• 제목/요약/키워드: Capacity Design

검색결과 5,624건 처리시간 0.033초

Software for adaptable eccentric analysis of confined concrete circular columns

  • Rasheed, Hayder A.;El-Fattah, Ahmed M. Abd;Esmaeily, Asad;Jones, John P.;Hurst, Kenneth F.
    • Computers and Concrete
    • /
    • 제10권4호
    • /
    • pp.331-347
    • /
    • 2012
  • This paper describes the varying material model, the analysis method and the software development for reinforced concrete circular columns confined by spiral or hoop transverse steel reinforcement and subjected to eccentric loading. The widely used Mander model of concentric loading is adapted here to eccentric loading by developing an auto-adjustable stress-strain curve based on the eccentricity of the axial load or the size of the compression zone to generate more accurate interaction diagrams. The prediction of the ultimate unconfined capacity is straight forward. On the other hand, the prediction of the actual ultimate capacity of confined concrete columns requires specialized nonlinear analysis. This nonlinear procedure is programmed using C-Sharp to build efficient software that can be used for design, analysis, extreme event evaluation and forensic engineering. The software is equipped with an elegant graphics interface that assimilates input data, detail drawings, capacity diagrams and demand point mapping in a single sheet. Options for preliminary design, section and reinforcement selection are seamlessly integrated as well. Improvements to KDOT Bridge Design Manual using this software with reference to AASHTO LRFD are made.

개선된 기준으로 시공된 SIP 말뚝의 지지력 평가에 관한 연구 (Estimation of Bearing Capacity of SIP Pile Installed by Improved Criteria)

  • 박종배;김정수;임해식
    • 한국지반환경공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.5-15
    • /
    • 2004
  • SIP 공법이 국내에서 저소음 저진동 말뚝공법으로 널리 사용되고 있지만 품질관리기준이 명확히 정립되지 못하고 실무자들의 공법의 원리에 대한 이해 부족으로 시공시 혼선을 초래하고 있어 공법이 본래 가진 지지력을 충분히 발휘되지 못하고 있다. 이러한 문제점을 개선하기 위하여 2002년에 대한주택공사에서는 SIP 공법의 시공 및 재하시험기준을 개선하였다. 개선된 기준에 의하여 현장에 시공된 SIP 말뚝에 대하여 재하시험을 통하여 지지력을 평가한 결과 이전 방법으로 시공된 말뚝에 비하여 시공하중의 설계만족도 및 지지력 특성이 크게 향상된 것을 확인할 수 있었으며 이를 설계에 반영하면 기초 공사비도 절감할 수 있는 것으로 나타났다. 향상된 지지력 특성을 설계에 반영하기 위하여 재하시험결과를 국내에서 많이 사용하고 있는 말뚝 설계식들과 신뢰성 분석을 실시하여 적합식을 찾고자 하였다. 분석결과 개선된 기준으로 시공된 SIP 말뚝은 Meyerhof(1976)의 타입말뚝 설계식과 유사한 지지거동을 하는 것으로 나타났다.

  • PDF

정박지 용량지수를 활용한 대기정박지 수요 분석에 대한 기초 연구 (A Basic Study on the Demand Analysis of Waiting Anchorage using Anchorage Capacity Index)

  • 권승철;유용웅;박준모;이윤석
    • 해양환경안전학회지
    • /
    • 제25권5호
    • /
    • pp.519-526
    • /
    • 2019
  • 본 연구는 대기정박지의 신설 및 조정이 필요한 항만을 위해 정박지의 적정 용량을 산정하기 위한 방법론을 제시하고, 이를 진해만 내 항만과 부산에 적용하여 국내 주요 항만의 정박지 용량과 비교 분석하여 적용에 무리가 없는지 검토하기 위한 목적이 있다. 이를 위해 항만을 이용하는 선박의 총톤수 용량과 동시 정박 가능 용량의 개념을 정의하고 정박지 용량지수를 계산하여 대상항만을 위한 적정 정박지 용량을 산정하는데 이용하였다. 그 결과 진해만 내 항만의 정박지 용량지수는 0.89로 산출되었으며, 대기정박지 신설을 위한 적정 정박지 용량지수는 6.0 수준으로 분석되었다. 본 연구에서 제시한 정박지 용량지수의 개념을 정박지 설계 기준으로 반영할 경우 정박지를 이용하는 선박의 안전, 정박지 안전성 및 항만의 효율적인 운영에 도움을 줄 수 있을 것으로 판단된다.

