• Title/Summary/Keyword: Capacity Design

Search Result 5,656, Processing Time 0.035 seconds

Optimization of the preparation method of citron (Citrus junos Sieb.) beverage containing hibiscus using response surface methodology (반응표면 분석법을 이용한 히비스커스 첨가 유자 음료 제조의 최적화)

  • Lee, Chang Joo;Lee, Woo Jin;Park, Jong Seok;Kim, Sung Woo;Jung, Sung Keun
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.187-194
    • /
    • 2021
  • This study aimed to optimize the preparation method of citron (Citrus junos Sieb.) beverages with hibiscus using response surface methodology (RSM). The experimental conditions were established using a central composite design with three independent variables as follows: ratios of citron (40~60%), citric acid (0.34~0.94%), and hibiscus (0.3~0.7%). The results indicate that an increase in the citron ratio contributed to increased sweetness and as the concentration of citron and hibiscus increased, the brightness of the citron beverage decreased and the yellowness increased. The citron ratio showed a significant correlation with the ABTS radical scavenging capacity. Among the 15 experimental groups, 4 representative samples showing statistical significance were selected, and sensory tests were performed, in comparison with commercially available products. As a result of the sensory test, four beverages prepared with the selected recipes showed higher preference than commercial beverages, and optimal recipe conditions were 40% citron, 0.34% citric acid, and 0.5% hibiscus.

Optimal Design Standard and Application of Low Cost, High Performance Scrubber for Absorbing Hazardous Gas (유해가스 흡수처리를 위한 저비용 고효율 스크러버의 최적 설계기준 및 현장적용 방안)

  • Jung, Ga-Young;Lim, Kyung-Min;Ma, Byung-Chol
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.39-45
    • /
    • 2021
  • Scrubbers that treat hazardous materials at workplaces have high treatment efficiency; however, the design is complex, and pumps need to be operated 24 hours a day, which can be costly. Therefore, to minimize the operating costs, small businesses do not install scrubbers, or operate them while circulation pumps are suspended. Hence, this study investigated the application of low-cost, high-performance scrubbers that can be used economically in small businesses. Low-cost, high-efficiency scrubbers are applied to bubble columns to utilize devices for hazardous chemical absorption treatment purposes, and for the development of these scrubbers, absorption performance was reviewed and the optimal application method was studied under certain conditions. The changes in the absorption performance of hazardous gas were studied in certain environments by varying the physical conditions, and the optimal application methods were analyzed. The results showed that, while it was possible to treat some of the gas flowing into the low cost, high performance scrubber, the treatment capacity was reduced. Performance degradation was prevented by supplying an absorption liquid, and a certain level of absorption was maintained depending on the amount of circulation. Based on this, three types of site application methods of low cost, high performance scrubbers were presented. In addition, the appropriate timing of circulation and anti freezing measures were also discussed.

Design and operating parameters of multi-functional floating island determined by basic experiments of unit processes (단위공정별 기초실험을 통한 다기능 융복합부도의 설계·운전인자 도출)

  • Lim, Hyun-Man;Jang, Yeo-Ju;Jung, Jin-Hong;Yoon, Young-Han;Park, Jae-Roh;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.487-497
    • /
    • 2018
  • Water quality improvement processes for stagnant area consist mainly of technologies applying vegetation and artificial water circulation, and these existing technologies have some limits to handle pollution loads effectively. To improve the purification efficiency, eco-friendly technologies should be developed that can reinforce self-purification functions. In this study, a multi-functional floating island combined with physical chemical biological functions ((1) flotation and oxidization using microbubbles, (2) vegetation purification and (3) bio-filtration with improved adsorption capacity) has been developed and basic experiments were performed to determine the optimal combination conditions for each unit process. It has been shown that it is desirable to operate the microbubble unit process under conditions greater than $3.5kgf/cm^2$. In vegetation purification unit process, Yellow Iris (Iris pseudacorus) was suggested to be suitable considering water quality, landscape improvement and maintenance. When granular red-mud was applied to the bio-filtration unit process, it was found that T-P removal efficiency was good and its value was also stable for various linear velocity conditions. The appropriate thickness of filter media was suggested between 30 and 45 cm. In this study, the optimal design and operating parameters of the multi-functional floating island have been presented based on the results of the basic experiments of each unit process.

