• Title/Summary/Keyword: Cast method

Search Result 827, Processing Time 0.032 seconds

Shear Strength of Prestressed PC-CIP Composite Beams without Vertical Shear Reinforcements (수직전단보강이 없는 PS 콘크리트와 현장타설 콘크리트 합성보의 전단강도)

  • Kim, Chul-Goo;Park, Hong-Gun;Hong, Geon-Ho;Kang, Su-Min;Suh, Jung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.533-543
    • /
    • 2014
  • Currently, composite construction of prestressed Precast Concrete (PC) and Cast-In-Place (CIP) concrete with different concrete strengths are frequently used in the modular construction. However, current design codes do not clearly define shear design methods for such composite beams. In this present study, simply supported prestressed PC-CIP composite beams without vertical shear reinforcement or only with horizontal shear reinforcement were tested to evaluate the effect of prestressing on the shear strength and the shear design method for such composite members. The test variables were the area ratio of PC and CIP concretes, prestressing force, shear span-to-depth ratio, and shear reinforcement ratio. The results showed that the shear strength was increased by the increase of prestressing force and prestressed PC area, and the decrease of shear span-to-depth ratio.

Characteristics of the Cyclic Hardening in Low Cycle Environmental Fatigue Test of CF8M Stainless Steel (CF8M 스테인리스 강 저주기 환경피로 실험의 주기적 변형률 경화 특성)

  • Jeong, Ill-Seok;Ha, Gak-Hyun;Kim, Tae-Ryong;Jeon, Hyun-Ik;Kim, Yeong-Sin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.17-22
    • /
    • 2007
  • Low-cycle environmental fatigue tests of cast austenitic stainless steel CF8M at the condition of fatigue strain rate 0.04%/sec were conducted at the pressure and temperature, 15MPa, $315^{\circ}C$ of a operating pressurized water reactor. The used test rig was limited to install an extensometer at the gauge length of the cylindrical fatigue specimen inside the small autoclave. So the magnet type LVDT's were used to measure the fatigue displacement at the specimen shoulders inside the high temperature and high pressure water autoclave. However, the displacement and strain measured at the specimen shoulders is different from the one at the gauge length for the geometry and the cyclic strain hardening effect. FEM calculated the displacement and the strain of the gauge length from the data measured at the shoulders. Tensile test properties in elastic and plastic behavior of CF8M material were used in the FEM analysis. A series of low cycle fatigue tests simulating the cyclic strain hardening effect verified that the FEM calculation was well agreed with the simulated tests. The process and method developed in this study would be so useful to produce reliable environmental fatigue curves of CF8M stainless steel in pressurized water reactors.

  • PDF

A Clinical Study on the Fractures of the Femoral Neck in Children (소아 대퇴골 경부골절의 임상적 고찰)

  • Kim, Se-Dong;Ihn, Joo-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 1988
  • Fractures of the femoral neck in children are rare and usually the result of severe trauma. The femoral necks in children, in contrast to those of adults, have many anatomic and physiologic differences. Among the late complications encountered are avascular necrosis, coxa vara, premature closure of the proximal capital femoral epiphysis and nonunion. In spite of careful management, significant complication rate often results. Nine cases of fractures of the femoral neck in children which were treated at Yeungnam University Hospital from June 1984 to August 1987 were reviewed. The results obtained are as follows: 1. The main causes of fractures were traffic accidents(5 cases). 2. Among 9 patients, 6 were girls and 3 were boys. 3. According to the classification of Delbet and Colonna, the transcervical fracture(6 cases) was the commonest type. 4. 4 cases were treated by closed reduction and internal fixation, 3 cases were treated by open reduction and internal fixation. 2 cases were treated by skin traction and cast. 5. The results were analyzed according to Ratliff's assessment. 6 cases showed good results, and 3 cases showed poor results. 6. Early diagnosis and good fixation method seemed to be vital to prognosis.

  • PDF

Effect of Cu Addition on Thermal Properties of Mg-6Zn-xCu alloys (Mg-6Zn-xCu 합금의 열적 특성에 미치는 Cu 첨가의 영향)

  • Ye, Dea-Hee;Kim, Hyun-Sik;Kang, Min-Cheol;Jeong, Hae-Yong
    • Journal of Korea Foundry Society
    • /
    • v.35 no.4
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, Mg-Zn alloys are investigated in terms of their thermal properties after an addition of Cu. Al element is added to improve the mechanical properties and castability in general case. However, it was excluded here because it significantly decreases the thermal conductivity. On the other hand, Zn was added as a major element, which had less influence on reducing the conductivity and can complement the mechanical properties as well. Cu was also added, and it improved the heat transfer characteristics as the amount was increased. The composition ranges of Zn and Cu are 6 wt.% and 0~1.5 wt.%, respectively. Mg-6Zn-xCu alloy was prepared by a gravity casting method using a steel mold and then the thermal conductivity and the microstructure of the as-cast material were investigated. By measuring the density_(${\rho}$), specific heat_(Cp) and thermal diffusivity_(${\alpha}$), the thermal conductivity_(${\lambda}$) was calculated by the equation ${\lambda}={\rho}{\cdot}Cp{\cdot}{\alpha}$. As the amount of Cu increased in the Mg-6Zn-xCu alloy, the heat transfer characteristics were improved, resulting in a synergistic effect which is slow when the added Cu exceeds 1 wt.%. In order to investigate the relative thermal conductivity/emission of the Mg-6Zn-xCu alloy, AZ91 and AZ31 were experimentally evaluated and compared using a separate test equipment. As a result, the Mg-6Zn-1.5Cu alloy when compared to AZ91 showed improvements in the thermal conductivity ranging from 30 to 60% with a nearly 20% improvement in the thermal emission.

