• 제목/요약/키워드: Capillary length

검색결과 137건 처리시간 0.021초

Analytical study on seepage behavior of a small-scale capillary barrier system under lateral no-flow condition

  • Byeong-Su Kim
    • Geomechanics and Engineering
    • /
    • 제35권1호
    • /
    • pp.13-27
    • /
    • 2023
  • The model production for large-scale (lateral length ≥ 2.0 m) capillary barrier (CB) model tests is time and cost-intensive. To address these limitations, the framework of a small-scale CB (SSCB) model test under the lateral no-flow condition has been established. In this study, to validate the experimental methodology of the SSCB model test, a series of seepage analyses on the SSCB model test and engineered slopes in the same and additional test conditions was performed. First, the seepage behavior and diversion length (LD) of the CB system were investigated under three rainfall conditions. In the seepage analysis for the engineered slopes with different slope angles and sand layer thicknesses, the LD increased with the increase in the slope angle and sand layer thickness, although the increase rate of the LD with the sand layer thickness exhibited an upper limit. The LD values from the seepage analysis agreed well with the results estimated from the laboratory SSCB mode test. Therefore, it can be concluded that the experimental methodology of the SSCB model test is one of the promising alternatives to efficiently evaluate the water-shielding performance of the CB system for an engineered slope.

닫힌 모세관에서 유체 이송에 관한 연구 (Investigation for the Fluid Motion in Closed End Capillaries)

  • 임호섭;임성진;이진기
    • 한국가시화정보학회지
    • /
    • 제12권2호
    • /
    • pp.23-29
    • /
    • 2014
  • Although many studies have been done on an open-end capillary, the invasion into a closed end capillary is still novel in its investigation. In this research we have explored the fluid invasion in closed-end capillaries where the shape of the meniscus and the height of invasion were accompanied by gas compression inside the capillary. Theoretically, the one dimensional momentum balance equation shows the fluid oscillation. In the experiments, we have found the different phenomena, either the fluid oscillation with low frequency or no oscillation. This discrepancy is mostly caused by two factors. First, a continuous decrease of the advancing contact angle due to decreasing invasion velocity as increasing pressure inside the closed-end capillary reduces the invasion velocities. Second, the high shear stress within the entrance length region was generated by the plug like velocity profile.

모세관 모델에 의한 다공층내의 증발 열전달 해석 (Analysis of Evaporative Heat Transfer in a Porous Layer by Capillary Model)

  • 김홍제;이진호
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.391-399
    • /
    • 1992
  • The analysis of the evaporative heat transfer in the inclined porous layer (0.deg.<.theta.<90.deg.) is made by using capillary model. The length of the evaporation zone is obtained numerically by integrating the differential equation using a Runge-Kutta algorithm. As a result, the length of the evaporation zone is inverse proportional to the dimensionless number, E(=Re*.phi./cos.theta.) representing the evaporation intensity, and the relationship of these parameters shows linear in the log graph.

R-600a 및 R-134a를 공용으로 사용한 소형 냉동사이클의 성능 특성 최적화에 대한 실험적 연구 (An Experimental Study on the Optimization of the Performance Characteristics of a Refrigeration System Using R-600a and R-134a)

  • 장의성;윤원재;정현준;정해원;김용찬
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.268-274
    • /
    • 2010
  • Because both R-134a and R-600a are used as a refrigerant of a household refrigerator in the global market, the home-appliance industry needs an optimized cycle for both refrigerants. The objective of this study is to provide the design guideline on the optimization of a refrigeration system using both refrigerants. For both refrigerants, the performance characteristics of the refrigeration system were tested by varying refrigerant charge amount, capillary tube length, suction diameter and SLHX length. The tested refrigeration system was optimized at the refrigerant charge of 60 g and the capillary tube length of 3600 mm with R-134a, and the refrigerant charge of 34 g and the capillary tube length of 3900 mm with R-600a. The COP increased from 1.63 to 1.68 for R-134a and increased from 1.37 to 1.48 for R-600a, respectively, by applying the suction diameter expansion. In addition, the COP of the R-134a and R-600a system decreased by 2.3~2.4% as the SLHX length decreased by 300 mm.

Temperature-controlled Restrictor for UV Detection in Capillary Supercritical Fluid Chromatography

  • Pyo, Dong-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권9호
    • /
    • pp.1429-1432
    • /
    • 2006
  • Polyaromatic hydrocarbons were separated by a capillary supercritical fluid chromatographic (SFC) column and detected by a UV detector at the wavelength of 280 $\mu$m. The temperature-controlled restrictor was designed for UV detection. The temperature-controlled restrictor is a 20 cm length of deactivated fused silica of 7 mm i.d. which is held right after UV detector of the capillary SFC. The temperature of the restrictor will control the flow rate of the supercritical carbon dioxide mobile phase through the capillary column in SFC. Thus as the pressure in the column is increased from 1500 psi to 4000 psi during a pressure program, the temperature of 7 $\mu$m fused-silica tube can be varied from 100 to 350 ${^{\circ}C}$ to maintain a constant flow rate.