가스 포일 스러스트 베어링의 하중지지 성능 및 구동 토크에 관한 실험적 연구 (Experimental Study on the Load Carrying Performance and Driving Torque of Gas Foil Thrust Bearings)

  • 김태호;이태원;박문성;박정민;김진성;정진희
    • Tribology and Lubricants
    • /
    • 제31권4호
    • /
    • pp.141-147
    • /
    • 2015
  • Gas foil thrust bearings (GFTBs) have attractive advantages over rolling element bearings and oil film thrust bearings, such as oil-free operation, high speed stability, and high-temperature operation. However, GFTBs have lower load carrying capacity than the other two types of bearings owing to the inherent low gas viscosity. The load carrying capacity of GFTBs depends mainly on the compliance of the foil structure and the formed hydrodynamic wedge, where the gas pressure field is generated between the top foil and the thrust runner. The load carrying capacity of the GFTBs is very important for the suitable design of oil-free turbomachinery with high performance. The aim of the present study is to identify the characteristics of the load carrying performance of GFTBs. A new test rig for the experimental measurements is designed to provide static loads up to 800 N using a pneumatic cylinder. The maximum operating speed of the driving motor is 30,000 rpm. A series of experimental tests—lift-off test, static load performance test, and maximum load capacity test—estimate the performance of a six-pad GFTB, in terms of the static load, driving torque, and temperature. The maximum load capacity is determined by increasing the static load until the driving torque rises suddenly with a sharp peak. The test results show that the torque and temperature increase linearly with the static load. The estimated maximum load capacity per unit area is approximately 80.5 kPa at a rotor speed of 25,000 rpm. The test results can be used as a design guideline for GFTBs for realizing oil-free turbomachinery.

Piled Raft 거동특성에 관한 실험적 연구 (An Experimental Study on Behavior for the Piled Raft)

  • 권오균;이승현;오세붕;임종석;이활
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 기초기술학술발표회
    • /
    • pp.77-89
    • /
    • 2002
  • To analyze a bearing capacity for pile groups, a number of model tests have been done and theoretical methods studied. In the case of design of group pile bearing capacity is calculated with only pile capacity. But uncertainty of bearing capacity and behavior of foundation cap(raft) leads to conservative design ignoring bearing effects of foundation cap. In the case of considering bearing capacity of foundation cap, the simple sum of bearing capacity of foundation cap and pile groups cannot be the bearing capacity of total foundation system. Since cap-pile-soil interaction affects the behavior of pile groups. Thus, understanding cap-pile-soil interaction is very important in optimal design. In this paper, the piled raft behavior is studied through model tests of 2$\times$2, 2$\times$3, 3$\times$3 pile group. Changes of behavior of pile group foundation by touching effects of foundation cap with soil are studied. Also changes of spacing between piles. Foundation cap is made of rigid steel plate and piles are made steel pipes. From this model tests, the changes of behavior changes of pile groups by touching effects of foundation cap with soil are studied.

  • PDF

동결농축법을 이용한 폐수처리시스템의 에너지 효율 향상에 관한 연구 (A study on energy efficiency improvement of waste-water treatment system by freeze concentration method)

  • 김정식;임승택;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.467-476
    • /
    • 2013
  • 동결농축법은 열역학적 효율이 높고 에너지 소비량이 작으며 처리수를 재활용할 수 있는 장점을 가지고 있다. 본 연구에서는 중소규모로 상용화 가능한 동결농축폐수처리시스템을 설계하고, 각 시스템의 에너지 소비효율과 일일처리량을 비교하여 시스템 개발방향을 제안하고자 하였다. 시스템을 완속운전시스템과 급속운전시스템으로 각각 모델링하고 해석을 통해 소비동력과 운전시간을 계산하여 비교한 다음 설계처리량에 따른 변화를 추가 검토하였다. 연구결과 급속운전시스템의 소비전력량비가 0.6 Wh/kg 만큼 다소 높으나 일일처리량은 19 % 증가하였으며, 설계처리량이 큰 시스템일수록 소비전력량비가 작아지고 일일처리량이 큰 결과를 얻었다.

능력스펙트럼을 이용한 가새형 소성 감쇠기의 설계 (Design of Unbend Braces Using Capacity Spectrum Method)

  • 최현훈;김유정;김진구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.260-267
    • /
    • 2001
  • In this study straightforward design procedure for unbond brace hysteretic dampers is developed. The required amount of equivalent damping to satisfy given performance acceptance criteria is obtained conveniently based on the capacity spectrum method without carrying out time-consuming nonlinear dynamic time history analysis. Then the size of the unbend braces is determined from the required equivalent damping. Parametric study is performed for the design variables such as natural period, yield strength, the stiffness after the first yield, yield stress of the unbond brace.

