• Title/Summary/Keyword: Case-2 water

Search Result 3,853, Processing Time 0.034 seconds

Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream - (수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 -)

  • 허인량;정의호;권재혁
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

Removal of Procymidone by Ozonated Water (오존수를 이용한 프로시미돈의 제거)

  • Choi, Seong-Woo;Park, Shin-Young
    • Journal of Environmental Science International
    • /
    • v.16 no.12
    • /
    • pp.1425-1430
    • /
    • 2007
  • This study was conducted to investigate the effect of ozonated water and ozonated water+hydrogen peroxide treatment of residual procymidone in perilla leaf containing 20 mg/L procymidone. Samples was treated with ozonated water containing 1.0, 2.0 and 3.0 mg $O_3/L$ ozone and hydrogen peroxide water containing 1.0, 2.0 and 3.0 mg $H_2O_2/L$ hydrogen peroxide in pH 5, 7 and 9, respectively, at $15^{\circ}C$. Procymidone removal rate was 26.5% in 7 days at $15^{\circ}C$ and optimum condition of procymidone removal was the case of treating with ozonated water containing 2.0 mg $O_3/L$ and pH 9. As the result procymidone removal rate was about 96.5%. In this case of adding hydrogen peroxide, optimum condition of procymidone removal was $1:0.5{\sim}1(O_3:H_2O_2)$. However, procymidone was nearly removed with the treatment of hydrogen peroxide water only.

Comparison of Fire Extinguishing Effects for Water Mist Additives (미분무수 첨가제의 소화효과 비교)

  • Kim, Seung Il;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.23-28
    • /
    • 2013
  • In order to improve extinguishing performance of water mist, many studies of additives have been conducted. In this study, viscosity agent which has the ability to improve extinguishing performance by adhering to the surface on fire was used and fluorine-free surfactant was also added to water to enhance water's wetting ability. This study aimed to verify optimal concentration of extinguishing of additives according to fire source and extinguishing performance by comparison with pure water. In case of wood crib fire, the results show that flame suppression and extinguishing time of sodium alginate 0.4 wt.% are 3.4 times and 2.2 times shorter than those of pure water in 0.2 MPa respectively. It seems that large amount of water adhere to surface on fire, thus cooling effect on surface was enhanced. Also water consumption of sodium alginate 0.4wt.% is up to 65% lower than that of pure water. In case of heptane fire, extinguishing time of cocobetaine 0.1 wt.% is 9.7 times shorter than that of pure water in 0.2 MPa. It is thought that because cocobetaine can block oxygen and suppress oil mist by making emulsion film on fire surface due to a low surface tension. On the other hand, water consumption of cocobetaine 0.1 wt.% is 92% lower than that of pure water.

Physico-chemical and Microbiological Analysis of Tap Water in the Apartment in Taegu City (대규모 음용수 저장시설의 수질평가)

  • Kim, Seck-Bhum;Kang, Pock-Soo;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.69-75
    • /
    • 1988
  • The drinking water in the apartment is stored in reservior tank and thereafter supplied each household. In case the drinking water is stored too long or insanitary, tap water might change in quality. This study was carried out to evaluate the physico-chemical and microbiological conditions of 36 samples of tap water of apartments compared to 18 samples of tap water of independence houses in Taegu City from May to October, 1987. Main findings are summarized as follows : PH values were within normal range in all samples. Samples less than 0.2ppm in residual chlorine accounted for 16.7% in the appartment and 5.6% in the independence house. Nitrite nitrogen was detected 2.8% of apartment samples only. Among the total of 54 samples, 11.1% of the apartment and independence samples were over the normal value in standard plate count. Samples more than 1.8 of most probable number(MPN) accounted for 27.8% in the apartment and 33.3% in the independence house. In result of test for residual chlorine, nitrite nitrogen, standard plate count, and MPN, the proportion of the samples revealed inappropriated in respect of drinking water standards. In case of all sorts of tests was 2.7% in apartment and nothing in independence houses, in case of 3 sorts of tests was 2.7% in apartment and 5.6% in independence houses, in case of 2 sorts of tests was 8.3% in apartment and 5.6% in independence houses, and in case of only 1 test was 25.0% in apartment and 22.2% in independence houses. Correlation between residual chlorine and standard plate count, and between standard plate count and MPN were observed. It was found that the more years since construction of apartment were, the worse tap water was in quality.