가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구 (An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

비단열 모세관의 영향을 고려한 냉동 사이클 시뮬레이션 (Simulation of the Refrigeration Cycle Equipped with a Non-Adiabatic Capillary Tube)

  • 박상구;손기동;정지환;김윤수
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.131-139
    • /
    • 2009
  • The simulation of refrigeration cycle is important since the experimental approach is costly and time-consuming. The present paper focuses on the simulation of a refrigeration cycle equipped with a capillary tube-suction line heat exchanger(SLHX), which is widely used in small vapor compression refrigeration systems. The present simulation is based on fundamental conservation equations of mass, momentum, and energy. These equations are solved through an iterative process. The non-adiabatic capillary tube model is based on homogeneous two-phase flow model. This model is used to understand the refrigerant flow behavior inside the non-adiabatic capillary tube. The simulation results show that both of the location and length of heat exchange section influence the coefficient of performance (COP).

Capillary Gel Electrophoretic Analysis of Cattle Breeds Based on Difference of DNA Mobility of Microsatellite Markers

  • Lee, Mi-Ji;Yoon, Du-Hak;Jeon, Jin-Tae;Eo, Seong-Kug;Kang, Seong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권11호
    • /
    • pp.2655-2660
    • /
    • 2009
  • A breed of cattle, i.e., Korean cattle (Hanwoo), was identified based on the DNA mobilities of their microsatellites (MSs) by capillary gel electrophoresis (CGE) with a laser-induced fluorescence (LIF) detector. The MS markers were used for the accurate identification of species-specific genes. The DNA mobilities of the MS markers of Hanwoo and Holstein were measured using a CGE system with a fused-silica capillary (inner diameter of 75 ${\mu}m$, outer diameter of 365 ${\mu}m$, and total length of 50 cm). The capillary was dynamically coated with 1.0% (w/v) polyvinylpyrrolidone ($M_r$ = 1,000,000) and then filled with a mixture of 1.3% (w/v) poly(ethylene oxide) ($M_r$ = 600,000) and 1.9% (w/v) poly(ethylene oxide) (Mr = 8,000,000) as a sieving gel matrix. The species-specific genes of Hanwoo and Holstein were clearly distinguished within 33 min. This CGE assay technique is expected to be a useful analytical method for the fast and accurate identification of breeds of cattle.

Enhanced UV-Visible Absorbance Detection in Capillary Electrophoresis Using Modified T-Shaped Post-Column Flow Cell

  • Lim, Kwan-Seop;Kim, Su-Hyeon;Hahn, Jong-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.295-300
    • /
    • 2002
  • The construction of the T-shaped post-column flow cell has been changed to enhance the practicability as a UV-visible absorbance detector for capillary electrophoresis. In this new design, a rectangular cube-shaped inner structure is employed, which completely fits the outer rectangular tubing. This arrangement has greatly facilitated the fabrication of the T-cells. In addition, the volume for the auxiliary flow has been dramatically reduced down to 300 ${\mu}L$, and its volume flow rate is optimized at 4.2 ${\mu}L$/min. The short optical path length in the sheath flows (500 ${\mu}m$ on each side) minimizes background absorption, and thus enhances its performance in low-UV wavelengths. We have optimized the auxiliary flow rate at 50 ${\mu}m$/s, so that migration times are insensitive to the flow rate. This optimization has improved repeatabilities in migration times and peak heights. A double-beam detection scheme using a pair of photodiodes is employed to increase the signal-to-noise ratio.

Experimental Investigations on the Temperature Characteristics of Oscillating Heat Pipe with Various Filling Ratio

  • Jeong, Hyo-Min;Chung, Han-Shik;Lee, Kwang-Sung;Tanshen, Md.Riyad;Lee, Tae-Jin;Lee, Sin-Il
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.47-53
    • /
    • 2013
  • The article focuses on the Temperature characteristics inside single loop oscillating heat pipe (OHPs). In this paper, heat pipe is experimentally studied thereby providing vital information on the parameter dependency of their thermal performance. The impact depiction has been done for the variation of tube model of the device. OHPs are made of copper capillary tubes of outer diameter 6.25 mm, inner diameter 4 mm heated by constant temperature water bath cooled by ambient temperature. Using four types of OHPs of copper capillary tubes length of 1500mm and HP length 650mm inside tubes working fluid is R-22 Pressure 8 bar and mass 34g,32g,28g,16g. The results indicate a strong influence of filling ratio on the performance.