Failure Analysis of Cracks in Ancient and Modern Bronze Spoons (고대와 현대 방짜수저의 균열발생 원인분석)

  • Choe, Byung Hak;Lee, Bum Gyu;Shim, Jong Hun;Go, Hyung Soon;Jo, Nam Chul;Lee, Jae Sung;Park, Kyung Gyun;Kim, Yu Chan
    • Korean Journal of Materials Research
    • /
    • v.26 no.10
    • /
    • pp.528-534
    • /
    • 2016
  • The aim of this paper is to consider the effect of the manufacturing processes on corrosion and centerline cracking of ancient bronze spoons. The ancient bronze spoons in question were made by several steps of forging, in reheated condition with cast ingots. The manufacturing method is similar to that of the modern spoons. The investigations include observations from light and scanning electron microscopes of the microstructure in terms of the crack propagation. Cracks in the centerline are caused by solute segregation in the center-line region; this solute is solidified in the final stage of bronze spoon manufacture. Centerline cracking is also caused by ${\alpha}$ phase segregation, accompanied by forged overlapping along the longitudinal direction of the spoons. A vertical stripe with cracks along the centerline of the spoon's width is formed by folding in the wrought process. The overlapping area causes crack propagation with severe corrosion on the spoon surfaces over a period of a thousand years. The failure mechanisms of ancient bronze spoons may be similar to that of modern spoons, and the estimation of the failure mechanisms of ancient spoons can be appropriate to determine failure causes for such modern spoons.

Effect of Alloying Element Addition on the Microstructure, Tensile and Impact Toughness of the Modified Al-6.5Si Alloy (개량 Al-6.5Si 합금의 미세조직, 인장 및 충격 인성에 미치는 합금 원소 첨가의 영향)

  • Park, T.H.;Baek, M.S.;Yoon, S.I.;Kim, J.P.;Lee, K.A.
    • Transactions of Materials Processing
    • /
    • v.29 no.3
    • /
    • pp.135-143
    • /
    • 2020
  • Low-cost alloying elements were added to a modified Al-6.5Si alloy and its microstructure, tensile and impact toughness properties were investigated. The alloying elements added were Mg, Zn, and Cu, and two kinds of alloy A (Mg:0.5, Zn:1, Cu:1.5 wt.%) and alloy B (Mg:2, Zn:1.5, Cu:2 wt.%) were prepared. In the as-cast Al-6.5Si alloys, Si phases were distributed at the dendrite interfaces, and Al2Cu, Mg2Si, Al6 (Fe,Mn) and Al5 (Fe,Mn)Si precipitates were also observed. The size and fraction of casting defects were measured to be higher for alloy A than for alloy B. The secondary dendrite arm spacing of alloy B was finer than that of alloy A. It was confirmed by the JMatPro S/W that the cooling rate of alloy B could be more rapid than alloy A. The alloy B had higher hardness and strength compared to the values of alloy A. However, the alloy A showed better impact toughness than alloy B. Based on the above results, the deformation mechanism of Al-6.5Si alloy and the improving method for mechanical properties were also discussed.

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

A comparison of retentive strength of implant cement depending on various methods of removing provisional cement from implant abutment

  • Keum, Eun-Cheol;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.234-240
    • /
    • 2013
  • PURPOSE. This study evaluated the effectiveness of various methods for removing provisional cement from implant abutments, and what effect these methods have on the retention of prosthesis during the definitive cementation. MATERIALS AND METHODS. Forty implant fixture analogues and abutments were embedded in resin blocks. Forty cast crowns were fabricated and divided into 4 groups each containing 10 implants. Group A was cemented directly with the definitive cement (Cem-Implant). The remainder were cemented with provisional cement (Temp-Bond NE), and classified according to the method for cleaning the abutments. Group B used a plastic curette and wet gauze, Group C used a rubber cup and pumice, and Group D used an airborne particle abrasion technique. The abutments were observed using a stereomicroscope after removing the provisional cement. The tensile bond strength was measured after the definitive cementation. Statistical analysis was performed using one-way analysis of variance test (${\alpha}$=.05). RESULTS. Group B clearly showed provisional cement remaining, whereas the other groups showed almost no cement. Groups A and B showed a relatively smooth surface. More roughness was observed in Group C, and apparent roughness was noted in Group D. The tensile bond strength tests revealed Group D to have significantly the highest tensile bond strength followed in order by Groups C, A and B. CONCLUSION. A plastic curette and wet gauze alone cannot effectively remove the residual provisional cement on the abutment. The definitive retention increased when the abutments were treated with rubber cup/pumice or airborne particle abraded to remove the provisional cement.

A Study on the Applicability of 3D Ceramic Printing Technology for Restoration of the Missing Part of Damaged Ceramics (훼손 도자기 결실부 복원을 위한 3D 세라믹 프린팅 기술의 기초 적용성 연구)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.165-173
    • /
    • 2020
  • ABS and PLA are applied for restoring missing part of damaged ceramics, but are not similar to the material of ceramics, so this study conducted a research on the properties and applicability of ceramic resin. This study conducted actual restoration of ABS and ceramic resin as well as cast restoration method with experiment of properties. Results show that manufacturing of restored part showed higher precision than existing materials, which enables printing of tiny shapes showing excellent surface texture and gloss than L30 and ABS resin. As a result of measuring properties, the material showed excellent durability than existing materials with no contraction and deformation and compressive strength, but value of specific gravity and hardness can lower processability after manufacturing. Long-term monitoring, evaluation of reliability of ceramic resin applied in this study, additional researches on the restorability of the original shape when printing too thin or long restored part are needed.

Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician (치과기공사국가시험 문항개발기준안연구)

  • Lee, Duck-Hye;Chung, In-Sung;Han, Chang-Sik
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF