• Title/Summary/Keyword: Capacity ratio

Search Result 3,727, Processing Time 0.027 seconds

Buckling performance of pultruded glass fiber reinforced polymer profiles infilled with waste steel fiber reinforced concrete under axial compression

  • Emrah, Madenci;Sabry, Fayed;Walid, Mansour;Yasin Onuralp, Ozkilic
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.653-663
    • /
    • 2022
  • This study reports the results of a series of tests of pultruded glass fiber reinforced polymer (P-GFRP) box section composite profile columns, geometrically similar with/without concrete core, containing 0-1-2-3% steel fiber, with different lengths. The recycled steel wires were obtained from waste tyres. The effects of steel fiber ratio on the collapse and size effect of concrete filled P-GFRP columns under axial pressure were investigated experimentally and analytically. A total of 36 columns were tested under compression. The presence of pultruded profile and steel wire ratio were selected as the primary variable. The capacity of pultruded profiles with infilled concrete are averagely 9.3 times higher than the capacity of concrete without pultruded profile. The capacity of pultruded profiles with infilled concrete are averagely 34% higher than that of the pultruded profiles without infilled concrete. The effects of steel wire ratio are more pronounced in slender columns which exhibit buckling behavior. Moreover, the proposed analytical approach to calculate the capacity of P-GFRP columns successfully predicted the experimental findings in terms of both pure axial and buckling capacity.

Experimental study on bearing capacity of PFCC column-RC beam joint reinforced with CST

  • Ping Wu;Dongang Li;Feng Yu;Yuan Fang;Guosheng Xiang;Zilong Li
    • Steel and Composite Structures
    • /
    • v.47 no.1
    • /
    • pp.19-36
    • /
    • 2023
  • An experimental study of eleven PVC-FRP Confined Concrete (PFCC) column-Reinforced Concrete (RC) beam joints reinforced with Core Steel Tube (CST) under axial compression is carried out. All specimens are designed in accordance with the principle of "weak column and strong joint". The influences of FRP strips spacing, length and steel ratio of CST, height and stirrup ratio of joint on mechanical behavior are investigated. As the design anticipated, all specimens are destroyed by column failure. The failure mode of PFCC column-RC beam joint reinforced with CST is the yielding of longitudinal steel bars, CST and stirrups of column as well as the fracture of FRP strips and PVC tube. The ultimate bearing capacity decreases as FRP strips spacing or joint height increases. The effects of other three studied parameters on ultimate bearing capacity are not obvious. The strain development rules of longitudinal steel bars, PVC tube, FRP strips, column stirrups and CST are revealed. The effects of various studied parameters on stiffness are also examined. Additionally, an influence coefficient of joint height is introduced based on the regression analysis of test data, a theoretical formula for predicting bearing capacity is proposed and it agrees well with test data.

A Study on Development for Joint of Concrete Filled Steel Tube Column and P.C Reinforced Concrete Beam(2) -The Behaviors Properties of Joint with Key Parameter, such as Strength of Concrete, size of Panel Zone and Axial Force ratio- (콘크리트 충전강관 기둥과 PC 철근 콘크리트 보 접합부의 개발에 관한 연구(2) -콘크리트 강도, 판넬죤의 크기, 축력비를 변수로 한 접합부의 거동 특성-)

  • Park, Jung Min;Lee, Sung Jo;Kim, Wha Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.107-120
    • /
    • 1997
  • The purpose of this study is to develop composite structural system which is to have versatility in plan design and to improve economical efficieney, to maximise structural capacity than existing structural system. In this viewpoint, it was investigated to the properties of structural behaviors for i oint consisting of concrete filled steel square tube column and P.C reinforced concrete beam through a series of hysteretic behavior experiment. In the previous report, researched to the properties of joints with key parameters. such as Axial Force ratio and section types. From the based on previous results, this study investigated the properties of this joints with key parameters, such as strength of concrete, size of panel zone and Axial Force ratio. The obtained results are summarised as follows. (1) Investigating for the failure mode of the beam-to-column joint, the specimens of S,LL and LH series(except for L5H) presented flexural failure mode. (2) The initial stiffness of joint was increasd as the decrease of axial force ratio and increase of the concrete strength. (3) The rotation resisting capacity was effective as the increment of the concrete strength and decrement of the axial force ratio. (4) The emprical formula to predict the ultimate capacity of joint model to introduce decrease coefficient according to the axial force ratio to superimpose shearing strength of steel web(H section) and bending strength of reinforced concrete beam was expected.

  • PDF

Study on axial compressive behavior of quadruple C-channel built-up cold-formed steel columns

  • Nie, Shaofeng;Zhou, Tianhua;Liao, Fangfang;Yang, Donghua
    • Structural Engineering and Mechanics
    • /
    • v.70 no.4
    • /
    • pp.499-511
    • /
    • 2019
  • In this study, the axial compressive behavior of novel quadruple C-channel built-up cold-formed steel columns with different slenderness ratio was investigated, using the experimental and numerical analysis. The axial compressive capacity and failure modes of the columns were obtained and analyzed. The finite element models considering the geometry, material and contact nonlinearity were developed to simulate and analyze the structural behavior of the columns further. There was a great correlation between the numerical analyses and test results, which indicated that the finite element model was reasonable and accurate. Then influence of, slenderness ratio, flange width-to-thickness ratio and screw spacing on the mechanical behavior of the columns were studied, respectively. The tests and numerical results show that due to small slenderness ratio, the failure modes of the specimens are generally local buckling and distortional buckling. The axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns decrease with the increase of maximum slenderness ratio. When the screw spacing is ranging from 150mm to 450mm, the axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns change little. The axial compressive capacity of quadruple C-channel built-up cold-formed steel columns increases with the decrease of flange width-thickness ratio. A modified effective length factor is proposed to quantify the axial compressive capacity of the quadruple C-channel built-up cold-formed steel columns with U-shaped track in the ends.

