• Title/Summary/Keyword: Capacity factor, CF

Search Result 15, Processing Time 0.019 seconds

Prediction of long-term wind speed and capacity factor using Measure-Correlate-Predict method (측정-상관-예측법을 이용한 장기간 풍속 및 설비이용률의 예측)

  • Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.37-43
    • /
    • 2012
  • Long-term variations in wind speed and capacity factor(CF) on Seongsan wind farm of Jeju Island, South Korea were derived statistically. The selected areas for this study were Subji, having a year wind data at 30m above ground level, Sinsan, having 30-year wind data at 10m above ground level and Seongsan wind farm, where long-term CF was predicted. The Measure-Correlate-Predict module of WindPRO was used to predict long-tem wind characteristics at Seongsan wind farm. Eachyear's CF was derived from the estimated 30-year time series wind data by running WAsP module. As a result, for the 30-year CFs, Seongsan wind farm was estimated to have 8.3% for the coefficien to fvariation, CV, and-16.5% ~ 13.2% for the range of variation, RV. It was predicted that the annual CF at Seongsan wind farm varied within about ${\pm}4%$.

Analysis of Capacity Factors and Capacity Credits for Wind Turbines Installed in Korea (국내 풍력발전 설비의 이용률과 용량크레딧 분석)

  • Paik, Chunhyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.79-91
    • /
    • 2019
  • The capacity credit (CC) is a key metric for mid- to long-term power system capacity planning. The purpose of this study is to estimate the CCs of domestic wind turbines. Based on hourly capacity factor (CF) data during the seven years from 2011 to 2017, the new so-called probabilistic CF scheme is introduced to effectively reflect the variability of CFs on CC estimation. The CCs are then estimated through the CF-based method and the ELCC (Effective Load Carrying Capability) method reflecting the probabilistic CF scheme, and the results are compared. The results show that the CC value 0.019 for domestic wind turbines proposed in the $8^{th}$ Basic Plan for Electricity Supply and Demand corresponds to the CC with a confidence level slightly lower than 95%.

Experimental Study on the Cannabis Fructus on Exercise Capacity and Cognitive Function in Vascular Dementia Rat Model (마자인(麻子仁)이 치매병태모델의 운동과 인지기능에 미치는 실험적 연구)

  • Bae, Kil-Joon;Song, Min-Yeong;Choi, Jin-Bong;Kim, Seon-Jong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.1
    • /
    • pp.1-15
    • /
    • 2015
  • Objectives The aim of this study was to investigate the effects of Cannabis Fructus on exercise capacity and cognitive function in chronic hypoperfusion induced vascular dementia rat model. Methods Vascular dementia rat models were induced by chronic cerebral hypoperfusion through bilateral common carotid arteries occlusion (BCCAO). All rats were randomly divided into 4 groups: normal group; control group; CF I group (feeding Cannabis Fructus 100 mg/kg); CF II group (feeding Cannabis Fructus 300 mg/kg). In order to study the effects of oral administration of Cannabis Fructus on vascular dementia rat models, corner turn test, hole board test, radial arm maze test, passive avoidance test were taken and Acetylcholine (ACh) activity, Acetylcholinesterase (AChE) activity, serum of Vascular endothelial growth factor (VEGF) protein level were measured. Also histological findings of the liver, kidney, brain and the change of Tau immunoreactive neurons in hippocampus were observed. Results CF I and CF II showed significant improvement in corner turn test, hole board test, radial arm maze test, passive avoidance test, Acetylcholine (ACh) activity, Acetylcholinesterase (AChE) activity, the serum of Vascular endothelial growth factor (VEGF) protein level and the change of Tau immunoreactive neurons in hippocampus. CF I showed more significant effect than CF II in these tests. However in histological observations of the liver and kidney both CF I and CF II showed glomerular injury and hepatotoxicity. Conclusions These results suggest that Cannabis Fructus was helpful in improving exercise capacity and cognitive function on Chronic hypoperfusion induced Vascular Dementia rats. However Cannabis Fructus affects the liver and kidney, therefore suggest that this is an area for further study.

