• 제목/요약/키워드: Catheter obstruction

검색결과 45건 처리시간 0.022초

Catheter Obstruction of Intrathecal Drug Administration System -A Case Report-

  • Rhee, Seok-Myeon;Choi, Eun-Joo;Lee, Pyung-Bok;Nahm, Francis Sahn-Gun
    • The Korean Journal of Pain
    • /
    • 제25권1호
    • /
    • pp.47-51
    • /
    • 2012
  • Intrathecal drug administration system (ITDAS) can reduce the side effects while increasing the effectiveness of opioids compared to systemic opioid administration. Therefore, the use of ITDAS has increased in the management of cancer pain and chronic intractable pain. Catheter obstruction is a serious complication of ITDAS. Here, we present a case of catheter obstruction by a mass formed at the side hole and in the lumen. A 37-year-old man suffering from failed back surgery syndrome received an ITDAS implantation, and the ITDAS was refilled with morphine every 3 months. When the patient visited the hospital 18 months after ITDAS implantation for a refill, the amount of delivered morphine sulfate was much less than expected. Movement of the pump rotor was examined with fluoroscopy; however, it was normal. CSF aspiration through the catheter access port was impossible. When the intrathecal catheter was removed, we observed that the side hole and lumen of the catheter was plugged.

악성 담관 폐쇄 환자에서 경피경간 담도 배액술의 유증상 이탈 발생의 예측 인자 (Predictive Factors for Symptomatic Dislodgement of Percutaneous Transhepatic Biliary Drainage Catheter in Patients with Malignant Biliary Obstruction)

  • 유희정;박정구;정규식;서광일;박현준;윤종혁
    • 대한영상의학회지
    • /
    • 제84권6호
    • /
    • pp.1350-1360
    • /
    • 2023
  • 목적 악성 담관 폐쇄 환자에서 경피경간 담도 배액술을 시행할 때 유증상 이탈을 유발하는 예측 인자에 대해 연구를 진행하고자 한다. 대상과 방법 2010년 1월부터 2015년 2월까지 572명의 악성 담관 폐쇄 환자에서 시행한 733건의 경피경간 담도 배액술을 대상으로 후향적 연구를 시행하였다. 카테터의 거치 기간, 접근 위치, 카테터 팁의 위치, 삽입 각도, 피그테일 루프의 유무, 도관 직경을 평가하였다. 결과 추적관찰 기간 동안 157명의 환자에서 224건(30.56%)의 도관 이탈이 발생하였다. 그중 146건(19.92%)가 유증상 도관 이탈이었다. 배액관 이탈 발생까지의 기간은 평균 30일(범위: 1-159일)이었다. 유증상 도관 이탈은 배액관의 교체(137명) 또는 담관 스텐트 삽입(9명)을 통해 치료하였다. 남성(교차비: 1.636, 95% 신뢰구간: 1.131-2.367, p = 0.009), 우측 접근(교차비: 1.567, 95% 신뢰구간: 1.080-2.274, p = 0.018), 도관 삽입 각도 증가(교차비: 1.015, 95% 신뢰구간: 1.005-1.026, p = 0.005), 불완전 피그테일 루프(교차비: 1.672, 95% 신뢰구간: 1.098-2.545, p = 0.016)가 독립적인 경피경간 담도 배액술 도관 유증상 이탈의 예측 인자였다. 결론 유증상 이탈을 유발하는 예측인자에는 남성, 우측 접근, 도관 삽입 각도 증가, 불완전 피그테일 루프가 있다.

혈관 삽입형 초소형 작동형 내시경의 개발(I) - 도뇨관 삽입시 혈관 내부의 윤활 특성 분석 - (Development of Intravascular Micro Active Endoscope(I) -Analysis of Lubrication Characteristics of Small Arteries with Micro Catheter Insertion-)

  • 장준근;김중경
    • Tribology and Lubricants
    • /
    • 제15권3호
    • /
    • pp.272-277
    • /
    • 1999
  • The objective of this investigation is to examine the influence of the micro catheters, which mimic the intravascular micro active endoscopes, on local pressure changes and flow rate in an arterial branch model similar to the femoral artery of human. The effects of branch to main lumen flow rate ratios and the locations of a catheter tip were found to be significant on the local pressure changes. Relatively large pressure drops and an increase in shear stress due to the obstruction effects may induce an endothelial cell damage and a change in arterial wall permeability, which have been reported to be the primary cause of the initiation of the atherosclerosis and other major vascular diseases.

