A Study of the Development of Liquid-liquid Static Contactor Using Capillary Phenomena Induced by Highly Packed Fiber Bundle and its Characteristics (고밀집 섬유 집합체에 의해 유도된 모세관 현상을 이용한 정적 액-액 접촉장치의 개발과 그 특성 연구)

  • Kim, Kwang-Wook;Byeon, Kee-Hoh;Lee, Eil-Hee;Yoo, Jae-Hyung;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.4
    • /
    • pp.743-749
    • /
    • 1996
  • A new static contractor using capillary phenomena induced by a highly packed fiber bundle was developed for the solvent extraction. When two immiscible phases being cocurrently and forcedly fed into the packed fiber bundle, the contactor brings about a very large liquid-liquid contact area for mass transfer within a small definite space without any turbulence and drop phenomena. In order to test the characteristics and stability of the static contractor system, continuous extraction experiments of TBP-uranyl ion-nitric acid system were done and compared with the batch extraction experiment of the same chemical system. The performance of the static contractor were the same as that of the ideal batch extractor with the same extraction condition. For the increase of the extraction yield by the contactor, the increase of organic flow rate was required at a fixed aqueous flow rate, and a certain residence time of the aqueous phase flow within the contactor system had to be maintained to meet the performance of the batch system of the same phase ratio. The residence time in the case of TBP-uranyl ion-nitric acid system was about 1.9 minutes. This system was confirmed to be effective and stable enough for purposes of the kinetic study of solvent extraction as well as the mutual separation and purification of ordinary materials because of good reproducibility and the stable and large static liquid-liquid contact area.

  • PDF

The Effects of a Foot-Reflex-Massage Education Program on Foot Care in Diabetic Patients (발반사요법 교육프로그램이 당뇨병 환자의 발관리에 미치는 효과)

  • 이영희
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.5
    • /
    • pp.633-642
    • /
    • 2003
  • Purpose: This study was conducted to evaluate the effects of foot care education program using foot-reflexo-massage in diabetic patients. Method: A convenience sample of non-equivalent control group time series design was used. It provided foot care education to diabetic patients through small book for both group. For the experimental group, foot-reflexo-massage was taught by a researcher and research assistants. Analysis was done by Repeated Measured ANOVA. Result: There was significant increase in foot care knowledge, self care behavior, between the experimental group and the control group over three different times. There was significant in skin temperature and pulse of foot over three different times and interaction by groups or over time, but there was no significant difference between groups. There was no significant difference in blood flow volume and capillary filling time over three different times, between groups, but there was interaction by groups or over time. But there was significant difference in discrimination in change of dosalis pedis artery blood flow. Conclusion: Findings indicate that this study may contribute to develop nursing intervention for foot care of diabetic patients.

An Experimental Study on the Effects of Porous Layer Treatment on Evaporative Cooling of an Inclined Surface (다공물질 표면처리가 경사판의 증발냉각에 미치는 영향에 관한 실험적 연구)

  • Lee Dae Young;Lee Jae Wan;Kang Byung Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Falling film heat transfer has been widely used in many applications in which heat and mass transfer occur simultaneously, such as evaporative coolers, cooling towers, absorption chillers, etc. In such cases, it is desirable that the falling film spreads widely on the surface forming thin liquid film to enlarge contact surface and to reduce the thermal resistance across the film and/or the flow resistance to the vapor stream over the film. In this work, the surface is treated to have thin porous layer on the surface. With this treatment, the liquid can be spread widely on the surface by the capillary force resulting from the porous structure. In addition to this, the liquid can be held within the porous structure to improve surface wettedness regardless of the surface inclination. The experiment on the evaporative cooling of an inclined surface has been conducted to verify the effectiveness of the surface treatment. It is measured that the evaporative heat transfer increases about $50\%$ by the porous layer treatment as compared with that from orignal bare surfaces.

Cycle Simulation of the Air-Conditioner Using Alternatives to R22 (R22의 대체냉매를 사용한 공기조화기의 성능 시뮬레이션)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 1994
  • Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.

  • PDF

Capillary Hysteresis Model in Unsaturated Flow - Development of Model - (비포화 흐름에서 모세관 이력현상 모형의 고찰 - 모형의 개발 -)

  • Park, Chang Kun;Sonu, Jung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.131-140
    • /
    • 1993
  • A new model which requires one branch of main curves for the model calibration is developed based on the assumption that the weighting factor accounting for the pore blockage effect against air entry, $P_a({\theta})$, in Mualem's Model III-1 has a linear relation to the dimensionless pore radius r. The proposed model simulates experimental data more accurately than existing models which require one branch of main curves for the model calibration. Previous study showed that Model III-1 is the most appropriate model among domain models which require two branches of main curves for the model calibration. In comparison of the proposed model with Model III-1, both simulate hysteresis curves with almost the same accuracy. The proposed model can be applied efficiently in analyzing the unsaturated flow.

