• Title/Summary/Keyword: Capacity analysis

Search Result 9,223, Processing Time 0.036 seconds

Study on Rainfall Interception Loss from Canopy in Forest(I) (삼림(森林)에서 임관(林冠)에 의한 강우차단(降雨遮斷) 손실(損失)에 관(關)한 연구(硏究)(I))

  • Kim, Kyong Ha;Woo, Bo Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.331-337
    • /
    • 1988
  • To investigate the effects of forest stand and stony characteristics on interception loss from canopy trees, throughfall and stemflow under the canopy of a pine stand and a hardwood stand were measured during 4-month periods July to October, 1986 at the Kwanak Arboretum near Anyang, and the data were analysed by correlation and regression methods. The man results obtained from this study are summerized as follows : 1. The overall throughfall collected during measurement period were 593.5mm(76.7%) in the pine stand and 663.1mm(81.8%) in the hardwood stand oui of total percipitation of 773.8mm. Combined regression analysis describes the relation between total precipitation(P) and throughfall(T) in the pine stand as T=-1.8675+0.8320 P. in the hardwood stand as T=-8179+0.8805P. 2. And the sum of stemflow from measurement of total precipitation in the pine stand and the hardwood stand were 37.4mm(4.8%) and 15.5mm(2%), respectively. In total precipitation less than 2.5mm, stemflow were not measured in both the pine stand and the hardwood stand. Regression equations for the pine stand and the hardwood stand are S=-0.6155+0.0698P, S=-0.0497+0.0183P. The mean slope and intercept of the individual regression of stemflow on rainfall for each fewest stand indicate the proportion of the rain diverted to the trunks and trunk water capacity, respectively. 3. Interception loss accounted for 142.9mm(18.5%) in the pine stand and 125.2mm(16.2%), in the hardwood stand. 4. By quadratic predictive model of relation between interception loss and total incident rainfall, the extent of variance in interception loss explained was about 72% and 61% in the pine stand and the hardwood stand respectively.

  • PDF

Ecological Characteristics and Management Program for Buffer Greens at Sinhyeon-Eup, Geoje-Si (거제시 신현읍 완충녹지의 생태적 특성 및 관리방안)

  • SaGong, Young-Bo;Lee, Soo-Dong
    • Korean Journal of Environment and Ecology
    • /
    • v.21 no.3
    • /
    • pp.243-256
    • /
    • 2007
  • The purpose of this paper is aimed at identifying the planting condition of greenbelt axis covering forests located at Sinhyeon-eup, Geoje-si and also establishing improvement plans for the ecological organization. The study was executed with buffer green space designed to mitigate noise, which is located at a halfway point linking Mt. Yukkyo(altitude of 50m) and Mt. Jungmae(altitude of 131m). The number of the biotope patterns was classified into 17 in total: the two are urbanized districts such as a townified district and streets and another 15 are greenbelts and open space such as forest biotope, inland water biotope, and landscaping tree plantations biotope. According to the analysis of biotope types, it was estimated that the making use of already established buffer greens as a linking medium with a foothold of Mt. Yukkyo and Jungmae, whose natural eco-system is well suited for habitation of living organism, is the one and only way to the influx of living organism into the downtown area. The green coverage rate of the base green area, sub-base green area and linkage green area was 160.29%, 128.37% and 44.37% respectively; the green capacity coefficient(i.e. GVZ[$Gr{\ddot{u}}nvolumezahl$]) for base green area, sub-base green area and linkage green area was $4.04m^3/m^2,\;3.95m^3/m^2\;and\;0.65m^3/m^2$ respectively. The base green area has constituted multi-layered vegetation structure and thus played a role as habitats for living organism and supply centre of species, whereas the sub-base green area has destroyed lower layer vegetation, and the linkage green area was in bad shape due to the lack of planting volume and damage of the shrub layer. Accordingly, this research paper intended to suggest detailed implementation plans for the improvement in landscape for city dwellers' use and relaxation; in other words, this paper focused on ecological build-up for the Influx of wild birds into the downtown area for the promotion of bio-diversity of species through the linkage of base green areas and the fostering of nature observing trails for citizens as well as the connecting of green areas through the build-up of roadside greens to make these green areas to be efficiently used as corridors for the influx of wild birds and bio-organism habitation and for citizens' using space.

