• Title/Summary/Keyword: Carbon Deposit

Search Result 129, Processing Time 0.035 seconds

MWCNT, silver nanoparticles, CuBTC를 사용한 염소 이온 센서 합성

  • Gwak, Byeong-Gwan;Park, Su-Bin;Yu, Bong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.101-101
    • /
    • 2018
  • Quantitative measurement of chloride ion concentration has an important role in various fields of electrochemistry, medical science, biology, metallurgy, architecture, etc. Among them, its importance of architecture is ever-growing due to unexpected degradations of building structure. These situations are caused by corrosion of reinforced concrete (RC) structure of buildings. And chloride ions are the most powerful factors of RC structure corrosion. Therefore, precise inspection of chloride ion concentration must be required to increase the accuracy of durability monitoring. Multi-walled Carbon nanotubes (MWCNTs) have high chemical resistivity, large surface area and superior electrical property. Thus, it is suitable for the channels of electrical signals made by the sensor. Silver nanoparticles were added to giving the sensing property. CuBTC, one of the metal organic frameworks (MOFs), was employed as a material to improve the sensing property because of its hydrophilicity and high surface area to volume ratio. In this study, sensing element was synthesized by various chemical reaction procedures. At first, MWCNTs were functionalized with a mixture of sulfuric acid and nitric acid because of enhancement of solubility in solution and surface activation. And functionalized MWCNTs, silver nanoparticles, and CuBTC were synthesized on PTFE membrane, one by one. Electroless deposition process was performed to deposit the silver nanoparticles. CuBTC was produced by room temperature synthesis. Surface morphology and composition analysis were characterized by scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDS), respectively. X-ray photoelectron spectroscopy (XPS) was also performed to confirm the existence of sensing materials. The electrical properties of sensor were measured by semiconductor analyzer. The chloride ion sensing characteristics were confirmed with the variation of the resistance at 1 V.

  • PDF

The Specific Case Analysis of Biomineralization Induced by Sulfate Reducing Bacteria

  • Liu, Hongwei;Qin, Shuang;Fu, Chaoyang;Xiao, Fei;Wang, Deli;Han, Xia;Wang, Tianli;Liu, Hongfang
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.285-293
    • /
    • 2017
  • The effects of sulfate reducing bacteria (SRB) on the corrosion and scaling of the Q235 carbon steel has been investigated in the simulated sewage water and oil field gathering pipelines production water, using scanning electron microscopy (SEM), energy dispersive x-ray spectrometry (EDS), and three-dimensional stereoscopic microscope. Results indicated that the concentration of SRB reached the maximum value on the ninth day in simulated sewage water with a large amount of scaling on the surface of specimen. In oil field gathering pipelines, a large amount of scaling and mineralization of mineral salts and thick deposition of extracellular polymeric substance (EPS) layers were also observed on the surface of specimen. The thickness of biofilm was about $245{\mu}m$ within 30 days. After adding microbicides, the thickness of corrosion products film was only up to $48-106{\mu}m$ within 30 days, suggesting that SRB could induce biomineralization. Under-deposit corrosion morphology was uniform in the absence of microbicides while local corrosion was observed in the presence of microbicides.

Removal of Contaminants Deposited on Surfaces of Matrices by Using Low-Temperature Argon Plasma Treatment (저온 아르곤 플라즈마처리를 이용한 모재 표면의 오염물 제거)

  • Seo, Eun-Deock
    • Journal of Conservation Science
    • /
    • v.30 no.3
    • /
    • pp.299-306
    • /
    • 2014
  • The possibility of a low-temperature argon plasma treatment as a mean of restoration technology for contaminated invaluable archive materials and artefacts, and evidencing documents was investigated along with an oxygen plasma treatment for comparison. For this purpose, the degree of color changes, ${\Delta}E^*ab$, and surface morphological changes due to plasma treatments as an evaluation of removal performance of artificial contaminants such as brilliant green dye and carbon deposit on cellulose acetate and plain paper as matrices, respectively, were measured and analyzed using a spectrophotometer and a field emission scanning electron microscope. Compared to the argon plasma treatment with sputtering characteristic, that of the oxygen plasma with characteristic of an oxidation reaction has shown superior results in removing the contaminants; the oxygen plasma has proven to damage the matrices significantly due to its oxidative characteristic, and post-plasma reactions has anticipated to be also detrimental to the surfaces, whereas, the problems caused by the counterpart has resulted in being negligible and rather has thought to be an appropriate mean for delicate restoration and/or removal operations of contaminants.

