• 제목/요약/키워드: Capillary pore

검색결과 137건 처리시간 0.023초

Suitable Use of Capillary Number for Analysis of NAPL Removal from Porous Media

  • Jeong, Seung-Woo,
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.25-28
    • /
    • 2004
  • The capillary number is used to represent the mobilization potential of organic phase trapped within porous media. The capillary number has been defined by three different forms, according to types of flow velocity and viscosity used in the definition of capillary number. This study evaluated the suitability of the capillary number definitions for representing TCE mobilization by constructing capillary number-TCE saturation relationships. The results implied that the capillary number should be correctly employed, according to interest of scale and fluid flow behavior. This study suggests that the pore-scale capillary number may be used only for investigating the organic-phase mobilization at the pore scale because it is defined by the pore-velocity and the dynamic viscosity. The Newtonian-fluid capillary number using Darcy velocity and the dynamic viscosity may be suitable to quantify flood systems representing Newtonian fluid behavior. For viscous-force modified flood systems such as surfactant-foam floods, the apparent capillary number definition employing macroscopic properties (permeability and potential gradient) may be used to appropriately represent the desaturation of organic-phases from porous media.

  • PDF

Realistic pore structure of Portland cement paste: experimental study and numerical simulation

  • Ma, Hongyan;Li, Zongjin
    • Computers and Concrete
    • /
    • 제11권4호
    • /
    • pp.317-336
    • /
    • 2013
  • In this study, the pore structure of Portland cement paste is experimentally characterized by MIP (mercury intrusion porosimetry) and nitrogen adsorption, and simulated by a newly developed status-oriented computer model. Cement pastes with w/c=0.3, 0.4 and 0.5 at ages from 1 day to 120 days are comprehensively investigated. It is found that MIP cannot generate valid pore size distribution curves for cement paste. Nevertheless, nitrogen adsorption can give much more realistic pore size distribution curves of small capillary pores, and these curves follow the same distribution mode. While, large capillary pores can be effectively characterized by the newly developed computer model, and the validity of this model has been proved by BSE imaging plus image analysis. Based on the experimental findings and numerical simulation, a hypothesis is proposed to explain the formation mechanism of the capillary pore system, and the realistic representation of the pore structure of hydrated cement paste is established.

Comparison of the Mercury Intrusion Porosimerty, Capillary Flow Porometry and Gas Permeability of Eleven Species of Korean Wood

  • Jang, Eun-Suk;Kang, Chun-Won;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권6호
    • /
    • pp.681-691
    • /
    • 2018
  • The typical methods of mercury intrusion porosimetry (MIP) and capillary flow porometry (CFP) were used to evaluate the pore size of cross-section of wood and the effect of the pore structure on the permeability of wood was analyzed in this study. The results of this study were as followings: The pore size of wood measured by CFP was larger than that measured by MIP except for Lime tree, Korean red pine and Paulownia. Among the three pore types of porous materials defined by IUPAC (through pores, blind pores, and closed pores), only through pores are related to permit fluid flow. MIP measures the pore size of both through pores and blind pores, while CFP measures the pore size of only constricted through pores. Therefore, pore size measured by MIP was not related to gas permeability, however pore size measured by CFP had a proportional relationship with gas permeability.

고로슬래그 미분말 혼입 시멘트 페이스트의 프랙탈 특성에 관한 기초적 분석 (Basic Analysis on Fractal Characteristics of Cement Paste Incorporating Ground Granulated Blast Furnace Slag)

  • 김지영;최영철;최성철
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.101-107
    • /
    • 2017
  • 본 연구는 시멘트계 재료의 프랙탈 특성에 관한 기초적 연구로써, 고로슬래그 미분말 혼입 시멘트 페이스트의 공극 구조를 수은압입법을 이용하여 측정하였고, 측정된 결과를 프랙탈 모델에 적용하여 그 특성을 분석하였다. 분석 결과, 고로슬래그미분말 혼입 시멘트 페이스트의 공극 구조는 그 범위가 나노미터부터 밀리미터 단위까지 다양하게 분포하는 불규칙한 조직이기 때문에, 전체 영역에 대한 프랙탈 차원을 산정했을 때 각 공극 영역의 특성을 반영할 수 없다. 따라서 프랙탈 차원 산정 시 공극 영역을 나누어서 분석하였다. Zhang and Li (1995) model을 적용했을 때, 시멘트와 GGBFS의 수화반응 결과 생성된 C-S-H 내의 gel pores 및 small capillary pores에 해당하는 micro 영역과 large capillary pores에 해당하는 macro 영역에서 각각 프랙탈 특성이 나타나는 결과를 보였다. 또한 macro 영역보다 micro 영역의 공극 표면이 더 불규칙한 형상을 나타내었다. Ji et al. (1997) model을 적용할 경우, micro 영역이 C-S-H 내의 gel pores에 해당하는 micro I과 small capillary pores에 해당하는 micro II로 구분되었으며, 각각의 프랙탈 특성이 산정되었다. 또한 Zhang and Li (1995) model을 결과와 유사하게, macro, micro II, micro I의 순서대로 공극 크기가 작아질수록 VFD 결과 값이 감소하였으며, 이는 곧 공극의 복잡성이 증가함을 나타낸다.

Sintered Metal Wicks Development for the High Performance Loop Heat Pipe(LHP) Systems

  • 최지훈;성병호;유정현;서민환;김철주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2136-2141
    • /
    • 2007
  • The Loop Heat Pipe(LHP) system uses capillary forces so as to pump the working fluid from heat acquisition to heat rejecting systems. The performance of the LHP systems depends mainly upon the operating performance of the wick structure. The capillary pressure increases with decreasing the pore size of the wick structure. By the way, the wick structure's permeability decreases with decreasing the pore size and the porosity. To obtain an ideal wick, the wick structure should possess several characteristics such as the small pore size, high porosity and chemical compatibility with working fluid. Sintered metal wicks have been mainly used as the capillary wick structure mounted in LHP because of the fact that the sintered metal wick has some advantages like convenient selection of wick material, smaller pore size and so on as well as high reliability. In this study, sintered metal wicks were developed to meet required several parameters to design the high performance LHP systems for obtaining even more effective cooling technologies.

  • PDF

A Novel Technoque for Characterization of Membranes

  • Webber, Ronald;Jena, Akshaya;Gupta, Krishna
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2001년도 제14회 심포지엄 : 제2회 분리막 표준화(The 2nd Standardization of Membranes)
    • /
    • pp.39-50
    • /
    • 2001
  • The performance of membranes is governed their pore struture. Pore structures of porous materials can be determined by a number of techniques. However, The novel technique, capillary folw porometry has a number of advantages. In this technique, the sample is brought in contact with a liquid that fills the pores in the membrane spontaneously. Gas under pressure is used to force the liquid from the pores and increase gas flow. Gas flow rate measured as a function of gas pressure in wet and dry samples yield data on the largest pore size, the mean flow pore size, flow distribution and permeability. Pore characteristics of a number of membranes were measured using this technique. This technique did not require the use of any toxic material and the pressure employed was low. Capillary flow porometry is a suitable technique for measurement of the pore structure of many membranes.

  • PDF

Modeling of sulfate ionic diffusion in porous cement based composites: effect of capillary size change

  • Gospodinov, Peter N.
    • Computers and Concrete
    • /
    • 제4권2호
    • /
    • pp.157-166
    • /
    • 2007
  • The paper considers a theoretical model to study sulfate ion diffusion in saturated porous media - cement based mineral composites, accounting for simultaneous effects, such as filling micro-capillaries (pores) with ions and chemical products and liquid push out of them. Pore volume change and its effect on the distribution of ion concentration within the specimen are investigated. Relations for the distribution of the capillary relative radius and volume within the composite under consideration are found. The numerical algorithm used is further completed to consider capillary size change and the effects accompanying sulfate ion diffusion. Ion distribution within the cross section and volume of specimens fabricated from mineral composites is numerically studied, accounting for the change of material capillary size and volume. Characteristic cases of 2D and 3D diffusion are analyzed. The results found can be used to both assess the sulfate corrosion in saturated systems and predict changes occurring in the pore structure of the composite as a result of sulfate ion diffusion.

