• Title/Summary/Keyword: Cause of fire

Search Result 819, Processing Time 0.056 seconds

A Study on the Effective Smoke Control Method of Large Volume Space Comparted by Smoke Reservoir Screen (제연경계벽으로 구획된 대형공간의 효과적인 제연방안에 관한 연구)

  • Kim, Tae-Hoon;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.34-41
    • /
    • 2011
  • This research examines problem that can happen in partial smoke control method among contiguity area smoke control system through engineering examination and CFD. And the ultimate purpose of this is to secure safety of a person inhabiting at fire department by presenting improvement plan. Now a days, in large space-area such as department store or mega-mall in which mainly applies "Partial Smoke Control Method", air is suppled from adjacent area and smoke is exhausted in fire room. For various reason, however, it is confirmed through simulation that if air is suppled in one direction, this can cause a fatal result to people of fire area because of the difficulty in securing the evacuation time. As an improvement plan, air is supplied at the same time in surroundings to fire department.

A Research for Assessment Fire Toxic Gas of Construction Material Using FT-IR and FED (FT-IR과 FED를 이용한 건축 재료의 연소독성평가에 관한 연구)

  • Kim, Sung-Soo;Cho, Nam-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.27-31
    • /
    • 2011
  • In this study, combustion toxicity evaluation for building interior materials and study for toxicity as using FT-IR analysis. this experiment for the calculation of toxicity index, it using a cone calorimeter model in KS F ISO/TR 9122-4 as a fire model. It is following ISO 19702 procedure for assessing fire toxic gas using FT-IR. This experiment used calculation method for toxicity index (FED) among the international standards. $LC_{50}$ is a concentration that it can cause death to 50 % of experimental animal in 30 minutes - exposure gas test. comparison with the three kinds of toxicity fire gas of construction materials using toxicity index.

A Study on method to construct system for u-Safe fire management support (u-Safe 소방대응지원 시스템 구축방안에 관한 연구)

  • Jeon, Jai-Pil;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1201-1209
    • /
    • 2008
  • In Seoul, there are lots of skyscrapers that have above 60 stories and buildings that have more than 8 basement levels, as well as massive distribution complex region which is connected to subways, departments, malls, hotels, and exhibition halls. When an accident, such as fire and explosion, happens in these areas or structures, if we can't find where fire-fighters are, who go into the building to suppress the fire, we couldn't be sure of their safety as well as effective command. Actually, it may cause much more damage itself and restrict either fire suppression or lifesaving. To protect people's life and properties as much as possible, this study will show the method to construct system of disaster-management supports with effective operation of fire force and scientific fire strategy in the scene by using Ubiquitous technique to enormous disasters.

A Study on the condition of Indoor environmental safety in kindergarten (유아교육기관의 실내 환경 안전 실태에 관한 연구)

  • Choi, Eun-Jin;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.242-246
    • /
    • 2008
  • This study is to research on the condition of safe environment of kindergartens. This study is to supplement the preceding study which was based only on survey to show the result and analyze the condition and problems of the safety of kindergartens to suggest the basic database of indoor environment that cause accident. First as a theoretical study, we analyze the preceding studies according to the related regulations. And we made checklist based on this and visited and investigated two kindergartens where applied for the case study As the result, we could understand factors that can cause accidents from classroom, corridor, door, stairs, balustrade, toilet, kitchen, front door, and fire exit/shelter. Especially, in case of fire exit/shelter, the whole renewal of kindergarten was necessary which is difficult. But, though it can not be advanced right away, they should try to have facility expansion and repair works gradually. And for more study on this, active cooperation from kindergartens are in need.

  • PDF

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.

Exploratory study on the based on big data for fire prevention of multiple shops (다중이용업소의 화재예방을 위한 빅데이터 기반의 탐색적 연구)

  • Jeon, Byungkwan;Lee, Sung-Won
    • Journal of Industrial Convergence
    • /
    • v.16 no.4
    • /
    • pp.27-32
    • /
    • 2018
  • In this research, in order to prevent the fire of multiple users who are concerned about many human life damage, based on the statistical data of the National Fire Protection Agency's National Fire Information Center and the Fire Defense Administration Fire Defense Administration, Attempts were made on the exploratory approach to measures that can reduce the topic of. In this research, using the preventive firefighting administrative statistics of the Fire and Disaster Management Agency, we analyzed by focusing on the effectiveness of multiple users' firefighting safety education. Through analysis results we could infer that fire safety education does not have effectiveness in actual fire prevention. Through previous research, we found out that the cause is insufficient for the management of fire safety education, thereby deriving an improvement plan to develop a systematic fire safety education system.

