• Title/Summary/Keyword: Capillary flow

Search Result 382, Processing Time 0.028 seconds

The Effect of Vibration on the Hemorheological Characteristics of Non-aggregated Blood

  • Sehyun Shin;Ku, Yun-Hee;Moon, Su-Yeon;Suh, Jang-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.1104-1110
    • /
    • 2003
  • The present study investigates the hemorheological characteristics of blood flow with applying vibration to a non-aggregating red blood cell suspension. In order to obtain the non-aggregating RBC suspension, blood samples were treated with vibration at a specified condition, which viscosities were taken before and after the treatment, respectively. The viscosity of the blood samples after treatment was higher than before treatment. These treated blood samples were forced to flow through a capillary tube that was vibrated perpendicularly to the direction of the flow. The experimental results showed that vibration caused a reduction of the flow resistance of the non-aggregated blood. The reduction of the flow resistance was strongly dependent on both frequency and amplitude of vibration. These results show potential in treating various diseases in the microcirculation associated with blood cell aggregation.

Comparison of Shear-Thinning Blood Flow Characteristics between Longitudinal and Transverse Vibration

  • Choi, Sung-Ho;Shin, Se-Hyun;Lee, Kyung-Tae
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2258-2264
    • /
    • 2004
  • This article described the numerical investigation of shear-thinning blood flow characteristics when subjected to longitudinal and transverse vibrations and delineated the underlying mechanisms of the flow rate enhancements, respectively. In order to fully consider the mechanical vibrations of the capillary, a moving wall boundary condition was adopted. The present numerical results showed that the longitudinal vibration caused a significant increase of wall shear rates, which resulted in a decrease of viscosity and the subsequent increase of flow rates. However, the shear rate for the transverse vibration was slightly increased and the calculated flow rate was underestimated comparing with the previous experimental results.

Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device (바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구)

  • Choi, J.M.;Kim, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF

Experimental Study on Coffee-ring Effect of Silver Nanowire with Different Parameters (은 나노와이어 특성에 따른 커피 링 현상에 대한 실험적 연구)

  • Kang, Giho;Wang, Xiaofeng;Seong, Baekhoon;Lee, Hyungdong;Byun, Doyoung
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.2
    • /
    • pp.16-20
    • /
    • 2017
  • A coffee-ring effect is from capillary flow by different evaporation rate across the droplet. The capillary flow tends particles to accumulate at the edges of the droplet and makes the ring-shaped stain pattern. These coffee-ring formation and suppression of coffee-ring have been a critical role in printing and coating technologies. In this study, we present the experimental study on coffee-ring effect of silver nanowire inside the evaporating sessile droplet. Size and concentration effect of nanowires at coffee-ring effect has been investigated. From the coffee-ring, we observed the regimes of connected rings and disconnected ones and measure the resistivity of single ring pattern with different nanowire length.

A Study on the Related Factors and the Change after Foot-reflexo-massage Education Program for Diabetic Patients (당뇨병 환자의 발반사요법 교육프로그램 후 발관리지식, 자가간호행위, 생리적지표의 변화 및 관련요인분석)

  • Lee, Young-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.2
    • /
    • pp.222-232
    • /
    • 2004
  • Purpose: The purpose of this study was to identify the change in foot care knowledge, self care behavior, and physiologic indexes after foot reflexomassage education program, and the related factors. Method: Data were collected from 20 patients who were visited out patients clinic. The change and difference were analyzed with non-parametric statistics. Result: There were significant differences in foot care knowledge(P=.001), self care behavior(P=.000), dosalis pedis blood flow volume (P=.011), skin temperature of foot(P=.001), dorsalis pedis pulse(P=.000), capillary filling time of foot (P=.000) between pre and post. The level of changes of foot care knowledge was significant differences according to admission experience (P=.049), and negative related to systolic blood pressure(P=.028). The level of changes of self care behavior was related to age(P=.049), that of dosalis pedis blood flow was significant difference according to smoking(P=.042), that of skin temperatureof foot(P=.002) and dosalis pedis pulse(P=.038) were significant difference according to weight. The level of changes of capillary filling time of foot was related to diagnosis period(P=.014). Conclusion: Foot-Reflexo-Massage education program is an effective nursing intervention to promote foot care in diabetic patients. And the related factors can be recommended for the management of diabetic patients.