토양속의 LAPLs 제거기슬에서의 Pore와 입도분포의 응용에 관한 연구 (APPLICATIONS OF PORE AND GRAIN-SIZE DISTRIBUTIONIN RECOVERY OF LNAPLS IN SOILS)

  • Lee, Kwang-Y.
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 폐기물 매립지의 공학적 특성과 개량기술
    • /
    • pp.19-32
    • /
    • 1992
  • Objectives of this study are : 1) to utilize capillary theory and obtain pore-size distribution profiles from moisture-suction relationships using Laplace theory. 2) to investigate the behavior of Light Non-Aqueous Phase Liquids(LNAPLs) in the subsurface environment and to develop several predictive relationships which can be used to assess the effectiveness of various LNAPLs remediation technologies. The relationship to predict pore-size distribution function expressed in differencial equation is found by using capillary theory. Also, experiments are conducted to : the various LNAPLs subjected to vadose zone drainage, groundwater table drainage, waterflooding with surfactants. The experiments are performed with #2 heating oil, jet fuel. and kerosene. Several relationships have been derived describing the effect of various properties and process parameters on the LNAPL residual saturation.

  • PDF

Pore Characterization in Cross Section of Yellow Poplar (Liriodendron tulipifera) Wood

  • Jang, Eun-Suk;Kang, Chun-Won;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권1호
    • /
    • pp.8-20
    • /
    • 2019
  • This study was conducted to analyze the pore structure of Yellow poplar. Cross-sectional surfaces of heartwood and sapwood of Yellow poplar (Liriodendron tulipifera) were observed by SEM, and the true density of the heartwood, intermediate wood and sapwood were measured by gas pycnometery, while gas permeability and pore size of heartwood, intermediate wood and sapwood were measured by capillary flow porometery. The pores were classified as through pore, blind pore and closed pore. It was determined that the permeability was increased due to the content and size of through pore being increased although the total porosity of specimen showed slight difference from pith to bark. The content of through pore porosity was 33.754 % of heartwood and 47.810 % of sapwood, showed an increasing trend from pith to bark, however, those for the blind pore porosity and closed pore porosity were 27.890 % and 19.492 % for heartwood and 19.447 % and 4.660 % for sapwood, showed a decreasing trend from pith to bark. The max pore size of specimens was increased by about 5 times from $5.927{\mu}m$ to $31.334{\mu}m$, and mean flow pore size was increased by about 315 times from $0.397{\mu}m$ to $12.437{\mu}m$ from pith to bark.

미세 다공막을 통한 기체 투과기구 (Mechanisms of Gas Permeation through Microporous Membranes - A Review)

  • 황선탁
    • 멤브레인
    • /
    • 제7권1호
    • /
    • pp.1-10
    • /
    • 1997
  • A review is presented for various gas transport mechanisms through microporous membranes of both polymeric and inorganic materials. Different transport modes manifest depending on the pore size and the flow regime, which is a function of pressure, temperature, and the interaction between gas molecules and the pore walls. For microporous membranes whose pores are small and the internal surface area huge, the surface diffusion becomes a significant factor. If the pores become even smaller, then the transport mechanism will be more of an activated diffusion type. When conditions are right capillary condensation will take place to create an enormous capillary pressure gradient, which will greatly enhance the permeation flux. At the same time the capillary condensate of the heavier component may block the membrane pores denying the passage of the lighter gas molecules. All of these phenomena will influence the separation of mixtures.

  • PDF