Study on Fire Risk of Air Conditioner through Fire Cases (화재사례를 통한 에어컨의 화재위험성 연구)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.70-77
    • /
    • 2017
  • As the quality of live gets better, the frequency of using air conditioner is along drastically increasing. On that matter, setting up measures of preventing increasing fire cases has been required. 43,413 fire cases occurred in last 2016, the cases occurred by electricity account for about 20%(8,655 cases). Among the electricity cases, the amount of cases occurred with air conditioner issues covers 1.5%; causes of the fire incidents vary, including incomplete contacts, short circuits, tracking, and such. In this study, we intend to investigate the case of ignition at the connection point where the power cord connected to the outdoor unit is arbitrarily connected during the air conditioner installation process, and to propose preventive measures against the cause in order to reduce the damage of life as well as the property from electric fire incidents.

Design of the Integrated Fire Automation System(IFAS) on based P-Type Fire Control Panel (P형 수신기 기반 통합화재 자동 시스템의 설계)

  • Kim, Hyun-Ju;Park, Jae-Heung;Seo, Yeong-Geon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.12
    • /
    • pp.133-142
    • /
    • 2010
  • P-type fire control panel, currently in use, has a big hazard that can cause the large scaled human death tolls and property damage in the massive fire because it is difficult to identify in real time the location of fire outbreak and whether search-device are broken down or not. In this paper, I suggest that the integrated fire automation system on based p-type fire control panel should be used, which can detect in real time the signal that occur when whether search-device are broken down or not, and can detect the arisen circumstances information of p-type fire control panel on the fire signal in the far away. The devised systems have designed and embodied the analysis of circumstances information and module that can analyze the circumstances information from the p-type fire control panel and the part of internet access installment which can gather and deliver the circumstances information from the fire prevention facility receiver.

Cable Functional Failure Time Evaluation for a Main Control Room Fire using Fire Dynamic Simulator (FDS 이용한 주제어실 화재시 케이블 기능상실시간 평가)

  • Lim, Heok-Soon;Kim, In-Hwan;Kim, Myung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • Serious electrical problems, such as shorts, ground faults, or circuits, often cause fire events in the fire proof zone of nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety-related systems and equipment. The fire event can be treated with the basic design principle that safety systems should maintain their functions with redundancy and independency. In the case of a cable fire in the main control room, operators cannot perform their mission properly and can misjudge the situation because of spurious operation, incorrect indication or instrument. These would deteriorate the plant capabilities of safety shutdown and result in disastrous conditions. Therefore, during a main control room fire, 5 minutes of operator action time is very important to operate the safety shutdown components. This paper describes the cable functional failure temperature criteria and conducted a cable functional failure time evaluation using Fire Dynamic Simulator to obtain the operator action time for a main control room fire.

Post-buckling behaviours of axially restrained steel columns in fire

  • Li, Guo-Qiang;Wang, Peijun;Hou, Hetao
    • Steel and Composite Structures
    • /
    • v.9 no.2
    • /
    • pp.89-101
    • /
    • 2009
  • This paper presents a simplified model to study post-buckling behaviours of the axially restrained steel column at elevated temperatures in fire. The contribution of axial deformation to the curvature of column section is included in theoretical equations. The possible unloading at the convex side of the column when buckling occurs is considered in the stress-strain relationship of steel at elevated temperatures. Parameters that affect structural behaviours of the axial restrained column in fire are studied. The axial restraint cause an increase in the axial force before the column buckles; the buckling temperature of restrained columns will be lower than non-restrained steel columns. However, the axial force of a restrained column decreases after the column buckles with the elevation of temperatures, so make use of the post-buckling behaviour can increase the critical temperature of restrained columns. Columns with temperature gradient across the section will produce lower axial force at elevated temperatures.