Usefulness of nasal cavity evaluation before high-resolution esophageal manometry in high-risk patients

  • Hyun Jin Min;Jae Yong Park
    • The Korean journal of internal medicine
    • /
    • 제39권1호
    • /
    • pp.86-94
    • /
    • 2024
  • Background/Aims: A catheter is inserted through the nasal cavity during high-resolution esophageal manometry (HRM), which may cause adverse events such as pain or epistaxis. Despite these possible safety considerations, studies on this subject are very limited. We aimed to investigate the usefulness of nasal cavity evaluation before HRM to reduce the risk of adverse events and test failure. Methods: Patients who underwent HRM after consultation with the ear-nose-throat department for nasal evaluation were retrospectively enrolled between December 2021 and May 2022. The included patients had a previous history of sinonasal disease or surgery or had subjective nasal discomfort. All patients answered the Sino-Nasal Outcome Test (SNOT-22) questionnaire, and subjective nasal discomfort was scored using a visual analog scale. Nasal endoscopy and acoustic rhinometry were performed for disease evaluation and volumetric assessment. Results: The analysis included 22 patients with a mean age of 58.9 years. The mean SNOT-22 score was 24.2, and 16 patients (72.7%) complained of subjective nasal obstruction. The HRM catheter was successfully inserted in 20 patients (90.9%), without any significant adverse events. The objective measurement outcomes of acoustic rhinometry and sinus endoscopy did not always correspond to subjective symptoms. Narrowed nasal airways unresponsive to decongestants were observed in two patients with failed catheter insertion. Conclusions: To reduce the risk of adverse events and test failure during HRM, a site-specific questionnaire to evaluate nasal obstruction might be helpful. When nasal obstruction is suspected, objective nasal cavity evaluation could be recommended for the safe and successful performance of HRM.

소아 환자에서 복강경 복막 투석관 삽입술과 개복 삽입술의 비교 (Comparison of the Laparoscopic and Open Peritoneal Dialysis Catheter Insertion in Children)

  • 김현수;정수민;이석구;서정민
    • Advances in pediatric surgery
    • /
    • 제17권2호
    • /
    • pp.125-132
    • /
    • 2011
  • The aim of this study was to compare peritoneal dialysis catheter insertion by the open method to the laparoscopic method. Twenty four laparoscopic and 10 open peritoneal dialysis catheter placements were performed in children between 2001 and 2008. Patient characteristics, operation related data, procedural complications and clinical outcome were compared. Although there were no cases of catheter obstruction, exit site infection or bleeding in the laparoscopic group, compared to the open method, there was no statistically significant difference between the two groups. Catheter removal rate due to complication was high in the open group and catheter survival rate was high in the laparoscopic group. We concluded that laparoscopic peritoneal dialysis catheter placement is feasible in children of all age groups with at least equivalent functional results compared to the open method. An advantage of laparoscopic catheter insertion is removal of the great omentum and easy fixation of the catheter to the abdominal wall.

  • PDF

혈액투석 환자의 도관 기능부전 관리 프로토콜 적용이 도관개존 성공률 및 출혈 합병증에 미치는 영향 (Effect of Evidence-Based Practice Protocol for Catheter Dysfunction in Hemodialysis Patients: Focus on Patency Rates and Bleeding Complications)

  • 이경미;김미연
    • 임상간호연구
    • /
    • 제24권3호
    • /
    • pp.356-362
    • /
    • 2018
  • Purpose: This study was a retrospective cohort study to evaluate the effect of evidence-based guidelines for catheter dysfunction among hemodialysis patients, Success rate and bleeding complications in catheterization were examined. Methods: We performed a retrospective cohort study, including 94 patients with catheter dysfunction who were receiving hemodialysis at a university hospital; 55 in the control group and 39 in the protocol group. This protocol was composed of the catheter dysfunction assessment, conservative management of catheter dysfunction, drug management of catheter dysfunction, catheter function test and maintenance management. Data were analyzed with a Chi-square test and t-test using SPSS/WIN 23.0 program. Results: The patency rate of the protocol group was significantly higher than that of the control group. The rate of bleeding complications was not statistically significant for either the control group or the protocol group before or after application. Conclusion: The application of the guidelines effectively increased the patency rate of the catheter without bleeding complications. It is hoped that this guideline can be disseminated to nurses nationwide to improve the efficiency of catheter function for hemodialysis patients.

