• Title/Summary/Keyword: Cascade effect

Search Result 260, Processing Time 0.027 seconds

Preliminary study on car detection and tracking method using surveillance camera in tunnel environment for accident detection (터널 내 유고상황 자동 판정을 위한 선행 연구: CCTV를 이용한 차량의 탐지와 추적 기법 고찰)

  • Oh, Young-Sup;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.813-827
    • /
    • 2017
  • Surveillance cameras installed in tunnels capture the various video frames effected by dynamic and variable factors. In addition, localizing and managing the cameras in tunnel is not affordable, and quality of capturing frame is effected by time. In this paper, we introduce a new method to detect and track the vehicles in tunnel by using surveillance cameras installed in a tunnel. It is difficult to detect the video frames directly from surveillance cameras due to the motion blur effect and blurring effect on lens by dirt. In order to overcome this difficulties, two new methods such as Differential Frame/Non-Maxima Suppression (DFNMS) and Haar Cascade Detector to track cars are proposed and investigated for their feasibilities. In the study, it was shown that high precision and recall values could be achieved by the two methods, which then be capable of providing practical data and key information to an automatic accident detection system in tunnels.

Heat/Mass Transfer Characteristics on Stationary Turbine Blade and Shroud in a Low Speed Annular Cascade (II) - Tip and Shroud - (환형 캐스케이드 내 고정된 터빈 블레이드 및 슈라우드에서의 열/물질전달 특성 (II) - 끝단 필 슈라우드 -)

  • Lee Dong-Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.495-503
    • /
    • 2005
  • Experiments were conducted in a low speed stationary annular cascade to investigate local heat transfer characteristics on the tip and shroud and the effect of inlet Reynolds number on the tip and shroud heat transfer. Detailed mass transfer coefficients on the blade tip and the shroud were obtained using a naphthalene sublimation technique. The turbine test section has a single stage composed of sixteen guide vanes and blades. The chord length and the height of the tested blade are 150 mm and about 125 mm, respectively. The blade has flat tip geometry and the mean tip clearance is about $2.5{\%}$of the blade chord. The inlet flow Reynolds number based on chord length and incoming flow velocity is changed from $1.0{\times}10^{5}\;to\;2.3{\times}10^{5}.$ to investigate the effect of Reynolds number. Flow reattachment after the recirculation near the pressure side edge dominates the heat transfer on the tip surface. Shroud surface has very intricate heat/mass transfer distributions due to complex flow patterns such as acceleration, relaminarization, transition to turbulent flow and tip leakage vortex. Heat/mass transfer coefficient on the blade tip is about 1.7 times as high as that on the shroud or blade surface. Overall averaged heat/mass transfer coefficients on the tip and shroud are proportional to $Re_{c}^{0.65}\;and\;Re_{c}^{0.71},$ respectively.

Study of Reduction of Mismatch Loss of a Thermoelectric Generator (열전발전 시스템의 부정합손실 저감방안 연구)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.3
    • /
    • pp.294-301
    • /
    • 2022
  • In this study, a multi-layer cascade (MLC) electrical array configuration method for thermoelectric generator consisting of plural number of thermoelectric modules (TEMs) was proposed to reduce mismatch loss caused by temperature maldistribution on the surfaces of the TEMs. To validate the effect of MLC on the mismatch loss reduction, a numerical model capable of reflecting multi-physics phenomena occuring in the TEMs was developed. MLC can be employed by placing a group of TEMs experiencing relatively low temperature differences in an electric layer with more electrical branches while locating a group of TEMs experiencing relatively high temperature differences in an electric layer with less electrical branches. The TEMs were classified using the temperature distribution obtained by the numerical model. A MLC with an optimal electrical branch ratio showed a 96.5% of electric power generation compared to an ideal case.

Numerical Study on Tip Clearance Effect on Performance Characteristics of a Centrifugal Compressor for a R134a Turbo-Chiller (R134a 터보냉동기용 원심압축기의 익단간극이 성능특성에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Park, Woon-Jean
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.6 s.27
    • /
    • pp.38-44
    • /
    • 2004
  • In this study, the overall performance and the effect of the tip leakage flow of the centrifugal compressor with a refrigerant HFC-l34a were numerically studied using CFX-TASCflow. To study the effect of the tip leakage flow, the numerical study of the overall performance of HFC-l34a centrifugal compressor with a cascade diffuser was preceded and compared with the experimental result. Six different tip clearances were used to consider the influence of the tip clearance on the performance. The tip leakage flow was illustrated for qualitative discussion. The results obtained in this study can be applied to the determination of the cold clearance.