A Study on the Establishment of Optimal Transportation Networks in Busan New Port (부산항 신항 최적의 교통망 수립에 관한 연구)

  • Park, Ho-Kyo;Choi, Yang-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.125-132
    • /
    • 2017
  • The development project of Busan New Port aims to be Logistics Hub Port but there are too many things to deal with ; enlargement of harbour, interport competition, modernization of harbour loading equipment and so on. At present, 23 berths of North and South container quay are in operation and 22 berths will be constructed on west and south-side by 2020. Namely, Busan New Port will operate 45 berths in 2020. When it comes to port distripark, a large-scale of Port distripark project is underway, such as Ung-Dong district 1,2 phase, West container 1,2phase, North distripark and so on. This study is to deduce traffic system problem of Busan New Port which is caused by the development project through predicting traffic need considering the development project. According to study, there are three main problems of traffic system : 1. traffic congestion caused on main crossroad, connecting second harbour back road. 2. It has been predicted that South-North road and traffic capacity of New Port road would lack compared to traffic volume-to-be-increased. Moreover, the detour volume of traffic is caused because New Port's 1st avenue and route 2 were not connected directly. Thus, this study suggests three kinds of improvement plan for smoother traffic flow. 1st. Operate roundabout on major intersection, for example, second harbour back road, west container wharf's subway corridors(South to North), and permit only right turn on sub-intersection. 2nd. Extend New Port road(North container's port road) by utilizing side walk and median. 3rd. Install exit ramp which utilizes Route 2 connecting New Port's 1st avenue and local road 1042. The method we used to analyze the effect of improvement is Vissim of Mircro Simulation Package.

The Analysis of Productivity of Oak Stand following to Site Quality and Crown Class (I) (입지(立地)와 수형급(樹型級)에 따른 참나무임분(林分)의 생산력(生産力) 분석(分析) (I))

  • Kim, Chi Moon;Kwon, Ki Won;Song, Ho Kyong;Moon, Heung Kyu;Park, Hong Joon
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.1
    • /
    • pp.9-21
    • /
    • 1983
  • The structures of oak stands were studied in relation to their productivity. Three plots classified by the site quality following to altitude, were selected on the oak stand located at Naryongri Eunsanmyun Buyeogun. The site qualities of the stand studied were generally estimated to be moderate in respect to some soil physical and chemical properties. Quercus variabilis was dominant species in the vegetation composition of the stand studied. The crown densities of the stand were varied from 65.4% in plot I to 78.2% in plot III and the parts, occupied with oak trees, ranged from 44.4% in plot I to 65.9% in plot III in the density. In the contrast to crown density, the growing stocks of oak trees ranged from $3.937m^3$ in plot I (73.4% of plot total) to $2.075m^3$ in plot III (84.3% of plot total). The occupied ratios, measured by crown class, exhibited dissimilarity between crown projection area and volume, and also the ratios brought into different patterns by plot. Highly significant correlations were proved between crown projection areas and volumes of individual oak trees by plot, but not proved in the relations by crown class. The cumulative growth, current annual increment and mean annual increment displayed various patterns by plot and by crown class in the heights, D. B. H. s and volumes of oak trees. The maximum values of current annual increment of height were generally recorded in 10 to 20 years, earlier than those of D. B. H. The mean annual increment of height, D. B. H. and volume maintained similar levels after about 10 years and fluctuated irregularly. The crown projection area and volume following to thinning decreased in the order of the thinning methods of grade A < grade B < crown thinning$90m^3/ha$ in about 40 years in the productivity of volume of the oak stand studied.

