• 제목/요약/키워드: Cardiac valves

검색결과 137건 처리시간 0.02초

St. Jude Medical 기계판막의 임상적 연구 (Clinical Analysis of St. Jude Medical Prosthesis)

  • 최순호
    • Journal of Chest Surgery
    • /
    • 제24권2호
    • /
    • pp.171-181
    • /
    • 1991
  • Result of St. Jude Medical valve replacement are presented in 106 patients who underwent operation from January 1985 through July 1989. The patient were 52 males and 56 females. Total 136 of St. Jude Medical valves were implanted; 91 in mitral position, 45 in aortic position. The hospital mortality rate was 5.7%o[6 patients] and the late mortality rate was 2.0%[2 patients]. The causes of death were low cardiac output in 5, iatrogenic right ventricular rupture in 1, heart failure in 1, ventricular arrhythmia in l. And, the causes of valve related complication were anticoagulant related hemorrhage in 5 patients[0.03% /patient-year] and thromboembolism[0.01% /patient-year] in 2 patients. In conclusion, the performance of the St. Jude Medical valve compare most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

관상정맥동 천정결손증 3례 보고

  • 임창영;김요한;이인성;김광택;김형묵
    • Journal of Chest Surgery
    • /
    • 제20권1호
    • /
    • pp.218-222
    • /
    • 1987
  • Unroofed coronary sinus syndrome is an uncommon anomaly, Unroofed coronary sinus syndrome is caused by incomplete formation of the left atriovenous fold, and it usually is associated with Left SVC. If it is not diagnosed, a residual reversed or bidirectional shunt will result, and its complications will reduce life expectancy. We experienced 3 cases of unroofed coronary sinus syndrome which combines TOF with PLSVC, partial ECD, primum type ASD. In case of Unroofed coronary sinus syndrome which combines TIF with PLSVC, preoperative diagnosis was not made. In corrective operation for TOF of this case, pump weaning was failed due to hypoxia and cardiac arrest, and he expired at operation room. At autopsy of this case, complete unroofed coronary sinus was found. In the other 2 cases, partial unroofed coronary sinus syndrome was found in operation field and corrective operation was performed successfully. We report these 3 experiences with its review. ^u ++ Noninvasive Assessment of Pressure Gradients across Prosthetic Heart Valve by Doppler Ultrasound - A comparative study of the Duromedics Bileaflet Valves in mitral position and Normal Mitral Valves -with its review.

  • PDF

화학적 보정약이 정상견의 도플러 심초음파에 미치는 영향 (Effects of chemical restraint drugs on Doppler echocardiography in normal dogs)

  • 윤정희
    • 대한수의학회지
    • /
    • 제38권2호
    • /
    • pp.413-418
    • /
    • 1998
  • Intracardiac velocities were determined and the wave-forms described for 4 flow areas of the normal canine heart following administration of chemical restraint drugs including xylazine HCl, ketamine HCl, and thiopental sodium using pulsed wave Doppler echocardiography. The result was that xylazine HCl and thiopental sodium reduced intracardiac flow velocities through mitral, tricuspid, aortic and pulmonary valves. It is also thought that precautions are required before using these drugs. Patterns of wave-forms had no changes between control and treatment groups. Doppler echocardiography allows the clinician to determine flow velocities across the different valves and within the various chambers of the heart. It is shown that establishing normal values and those related to chemical restraint administrations and knowing what influences them should allow the clinician to non-invasively diagnose a variety of pathological cardiac conditions.

  • PDF

Duromedics 판막의 임상적 연구 (Clinical Study of Duromedics Bileaflet Valve)