Thermodynamic Prediction of SiC Deposition in C3H8-SiCl4-H2 System (C3H8-SiCl4-H2 시스템에서의 탄화 실리콘 증착에 대한 열역학적인 해석)

  • Kim, Jun-Woo;Jeong, Seong-Min;Kim, Hyung-Tae;Kim, Kyung-Ja;Lee, Jong-Heun;Choi, Kyoon
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.3
    • /
    • pp.236-240
    • /
    • 2011
  • In order to deposit a homogeneous and uniform ${\beta}$-SiC films by chemical vapor deposition, we demonstrated the phase stability of ${\beta}$-SiC over graphite and silicon via computational thermodynamic calculation considering pressure, temperature and gas composition as variables. The ${\beta}$-SiC predominant region over other solid phases like carbon and silicon was changed gradually and consistently with temperature and pressure. Practically these maps provide necessary conditions for homogeneous ${\beta}$-SiC deposition of single phase. With the thermodynamic analyses, the CVD apparatus for uniform coating was modeled and simulated with computational fluid dynamics to obtain temperature and flow distribution in the CVD chamber. It gave an inspiration for the uniform temperature distribution and low local flow velocity over the deposition chamber. These calculation and model simulation could provide milestones for improving the thickness uniformity and phase homogeneity.

Growth and characterization of molecular beam epitaxy grown GaN thin films using single source precursor with ammonia

  • Chandrasekar, P.V.;Lim, Hyun-Chul;Chang, Dong-Mi;Ahn, Se-Yong;Kim, Chang-Gyoun;Kim, Do-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.174-174
    • /
    • 2010
  • Gallium Nitride(GaN) attracts great attention due to their wide band gap energy (3.4eV), high thermal stability to the solid state lighting devices like LED, Laser diode, UV photo detector, spintronic devices, solar cells, sensors etc. Recently, researchers are interested in synthesis of polycrystalline and amorphous GaN which has also attracted towards optoelectronic device applications significantly. One of the alternatives to deposit GaN at low temperature is to use Single Source Molecular Percursor (SSP) which provides preformed Ga-N bonding. Moreover, our group succeeds in hybridization of SSP synthesized GaN with Single wall carbon nanotube which could be applicable in field emitting devices, hybrid LEDs and sensors. In this work, the GaN thin films were deposited on c-axis oriented sapphire substrate by MBE (Molecular Beam Epitaxy) using novel single source precursor of dimethyl gallium azido-tert-butylamine($Me_2Ga(N_3)NH_2C(CH_3)_3$) with additional source of ammonia. The surface morphology, structural and optical properties of GaN thin films were analyzed for the deposition in the temperature range of $600^{\circ}C$ to $750^{\circ}C$. Electrical properties of deposited thin films were carried out by four point probe technique and home made Hall effect measurement. The effect of ammonia on the crystallinity, microstructure and optical properties of as-deposited thin films are discussed briefly. The crystalline quality of GaN thin film was improved with substrate temperature as indicated by XRD rocking curve measurement. Photoluminescence measurement shows broad emission around 350nm-650nm which could be related to impurities or defects.

  • PDF

Study for Failure Examples of Solenoid Valve, Relay and Idle Speed Control Actuator in Liquid Petroleum Gas vehicle Engines (LPG 자동차 엔진의 솔레노이드밸브, 릴레이, 공회전조절장치의 고장사례 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon;Cho, Seung-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.47-52
    • /
    • 2011
  • The purpose of this paper analyzes and studies to seek the failure examples of electronic control actuators for engine in liquified petroleum gas vehicle. The first, it was verified phenomenon for intial starting damage and no-acceleration of engine because of occasionally fuel feeding interception by clogged of emergency cutting solenoid valve filter. The second, the contact resistance produced in the connecting part of engine control relay because of no fully surface contacting by processes and assembly badness. It was displayed phenomenon of re-starting badness. The actuator that idle speed control system was sticked inside because of intake-air decreasing by carbon deposit. As a result, it was verified the phenomenon of disharmony that repeated up and down the engine revolution.