  • PDF

The effect of high omega-3, -6 fatty acid feeding on the free fatty acid profile and meat quality traits of pork loin (오메가-3, -6 지방산 고 함유 급이가 돼지 등심의 지방산조성과 품질특성에 미치는 영향)

  • Seol, Kuk-Hwan;Kim, Ki Hyun;Joo, Bum Jin;Kim, Jo Eun;Kim, Kwang-Sik;Kim, Young Hwa;Park, Jun Cheol;Lee, Mooha
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.3
    • /
    • pp.213-220
    • /
    • 2014
  • This study was conducted to evaluate the effects of high n-3 or n-6 diet on free fatty acid profile and meat quality traits of pork loin. The 20 heads of commercial $Landrace{\times}Yorkshire{\times}Duroc(LYD)$ crossbreed pigs ($90.9{\pm}2.4BWkg$) were divided into four groups by added fat and oils, such as 5% tallow (Control), 5% linseed oil (T1), 5% safflower oil (T2), and mixture of linseed oil (2.5%) + safflower oil (2.5%) (T3), then reared 4 weeks. Pork loins were taken after slaughter, then sliced in 2 cm thickness and put in low-density polyethylene (LDPE) bag for analysis. T1 showed significantly high concentration of linolenic acid ($2.35{\pm}0.21%$) (p<0.05). The total amount of saturated fatty acids (SFA), mono-unsaturated fatty acids (MUFA) and poly-unsaturated fatty acid (PUFA) was significantly high in T1 ($36.05{\pm}1.18%$), C ($22.60{\pm}2.11%$) and T2 ($47.80{\pm}1.29%$), respectively (p<0.05). However, the ratio of n-6:n-3 was significantly low in T1 ($11.57{\pm}0.90$) than that of T2 ($37.56{\pm}12.51$) (p<0.05). There was no signigicant difference in lightness, redness, pH, water holding capacity and cooking loss between treatments (p>0.05). However, the yellowness of T2 was significantly higher than others (p<0.05). From those results, it was considered that feeding high n-3 and n-6 fatty acid diet to pig enables modify fatty acid profile of pork without any side effect on meat quality.

An Effectiveness Analysis of Landscape Management for the Historic and Cultural Environment Preservation Area of the Pungnammun Gate, Jeonju, by Applying 3D Visual Exposure (3차원 시각노출도를 이용한 전주 풍남문 역사문화환경보존지역의 경관 관리 효과 분석)

  • Lee, Jae-Yong
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.2
    • /
    • pp.30-37
    • /
    • 2018
  • The uniformed regulations for control of the height of buildings owned by individuals to protect landscape of cultural properties are causing serious social conflicts by limiting the development of landowners. It is urgent need of introducing indicators that can resolve such conflicts and evaluate the regulations of buildings, which can satisfy urban development as well as landscape management of cultural properties. Therefore, the purpose of this study is to simulate landscape changes according to the Cultural Heritage Protection Act and National Land Planning and Utilization Act by using Unity3D in the Pungnammun Gate(Treasure No. 308) of Jeonju and its surroundings, where architectural cultural property forms the symbolic landscape of the city. Then some items such as view points, target points were introduced and the quantitative evaluation of landscapes was attempted by applying the indicator of 3D Visual Exposure. As a result, the viewing opportunity and viewing area of Pungnammun Gate were not significantly influenced by changes in landscape according to the two laws. However, the change of the height of buildings by the National Land Planning and Utilization Act, which has the greatest development capacity, confirmed the possibility of weakening the identification of the Pungnammun Gate by increasing 3D Visual Exposure of the background buildings more than two times. Finally, it was confirmed that the skyline of Pungnammun Gate was clearly infringed upon development under the National Land Planning and Utilization Act, but the skyline was maintained similar to the current situation in the regulation by the Cultural Heritage Protection Act. Thus, this study is meaningful in that the application of 3D Visual Exposure showed the possibility of utilization as an indicator for quantitatively evaluating the protection of view on cultural property and skyline according to the changes of building heights.