Changes of Blood Flow Characteristics due to Catheter Obstruction during the Coronary Angioplasty

  • Suh, Sang-Ho;Roh, Hyung-Woon;Kwon, Hyuck-Moon;Lee, Byoung-Kwon
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제2권1호
    • /
    • pp.25-30
    • /
    • 2004
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Uses of catheters during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. Catheters in blood vessels cause pressure gradient rise and blood flow drop during the measurements. In this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter obstructions during the coronary angioplasty. The computer simulation models are generated by the data, which are measured by coronary angiogram, and the blood is treated as non-Newtonian fluid. The velocity, pressure, and wall shear stress variations are observed for the estimate of damages of blood vessel. This study is also extended to investigate the effects of stenotic vessel size, and shape and catheter size and location.

  • PDF

Deep vein thrombosis caused by malignant afferent loop obstruction

  • Kang, Eun Gyu;Kim, Chan;Lee, Jeungeun;Cha, Min-uk;Kim, Joo Hoon;Park, Seo-Hwa;Kim, Man Deuk;Lee, Do Yun;Rha, Sun Young
    • Journal of Yeungnam Medical Science
    • /
    • 제33권2호
    • /
    • pp.166-169
    • /
    • 2016
  • Afferent loop obstruction following gastrectomy is a rare but fatal complication. Clinical features of afferent loop obstruction are mainly gastrointestinal symptoms. A 56-year-old female underwent radical total gastrectomy with Roux-en-Y esophagojejunostomy for treatment of advanced gastric cancer. After fourteen months postoperatively, she showed gradual development of edema of both legs. Computed tomography (CT) scan showed disease progression at the jejunojejunostomy site and consequent dilated afferent loop, which resulted in inferior vena cava (IVC) compression. A drainage catheter was placed percutaneously into the afferent loop through the intrahepatic duct and an IVC filter was placed at the suprarenal IVC, and self-expanding metal stents were inserted into bilateral common iliac veins. With these procedures, sympotms related with afferent loop obstruction and deep vein thrombosis were improved dramatically. The follow-up abdominal CT scan was taken 3 weeks later and revealed the completely decompressed afferent loop and improved IVC patency. Surgical treatment should be considered as the first choice for afferent loop obstruction; however, because it is more immediate and less invasive, non-surgical modalities, such as percutaneous catheter drainage or stent placement, can be effective alternatives for inoperable cases or risky patients who have severe medical comorbidities.

뇌실-복강 단락 원위도관의 심장내전위 - 증례보고 - (A Case of Intracardiac Migration of Distal Ventriculo-Peritonal(V-P) Shunt Catheter - Case Report -)

  • 김병주;차승헌;박동준;송근성;최창화;이영우
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권2호
    • /
    • pp.270-273
    • /
    • 2000
  • Ventriculoperitoneal(V-P) shunt has been used as a popular method for surgical treatment of hydrocephalus. But complications such as infection, mechanical obstruction and failure of flow rate sometimes make painful stress to neurosurgeons and patients. Of particular, migration of distal V-P shunt catheter to extraperitoneal space has rarely been reported. Even rarer is intracardiac migration of distal V-P shunt catheter. Authors report a such case and discuss the possible mechanism and preventive method.

  • PDF

Fogarty 카테터를 이용한 식도 이물(바둑알) 제거 2예 (Two Cases of esophageal foreign body removal using Fogarty catheter)

  • 박시내;박경호;박준욱;여상원;조승호
    • 대한기관식도과학회지
    • /
    • 제9권1호
    • /
    • pp.79-82
    • /
    • 2003
  • Unintentional foreign body ingestion is common in children, and coins are the most common foreign body ingested. Foreign body remaining in the esophagus may be associated with mucosal ulceration or esophageal obstruction and can potentially lead to significant morbidity and even death. Removal of esophageal foreign body is therefore generally recommended. Several methods are utilized including esophagoscopy in operating room, flexible endoscopy in out patient setting, fluoroscopic Foley catheter technique, and advancement using bougienage. We report two cases of esophageal foreign body(paduk stone) which were hard to be removed by usual esophagoscopic removal. Successful removal was accomplished with the aid of Fogarty catheter under the general anesthesia.

  • PDF