Numerical Study on Tip Clearance Effect on Performance Characteristics of a Centrifugal Compressor for a R134a Turbo-Chiller (R134a 터보냉동기용 원심압축기의 익단간극이 성능특성에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Park, Woon-Jean
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.451-456
    • /
    • 2003
  • In this study, the overall performance and the effect of the tip leakage flow of the centrifugal compressor with the refrigerant HFC-l34a were numerically studied using CFX-TASCflow. To study the effect of a tip leakage flow, the numerical study of the overall performance of HFC-l34a centrifugal compressor with a cascade diffuser was preceded and compared with experimental result. Six different tip clearances were used to consider the influence of a tip clearance on performance. The tip leakage flow was illustrated for qualitative discussion. The results obtained in this study can be applied to the determination of the cold clearance.

  • PDF

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Effect of Incidence Angle on the Endwall Heat Transfer Within a Turbine Rotor Passage (입사각이 터빈 동익 끝벽 열전달에 미치는 영향)

  • Park Jin Jae;Lee Sang Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.696-702
    • /
    • 2005
  • The effect of incidence angle on the endwall heat (mass) transfer characteristics within a turbine rotor cascade passage has been investigated by employing the naphthalene sublimation technique. The experiments are carried out at the Reynolds number of $2.78{\times}10^5$ for two incidence angles of -5 and 5 dog. The result shows that the incidence angle has a considerable influence on the transport phenomena over the endwall. The positive incidence angle tends to promote development of the pressure-side leg of a leading-edge horseshoe vortex. The endwall thermal load is augmented by 7.5 percents at i = -5 deg but is reduced by 2.5 percents at i = 5 deg, in comparison with that at the design condition.

Visibility study in Seoul in Aug., 1993. (1993년 8월의 서울지역 시정 연구)

  • 이종훈;백남준;김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.291-298
    • /
    • 1995
  • An intensive field study was carried out during Aug. 1993 in Seoul to study the characteristics of summertime visibility and diurnal trend of ionic composition of ambient particles. A transmissometer, nephelometer with heated and unheated inlets, PM3 fine particle sampler, and cascade impactor were used to measure optical and particle properties of ambient air. During this study period, a weak smog episode has occurred. Light scattering by particles is the most dominant factor on total light extinction. The effect of light absorption by particles in Seoul is much higher than other major cities in U.S.A. throughout the summer and fall with relatively constant values. The effect of water on $b_{sp}$ was small during the period. The particle size distribution shows a typical bimodal one. Sulfate, ammonium, chloride, and nitrate are the major chemical species in fine fraction aerosols, about 30% of toral mass concentration. Concentraion of sulfate is higher during the daytime while those of nitrate and chloride are higher during the nighttime. Ammonium concentration is constant through the daytime.

  • PDF

Effect of Incidence Angle on Turbine Blade Heat Transfer Characteristics (II) - Blade Surface - (입사각 변화에 따른 터빈 블레이드에서의 열전달 특성 변화 (II) - 블레이드 표면 -)

  • Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.357-366
    • /
    • 2007
  • The present study investigated local heat/mass transfer characteristics on the surface of the rotating turbine blade with various incidence angles. The experiments are conducted in a low speed annular cascade with a single stage turbine. The blade has a flat tip with the mean tip clearance of 2.5% of the blade chord. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. At design condition, the inlet Reynolds number is $Re_c=1.5{\times}10^5$ which results in the blade rotation speed of 255.8 rpm. Also, the effect of off-design condition is examined with various incidence angles between $-15^{\circ}$ and $+7{\circ}$. The results indicated that the incidence angle has significant effects on the blade surface heat transfer. In mid-span region, the laminar separation region on the pressure side is reduced and the laminar flow region on the suction side shrinks with increasing incidence angle. Near the tip, the effect of tip leakage flow increases in span wise and axial directions as the incidence angle decreases because the tip leakage flow is formed near the suction side surface. However, the effect of tip leakage flow is reduced with positive incidence angle.

The Study on the Effect of External Information on Purchase Decision-Making Process in Online Shopping Mall Based Electronic Commerce (온라인 쇼핑몰 기반의 전자상거래에서 외적 정보가 구매 의사결정 과정에 미치는 영향에 대한 실증적 연구)

  • Kang, Sung-Min;Kim, Tae-Jun
    • Journal of Information Technology Applications and Management
    • /
    • v.14 no.4
    • /
    • pp.97-120
    • /
    • 2007
  • Development of information technology and Internet brought big changes in information society. Quantity of information increased rapidly and various types of information were presented through diverse channels. This change brought an impact in electronic commerce environment. A large number of products are transacted in online market. And various search functions and product information are presented for supporting customer's decision making. This study examined the effect of external information on purchase decision-making in electronic commerce environment. An experiment was conducted to see the customer product review, unit sales, etc. on purchase decision-making process in online shopping mall based electronic commerce. As a result of study, external information referring to number of purchasing, positive product review, and reliability of information has a positive effect on purchase-decision. The significance of the study can be found in that it defined 1) external information has an effect on decision-making, 2) positiveness and reliability of product information showed that they have an influence on customer, and 3) when self opinion and other person's opinion are different, one is not satisfied with decision making process. The results of the study can be of practical use in the design and implementation of online shopping mall in electronic commerce.

  • PDF