• 제목/요약/키워드: Catastrophic Failure

검색결과 186건 처리시간 0.027초

특정소방대상물의 공기호흡기 안전규제 개선방안 (Improving the Safety Regulation For Self Contained Breathing Apparatus)

  • 이상팔
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.45-51
    • /
    • 2010
  • 본 논문은 공기호흡기 사용실패 유형과 원인을 생산자에 대한 정부규제와 고객에 대한 정부규제의 문제점을 중심으로 분석한다. 전자의 경우 용기 및 공기호흡기의 안전검사 기준의 한계점 분석이고, 후자의 경우 사용자관리자의 유지관리 및 폐기처분 규정의 한계점 분석이다. 개선방안으로는 수거검사와 수집검사를 확대, 폐용기 처리 결과 감시확인 절차의 투명성 강화 등이 있다.

Fracture Behavior of Silicon Nitride-silicon Carbide-boron Nitride Multi-layer Composites with Different Layer Thickness

  • Cho, Byoung-Uk;Park, Dong-Soo;Park, Hong-Chae
    • 한국세라믹학회지
    • /
    • 제39권7호
    • /
    • pp.622-627
    • /
    • 2002
  • Multi-layer composites consisting of silicon nitride, silicon nitride-silicon carbide and boron nitride-alumina layers were prepared fly stacking the corresponding ceramic tapes. The composites demonstrated self-diagnostic capability and non-catastrophic failure behavior. The composites consisting of many thin layers exhibited high strength and stepwise increase of the electrical resistance during the flexure test. The strength of the composite with too thick silicon nitride layers was low and the electrical resistance was abruptly increased to the detection limit of the digital multi-meter during the test. An extensive crack branching was observed in the weak (BN + Al$_2$O$_3$)layer.

Prediction of Outflow Hydrograph caused by Landslide Dam Failure by Overtopping

  • Do, XuanKhanh;Kim, Minseok;Nguyen, H.P.T;Jung, Kwansue
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.196-196
    • /
    • 2016
  • Landslide dam failure presents as a severe natural disaster due to its adverse impact to people and property. If the landslide dams failed, the discharge of a huge volume of both water and sediment could result in a catastrophic flood in the downstream area. In most of previous studies, breaching process used to be considered as a constructed dam, rather than as a landslide dam. Their erosion rate was assumed to relate to discharge by a sediment transport equation. However, during surface erosion of landslide dam, the sediment transportation regime is greatly dependent on the slope surface and the sediment concentration in the flow. This study aims to accurately simulate the outflow hydrograph caused by landslide dam by overtopping through a 2D surface flow erosion/deposition model. The lateral erosion velocity in this model was presented as a function of the shear stress on the side wall. The simulated results were then compared and it was coherent with the results obtained from the experiments.

  • PDF

Buckling failure of cylindrical ring structures subjected to coupled hydrostatic and hydrodynamic pressures

  • Ping, Liu;Feng, Yang Xin;Ngamkhanong, Chayut
    • Structural Monitoring and Maintenance
    • /
    • 제8권4호
    • /
    • pp.345-360
    • /
    • 2021
  • This paper presents an analytical approach to calculate the buckling load of the cylindrical ring structures subjected to both hydrostatic and hydrodynamic pressures. Based on the conservative law of energy and Timoshenko beam theory, a theoretical formula, which can be used to evaluate the critical pressure of buckling, is first derived for the simplified cylindrical ring structures. It is assumed that the hydrodynamic pressure can be treated as an equivalent hydrostatic pressure as a cosine function along the perimeter while the thickness ratio is limited to 0.2. Note that this paper limits the deformed shape of the cylindrical ring structures to an elliptical shape. The proposed analytical solutions are then compared with the numerical simulations. The critical pressure is evaluated in this study considering two possible failure modes: ultimate failure and buckling failure. The results show that the proposed analytical solutions can correctly predict the critical pressure for both failure modes. However, it is not recommended to be used when the hydrostatic pressure is low or medium (less than 80% of the critical pressure) as the analytical solutions underestimate the critical pressure especially when the ultimate failure mode occurs. This implies that the proposed solutions can still be used properly when the subsea vehicles are located in the deep parts of the ocean where the hydrostatic pressure is high. The finding will further help improve the geometric design of subsea vehicles against both hydrostatic and hydrodynamic pressures to enhance its strength and stability when it moves underwater. It will also help to control the speed of the subsea vehicles especially they move close to the sea bottom to prevent a catastrophic failure.