A Vertical and Spatial Study of Sediment Deposits Developing Along Yeongsan River (영산강유력(榮山江流域) 퇴적층(堆積層)의 수직적.공간적(垂直的.空間的) 발달(發達) 연구(硏究))

  • Eun, Ge-Yeo-Na;You, Hoan-Su;Kim, Dong-Ju
    • Journal of the Korean earth science society
    • /
    • v.18 no.6
    • /
    • pp.540-552
    • /
    • 1997
  • For the scientific and systematic study of sediment deposits along Yeongsan river, total 13 core samples were taken from Yeongsan river. The thickness of sediment deposits is 22.0m at YS 1, 20.0m YS 2, 18.5m YS 3, 12.0m YS 4, 3.0m YS 5, 5.5m YS 7, 3.0m YS 8, 5.9m YS 9, 5.0m YS 10 on main stream of Yeongsan river. The thickness of deposit is increasing from upstream to downstream. The composition of sediments dominates sandy gravel on the upstream and the lower part on the downstream, and mud deposits of $11m{\sim}16m$ thick on the upper part of on the downstream(YS 1, YS 2, and YS 3). Contents of organic carbon and calcium carbonates occur being contrary to each other toward upstream. The content of organic carbon increases upstream, that of calcium carbonates decreases. According to size analysis of sediment, the content of gravel increases and mud decreases from downstream to upstream. Sediment deposits can be divided into two types whether gravel is or not. But this boundary is clear in the downstream(YS 1$\sim$YS 4) but is vague in the upstream. The result of this study could be provided engineering, environment, and architecture with geological background as the essential basis.

  • PDF

The Relationship Between Intestinal Iron Absorption and Hepatic Parenchymal Cell Damage (간실질세포(肝實質細胞)의 손상(損傷)이 철흡수(鐵吸收)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Mok-Hyun;Hahn, Shim-Suck
    • The Korean Journal of Nuclear Medicine
    • /
    • v.5 no.2
    • /
    • pp.19-40
    • /
    • 1971
  • Since the iron balance is maintained by regulated intestinal absorption rather than regulated excretion, there have been many reports concerning the factors which may influence the intestinal iron absorption. As the liver is the largest iron storage organ of the body, any hepatocellular damage may result in disturbances in iron metabolism, e,g., frequent co-existence of hemochromatosis and liver cirrhosis, or elevated serum iron level and increased iron absorption rate in patients with infectious hepatitis or cirrhosis. In one effort to demonstrate the influence of hepatocellular damage on intestinal iron absortion, the iron absorption rate was measured in the rabbits whose livers were injured by a single subcutaneous injection of carbon tetrachloride (doses ranging from 0.15 to 0.5cc per kg of body weight) or by a single irradiation of 2,000 to 16,000 rads with $^{60}Co$ on the liver locally. A single oral dose of $1{\mu}Ci\;of\;^{59}Fe$-citrate with 0.5mg of ferrous citrate was fed in the fasting state, 24 hours after hepatic damage had been induced, without any reducing or chelating agents, and stool was collected for one week thereafter. Serum iron levels, together with conventional liver function tests, were measured at 24, 48, 72, 120 and 168 hours after liver damage had been induced. All animals were sacrificed upon the completing of the one week's test period and tissue specimens were prepared for H-E and Gomori's iron stain. Following are the results. 1. Normal iron absorption rate of the rabbit was $41.72{\pm}3.61%$ when 0.5mg of iron was given in the fasting state, as measured by subtracting the amount recovered in stool collected for 7 days from the amount given. The test period of 7 days is adequate, for only 1% of the iron given was excreted thereafter. 2. The intestinal iron absorption rate and serum iron level were significantly increased when the animal was poisoned by a single subcutaneous injection of 0.15cc. per kg. of body weight of carbon tetrachloride or more, or the liver was irradiated with a single dose of 12,000 rads or more. The results of liver function tests which were done simultaneously remained within normal limit except SGOT and SGPT which were somewhat increased. 3. In each case, there has been good correlation between the extent of liver cell damage and degree of increased iron absorption rate or serum iron level. 4. The method of liver damage appeared to make no obvious difference in the pattern of iron deposit in liver. This may be partly due to the fact that tissue specimens were obtained too late, for by this time the elevated serum iron level had returned within normal range and the pathological changes were almost healed. 5. The possible factors and relationship between intestinal iron absorption and hepatic parenchymal cell damage has been discussed.