Traffic Volume Criteria for Roundabouts Based on Left-Turn Ratio (좌회전 비율에 따른 회전교차로 전환기준 교통량 산정)

  • Cho, Hanseon;Kim, Young-chun;Ahn, Woo-young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.4
    • /
    • pp.54-67
    • /
    • 2016
  • All roundabouts are designed based on "Roundabout Design Guideline, Ministry of Land and Transportation, 2014" in Korea. The guideline also provides the traffic volume criteria to convert from signalized intersections to roundabouts. While the criteria are based on capacity of roundabouts, left-turn ratio and the number of lane on approaches are not considered to calculate the capacity of roundabouts. Therefore it is difficult to apply the traffic volume criteria in the real world. In this study, we studied the impact of left-turn ratio and the number of lane on approaches into capacity of roundabouts using micro-simulation. It was found that the capacity of roundabouts is changed according to left-turn ratio and the number of lane on approaches.

Closed-form Expressions for Capacity Bounds of MRT/MRC MIMO with Multiuser Diversity (다중사용자 다이버시티가 적용된 MRT/MRC MIMO의 Capacity Bound의 Closed-form 표현)

  • Lee, Myougn-Won;Mun, Cheol;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12A
    • /
    • pp.1223-1228
    • /
    • 2006
  • Closed-form expressions for capacity bounds of multiuser diversity combined with maximum ratio transmission (MRT) and maximum ratio combining (MRC) at each link are presented under the assumption of independent and quasi-static flat multiple-input multiple-output (MIMO) Rayleigh fading channels. The analysis results precisely agree with the numerical verification results and clearly show the impact of MRT/MRC on multiuser diversity.

A Study on Estimation of Bearing Capacity of Sand Compaction Pile by Centrifuge Model Tests (원심모형실험에 의한 모래다짐말뚝의 지지력 산정식 연구)

  • Yoo, Nam-Jae;Hong, Young-KiI;Jun, Sang-Hyun;Kim, Kyung-Soo
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.121-130
    • /
    • 2007
  • Centrifuge model tests were performed to find appropriate equations proposed previously of estimating the bearing capacity of the composite clayey soil reinforced with sand compaction pile. Model tests were carried out with changing the replacement ratio of SCP (20%, 40%, 70%), contents of fine materials (5%, 10%, 15%) and ratio of treated width to loading width (1B, 2B, 3B). Test results about bearing capacity of the composite ground were obtained by performing the surcharge load tests with measurements of applied loads and vertical displacement. Bearing capacities against bulging and shear failures were estimated by the existing equations. As results of comparing the estimated bearing capacity with experimental values the bearing capacities estimated by Greenwood's equation (1970) for bulging failure mode were similar to the test results.

  • PDF

Experimental investigation of the effects of pipe location on the bearing capacity

  • Bildik, Selcuk;Laman, Mustafa
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.221-235
    • /
    • 2015
  • A series of laboratory model tests were conducted to investigate the effects of buried pipes location on the bearing capacity of strip footing in cohesionless soil. The variables examined in the testing program include relative density of the sand, loading rate of tests, burial depths of pipe and horizontal distance of pipe to footing. The test results showed a significant increase in bearing capacities when embedment ratio of pipe and horizontal distance of pipe to footing were increased. Based on the test results, it can be concluded that the location of pipes and relative density of sand are main parameters that affect the bearing capacity of strip footing. However, loading rate has not considerable effect on bearing capacity.

Experimental investigation of the uplift capacity of group anchor plates embedded in sand

  • Emirler, Buse;Tolun, Mustafa;Laman, Mustafa
    • Geomechanics and Engineering
    • /
    • v.11 no.5
    • /
    • pp.691-711
    • /
    • 2016
  • In this study, the uplift capacity of anchor plates embedded in sand was investigated by conducting model tests. Square shaped anchors were used in the tests and parameters such as relative density of sand, embedment ratio (H/B), spacing ratio between anchors (S/B) and anchor configuration affecting the uplift capacity were investigated. Breakout factor and group efficiency which are dimensionless parameters were used to show the results. A series of finite element analyses and analytical solutions were additionally performed to ascertain the validity of the findings from the laboratory model tests and to supplement the results of the model tests. It can be concluded that the embedment depth in dense sand soil condition is the most important parameter with respect to the other parameters as to influencing the uplift capacity of group anchors.

A Study on the Evaluation of Flexural Capacity and Design Equation of FRP Reinforcement-Concrete Beams (FRP보강근-콘크리트보의 휨성능과 휨설계식의 평가 연구)

  • Ko, Dong Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.59-66
    • /
    • 2022
  • In this paper, the flexural capacity equation of FRP-bar reinforced concrete beams was verified by comparing the experimental results and flexural capacity obtained according to the ACI procedure. And, also the economic feasibility of FRP-bar reinforced concrete beams was analyzed by comparing nominal moment capacity of beams. The results of analysis were as follows, 1) GFRP concrete beams have lower flexural performance than reinforced concrete beams, whereas CFRP concrete beams have similar flexural performance to reinforced concrete beams under the same reinforcement ratio 2) Although the design moment increased as the compressive strength of concrete increased, the flexural performance of GFRP reinforced concrete beams was found to be lower than the reinforced concrete beams for all reinforcement ratios.