Development of Impact Factor Response Spectrum with Tri-Axle Moving Loads and Investigation of Response Factor of Middle-Small Size-RC Slab Aged Bridges (3축 이동하중을 고려한 충격계수 응답스펙트럼 개발 및 중소규모 RC 슬래브 노후교량 응답계수 분석)

  • Kim, Taehyeon;Hong, Sanghyun;Park, Kyung-Hoon;Roh, Hwasung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • In this paper the response factor is investigated for middle and small size-RC slab aged bridges. The response factor consists of static and dynamic response factors and is a main parameter in the frequency based-bridge load carrying capacity prediction model. Static and dynamic response factors are determined based on the frequency variation and the impact factor variation respectively between current and previous (or design) states of bridges. Here, the impact factor variation is figured out using the impact factor response spectrum which provides the impact factor according to the natural frequency of bridges. In this study, four actual RC slab bridges aged over 30 years after construction are considered and their span length is 12m. The dynamic loading test in field using a dump truck and eigenvalue analysis with FE models are conducted to identify the current and previous (or design) state-natural frequencies of the bridges, respectively. For more realistic considerations in the moving loading situation, the impact factor response spectrum is developed based on tri-axle moving loads representing the dump truck load distribution and various supporting conditions such as simply supported and both ends fixed conditions. From the results, the response factor is widely ranged from 0.21to 0.91, showing that the static response factor contributes significantly on the results while the dynamic response factor has a small effect on the result. Compared to the results obtained from the impact factor response spectrum based on the single axle-simply supported condition, the maximum percentage difference of the response factors is below 3.2% only.

Geometrical Analysis on Parts of Load Limit Valve for Static Structural Test of Aerospace Flight Vehicles (항공우주 비행체 정적구조시험용 하중제한밸브 부품 형상 분석)

  • Shim, Jae-Yeul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.9
    • /
    • pp.607-616
    • /
    • 2019
  • Free body diagram analysis is done for key parts of pilot stage of LLV (Load Limit Valve) which is used to protect overload for static structural test of aerospace flight vehicle. It is shown through the analysis that diameter ratio($D_2)^{ten}/D_2)^{comp}$) of two poppets in a pilot stage must be equal to piston area ratio($A_{comp}/A_{ten}$) of a hydraulic actuator for making a poppet open consistently at constant force applied by an actuator. The result of the analysis is verified by measuring geometries of the poppets in the four different LLVs which are corresponding to four actuators with different capacity and have been used after being imported in this laboratory. Results of "Adjuster resolution tests" with two different pilot stages show the max. deviation of Fi(actuator force in instant of opening poppet) from average Fi obtained for each turn of adjuster is 0.3KN and max. deviation of the Fi normalized by average Fi of each turn of adjuster is 3.7%. From the results, it is verified that the two pilot stages with same poppet diameter ratio make a poppet consistently open at Fis within ${\pm}3.7%$ deviation from the average Fi. The deviation is shown to be caused from frictional force of O-ring in the poppet. Additionally, design factors for poppet spring and adjuster, which are also key parts of the pilot stage, are distinguished and procedure for deciding the factors are also shown in this study.

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

AC Loss Characteristic Analysis of Superconducting Power Cable for High Capacity Power Transmission (대용량 전력 전송을 위한 초전도 전력케이블의 교류손실 특성 분석)

  • Lee, Seok-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.57-63
    • /
    • 2019
  • In order to facilitate the supply of gradually increasing power demand, it is also necessary to increase the number of power cables for power transmission as well as generation facilities. However, the expansion of electric power cables for supplying power to most urban areas requires a space for installation of additional cables, and the space for installing cables in domestic downtown areas is insufficient at present. The superconducting power cable, which can transmit more power with the same size, has emerged as an alternative to overcome the insufficient cable installation space. However, superconducting power cables, which have the advantage of large power transmission, have some losses in the AC (Alternating Current) system. Therefore, the design and analysis of AC losses are essential to introduce superconducting power cables in AC power transmission systems. In this paper, we analyze the AC loss of various superconducting power cables and consider the actual superconducting power cables and their application to the system. Although there is a theoretical calculation method of AC loss for single superconducting wire, it is not easy to calculate AC loss of superconducting power cable with large number. Therefore, the authors intend to analyze various kinds of superconducting power cable AC loss by using electromagnetic finite element analysis considering E-J (Electric field-Current density) characteristics of superconductivity. The analysis of the AC loss characteristics of the superconducting power cable will be an important factor in the design and development of the superconducting power cable to be applied to the actual system.