  • 김상형;유홍석
    • Journal of Chest Surgery
    • /
    • 제23권4호
    • /
    • pp.667-675
    • /
    • 1990
  • From June, 15th, 1987 to June, 14th, 1989, 105 Duromedics bileaflet cardiac valve prostheses were implanted in 81 patients. Mitral valve replacement was done in 42 patients, 7 underwent aortic valve replacement, 28 underwent double valve replacement, & 4 patients underwent triple valve replacement. Concomitantly used valves were 13 cases; 11 cases were St. Jude Medical valves[M: SJM #29 X4, #27 X5, #25 X 1, T: SJM #33] & two cases were Carpentier Edwards bioprostheses[T: C - E #31X2]. The early mortality rate[within 30 days] was 3.7%[2 patients] & the late mortality rate was 7.4%[3 patients]. Follow-up was done on 72 surviving patients; mean follow-up period was 21.17$\pm$5.36 months. Anticoagulant-related hemorrhage was observed in two patients, possible prosthetic valvular endocarditis was observed in one patient and other specific valve-related complications were none. We concluded, therefore, that good clinical results & a low complication rate could be achieved with Duromedics bileaflet valve in short-term follow-up, & long-term follow-up was also necessary.

  • PDF

보조판막의 생채외 실험 연구 (In Vitro Analysis of Supplementary Valve)

  • 김상현;박영환;윤치순;김훈모;조범구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.329-332
    • /
    • 1997
  • To develop the supplementary heart valve which could reduce the complications of prosthetic heart valve, in vitro experiments were performed to analyze the movement of the supplementary valves. The autologous pericardium was attached to deficient portion of the porcine valve which was dissected completely and partially. The instantaneous motion of the leaflet was pictured by the 35mm camera and the pressure drop through the valve and cardiac output were measured in mock circulatory system. The durability of the valves were tested in severe hemodynamic conditions.

  • PDF

인공심장판막의 재치환술 (Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases-)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • 제29권2호
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF

St.Jude 기계판막을 이용한 인공심장판막 치환의 외과적 고찰 (Clinical Evaluation of St.Jude Medical Valve Replacement)

  • 진웅;나석주;조규도;김치경;조건현;왕영필;이선희;곽문섭;김세화;이홍균
    • Journal of Chest Surgery
    • /
    • 제27권4호
    • /
    • pp.272-280
    • /
    • 1994
  • Total 400 St.Jude Medical Bileaflet Valves were implanted in 336 pts from January 1983 to June 1993; 64 were aortic, 205 were mitral, 64 were double valve and 3 were tricuspid position. The follow up period extended from 6 months to 10 years[mean 24.3 months]. Male to female ratio was 1:1.7. There were total 27 deaths[cardiac related 20, cardiac non-related 7]. Overall mortality was 2.9%/pt-yr. There were 10 early deaths[3.0%] and 10 late cardiac related deaths [3.0%]. Prosthetic valve related complications occurred in 19 patients[5.7%] and among them, seven died; four died of thromboembolic events, two died of anticoagulants therapy related hemorrhagic complications and one died of bacterial endocarditis. NYHA class improved significantly especially in aortic valve replacement and double valve replacement. In AVR cases, the mean NYHA was 2.8 preoperatively and 1.3 postoperatively. And in DVR cases, 3.3 preoperatively and 2.2 postoperatively. The decision to employ a particular prosthesis was made according to the anticipated or known complications of the valve. The St.Jude Medical Valve retains all the hazards of other mechanical valves, most notably, thromboembolism. But the hemodynamic performance of St.Jude Medical Valve compared most favorably with other substitute valves in many reports. 0ur experience didn`t show any differences compared other authors in terms of valve related complication. So we concluded St. Jude Medical Valve can be primarily considered in the selection of artificial valve except in the patients when the usage of anticoagulant therapy is contraindicated.

  • PDF

Thymosin Beta4 Regulates Cardiac Valve Formation Via Endothelial-Mesenchymal Transformation in Zebrafish Embryos

