• Title/Summary/Keyword: Cathodic

Search Result 754, Processing Time 0.029 seconds

Effect of V and Sb on the Corrosion Behavior and Precipitate Characteristics of Zr-based Alloys for Nuclear Fuel Cladding (핵연료 피복관용 Zr합금의 부식거동 및 석출물 특성에 미치는 V, Sb 첨가의 영향)

  • Jeon, Chi-Jung;Kim, Seon-Jin;Jeong, Yong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.8 no.12
    • /
    • pp.1099-1109
    • /
    • 1998
  • To investigate the effect of V and Sb on the corrosion behavior of Zr- based alloys, corrosion tests were performed on 6 kinds of Zr alloys in an autoclave at $360^{\circ}C$ for 100 days. The transition of the corrosion rate occurred in the sample containing 0.1wt.%V after 10 days but did not occur in the samples containing 0.2wt.%V and 0.4wt.%V. The corrosion resistance of V containing alloys increased with increasing V contents from 0.1 to 0.4wt.% and the alloys containing 0.4wt.%V showed the best corrosion resistance. In the ternary alloys containing 0.1wt.%Sb and 0.4wt.%Sb, the corrosion rate increased significantly from the short exposure time. It was observed that the optimal Sb content for corrosion resistance was 0.2wt.%. The size and volume fraction of precipitates increased with increasing V and Sb contents. The superior corrosion resistance was observed in the Zr alloy having precipitate size of 0.11-0.13$\mu\textrm{m}$. From the result of corrosion behavior and the obserbation of precipitates, the optimal size of the precipitate appear to control the electron conduction in the cathodic reaction and play an important role in maintaining a stable oxide microstructure.

  • PDF

A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD (정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구)

  • Shin, Dong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF

ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA (인공타액에서 아말감의 부식거동에 관한 전기화학적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

Differential Pulse Voltammetric Determination of Co(II) Ion with a Chemically Modified Carbon Paste Electrode Containing ${\iota}$ -Sparteine (${\iota}$ -Sparteine으로 변성된 Carbon Paste 전극을 사용한 Co(II) 이온의 펄스 차이 전압-전류법 정량)

  • Eu-Duck Jeong;Mi-Sook Won;Deog-Su Park;Yoon-Bo Shim;Sung-Nak Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.881-887
    • /
    • 1993
  • A cobalt(II) ion-selective carbon-paste electrode (CPE) was constructed with ${\iota}$-sparteine. Cobalt(II) ion in aqueous solution was chemically deposited through the complexation with ${\iota}$-sparteine onto the CPE. The surface of CPEs were characterized by cyclic voltammetry and differential pulse voltammetry in an acetate buffer solution, separately. Exposure of the CPEs to an acid solution could regenerate surface to reuse it for the deposition. In more than 5 deposition / measurement / regeneration cycles, the response was reproducible and linear up to $5.0{\times}10^{-6}$M with linear sweep voltammetry. The peaks at 0.17V / 0.27V were correspond to the redox of Co(II)-SP complex deposited on CPE. The anodic peak of which appeared after scan over the cathodic peak of 0.17 V to more negative scan. In case of using the differencial pulse voltammetry (DPV), we have obtained the linear response $2.0{\times}10^{-7}$M with relative standard deviation ${\pm}5.6%$. The detection limit was $1.0{times}10^{-7}$M for 20 minutes of the deposition. We have also investigated the interference effect of various metal ions, which are expected to form the complex with the ligand on the electrode.