Design Considerations for Buffer Materials and Research Status of Enhanced Buffer Materials (완충재 설계시 고려사항 및 고기능 완충재 연구 현황)

  • Lee, Gi-Jun;Yoon, Seok;Kim, Taehyun;Kim, Jin-Seop
    • Tunnel and Underground Space
    • /
    • v.32 no.1
    • /
    • pp.59-77
    • /
    • 2022
  • Currently, the design reference temperature of the buffer material for disposing of high-level radioactive waste is less than 100℃, so if the heat dissipation capacity of the buffer material is improved, the spacings of the disposal tunnel and the deposition hole in the repository can be reduced. First of all, this study tries to analyze the criteria for thermal-hydraulic-mechanical performance of the buffer materials and to investigate the researches regarding the enhanced buffer materials with improved thermal conductivity. First, the thermal conductivity should be as high as possible and is affected by dry density, water content, temperature, mineral composition, and bentonite type. the organic content of the buffer material can have a significant effect on the corrosion performance of a canister, so the organic content should be low. In addition, hydraulic conductivity of the buffer material should be less than that of near-field rock and swelling pressure should be appropriate for buffer materials to function properly. For the development of enhanced buffer materials, additives such as sand, graphite, and graphite oxide are typically used, and a thermal conductivity can be greatly improved with a very small amount of graphite addition compared to sand.

A Study on the Direction of Restructuring of Educational Facility Management Operating System (학교 교육시설관리 지원시설 업무체계 재구조화 방안 연구)

  • Kim, Young-Bong;Lee, Yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.21 no.4
    • /
    • pp.21-28
    • /
    • 2022
  • This study analyzes the reality of the overall operating system, such as recognition and satisfaction with school field support work system of the Education Facilities Management Center, recognition level of restructuring of work areas, and the direction of improvement for school facility maintenance support in various types of future learning environments. To analyze the problem of this study, a survey was conducted on 290 education administrative officials in Gyeonggi-do. First, school site awareness and work performance satisfaction of the Educational Facilities Management Center were evaluated as "below average," and it is necessary to improve the qualitative work area that is practically helpful to schools. Second, in the area of organizational operation, it is desirable to avoid simple tasks with a low evaluation of "below average" and to switch to an operating system that improves efficiency. Third, the need for the facility environment area (professionalism, safety) was the highest, but the center's ability and work processing level were evaluated very low as "below average," so it is urgent to improve the center's capacity. Fourth, in the area of social and educational policy change, the center received a high score for the need for access from the perspective of a learning environment linked to future education. Therefore, a policy review on the restructuring and improvement of work areas suitable for this is necessary.

Evaluation of the Bending Properties of Glulam with Different Cross-Section (집성재 단면구성에 따른 휨성능 평가)

  • Lee, Jun-Jae;Kim, Kwang-Mo;Han, Jae-Su;Kim, Jae-Keon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.65-71
    • /
    • 2003
  • In this paper, bending capacities of glulams with different configurations of cross-section were evaluated. These configurations included horizontal(BH), vertical(BVN), vertical with vertical plywood (BVV) and vertical combination of lamination with horizontal plywood(BVH). Full-scale bending tests were performed to investigate the effect of different section configurations on bending strength(MOR) and stiffness(MOE) of glulam. Compared with type BH, MOR of glulam with type BVN configuration was improved about 23%, which was considered to be caused by defect dispersion effect, while MOE of glulams with these two types of configurations were similar. Because MOE of plywood is generally smaller than that of solid wood laminar, MOE of type BVH glulam decreased about 15%, but in the case of type BVV glulam, MOR was improved without any reduction of MOE. The reason of this result could be undersood in the view of shear-reinforcement effect, which was verified from analysis of fracture mode. From the results of this study, it was concluded that bending capacity of glulam could be improved by proper section design, such as laminar arrangement and shear reinforcement.