• Title/Summary/Keyword: Cause Conditions

Search Result 2,531, Processing Time 0.038 seconds

Application of Directional Over Current Protection Schemes Considering the Fault Characteristics in the Distribution System with Dispersed Generation (분산전원이 연계된 배전계통의 고장특성을 고려한 방향성 보호계전 방식 적용 연구)

  • Jung, Won-Wook;Lee, Hak-Ju;Kwon, Seong-Chul;Chae, Woo-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.97-107
    • /
    • 2010
  • Penetration of distributed generator(DG) to power distribution system can cause malfunction of existing protection schemes. Because grid interconnected DG can contribute fault currents and make bidirectional current flows on the system, fault contributions from DG can cause an interference of protection relay operation. Therefore, over current protection device of the distribution system with DGs need directional protection schemes. In this paper, improved directional protection algorithms are proposed for the distribution system with DG considering their fault characteristics. And than, these directional protection algorithms are tested and validated in various fault conditions. From the simulation results, it can be seen that the proposed directional protection algorithms are practically efficient for the radial distribution system with DG.

Load history measurement of end beam of welded structure bogie for railway freight car (화차용 용접구조대차 엔드빔의 하중이력 측정)

  • Ham Young-Sam;Seo Jung-Won;Lee Dong-Hyong;Jeon Eung-Sik
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.103-108
    • /
    • 2003
  • Among welded structure bogies in use for high speed freight car, a part of bogies manufactured in 1999 and 2000 have found problems that failure occurs in its end beam. In case of a freight car a difference of weight between empty and loading conditions are worse than in case of a passenger car. Moreover its brake system is tread brake without second suspension system. A failure of end beam is supposed to be due to loading by brake rather than vertical loading by freight. This failure can make brake system useless and may be a cause of derailment in the worst case. In this study, in order to be proved the cause of failure and to solve the problem it is described that we have measured load history acted on end beam and set up the procedures.

  • PDF

A Study on the Quality Properties of Low Heat Concrete according to Kinds of Cement (시멘트 종류에 따른 저발열 콘크리트의 품질특성에 관한 연구)

  • Kim, Sung;Choi, Sung-Woo;Jo, Hyun-Tae;Jun, Joun-Young;Ryu, Deuk-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.777-780
    • /
    • 2006
  • Recently, owing to the development of industry and the improvement of building techniques, the concrete structure is becoming larger and higher. In hardening these large concrete, the heat of hydration gives rise to considerable thermal stress depending on the size and environmental condition of concrete, which might cause thermal cracking. Especially, the crack may cause severe damage to the safety and the durability of concrete structure. This study is investigated the thermal properties of concrete according to several binder conditions, such as OPC, Belite Rich Cement(BRC), Low-Heat-Mixed Cement(LHC), Fly ash added cement. As a result of this study, the Flowability of concrete was beetter with BRC and LHC than FA(25) and OPC. On the other hand, LHC gets superior effect in the control of heat hydration, it's caused by the volume of OPC.

  • PDF

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • Oh, Kyu-Hwan;Jiang, Bo;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

A study on the ergonomic aspects of the proper luminance level of displays

  • Lee, Eunjung;Kim, Sangho;Park, HyeRyoung;Bae, Jaewoo;Lee, Seungbae;Kim, Haksun
    • Journal of Information Display
    • /
    • v.13 no.4
    • /
    • pp.159-166
    • /
    • 2012
  • In this paper, a display's emotional image quality can be primarily determined by designing the proper luminance level. Though displays with high luminance are preferred, too much light emission from a display may cause glare or visual fatigue to viewers. To find out the proper luminance level based on various video contents, this study was conducted with an OLED display with a real-black level and a wide color gamut, and with an LCD display with a high luminance level, to set the glare threshold under various conditions. The optimum luminance levels according to the display's loading ratio were found, and the maximum luminance that did not cause a glare in the test is proposed.