Evaluation of the Wind Power Penetration Limit and Wind Energy Penetration in the Mongolian Central Power System

  • Ulam-Orgil, Ch.;Lee, Hye-Won;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.852-858
    • /
    • 2012
  • This paper describes evaluation results of the wind power penetration limit (WPPL) and the wind energy penetration (WEP) in the Mongolian central power system (MCPS). A wind power plant (WPP) in a power system possesses an output power limit because the power system must maintain a balance between the generation and consumption of electricity at all times in order to achieve an adequate level of quality. The instantaneous penetration limit (IPL) of wind generation at a load is determined as the minimum of the three technical constraints: the minimum output, the ramp rate capability, and the spinning reserve of the conventional generating units. In this paper, a WPPL is defined as the maximum IPL divided by the peak load. A maximal variation rate (VR) of wind power is a major factor in determining the IPL, WPPL, and WEP. This paper analyzes the effects of the maximal VR of wind power on the WPPL, WEP, and capacity factor (CF) in the MCPS. The results indicate that a small VR can facilitate a large amount of wind energy while maintaining a high CF with increased wind power penetration.

Measured AEP Evaluations of a Small Wind Turbine using Measured Power Curve & Wind Data (측정 출력곡선과 기상자료를 이용한 소형 풍력발전기 연간 발전량 비교평가)

  • Kim, Seokwoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.32-38
    • /
    • 2013
  • In an efforts to encourage renewable energy deployment, the government has initiated so called 1 million green homes program but the accumulated installation capacity of small wind turbine has been about 70kW. It can be explained in several ways such that current subsidy program does not meet public expectations, economic feasibility of wind energy is in doubt or acoustic emission is significant etc. The author investigated annual energy production of Skystream 3.7 wind turbine using measured power curve and wind resource data. The measured power curve of the small wind turbine was obtained through power performance tests at Wol-Ryoung test site. AEP(Annual Energy Production) and CF(Capacity Factor) were evaluated at selected locations with the measured power curve.

Power Curve of a Wind Generator Suitable for a Low Wind Speed Site to Achieve a High Capacity Factor

  • Yoon, Gihwan;Lee, Hyewon;Lee, Sang Ho;Hur, Don;Cheol, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.820-826
    • /
    • 2014
  • It is well known that energy generated by a wind generator (WG) depends on the wind resources at the installation site. In other words, a WG installed in a high wind speed area can produce more energy than that in a low wind speed area. However, a WG installed at a low wind site can produce a similar amount of energy to that produced by a WG installed at a high wind site if the WG is designed with a rated wind speed corresponding to the mean wind speed of the site. In this paper, we investigated the power curve of a WG suitable for Korea's southwestern coast with a low mean wind speed to achieve a high capacity factor (CF). We collected the power curves of the 11 WGs of the 6 WG manufacturers. The probability density function of the wind speed on Korea's southwestern coast was modeled using the Weibull distribution. The annual energy production by the WG was calculated and then the CFs of all of the WGs were estimated and compared. The results indicated that the WG installed on the Korea's southwestern coast could obtain a CF higher than 40 % if it was designed with the lower rated speed corresponding to the mean wind speed at the installation site.

Recommendation of P and K Fertilizers for Crops Based on Soil Testing (토양분석치(土壤分析値)에 의(依)한 작물별(作物別) 인산(燐酸) 및 가리시비량(加里施肥量) 결정법(決定法))

  • Hong, Chong Woon;Kim, Yung Sup;Kim, Yung Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.1
    • /
    • pp.29-31
    • /
    • 1973
  • Upon the assumption that the available components in the soil evaluated by present analytical procedures, are as effective as the components applied to the soil as fertilizer, some formulas for the calculation of fertilizer requirements (F. R) for crops are suggested. Basically, the formulas are derived by combining the country average values of soil test data(${\overline{ST}}$) and of the optimum rate of fertilizers (ORF) for crops obtained from N.P.K. trials in farmer's field, as following. $$F.R(kg/10a)={\overline{ST}}(kg/10a)+ORFkg/10a-ST(kg/10a)$$ where, ST denotes the available components tested in the soil under question. Although this formula can be used both for P and K fertilizers, considering the significance of the potassium saturation rate of the soil for the availability of K, for the calculation of K fertilizer requirement, following formula is suggested. $$F.R(kg/10a)=(C.E.C.{\times}B.S.R.K.-KST(me/100g){\times}CF$$ where, B. S. R. K. is the basic potassium saturation rate of the soil and CF is conversion factor for the conversion of K me/100g into $K_2O$ kg/10a. The B. S. R. K. for different crops are obtained from the country average values of soil exchangeable K (${\overline{KST}}$), cation exchange capacity (CEC) and the optimum rates of K fertilizers for crops (ORF $K_2O$). $$B.S.R.K.=\frac{{\overline{KST}}{\times}CF+ORF(K_2O)}{CEC{\times}CF}$$ Using these formulas, equations for P and K fertilizer requirements for rice, barley, wheat, corn, italian millet, soy bean, sweet potato, potato and rape are derived.