Effect of Particle Size on Physico-Chemical Properties and Antioxidant Activity of Corn Silk Powder (옥수수수염 분말의 입자크기별 이화학적 특성과 항산화활성)

  • Cha, Sun-Mi;Son, Beom-Young;Lee, Jin-Seok;Baek, Seong-Bum;Kim, Sun-Lim;Ku, Ja-Hwan;Hwang, Jong-Jin;Song, Beom-Heon;Woo, Sun-Hee;Kwon, Young-Up;Kim, Jung-Tae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.57 no.1
    • /
    • pp.41-50
    • /
    • 2012
  • The study was carried out to analyze the relationship between analysis of antioxidant activity and the level of functional components according to particle size of corn silk. Particle size was classified into 5 groups. By particle size distribution and color difference, the total phenol content and DPPH radical scavenging activity were observed. The particle sizes of corn silk were $199.17{\mu}m$, $178.27{\mu}m$, $85.48{\mu}m$, $27.4{\mu}m$ and $20.97{\mu}m$, respectively. The lightness of colored pigments was increased when the particle size was decreased. The contents of free sugar (fructose, glucose, galactose, sucrose, and maltose) of corn silk were analyzed using a HPLC. The total phenol contents by the particle sizes of corn silk were 2.01 mg/g, 2.02 mg/g, 2.06 mg/g, 2.26 mg/g and 2.26 mg/g, respectively. DPPH radical scavenging activities of samples were 21.00%, 21.75%, 22.90%, 24.35% and 23.67%, respectively. Antioxidative activities of Trolox and Fe(II) in corn silk were measured by ferric reducing antioxidant power (FRAP) assay and Trolox equivalent antioxidant capacity (TEAC) assay. TEAC values of samples were $2.36{\mu}mol$ TE / g dw, $2.81{\mu}mol$ TE / g dw, $3.20{\mu}mol$ TE / g dw, $3.36{\mu}mol$ TE / g dw, and $3.44{\mu}mol$ TE / g dw, respectively. FRAP values of samples were $11.67{\mu}mol$ Fe(II) / g dw, $12.80{\mu}mol$ Fe(II) / g dw, $13.43{\mu}mol$ Fe(II) / g dw, $13.85{\mu}mol$ Fe(II) / g dw and $15.95{\mu}mol$ Fe(II) / g dw, respectively. Total phenolic content and antioxidantive activities based on FRAP assay and TEAC assay were increased with decreasing particle size. In addition, DPPH radical scavenging activity was also increased. A significant correlation was also noted between DPPH radical scavenging activities and the content of phenolic compounds.

Arsenic Removal Using Iron-impregnated Ganular Activated Carbon (Fe-GAC) of Groundwater (철침착 입상활성탄(Fe-GAC)을 이용한 지하수 내 비소 제거기술)