  • Shin, Sun-Hye;Lee, Sangkyu;Bae, Jong-Sup;Jee, Jun-Goo;Cha, Hee-Jae;Lee, You Mie
    • Molecules and Cells
    • /
    • 제37권4호
    • /
    • pp.330-336
    • /
    • 2014
  • Thymosin beta4 (TB4) has multiple functions in cellular response in processes as diverse as embryonic organ development and the pathogeneses of disease, especially those associated with cardiac coronary vessels. However, the specific roles played by TB4 during heart valve development in vertebrates are largely unknown. Here, we identified a novel function of TB4 in endothelial-mesenchymal transformation (EMT) in cardiac valve endocardial cushions in zebrafish. The expressions of thymosin family members in developing zebrafish embryos were determined by whole mount in situ hybridization. Of the thymosin family members only zTB4 was expressed in the developing heart region. Cardiac valve development at 48 h post fertilization was defected in zebrafish TB4 (zTB4) morpholino-injected embryos (morphants). In zTB4 morphants, abnormal linear heart tube development was observed. The expressions of bone morphogenetic protein (BMP) 4, notch1b, and hyaluronic acid synthase (HAS) 2 genes were also markedly reduced in atrio-ventricular canal (AVC). Endocardial cells in the AVC region were stained with anti-Zn5 antibody reactive against Dm-grasp (an EMT marker) to observe EMT in developing cardiac valves in zTB4 morphants. EMT marker expression in valve endothelial cells was confirmed after transfection with TB4 siRNA in the presence of transforming growth factor ${\beta}$ ($TGF{\beta}$) by RT-PCR and immunofluorescent assay. Zn5-positive endocardial AVC cells were not observed in zTB4 morphants, and knockdown of TB4 suppressed TGF-${\beta}$-induced EMT in ovine valve endothelial cells. Taken together, our results demonstrate that TB4 plays a pivotal role in cardiac valve formation by increasing EMT.

판막질환을 동반한 관상정맥동 천정결손 증후군 - 수술 치험 1례 - (Unroofed Coronary Sinus Syndrome with Valvular Disease - Report of A Case -)

  • 박성달
    • Journal of Chest Surgery
    • /
    • 제23권1호
    • /
    • pp.162-168
    • /
    • 1990
  • Unroofed coronary sinus syndrome is an uncommon anomaly which is caused by incomplete formation of the left atriovenous fold and it is usually associated with persistent left superior vena cava. It may be diagnosed by cardiac catheterization and cineangiography but, if it is not diagnosed, it can bring out significant complications due to right to left shunt, such as brain abscess, cerebral embolism, transient ischemic attack, arterial desaturation and there will reduced patient`s life expectancy. Therefore corrective operation was needed. A case of unroofed coronary sinus syndrome which combines with valvular heart disease was experienced at the department of thoracic & cardiovascular surgery of Kosin medical college. The patient was 49 years old female and she complained dyspnea on exertion for 2 yrs. Cardiac catheterization with cineangiography and both superior venacavogram were performed for diagnosis and she was diagnosed as unroofed coronary sinus syndrome combined with mitral and tricuspid regurgitation. Surgical correction was accomplished by reroofing of coronary sinus with pericardial patch, closure of atrial septal defect and annuloplasty of both atrioventricular valves. Postoperative results were satisfactory and course of recovery was uneventful. We report a case of unroofed coronary sinus syndrome with review.

  • PDF

심장질환의 외과적 치료 -1640 수술예 보고- (Cardiac Surgery : A report of 1640 cases)

  • 이영균
    • Journal of Chest Surgery
    • /
    • 제13권2호
    • /
    • pp.92-99
    • /
    • 1980
  • From 1958 up to the end of April 1980, during the period of 12 years 1640 cardiac surgery cases including 1069 open heart surgery and 304 valve replacement cases, were operated in this Department. There were 1070 congenital anomaly and 570 acquired disease cases. In 1070 congenital anomaly cases 673 acyanotic and 397 cyanotic anomaly patients were noted. In acquired diseases 94 pericardial and 456 valvular cases were found. Among 456 valve cases 189 mitral stenosis, 133 mitral insufficiency, 30 aortic valve lesion, 97 double valve, and 7 triple valve lesion patients were noted. Among 304 valve replacement cases 209 mitral, 34 aortic, 5 tricuspid, 34 aortic with mitral, 20 mitral with tricuspid, and 2 triple valves were replaced. Annual increase `of open heart surgery cases and decrease of operative deaths were remarkable in recent years. In recent years Shiley** oxygenator in pump-oxygenator set up and Ionescu** bovine pericardial xenograft bioprosthesis were used for valve replacement mainly.

  • PDF