  • PDF

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10$\^$17/ cm$\^$-3/, while downstream of the Mach dick tole values are about 25,000 K and 10$\^$18/ cm$\^$-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

Performance of a Heat pipe with Axial Grooves Formed from Corrugated Plate (접힌 板材 로 만든 그루우브 를 갖는 熱파이프 에 관한 硏究)

  • 김태현;김기현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 1985
  • Heat pipe with axial grooves formed from corrugated plate in the adiabatic section is studied. The axial grooves made of thin corrugated plate decrease considerably the flow resistance in the adiabatic section without increasing the thermal resistance of the heat pipe, resulting in the increase of the capillary limit, especially in the cases of heat pipes that have long adiabatic section. In the theoretical analysis, it is assumed that the liquid flow in each section laminar and fully developed and Darcy's equation can be applied to each section neglecting the end-effects associated with each transitionary region. A heat pipe which consists of axially corrugated rectangular grooves in the adiabatic section and bronze mesh in the evaporator and codenser sections was made and tested. Comparison of the experimental results, using acetone as the working fluid, with the theoretical result shows satisfactory agreement.

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreezing Solution (마이크로 부동액막을 이용한 착상방지에 관한 실험적 연구)

  • Chang Young- Soo;Yun Won -Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.459-467
    • /
    • 2005
  • The effect of anti freezing solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreezing solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation and reduce the thermal resistance across the film. A porous layer coating technique is adopted to improve the wettedness of the anti freezing solution on a parallel plate heat exchanger. The antifreezing solution spreads widely on the heat exchanger surface with 100 $\mu$m thickness by the capillary force resulting from the porous structure. It is observed that the antifreezing solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by thin liquid film are only $1\~2\%$ compared with those for non-liquid film surface.

Waste Isolation Pilot Plant Performance Assessment: Radionuclide Release Sensitivity to Diminished Brine and Gas Flows to/from Transuranic Waste Disposal Areas

  • Day, Brad A.;Camphouse, R.C.;Zeitler, Todd R.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.2
    • /
    • pp.450-457
    • /
    • 2017
  • Waste Isolation Pilot Plant repository releases are evaluated through the application of modified parameters to simulate accelerated creep closure, include capillary pressure effects on relative permeability, and increase brine and gas saturation in the operations and experimental (OPS/EXP) areas. The modifications to the repository model result in increased pressures and decreased brine saturations in waste areas and increased pressures and brine saturations in the OPS/EXP areas. Brine flows up the borehole during a hypothetical drilling intrusion are nearly identical and brine flows up the shaft are decreased. The modified parameters essentially halt the flow of gas from the southern waste areas to the northern nonwaste areas, except as transported through the marker beds and anhydrite layers. The combination of slightly increased waste region pressures and very slightly decreased brine saturations result in a modest increase in spallings and no significant effect on direct brine releases, with total releases from the Culebra and cutting and caving releases unaffected. Overall, the effects on total high-probability mean releases from the repository are insignificant, with total low-probability mean releases minimally increased. It is concluded that the modified OPS/EXP area parameters have an insignificant effect on the prediction of total releases.

An experimental study on the viscosity of visco-elastic fluids (점탄성유체의 점성에 관한 실험적 연구)

  • 김춘식;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.21-41
    • /
    • 1982
  • Viscosity, especially characteristic among various properties of visco-elastic fluids such as high polymer solutions, is affected mainly by temperature and concentration. Hence, it is important for fluid engineering to express, by some equations, how the fluid characteristics vary with the change of temperature and concentration and to analyze them to obtain consistent viscous characteristics. High polymer solutions, synthetic products of modern chemical industry, suggest many interesting investigations because they are typical visco-elastic materials. Experimentation was made to derive some useful fluid characteristic equations of SEPARAN-NP10 (polyacylamide) expressed by n (flow behavior index) and K' (consistency index) when it is given temperature and concentration variation. To measure viscosity, capillary viscometer was adopted and the range of experimentation is 0-2,000 P.P.M. in concentration and 15-55 .deg.C in temperature. The experimental results are summarized as follows: The flow behavior index n 1) has nearly constant results irrespective of temperature variation at same conentration and the results are shown in (Table. 4-4-3) 2) has following equation, regardless of temperature, for the variation of concentration. n=-1.0765*10$^{-4}$ P+0.9915 (P:P.P.M.) The consistency index K' 1) has different results for the variation of temperature at same concentration and the results are given in (Table.4-7-2) 2) has following equation for the variation of concentration at same temperature. log 10$^{4}$K' =6.4785*10$^{-4}$ P-1.0529 (P:P.P.M)

  • PDF