  • Yoon, Ji-Young;Ko, Kyung-Seok;Yu, Yong-Jae;Chon, Chul-Min;Kim, Gyoo-Bum
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.589-601
    • /
    • 2010
  • Recently it has been frequently reported arsenic contamination of geologic origin in groundwater. The iron-impregnated ranular activated carbon (Fe-GAC) was developed for effective removal of arsenic from groundwater n the study. Fe-GACs were prepared by impregnating iron compounds into a supporting medium (GAC) with 0.05 M iron nitrate solution. The materials were used in arsenic adsorption isotherm tests to know the effect of iron impregnation time, batch kinetic tests to understand the influence of pH, and column tests to evaluate for the preliminary operation of water treatment system. The results showed that the minimum twelve hours of impregnation time were required for making the Fe-GAC with sufficient iron content for arsenic removal, confirmed by a high arsenic adsorption capacity evaluated in the isotherm tests. Most of the impregnated iron compounds were iron hydroxynitrate $Fe_4(OH)_{11}NO_3{\cdot}2H_2O$ but a mall quantity of hematite was also identified in X-ray diffraction(XRD) analysis. The batch isotherms of Fe-GAC for arsenic adsorption were well explained by Langmuir than Freundlich model and the iron contents of Fe-GAC have positive linear correlations on logarithmic plots with Freundlich distribution coefficients ($K_F$ and Langmuir maximum adsorption capacities ($Q_m$. The results of kinetic experiments suggested hat Fe-GAC had he excellent arsenic adsorption capacities regardless of all pH conditions except for pH 11 and could be used a promising adsorbents for groundwater arsenic removal considering the general groundwater pH range of 6-8. The pseudo-second order model, based on the assumption that the ate-limiting step might be chemisorption, provided the best correlation of the kinetic experimental data and explained the arsenic adsorption system f Fe-GAC. The column test was conducted to valuate the feasibility of Fe-GAC use and the operation parameters in arsenic groundwater treatment system. The parameters obtained from the column test were the retardation actor of 482.4 and the distribution coefficient of 581.1 L/mg which were similar values of 511.5-592.5 L/mg acquired from Freundlich batch isotherm model. The results of this study suggested that Fe-GAC could be used as promising adsorbent of arsenic removal in a small groundwater supply system with water treatment facility.

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Quality Characteristics of Fermented Pork with Korean Traditional Seasonings (한국 전통 양념을 이용한 발효 돼지고기의 품질 특성)

  • Jin, S.K.;Kim, C.W.;Lee, S.W.;Song, Y.M.;Kim, I.S.;Park, S.K.;Hah, K.H.;Bae, D.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.217-226
    • /
    • 2004
  • This study was canied out to evaluate the quality characteristics of the fermented pork with Korean traditional seasonings. The samples, outside muscle of pork ham were cut to cube(7 ${\times}$ 12 ${\times}$ 2cm) and five Korean traditional seasonings such as garlic paste(TI), pickled Kimchi(T2), pickled Kimchi juice(T3), soybean paste(T4), red pepper paste(T5) were seasoned by the proportions of meat to seasonings(1 : 1). The seasoned samples were fennented at - 1 ${\pm}$ 1$^{\circ}C$ for 20 days. According to proximate composition analysis, all pork samples contained protein 20 ${\sim}$ 22%, fat 3 ${\sim}$ 5%, moisture 64 ${\sim}$ 70% and ash 1.8 ${\sim}$ 2.0%. However, T5 had high crude fat level and relatively low moisture content. The highest pH among treatments was shown in TI whereas T3 showed the lowest. Water holding capacity(WHC) of T4 and T5 were higher, while those values were lower in T3 compared with other treatment. Shear force value was the highest in T5, while it was the lowest in T4. TBARS value of T3 was the highest, while that was the lowest in T4. Moreover the highest VBN value was observed in T4 due to fermentation of soy protein. However, the lowest VBN value shown in Tl indicated the inhibition of protein degradation by the garlic. The highest saccarinity was shown in T5 but it was the lowest of in T3. Salinity was shown to be high in T2 and low in T5. $L^*$ values of T4 was higher both at the surface and inner side of samples than the others but T5 showed the lowest value. T2 showed the highest $a^*$ value but T4 and T5 showed the lowest. In the result of sensory evaluation for cooked meat, T5 had the highest score in all item including overall acceptability, while T4 had the lowest score. Unsaturated fatty acid(UFA) ratio of T5 and n were 72.16 and 69.93 respectively, and the ratio of UFA/Saturated fatty acid(SFA) were higher in the order of T5 >T4> T3 >Tl >T2. Overall quality characteristics were higher in the order of T5 >T2 >Tl >T4 >T3.