Unscented Filtering Approach to Magnetometer-Only Orbit Determination

  • Cheon, Yee-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2331-2334
    • /
    • 2003
  • The basic difference between the EKF(Extended Kalman Filter) and UKF(Unscented Kalman Filter) stems from the manner in which Gaussian random variables(GRV) are represented for propagating through system dynamics. In the EKF, the state distribution is approximated by a GRV, which is then propagated analytically through the first-order linearization of the nonlinear system. This can possibly introduce large errors in the true posterior mean and covariance of the transformed GRV, which may lead to sub-optimal performance and sometimes divergence of the filter. However, the UKF addresses this problem by using a deterministic sampling approach. The state distribution is also approximated by a GRV, but is now represented using a minimal set of carefully chosen sample points. These sample points completely capture the true mean and covariance of the GRV, and UKF captures the posterior mean and covariance accurately up to the 2nd order(Taylor series expansion) for any nonlinearity. This paper utilizes the UKF to determine spacecraft orbit when only magnetometer is available. Several catastrophic failures of spacecraft in orbit have been attributed to failures of the spacecraft mission. Recently studies on contingency-major sensor failure cases- have been performed. For mission success, contingency design or plan should be implemented in case of a major sensor failure. Therefore the algorithm presented in this paper can be used for a spacecraft without GPS or contingency design in case of GPS failure.

  • PDF

Large Steel Tank Fails and Rockets to Height of 30 meters - Rupture Disc Installed Incorrectly

  • Hedlund, Frank H.;Selig, Robert S.;Kragh, Eva K.
    • Safety and Health at Work
    • /
    • 제7권2호
    • /
    • pp.130-137
    • /
    • 2016
  • At a brewery, the base plate-to-shell weld seam of a $90-m^3$ vertical cylindrical steel tank failed catastrophically. The 4 ton tank "took off" like a rocket leaving its contents behind, and landed on a van, crushing it. The top of the tank reached a height of 30 m. The internal overpressure responsible for the failure was an estimated 60 kPa. A rupture disc rated at < 50 kPa provided overpressure protection and thus prevented the tank from being covered by the European Pressure Equipment Directive. This safeguard failed and it was later discovered that the rupture disc had been installed upside down. The organizational root cause of this incident may be a fundamental lack of appreciation of the hazards of large volumes of low-pressure compressed air or gas. A contributing factor may be that the standard piping and instrumentation diagram (P&ID) symbol for a rupture disc may confuse and lead to incorrect installation. Compressed air systems are ubiquitous. The medium is not toxic or flammable. Such systems however, when operated at "slight overpressure" can store a great deal of energy and thus constitute a hazard that ought to be addressed by safety managers.

Failure pattern of large-scale goaf collapse and a controlled roof caving method used in gypsum mine

  • Chen, Lu;Zhou, Zilong;Zang, Chuanwei;Zeng, Ling;Zhao, Yuan
    • Geomechanics and Engineering
    • /
    • 제18권4호
    • /
    • pp.449-457
    • /
    • 2019
  • Physical model tests were first performed to investigate the failure pattern of multiple pillar-roof support system. It was observed in the physical model tests, pillars were design with the same mechanical parameters in model #1, cracking occurred simultaneously in panel pillars and the roof above barrier pillars. When pillars 2 to 5 lost bearing capacity, collapse of the roof supported by those pillars occurred. Physical model #2 was design with a relatively weaker pillar (pillar 3) among six pillars. It was found that the whole pillar-roof system was divided into two independent systems by a roof crack, and two pillars collapse and roof subsidence events occurred during the loading process, the first failure event was induced by the pillars failure, and the second was caused by the roof crack. Then, for a multiple pillar-roof support system, three types of failure patterns were analysed based on the condition of pillar and roof. It can be concluded that any failure of a bearing component would cause a subsidence event. However, the barrier pillar could bear the transferred load during the stress redistribution process, mitigating the propagation of collapse or cutting the roof to insulate the collapse area. Importantly, some effective methods were suggested to decrease the risk of catastrophic collapse, and the deep-hole-blasting was employed to improve the stability of the pillar and roof support system in a room and pillar mine.