  • PDF

Surgical correction of funnel chest (누두흉 치험 2예)

  • 한균인
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.226-230
    • /
    • 1983
  • Two patients with funnel chest deformity were corrected at the Department of Thoracic Surgery of Chungnam National University Hospital . The first case was 11 year old boy, suffering from exertional dyspnea with asymmetrical funnel chest deformity, of which hollow cavity was measured 80 ml of water. The second case was 6 year old boy, suffering from frequent upper respiratory tract infection with symmetrical funnel chest deformity, of which hollow cavity was measured 50 ml of water. These two cases were corrected by Ravitch method, left lower lobectomy was performed concurrently on the first case. The result was satisfactory.

  • PDF

Analysis of Agricultural Water Distribution Systems for the Utilization of Water-Demand-Oriented Water Supply Systems (물수요 중심 용수공급시스템 활용을 위한 국내 농업용수 공급체계 분석)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Current Research on Agriculture and Life Sciences
    • /
    • v.31 no.2
    • /
    • pp.139-147
    • /
    • 2013
  • This study analyzed agricultural water distribution systems for the utilization of water demand-oriented water supply systems. Three major TM/TC(telemeter/telecontrol) districts of agricultural water management were selected for analyzing the characteristics of the water distribution systems. In addition, the characteristics of the water supply systems for general water supply zones based on irrigation facilities were also investigated, along with the case of special water management during the drought season. As a result, high annual and monthly variations were observed for the water supply facilities, including the reservoirs and pumping stations. In particular, these variations were more obvious during the drought season, depending on the type of facility. The operations of the pumping stations and weirs were more sensitive to the stream levels than the reservoirs, and the smaller reservoirs were influenced more than the larger reservoirs. Therefore, a water-demand-oriented water supply system should consider the existing general practices of water management in the agricultural sector, and focus on achieving a laborsaving system rather than water conservation in the case of reservoirs. Equal water distribution from the start to the end point of irrigation channels could be an effective solution for managing pumping stations.

  • PDF

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

Relative Sensitivity Analysis of the Soil Water Characteristics Curve

  • Eom, Ki-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.6
    • /
    • pp.712-723
    • /
    • 2015
  • This study was conducted to develop the SWCC estimation equation using scaling technique, and to investigate relative sensitivity of the SWCC according to the soil water tension, for the four kinds of soil texture such as Sand [S], Sandy Loam [SL], Loam [L] and Clay Loam [CL]. The SWCC estimation equation of scale factor [${\Theta}sc$] (Eq. 1) was developed based on the log function (Eq. 2) and exponential function (Eq. 3). ${\Theta}sc=[({\Theta}-{\Theta}r)/({\Theta}s-{\Theta}r)]$ (Eq. 1) ${\Theta}sc=-0.196ln(H)+0.4888$ (Eq. 2) ${\Theta}sc=0.3804(H)^{(-0.448)}$ (Eq. 3) where, ${\Theta}$: water content (g/g %), ${\Theta}s$: water content at 0.1bar, ${\Theta}r$: water content at 15bar, H: soil water tension (matric potential) (bar) Relative sensitivity of soil water content was decreased as increase soil water tension, those according to soil water tension were 0.952~0.620 compared to 0.1bar case. Relative sensitivity of scale factor was also decreased as increase soil water tension, those according to soil water tension were 0.890~0.577 compared to 0.2bar case.

A study on the Plumbing system noise of closet bowl by water supply pressure (급수압에 따른 대변기 설비소음에 관한 연구)

  • Kim, Hang;Choi, Eun-Suk;Ko, Kwang-Pil;Gl, No-Gab;Lee, Tai-Gang;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.11-16
    • /
    • 2006
  • It appraises that use an indoor noise standard, a NC value which is a noise appraisal, a dB(A) value, a N value in foreign country because it doesn't yet ready an appraisal standard in domestic. Also, It appraises that the supply and drainage noise which could change water supply pressure, $4kg/cm^2,\;3kg/cm^2,\;2kg/cm^2,\;1.5kg/cm^2,\;1kg/cm^2$, bring about a noise and inquires how does noise level indicates according to each instruments. In case of a water supply pressure standard, $3kg/cm^2$, a C-605is $3{\sim}5dB(A)$ lower than another instruments in directly overhead stories. It appears that all of them is similar to level in directly under level except c-407(2)Analyzed the NC value, c-605is the lowest level, NC-50, of a water supply pressure, $4.0kg/cm^2$, c-407 is the highest level, NC-55.(3) In case of N value, which is one of water supply methods in Japan, it is the lowest level, N-55, of a water supply pressure, $4.0kg/cm^2$ same as NC value and C-407is the highest level, N-60.(4) In case of water supply that is likely to noise level, It appears 6dB(A) level gap each instruments, and C-605 is the lowest level, 63.9dB(A).

  • PDF