• Title/Summary/Keyword: Capillary method

Search Result 503, Processing Time 0.034 seconds

Decrease in the Thickness of Capillary Fringe Induced by Surface Active Chemicals in the Groundwater (계면활성물질의 지하수적용에 의한 모관수대 두께의 감소)

  • Kim, Heonki;Shin, Seungyup;Yang, Haewon
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.52-58
    • /
    • 2012
  • Capillary fringe divides the groundwater and the vadose zone controlling the diffusive mass transfer of contaminants and gases. The thickness of capillary fringe is of great importance for the rate of contaminant mass transfer across the capillary fringe. Application of surface active chemicals including surfactants and alcohol-based products into the subsurface environment changes the surface tension of the aqueous phase, which in turn, affects the thickness of the capillary fringe. In this study, a bench-scale model was used to assess the quantitative relationship between the surface tension and the thickness of the capillary fringe. An anionic surfactant (Sodium dodecylbenzene sulfonate, SDBS) and an aqueous solution of ethanol were used to control the surface tension of the groundwater. It was found that the thickness of the capillary fringe is directly proportional to the surface tension. The air entry pressures measured by the Tempe Pressure Cell at different surface tensions using SDBS (200 mg/L) and ethanol (20%, v/v) solutions were in good agreement with the thicknesses of the capillary fringe measured by the model. A simple method to correct the conventional Brooks-Corey model for estimating the air entry pressure was also presented.

Selection of Capillary Tubes for HCFC-22 Alternative Fluids (HCFC-22 대체냉매의 모세관 선정)

  • Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.435-449
    • /
    • 1995
  • In this paper, pressure drop through a capillary tube is modeled to determine the length of a capillary tube for a given set of conditions. HCFC-22 and its alternatives, HFC-134a, R407B, and R410A are used as working fluids. The conditions on which the model is tested are as follows : condensing temperature; 40.0, 45.0, 50.0, $55.0^{\circ}C$, degree of subcooling;0.0, 2.5, $5.0^{\circ}C$, capillary tube exit condition;choked flow, capillary tube diameter;1.2~2.4mm, mass flow rate;5.0~50.0g/sec. The results justify the use of Stoecker's model which yields the results very close to the values in ASHRAE handbook. While McAdams' method yields much better results than Duckler's in calculating the viscosity of the fluid in 2-phase, the friction factor suggested by Stoecker seems to be the best for capillary tubes of large diameter used in residential air conditioners. For each refrigerant, 372 data with various variables are calculated by the model. The results show that capillary tube length varies very uniformly with changes in condensing temperature and degree of subcooling. Based on this fact, regression analysis is performed to determine the dependence of mass flow rate on the length and diameter of a capillary tube, condensing temperature, and degree of subcooling. Thus determined correlation yields a mean deviation of 2.36% for 1,488 data, showing an excellent agreement.

  • PDF

Enantiomeric Profiling Analysis of NSAIDs by Capillary Electrophoresis Using TM $\beta$-Cyclodextrin as the Chiral Selector

  • Kim, Ji-Young;La, Sookie;Kim, Jung-Han;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.400.1-400.1
    • /
    • 2002
  • Because of the differences in pharmacological properties between enantiomers of chiral acidic non-steroidal antiinflammatory drugs (NSAIDs) in human body. accurate determinations of their optical purities have been in great need. An efficient capillary electrophoretic (CE) profiling method was developed for the enantioseparation of NSAIDs. Capillary electrophoretic conditions were optimized using TM$\beta$-cyclodextrin as the chiral selectors under MES buffer. (omitted)

  • PDF

A Study on the Crevice Corrosion for Ferritic Stainless Steel by Micro Capillary Tube Method

  • Na Eun-Young;Ko Jae-Yong;Baik Shin-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.4
    • /
    • pp.179-182
    • /
    • 2004
  • The aim of this study is to investigate the initiation and propagation of crevice corrosion for ferritic stainless steel in artificial crevice based on micro capillary tube method. The 430 stainless steel in artificial crevice is potentiostatically polarized in different sodium chloride solutions. Potentiodynamic and potentiostatic polarization data were measured in situ. The potentials in the crevice were measured by depth profile using the 0.04 mm diameter micro capillary tube inserted in the crevice. The potentials in the crevice ranged from -220 mV to -360 mV vs SCE from opening to bottom of crevice, which are lower than the external surface potential, -200 mV vs SCE. Such a potential drop induced the change of the metal surface state from passive to active. The surface of metal is located in passive state in -200 mV but the inner surface keeps active state below -220 mV, Thus these results show that the It drop mechanism in the crevice was more objective for evaluation and the method was easier to reproduce. Therefore the potential drop is one of the reasons for crevice corrosion by measuring the potentials in narrow crevice with a new micro measuring system.

Analysis of cyanide free electroless Au plating solution by capillary elecrophoresis (캐피라리 전기 영동법에 의한 비시안 무전해 Au 도금액의 분석)

  • Han, Jaeho;Kim, DongHyun
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.2
    • /
    • pp.120-132
    • /
    • 2022
  • In the non-cyanide-based electroless Au plating solution using thiomalic acid as a complexing agent and aminoethanethiol as a reducing agent, analysis of each component constituting the plating solution is essential for the analysis of the reaction mechanism. And component analysis in the plating solution is important for monitoring component changes in the plating process and optimizing the management method. Capillary Electrophoresis (CE) method is rapid, sensitive and quantitative and could be readily applied to analysis of Aun+ ion, complexing agent and reducing agent in electroless Au plating solution. In this study, the capillary electrophoresis method was used to analyze each component in the electroless Au plating solution in order to elucidate the complex bonding form and the plating mechanism of the non-cyanide-based electroless Au plating bath. The purpose of this study was to establish data for optimizing the monitoring and management method of plating solution components to improve the uniformity of precipitation and stability. As a result, it was confirmed that the analysis of thiomalic acid as a complexing agent and Aun+ ions and the analysis of aminoethanethiol as a reducing agent were possible by capillary electrophoresis. In the newly developed non-cyanide-based electroless Au plating solution, it was confirmed that Aun+ ions exist in the form of Au+ having a charge of +1, and that thiomalic acid and Au+ are combined in a molar ratio of 2 : 1. In addition, it was confirmed that aminoethanethiol can form a complex by combining with Au+ ions depending on conditions as well as acting as a reducing agent.