강바닥판 데크플레이트와 종리브 현장연결 스캘럽부의 피로강도 평가 (Evaluation of Fatigue Strength in Scallop at Field Bolted Joints of Longitudinal Rib and Deck Plate in Orthotropic Steel Decks)

  • 최동호;최항용
    • 한국강구조학회 논문집
    • /
    • 제14권6호
    • /
    • pp.683-690
    • /
    • 2002
  • 본 연구에서는 국내에 적용된 강바닥판의 데크플레이트와 종리브 현장 연결 스캘럽부의 구조상세를 검토하고 실험체를 제작하여 정적재하실험 및 피로실험을 실시하였다. 또한 FEM 해석을 통하여 스캘럽 길이, 스캘럽 곡률반경, 데크플레이트 두께 등과 같은 매개변수가 종리브 스캘럽부의 응력에 미치는 영향을 살펴보았으며, 이를 통하여 스캘럽부에 대한 S-N선도를 추정하였다. 피로실험을 수행한 결과, 낮은 응력수준에서는 스캘럽부에서 피로균열이 발생하였고, 높은 응력수준에서는 핸드홀 덮개판의 파괴 후에 종리브의 갑작스런 파괴가 일어났다. 피로실험결과를 JSSC 피로등급과 Shigley와 Juvinall이 제안한 방법에 의한 피로강도와 비교검토한 결과, 데크플레이트와 종리브 현장연결 스캘럽부는 규정된 피로등급를 만족하였다.

Development of a nonlinear seismic response capacity spectrum method for intake towers of dams

  • Cocco, Leonardo;Suarez, Luis E.;Matheu, Enrique E.
    • Structural Engineering and Mechanics
    • /
    • 제36권3호
    • /
    • pp.321-341
    • /
    • 2010
  • The seismic-induced failure of a dam could have catastrophic consequences associated with the sudden release of the impounded reservoir. Depending on the severity of the seismic hazard, the characteristics and size of the dam-reservoir system, preventing such a failure scenario could be a problem of critical importance. In many cases, the release of water is controlled through a reinforced-concrete intake tower. This paper describes the application of a static nonlinear procedure known as the Capacity Spectrum Method (CSM) to evaluate the structural integrity of intake towers subject to seismic ground motion. Three variants of the CSM are considered: a multimodal pushover scheme, which uses the idea proposed by Chopra and Goel (2002); an adaptive pushover variant, in which the change in the stiffness of the structure is considered; and a combination of both approaches. The effects caused by the water surrounding the intake tower, as well as any water contained inside the hollow structure, are accounted for by added hydrodynamic masses. A typical structure is used as a case study, and the accuracy of the CSM analyses is assessed with time history analyses performed using commercial and structural analysis programs developed in Matlab.

전단파괴가 발생한 기둥의 이력거동 예측을 위한 매개변수 결정방법 제안 (Calibration Methodology for Predicting Hysteretic Behavior of Reinforced Concrete Columns Failed in Shear)

  • 이창석;한상환;고길보
    • 한국지진공학회논문집
    • /
    • 제21권1호
    • /
    • pp.41-48
    • /
    • 2017
  • Columns in existing reinforced concrete structures that are designed and constructed without considering seismic loads generally exhibit widely spaced transverse reinforcements without using seismic hooks. Due to the insufficient reinforcement details in columns compared to the reinforcement requirements specified in modern seismic codes, brittle shear failure is likely to occur. This may lead to sudden collapse of entire structure during earthquakes. Adequate retrofit strategy is required for these columns to avoid such catastrophic event. In order to do so, behavior of columns in existing reinforced concrete structures should be accurately predicted through computational analysis. In this study, an analytical model is proposed for accurately simulating the cyclic behavior of shear critical columns. The parameters for backbone, as well as pinching and cyclic deterioration in strength and stiffness are calibrated using test data of column specimens failed by shear.