  • PDF

Effect of Counter Anions on Solid Electrolyte Interphase Formation on Graphite Electrodes in Propylene Carbonate-based Electrolyte Solutions

  • Song, Hee-Youb;Kim, Seong In;Nogales, Paul Maldonado;Jeong, Soon-Ki
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.55-60
    • /
    • 2019
  • Herein, the effect of counter anions on the formation of a solid electrolyte interphase (SEI) in a propylene carbonate (PC)-based electrolyte solution was investigated. Although the reversible capacities were different, reversible intercalation and de-intercalation of lithium ions occurred in the graphite negative electrode in the PC-based electrolyte solutions containing 1 M $LiClO_4$, $LiPF_6$, $LiBF_4$, and $LiCF_3SO_3$ at low temperature ($-15^{\circ}C$). This indicated that the surface films acted as an effective SEI to suppress further co-intercalation and decomposition reactions at low temperature. However, the SEIs formed at the low temperature were unstable in 1 M $LiPF_6$ and $LiBF_4/PC$ at room temperature ($25^{\circ}C$). On the other hand, increasing reversible capacity was confirmed in the case of $LiCF_3SO_3/PC$ at room temperature, because the SEI formed at the low temperature was still maintained. These results suggest that counter anions are an important factor to consider for the formation of effective SEIs in PC-based electrolyte solutions.

Analysis of LCOE for Korean and Foreign Onshore Wind Turbines in Operation in Korea (국내에서 운영 중인 국산과 외국산 육상풍력발전기의 발전원가 분석)

  • Keon-Woo Lee;Kyung-Nam Ko
    • Journal of Wind Energy
    • /
    • v.14 no.3
    • /
    • pp.54-60
    • /
    • 2023
  • In order to reveal the levelized cost of energy (LCOE) of Korean and foreign wind turbines, a study was conducted for Korean onshore wind farms. Actual CapEx and OpEx data were obtained from audit reports for 26 onshore wind farms corresponding to 53.87 percent of the total onshore wind farms in Korea in the Data Analysis, Retrieval Transfer (DART) system. In addition, capacity factor (CF) data were calculated from data provided by Statistics Korea. Random numbers were generated from distributions that were fitted by the datasets, which were used as input data to perform a Monte Carlo simulation (MCS). The levelized fixed cost (LFC) and the levelized variable cost (LVC) were calculated from distributions of the CapEx, the OpEx and the CF. As a result, the LCOEs of the analyzed total Korean wind farms, and Korean and foreign wind turbines were 147, 148, and 146 USD/MWh, respectively. The averaged LCOE of Korea was estimated to be 4 USD/MWh lower than that of Japan, while it was much higher than German and global averages.

A Study for Efficiency Improvement of Feedforward Power Amplifier by Using Doherty Amplifier (Doherty증폭기를 이용한 Feedforward전력 증폭기의 효율 개선에 관한 연구)

  • Lee Taek-Ho;Jung Sung-Chan;Park Cheon-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1059-1066
    • /
    • 2005
  • This paper reports an application of Doherty amplifier for efficiency improvement of feedforward power amplifier(FPA). For performance analysis, we measured 15 W average output power using WCDMA 4FA input signal with a center frequency 2.14 GHz. The applied Doherty amplifier presents the characteristics of high efficiency and low linearity in comparison to the class AB amplifier, and it was used as main amplifier of FPA fir efficiency improvement. To analyze the change of characteristic, tow Doherty amplifiers whose linearity and efficiency are different were applied. The applied FPAs are improved about $2\%$ or more performance in efficiency, but decreased in linearity on 15 W average output power. We additionally modified the coupling factor(CF) of the error loop and the error amplifier capacity for linearity improvement. Aa a result, the efficiency improvement and high linearity resulted from the change of CF and error amplifier capacity. However, we think if the linearity of Doherty amplifier were more than 35 dBc, the FPA would improve the performance about $2\%$ or more efficiency and maintain enough linearity.