  • PDF

Computer Simulation of Die Extrusion for Rubber Compound Using Simplified Viscoelastic Model (간략화된 점탄성 모델을 적용한 고무 컴파운드의 압출 해석)

  • Kim, J. H.;Hong, J. S.;Choi, S. H.;Kim, H. J.;Lyu, M. Y.
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.54-59
    • /
    • 2011
  • One of the viscoelastic flow behaviors during profile extrusion is the swelling of extrudate. In this study, die swell of rubber compound in the capillary die have been investigated through experiment and computer simulation. Simplified viscoelastic model and non-linear differential viscoelastic model such as PTT model have been used in the computer simulation. The simulation results have been compared with experimental data. Experiment and simulation have been performed using fluidity tester and commercial CFD code, Polyflow respectively. Die swells predicted by two models showed good agreement with experimental results. Pressure and velocity distribution, and circulation flow at the corner of reservoir have been well predicted by PTT model. Simplified viscoelastic model can not predict circulation flow at the corner of reservoir. However this model has an advantage in computation time compare with full viscoelastic model, PTT model.

The Effect of Transverse Vibration on Red Blood Cell Aggregation and Blood Viscosity

  • Shin, Se-Hyun;Ku, Yun-Hee;Park, Myung-Su;Suh, Jang-Soo
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.2
    • /
    • pp.4-12
    • /
    • 2003
  • The present study investigated the effect of transverse vibration on the hemorheological characteristics of blood using a newly designed pressure-scanning capillary viscometer. As vibration was applied, aggregated blood cells (rouleaux) were disaggregated. The range of vibration frequency and amplitude are $0{\sim}100\;Hz$ and $0{\sim}0.8\;mm$, respectively for a capillary diameter 0.84 mm. As vibration increased, blood viscosity initially increased and tended to decrease. In order to delineate the unexpected results, the present study proposed two counteracting mechanisms of vibration related with red blood cell (RBC) aggregation affecting hemo-rheological properties. One is the reduction of RBC aggregation due to vibration causing an increase of blood viscosity. The other is forced cell migration due to the transverse vibration, which in turn forms a cell-free layer near the tube wall and causes a decrease of flow resistance.

  • PDF

Reorientation of Colloidal Crystalline Domains by a Thinning Meniscus

  • Im, Sang-Hyuk;Park, O-Ok
    • Macromolecular Research
    • /
    • v.12 no.2
    • /
    • pp.189-194
    • /
    • 2004
  • When water is evaporated quickly from a water-based colloidal suspension, colloidal particles protrude from the water surface, distorting it and generating lateral capillary forces between the colloidal particles. The protruded colloidal particles are then assembled into ordered colloidal crystalline domains that float on the water surface on account of their having a lower effective density than water. These colloidal crystal domains then assemble together by lateral capillary force and convective flow; the generated colloidal crystal has grain boundaries. The single domain size of the colloidal crystal could be controlled, to some extent, by changing the rate of water evaporation, but it seems very difficult to fabricate a single crystal over a large area of the water's surface without reorienting each colloidal crystal domain. To reorient such colloidal crystal domains, a glass plate was dipped into the colloidal suspension at a tilted angle because the meniscus (airwaterglass plate interface) is pinned and thinned by further water evaporation. The thinning meniscus generated a shear force and reoriented the colloidal crystalline domains into a single domain.

manufacturing micro CPL (Capillary Pumped Loop)by using LIGA process (LIGA process를 이용한 micro CPL(Capillary Pumped Loop)제작)

  • Cho, Jin-Woo;Jung, Suk-Won;Park, Joon-Shik;Park, Sun-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1881-1883
    • /
    • 2001
  • We manufactured a micro CPL by LlGA process, a new conceptual ultra-fine and precise forming method, using X-ray lithography process. We fabricated a BN X-ray mask having properties of good X-ray transmittance and large mechanical strength. Micro CPL was manufactured by dividing into an upper plate and a low plate. Each of plates was bonded by Ag paste screen printing. The upper plate was fabricated on glass wafer to observe flow and phase transformation of cooling solution. The lower plate was manufactured by Cu electroplating for good heat transmission. Precision of inner Parts, micro pin and micro channel, of manufactured micro CPL is under ${\pm}2{\mu}m$.

  • PDF

Blob and Wave Formation at the Free Edge of an Initially Stationary fluid Sheet (액체 필름 끝단에서의 유동특성에 관한 수치연구)

  • Song Museok;Ahn Jail
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.307-310
    • /
    • 2002
  • A two-dimensional numerical method for inviscid two-fluid flows with evolution of density interface is developed, and an initially stationary two-dimensional fluid sheet surrounded by another fluid is studied. The Interface between two fluids is modeled as a vertex sheet, and the flow field u÷th the evolution of interface is solved by using vortex-in-cell/front-tracking method. The edge of the sheet Is pulled back into the sheet due to surface tension and a blob is formed at the edge. This blob and fluid sheet are connected by a thin neck. In the inviscid limit, such process of the blob and neck formation is examined in detail and their kinematic characteristics are summarized with dimensionless parameters. The edge recedes at $V=1.06({\sigma}/{\rho}h)^{0.5}$ and the capillary wave Propagating into the fluid sheet must be considered for bettor understanding of the edge receding.

  • PDF