  • PDF

Stability of Tris(2-cyclohexylaminoethyl)amine-Zn(II) Complex (Tris(2-cyclohexylaminoethyl)amine-Zn(II) 착물의 안정성)

  • Yong Woon Shin;Hyun Sook Baek;Jae-Kyung Yang;Jineun Kim;Moo Lyong Seo
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • Tris(2-cyclohexylaminoethyl)amine (L) was synthesized by the Schiff base condensation reaction of tris(2-aminoethyl)amine with cyclohexanone, followed by reduction. The thermodynamic characteristics, mole ratio and formation constant of [Zn(II)-L] complex were measured by the cyclic voltammetry and isothermal titration. In the case of Zn(II), well-defined cathodic and anodic peak were obtained at -1.02V and -0.48V vs Ag/AgCl , respectively. For the [Zn(II)-L] complex, both peaks were obtained at -1.19V and -0.45V vs Ag/AgCl, respectively. In addition, the peak height gradually increases as the scan rate increases, suggesting that the currents obtained were diffusion - controlled. The mole ratio and stability constant of the complex measured cyclic voltammerty were 1:1 and logK$_f$= 5.8, respectively. And the mole ratio and stability constant of the complexe calculated by isothermal titration method was 1:1 and logK =5.4, respectively. ${\Delta}$H, ${\Delta}$G and T${\Delta}$S for the complex formation were -53.0 kJ/mol, -31.1 kJ/mol, and -21.9 J/K at 25 ${\circ}$C, respectively.

Preparation of LiFe PO4 Using Chitosan and its Cathodic Properties for Rechargeable Li-ion Batteries

  • Hong, Kyong-Soo;Yu, Seong-Mi;Ha, Myoung-Gyu;Ahn, Chang-Won;Hong, Tae-Eun;Jin, Jong-Sung;Kim, Hyun-Gyu;Jeong, Euh-Duck;Kim, Yang-Soo;Kim, Hae-Jin;Doh, Chil-Hoon;Yang, Ho-Soon;Jung, Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.8
    • /
    • pp.1719-1723
    • /
    • 2009
  • The LiFeP$O_4$ powder was synthesized by using the solid state reaction method with Fe($C_2O_4){\cdot}2H_2O,\;(NH_4)_2HPO_4,\;Li_2CO_3$, and chitosan as a carbon precursor material for a cathode of a lithium-ion battery. The chitosan added LiFePO4 powder was calcined at 350 ${^{\circ}C}$ for 5 hours and then 800 ${^{\circ}C}$ for 12 hours for the calcination. Then we calcined again at 800 ${^{\circ}C}$ for 12 hours. We characterized the synthesized compounds via the crystallinity, the valence states of iron ions, and their shapes using TGA, XRD, SEM, TEM, and XPS. We found that the synthesized powders were carbon-coated using TEM images and the iron ion is substituted from 3+ to 2+ through XPS measurements. We observed voltage characteristics and initial charge-discharge characteristics according to the C rate in LiFeP$O_4$ batteries. The obtained initial specific capacity of the chitosan added LiFeP$O_4$ powder is 110 mAh/g, which is much larger than that of LiFeP$O_4$ only powder.

Electrochemical Characteristics of Ruthenium Oxide Electrode-Organic Electrolyte System (유기전해액에서 루테늄산화물 전극의 전기화학적 특성)

  • Doh, Chil-Hoon;Jin, Bong-Soo;Moon, Seong-In;Yun, Mun-Soo;Choi, Sang-Jin;Yug, Gyeong-Chang;Park, Jeong-Sik;Kim, Sang-Gil;Lee, Joo-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.169-173
    • /
    • 2003
  • Electrochemical capacitor made with metal oxide electrode uses rapid and reversible protonation/deprotonation of metal oxide material under the aqueous acidic solution, generally. Electrochemical stability window of aqueous electrolyte-type capacitor is narrow compared to that of organic electrolyte-type capacitor. Electrochemical characteristics of electrochemical capacitor made with metal oxide electrode and lithium or ammonium cation based organic electrolyte were evaluated. Electrochemical capacitor based on $RuO_2$ electrode material and 1M $LiPF_6$ in mixed solvents of EC, DEC, and EMC has anodic and cathodic specific capacitance of 145 and $142F/g-RuO_2{\cdot}nH_2O$, respectively, by using cyclic voltammetry with scan rate of 2mV/sec $g-RuO_2$ in potential range of $2.0\~4.2V(Li|Li^+))$.

Electrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

  • Giribabu, Krishnan;Jang, Sung-Chan;Haldorai, Yuvaraj;Rethinasabapathy, Muruganantham;Oh, Seo Yeong;Rengaraj, Arunkumar;Han, Young-Kyu;Cho, Wan-Seob;Roh, Changhyun;Huh, Yun Suk
    • Carbon letters
    • /
    • v.23
    • /
    • pp.38-47
    • /
    • 2017
  • In this study, magnetite ($Fe_3O_4$) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like $Fe_3O_4$ nanoparticles with a mean size of < 80 nm were electrodeposited on a glassy carbon electrode (GCE). The $Fe_3O_4/GCE$ was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the $Fe_3O_4/GCE$ was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the $Fe_3O_4/GCE$. The electrocatalytic ability of $Fe_3O_4$ was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the $Fe_3O_4/GCE$ exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of $0.09-47{\mu}M$ with a correlation coefficient of 0.9919 and a limit of detection of $0.09{\mu}M$ (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.

Time-Dependent Modeling of Performance Degradation for PEMFC Single Cell System to Evaluate the Cell Performance and Durability: Effects of CO Poisoning (고분자전해질 연료전지의 성능과 안정성 시험을 위한 단위전지의 시간 경과에 따른 모델링: 일산화탄소 피독현상에 의한 효과)

  • Kim, Jong-Sik;Kim, Pil;Joo, Ji-Bong;Kim, Woo-Young;Yi, Jong-Heop
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • There have been great attentions on polymer electrolyte membrane fuel cell (PEMFC) due to their advantageous characteristics such as zero emission of hazardous pollutant and high energy density. In this work, we evaluated degradation phenomena and stability of single cell performance via one dimensional single cell modeling. Here, CO poisoning on anode on anode was considered for cell performance degradation. Modeling results showed that the performance and stability were highly degraded with CO concentration in fuel gas. In addition, cell performance was reduced by slow oxygen reduction on cathode in long term operation. In order to overcome, it is required to increase ratio o#hydrogen in the fuel gas of anode and high Pt loading contained in the cathodic catalyst layer.

  • PDF

The Effect of Passing Aged Years to the Polarization Characteristics of Embedded Steel Bar of Mortar Specimen(W/C:0.4) (몰타르 시험편(W/C:0.4) 내부철근의 분극특성에 미치는 재령년수의 영향)

  • Moon, Kyung-Man;Won, Jong-Pil;Park, Dong-Hyun;Lee, Sung-Yul;Jeong, Jin-A;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • The structures of reinforced concrete has been extensively increased with rapid development of industrial society. Futhermore, these reinforced concretes are easy to expose to severe corrosive environments such as sea water, contaminated water, acid rain and seashore etc.. Thus, corrosion problem of inner steel bar embedded in concrete is very important in terms of safety and economical point of view. In this study, multiple mortar test specimen(W/C:0.4) with six types having different cover thickness each other was prepared and was immerged in seawater solution for five years to evaluate the effect of cover thickness and immersion years to corrosion property of embedded steel bar. And the polarization characteristics of these embedded steel bars was investigated using electrochemical methods such as measuring corrosion potential, cathodic polarization curve, and cyclic voltammogram. At the beginning of immersion, the corrosion potentials exhibited increasingly nobler values with increasing cover thickness. However, after immersed for 5 years, the thicker cover of thickness, the corrosion potentials shifted in the negative direction, and the relationship between corrosion potential and cover thickness was not in good agreement with each other. Therefore, it is considered that the thinner cover of thickness, corrosive products deposited on the surface of the embedded steel bar plays the role as a resistance polarization which is resulted in decreasing the corrosion rate as well as shifting the corrosion potential in the positive direction. As a result, it seemed that the evaluation which corrosion possibility of the reinforced steel would be estimated by only measuring the corrosion potential may not be a completely desirable method. Therefore, it is suggested that we should take into account various parameters, including cover thickness, passed aged years as well as corrosion potential for more accurate assessment of corrosion possibility of reinforced steel which is exposed to partially or fully in marine environment for long years.