  • PDF

Upstream Risks in Domestic Battery Raw Material Supply Chain and Countermeasures in the Mineral Resource Exploration Sector in Korea (국내 배터리원료광종 공급망 업스트림 리스크와 광물자원탐사부문에서의 대응방안)

  • Oh, Il-Hwan;Heo, Chul-Ho;Kim, Seong-Yong
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.399-406
    • /
    • 2022
  • In line with the megatrend of 2050 carbon neutrality, the amount of critical minerals used in clean-energy technology is expected to increase fourfold and sixfold, respectively, according to the Paris Agreement-based scenario as well as the 2050 carbon-neutrality scenario. And, in the case of Korea, in terms of the battery supply chain used for secondary batteries, the midstream that manufactures battery materials and battery cell packs shows strength, but the upstream that provides and processes raw materials is experiencing difficulties. The Korea Institute of Geoscience and Mineral Resources has established a strategy to secure lithium, nickel, and cobalt and is conducting surveys to respond to the upstream risk of these types of battery raw materials. In the case of lithium, exploration has been carried out in Uljin, Gyeongsangbuk-do since 2020, and by the end of 2021, the survey area was selected for precision exploration by synthesizing all exploration data and building a 3D model. Potential resources will be assessed in 2022. In the case of nickel, the prospective site will be selected by the end of 2022 through a preliminary survey targeting 10 nickel sulfide deposits that have been prospected in the past. In the case of cobalt, Boguk cobalt is known only in South Korea, but there is only a record that cobalt was produced as a minor constituent of hydrothermal deposit. According to the literature, a cobalt ore body was found in the contact area between serpentinite and granite, and a protocol for cobalt exploration in Korea will be established.

A Study on Public Nuisance in Kwangju City (Survey on Air Pollution and Noise Level) (공해(公害)에 관(關)한 조사연구(調査硏究) -광주시(光州市)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 조사연구(調査硏究)-)

  • Chung, Yo-Han;Kim, Kil-Wng;Moon, Jae-Kyu;Jhoo, Heung-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 1972
  • During the period from June 1st 1971 to November 30 th 1971, studies on air pollution were made in Kwangju city. The city was divided into 6 areas; the downtown area, the semi-downtown area, the heavy traffic area, the commercial area, the residential area, the park area, 13 surveying sites were selected each representing the characteristics of the area. The Measurement methods which were used are described below. Sulfur oxides were measured by $PbO_2$ cylinder method, sulfur dioxides ($SO_2$) and carbon monoxide (CO) by the MSA & Kitakwa detector, dustfall by the Deposit gauge method, and the noise levels by the Kanomax soundlevel meter. The results obtained are as follows: 1. The mean value of sulfur oxides in Kwangju city was $1.16mg\;SO_3/day/100cm^2\;PbO_2$, ranging from $0.45mg\;SO_3/day/100cm^2\;PbO_2$ to $3.10mg\;SO_3/day/100cm^2\;PbO_2$. 2. The mean values of sulfur oxides according to its specific area in the city were $1.45mg\;SO_3/day/100cm^2\;PbO_2$ in heavy traffic area, 1.36 in downtown area, 1.23 in semi-downtown area, 1.11 in commercial area, 0.96 in residential area, and 1.07 in park area, respectively. 3. The average concentration of sulfur dioxide was 0.063 ppm from 2 to 5 P.M in Kwangju city. 4. The average concentrations of sulfur dioxides according to its specific area, from 2 to 5 P.M, in the city were 0.084 ppm in heavy traffic area & downtown area, 0.067 in commercial area, 0.053 in semi-downtown area, 0.052 in residential area, and 0.036 in park area. 5. The average concentration of carbon monoxide was 22.3 ppm from 2 to 5 P.M, in Kwangju city. 6. The average concentrations of carbon monoxide according to its specific area, from 2 to 5 P.M, in the city were 27.0 ppm in downtown area, 26.3 in semi-downtown area, 23.0 in heavy traffic area, 21.7 in commercial area, 20.0 in residential arera, and 17.6 in park area. 7. The mean value of dusifall in Kwangju city was $29.28ton/km^2/month$, ranging from $9.85ton/km^2/month$ to $66.34ton/km^2/month$. 8. The mean values of dustfall according to its specific area in the city were $50.37ton/km^2/month$ in semi-downtown area, 42.76 in heavy traffic area, 34.67 in downtown area, 17.77 in commercial area, 14.40 in park area, and 14.76 in residential area. 9. The mean values of the soluble dust in Kwangju city was $10.23ton/Km^2/month$ and that of the insoluble dust was $19.05ton/Km^2/month$. 10. The mean value of noise level in Kwangju city was 62 phon, ranging from 37 phon to 88 phon. 11. The mean values of noise level according to its specific area in the city were 76 phon in heavy traffic area, 67 in semi-downtown area, 64 in downtown area, 59 in commercial area, 52 in part area, and 50 in residential area.

  • PDF