Development of a Fuzzy Logic-based Fault Identification System In Distribution System (퍼지 논리 적용에 의한 배전계통의 고장 검출 시스템 개발)

  • Kim, Chang-Jong;Oh, Yong-Taek
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.737-739
    • /
    • 1996
  • Abnormal conditions and disturbances in distribution system cause an immediate influence to the customers. Conventional detection schemes for the distribution abnormalities have been applied in limited extents mainly because of their low reliability. In this paper, we developed a disturbance identification system which monitors the load level after a transient, checks the harmonic behavior of the load, and finally makes decision on the cause of the disturbance. This system identifies and discriminates overcurrent faults, arcing ground faults, recloser activities, and foreign object or tree contacts. In the implementation of the identification system, we applied fuzzy logic to better represent some variables whose Quantities are expressed only in non-numerical terms.

  • PDF

A structural analysis of deep depth injection mold to investigate the cause of crack (깊이가 깊은 사출금형의 크랙 원인 파악을 위한 강도해석)

  • Choi, S.H.;Lyu, M.Y.;Kim, D.W.;Kim, S.Y.;Shin, K.S.;Kim, K.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.297-300
    • /
    • 2008
  • High pressure is involved during injection molding operation specially packing phase. Cracks in the mold are often occurred by high cavity pressure. In this study, structural analysis of mold has been performed using commercial softwares, Abaqus and Ansys, to investigate cause of crack in the injection mold. Structural analysis contains four cases: stress distribution according to the cavity pressure, stress concentration according to the boundary conditions, stress concentration for inter-locking design of mold, and stress concentration for distributed cavity pressure. Through this study it was observed that the locations of stress concentrations were coincident with locations of crack. Robust mold design is being required to withstand high cavity pressure.

  • PDF

Dynamic Response Localization of Simple Periodic Structures Undertaking External Harmonic Forces (조화 외력을 받는 간단한 주기적 구조물의 동적 응답 국부화)

  • 김재영;유홍희
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.6
    • /
    • pp.175-180
    • /
    • 2001
  • Dynamic response localization of simple mistuned periodic structures is presented in this paper Mistuning in periodic structures can cause forced responses that are much larger than those of perfectly tuned structures. So mistuning results in the critical impact on high cycle fatigue of structures. Thus, it is of great importance to predict the mistuned forced response in an efficient way. In this paper, forced responses of coupled pendulum systems are investigated to identify the localization effect of periodic structures. The effects of mistuning and damping on the maximum forced response are examined. It is found that certain conditions of mistuning and coupling can cause strong localization and the localization becomes significant under weak damping. It is also found that the maximum forced response increases as the number of Periodic structures increases.

  • PDF

Pitfalls in the Diagnosis of Vertigo (현훈 진단에 있어 함정)

  • Kim, Hyun Ah;Lee, Hyung
    • Journal of the Korean neurological association
    • /
    • v.36 no.4
    • /
    • pp.280-288
    • /
    • 2018
  • Vertigo/dizziness is a common complaint in patients who are seeking a primary health clinic. Vertigo is traditionally attributed to damage of the vestibular system. Many peripheral and central vestibular disorders are usually presented with vertigo. However, patients with benign paroxysmal positional vertigo (BPPV), a leading cause of vertigo, may present with postural lightheadedness, near faint, imbalance rather than true vertigo. On the contrary, patients with orthostatic hypotension may present with true spinning vertigo, not dizziness. Persistent postural perceptual dizziness, a second most common cause of dizziness (after BPPV), is mainly occurred after organic vestibular disorders such as BPPV or vestibular neuritis, and classified as a chronic functional vestibular disorder. This article describes non-vestibular disorders presenting dizziness and/or vertigos, which conditions may be misdiagnosed as structural vestibular disorders.

Does Achilles Tendon Shortening Mean Pathologic Lesions? (짧은 아킬레스건의 의미)

  • Won, Sung Hun;Chun, Dong-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.25 no.2
    • /
    • pp.55-60
    • /
    • 2021
  • This review article attempts to describe several pathological conditions that can arise from the shortening of the Achilles tendon. The tension and tightening of the gastrocnemius-soleus-Achilles tendon complex (GSAC) can cause disharmony in the movement of the entire foot as well as the ankle joint when subjected to weight-bearing or walking. In addition, since these phenomena are observed in various lesions of the ankle joint, the dynamic shortening caused by the tension of GSAC may not be the primary cause of various ankle joint lesions, but is still considered to be a significant contributing factor.