. The locations perceived by parents where fires mostly occurred showed to be within home for both parents, and both administered first aid in managing fires. Perception through parent experience of fire safety education showed the importance of fire safety education to be important in both parents, and both parents had no experience in fire safety education. Also the fire safety education knowledge acquisition method was TV or the Internet for fathers, while it was participating in seminars or lectures for mothers. Fathers were moderately satisfied of the fire safety education instruction of childhood education centers, while mothers were slightly dissatisfied. For the demand of parent education about fire safety education, fathers were moderate while mothers thought it necessary of parent education necessity. The reason why parent education was needed was to be able to know immediate and prompt measures and first aid treatment in emergency situations for fathers, while it was to figure out the cause of fire safety accidents and prevent it beforehand for mothers. For the education institution of fire safety education, fathers demanded it for safety related institutions while mothers demanded it for children education institutions, and the number of times for parent education was once or twice a year for fathers while it was once a month for mothers. For the parent education instructor of fire safety education, fathers demanded safety education experts while mothers demanded infant teachers that completed the safety education course. For the fire safety education method of parent education, fathers demanded Internet searching while mothers demanded seminars or lectures.

Experimental Performance Evaluation of a Fire System for Apartment Buildings (공동주택 전용화재시스템의 성능평가를 위한 실험적 연구)

  • Jung, Jong-Jin;Hong, A-Reum;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.51-56
    • /
    • 2015
  • In Korea, measures to maintain sustainable fire safety performance for apartment buildings are insufficient in terms of fire-fighting products, skilled personnel, and maintenance status. Also, because of the particular features of a fire compartment, it has structural problems that are very likely to cause damage to human life when a fire occurs. Currently, problems with the fire supervisory system installed in an apartment building cannot be checked in real time, so it is difficult to identify the location of a fire accurately. Protected areas are also not assigned to each household, and residents cannot be clearly informed of the occurrence of a fire. As a consequence, safety evacuation cannot be secured. In addition, it is impossible to test the operation performance for water detectors in sprinkler fire extinguishing systems outside of the household. Therefore, an experiment was conducted to evaluate the performance of a remote fire supervisory system. The results show that the system satisfies all performance requirements. Also, an household alarm system was installed in each household to alert of any occurrence of a fire accurately, and the performance of the alarm system was improved to ensure that residents were quickly evacuated.