Affinity chromatography and capillary electrophoresis for analysis of the yeast ribosomal proteins

  • Goyder, Miriam S.;Willison, Keith R.;Klug, David R.;DeMello, Andrew J.;Ces, Oscar
    • BMB Reports
    • /
    • v.45 no.4
    • /
    • pp.233-238
    • /
    • 2012
  • We present a top down separation platform for yeast ribosomal proteins using affinity chromatography and capillary electrophoresis which is designed to allow deposition of proteins onto a substrate. FLAG tagged ribosomes were affinity purified, and rRNA acid precipitation was performed on the ribosomes followed by capillary electrophoresis to separate the ribosomal proteins. Over 26 peaks were detected with excellent reproducibility (<0.5% RSD migration time). This is the first reported separation of eukaryotic ribosomal proteins using capillary electrophoresis. The two stages in this workflow, affinity chromatography and capillary electrophoresis, share the advantages that they are fast, flexible and have small sample requirements in comparison to more commonly used techniques. This method is a remarkably quick route from cell to separation that has the potential to be coupled to high throughput readout platforms for studies of the ribosomal proteome.

Analysis of Nano-contact Between Nano-asperities Using Atomic Force Microscopy (나노스케일 표면돌기 간의 미세접촉에 대한 해석)

  • Ahn, Hyo-Sok;Jang, Dong-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.369-374
    • /
    • 2009
  • In micro/nano-scale contacts in MEMS and NEMS, capillary and van der Waals forces generated around contacting micro-asperities significantly influence the performance of concerning device as they are closely related to adhesion and stiction of interacting surfaces. In this regard, it is of prime importance to accurately estimate the magnitude of surface forces so that an optimal solution for reducing friction and adhesion of micro/nano-surfaces may be obtained We introduced an effective method to calculate these surface forces based on topography information obtained from an atomic force microscope. This method was used to calculate surface forces generated in the contact interface formed between diamond-like carbon coating and $Si_3N_4$ ball. This method is shown to effectively demonstrate the influence of capillary force in the contact area, especially in humid atmosphere.

  • PDF

The Injection of PDLC Solution Mixture in a Reduced Pressure

  • Kim, Kang-Pil;Yang, Kee-Jeong;Kim, Dae-Hwan;Choi, Byeong-Dae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.524-526
    • /
    • 2007
  • Polymer dispersed liquid crystal (PDLC) films consist of micro-droplets of liquid crystals dispersed in a polymer matrix. To make wide area PDLC filled devices, it is necessary to develop reliable method of vacuum injection of PDLC solution instead of the capillary injection. However, well-known 2-ethylhexylacrylate (EHA), main element of a prepolymer, exhibits the volatility problems, when the PDLC solution is placed under the low pressure. In this study, we developed the vacuum injection process to fill a wide area cell. Experimental results indicate that the $V_{90}$(turn-on voltage) of the PDLC cell made by a vacuum injection method are lower than that of the PDLC cell made by a capillary injection method.

  • PDF

A Study of Contaminant Removal for Pore-Water Collection (토양 간극수의 효율적 포집을 위한 오염물질 제거에 관한 연구)

  • 이성백
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.69-73
    • /
    • 1999
  • The study was performed to examine the elimination capacity of impurity on the fiberglass wicks to exert a suction of Passive capillary samplers (PCAPS) on soil water. This impurity affects the capillary properties of the wick and the chemical properties of the samples collected. To determine the need, capillary rise and moisture contents were measured after the wicks were cleaned by four methods : combustion, acetone extraction, detergent washing, and uncleaning. The wicks were made with fibers produced by PPG Industries and Manville Company, U.S.A. Results showed that wicks made from PPG fibers lost up to 3.4% of original mass during combustion while Manville fiber wicks lost only up to 0.6%. These losses are assumed to have been due to combustion of organic compounds applied by the manufacturers. All cleaning methods had higher capillary rise than obtained with uncleaning method Combustion at 40$0^{\circ}C$ for 4 hours was the best cleaning method. removing 98 to 100% of impurities.

  • PDF

Study on the Image Analysis System of Nail-fold Capillary Vessel( I ) (인체를 대상으로 하는 혈허 혈어증 모델 개발을 위한 손톱 주름살의 모세혈관에 대한 영상장치 연구 ( I ))

  • Kim Gyeong Cheal;Hwang Won Deuk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.3
    • /
    • pp.789-791
    • /
    • 2004
  • We study on the video-capillaroscopy system for look a.t the nail fold capillary by the computer. This system is composed of the luminous source-producer, image-input, phase microscope. The method and contents of observation on this system are seperated from the image-analysis of nail fold capillary form-patterns and the currents of hematocytes. Therefore we think this system is possible to the practical clinic use for the basic model on the cardiac failure and the deficiency(血虛), stagnant(血瘀) of blood in human.