  • PDF

경전철 시험선용 전력공급시스템 설계 (The design of the traction power supply for the test line of Light Rail Vehicle)

  • 김국진;백병산;전용주;정상기;김남규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.322-328
    • /
    • 2001
  • In the electric railway systems, it is very important that we should design the system configuration, location and power capacity of substation. This paper presents the results of system configuration and system design of the DC traction power supply for the test line of Light Rail Vehicle. The voltage fluctuation of train and the power capacity of substation are calculated by computer simulation using the nodal equation, K.C.L/K.V.L, Ohm's law and superposition theory.

  • PDF

다목적 최적화 기법을 이용한 편심가새골조의 역량설계 (Capacity Design of Eccentrically Braced Frame Using Multiobjective Optimization Technique)

  • 홍윤수;유은종
    • 한국전산구조공학회논문집
    • /
    • 제33권6호
    • /
    • pp.419-426
    • /
    • 2020
  • 본 연구에서는 철골편심가새골조 시스템을 대상으로 다목적최적화기법을 통해 설계를 수행하고 그 결과를 분석하였다. 최적화 설계를 위해 유전 알고리즘의 일종인 NSGA-II를 활용하였다. 여기서, 목적함수는 이율배반적 관계를 갖는 구조물량과 층간변위로 하여 최소화되고, 제약조건에는 구조기준에서 요구하는 내력비, 링크의 회전각 등을 포함하였다. 제약조건은 최적화 알고리즘 내에서 각 항목을 위반할수록 목적함수 값을 크게 증가시키는 벌금함수의 형태를 가지고 있다. 설계기준에서 EBF 시스템의 설계규정은 링크 부재만 항복이 허용되며 나머지 부재는 링크 항복 시 발생되는 부재력을 탄성상태에서 견디도록 의도한 역량설계법에 기초한다. 그러나 최적화를 통해 도출된 결과 중 일부는 구조기준의 설계조항은 만족하지만 특정층 링크에 소성변형이 집중되어 연약층을 형성함으로써 기준에서 의도하는 역량설계의 원칙을 위배하는 결과가 나타났다. 이를 해결하기 위해 모든 링크의 전단 초과강도계수 중 최대값이 최소값의 1.25배를 넘지 않도록 하는 제약식을 추가하였다. 새로운 제약식을 추가한 경우 모든 최적해는 설계기준과 역량설계의 원칙을 준수하는 것으로 나타났다. 모든 설계안에서 보 경간에 대한 링크의 길이비는 전단링크의 범주에 해당하는 10% ~ 14%였다. 전체적으로 설계안들은 링크의 초과강도 계수비가 가장 지배적인 제약으로 작용하였으며, 구조기준의 요구사항 중 층간변위와 내력비 등의 항목에서 허용치에 비해 매우 보수적으로 설계되었다.

사질토를 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(VI) - 지반의 허용압축지지력 산정용 표해 또는 도해 - (A Study(VI) on the Development of Charts and Equations Predicting Bearing Capacity for Prebored PHC Piles Socketed into Weathered Rock through Sandy Soil Layers - Axial Compressive Bearing Capacity Prediction Table Solution or Chart Solution -)

  • 남문석;권오균;박민철;이창욱;최용규
    • 한국지반공학회논문집
    • /
    • 제35권11호
    • /
    • pp.75-95
    • /
    • 2019
  • 본 연구에서는 사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에 대한 수치해석 결과를 분석하여 정리한 도표 또는 도해로부터 매입 PHC말뚝의 동원지지력을 구하는 방법을 제안하였다. 즉, 수치해석 결과인 하중-침하량 곡선에서 5% 직경에 해당하는 침하량에서 발현된 사질토층의 동원주면마찰력, 풍화암층의 동원주면마찰력과 동원선단지지력을 산정할 수 있는 표해 또는 도해를 제안하였다. 이때 허용압축지지력은 동원 지지력에 안전율 3.0을 적용하여 산정하였다. 사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝의 허용압축지지력은 사질토층의 허용주면마찰력과 풍화암층의 허용주면마찰력 및 허용선단지지력을 합산하여 산정하는 것으로 제안하였고, 각 허용압축지지력 성분을 구할 수 있는 절차도 제시되어 있다. 본 연구에서 제안된 동원지지력 산정용 표해(또는 도해)를 사용할 경우, 적정 설계에서 PHC말뚝의 설계효율(DE)은 85%로 나타났으며, 따라서 최적 설계에서는 PHC말뚝의 장기허용압축하중(Pall) 까지도 활용할 수 있는 것으로 나타났다. 그리고 PHC말뚝의 우수한 압축하중 지지 성능을 효과적으로 활용하기 위하여 지반의 허용압축지지력(Qall)이 말뚝의 허용압축하중(Pall) 이상이 될 수 있도록 설계할 것을 권장하였다.