• Title/Summary/Keyword: Capacitor voltage control

Search Result 628, Processing Time 0.022 seconds

Transformer Parasitic Inductor and Lossless Capacitor-Assisted Soft-Switching DC-DC Converter with Synchronous Phase-Shifted PWM Rectifier with Capacitor Input Filter

  • Saitoh, Kouhei;Abdullah Al, Mamun;Gamage, Laknath;Nakaoka, Mutsuo;Lee, Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.217-221
    • /
    • 2001
  • This paper presents a new prototype of soft-switching DC-DC power converter with a high frequency transformer link which has two active power controlled switches in full bridge rectifier with capacitor input type smoothing filter. In this DC-DC converter, ZVS of the inverter in transformer primary side and ZCS of active rectifier area in secondary side can be completely achieved by taking advantage of parasitic inductor component of high-frequency transformer and loss less snubbing capacitors. Its operation principle and salient features are described. The steady-state operating characteristics of the proposed DC-DC power converter are illustrated and discussed on the basis of the simulation results in addition to the experimental ones obtained by 2kw-40kHz power converter breadboard set up.

  • PDF

The Study of Ripple Reduction of the PFC CCM Flyback Converter without Electrolytic Capacitor for LED Lightings using LC Resonant Filter (LC 공진 필터를 이용한 전해 커패시터 없는 LED 구동용 PFC CCM 플라이백 컨버터의 출력 전류 리플 저감에 관한 연구)

  • KIm, Choon-Tack;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.601-610
    • /
    • 2016
  • The light-emitting diode (LED) has been used in a variety of industrial fields and for general 0lighting purposes on account of its high efficiency, low power consumption and long lifespan. The LED is driven by direct current; therefore, an AC/DC converter is typically required for its use. An electrolytic capacitor is generally used for stabilizing DC voltage during use of the AC/DC converter. However, this capacitor has a short lifespan, which makes it a limiting factor in LED lighting. Furthermore, LED lighting requires a dimmable control to enable energy savings and fulfil a growing consumer demand. In this paper, the dimmable single-stage power factor correction (PFC) continuous conduction mode (CCM) flyback converter that employs no electrolytic capacitor is presented. The LC resonant filter is alternatively applied to reduce the 120[Hz] ripple on the output. And the optimum value of the LC resonant filter parameters considering both efficient and performance is analysed. Simulation and experimental results verify the satisfactory operation of the converter.

Power Factor Improvement of Single-Phase Three-level Boost Converter (단상 Three-level boost converter의 역률개선)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.384-387
    • /
    • 2000
  • In this paper Power factor correction circuit of single-phase three-level boost converter is proposed. The advantage of the proposed control scheme for three-level boost converter are low blocking voltage of each power device low THD(Total Harmonic Distortion) and high power factor. The control scheme is based on the current comparator capacitor compensator and region detector, In simulations the proposed system is validated.

  • PDF

Output Filter Design of Voltage Source Inverter for CVCF System (CVCF용 VSI의 출력필터 설계)

  • 김재식;최재호
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.287-290
    • /
    • 1999
  • This paper describes an optimal design method of VSI output filter for CVCF system. The cost function is used for design, and all parameters are described in p.u(per unit) so that can be adapted to the change of CVCF rating. The capacitor current feedback scheme is proposed to control the damping ratio of the filter plant to meet the system more stable. This means that the LC resonance can be suppressed well in transient condition and can use the same control gains under the change of system capacity. The validity of the proposed method is well verified with the theoretical analysis and simulation results.

  • PDF

Coordinated Wide-Area Regulation of Transmission System for Voltage Profile Improvement and Power Loss Reduction

  • Asadzadeh, Babak;Golshannavaz, Sajjad
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.279-286
    • /
    • 2017
  • In this paper, an optimal approach for the wide-area regulation of control devices in a transmission network is proposed. In order to realize an improved voltage profile and reduced power loss, existing devices such as tap-changing transformers, synchronous machines, and capacitor banks should be controlled in a coordinated and on-line manner. It is well-understood that phasor measurement units in transmission substations allow the system operators to access the on-line loading and operation status of the network. Accordingly, this study proposes efficient software applications that can be employed in area operation centers. Thus, the implanted control devices can be regulated in an on-line and wide-area coordinated approach. In this process, efficient objective functions are devised for both voltage profile improvement and power loss reduction. Subsequently, sensitivity analysis is carried out to determine the best weighting factors for these objectives. Extensive numerical studies are conducted on an IEEE 14-bus test system and a real-world system named the Azarbayjan Regional Transmission Network. The obtained results are discussed in detail to highlight the promising improvements.

The Triple Current Source Inverter System for Induction Motor Drive Using a One Chip Microcomputer (One Chip Microcomputer를 이용한 유도전동기 구동용 3동 전류형 인버어터시스템)

  • Chung, Yon-Tack;Jang, Seong-Chil;Hwang, Lak-Hoon;Lee, Hoon-Goo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.2
    • /
    • pp.162-172
    • /
    • 1991
  • In proportion to the capacity enlargement of the induction motor system controlled by current source inverter, the capacitance of the commutating capacitor is enlarged and then the spike value of output voltage is increased at the moment of charge and discharge. Moreover, the output currnet includes a number of harmonic components. Such voltage spike and harmonics generate the torque ripple and lead to bad effects on the performance of the induction motor. In this study, all the harmonics excluding 17th and 19th harmonics were mostly elimunated by adopting 18-phase Triple High Frequency Current Source Inverter(HFCSI), and the spike component of output voltage was reduced by adding the Voltage Clamping Circuit(VCC). As a result, the torque ripple and the commutation loss were reduced and the performance of the system was improved. Experiments for speed control were carried out in the tripple current source inverter system for induction motor drive. Overall system was controlled by ONE CHIP MICROCOMPUTER(INTEL 8751). Control circuits were simplified and good experimental results in the constant V/F control were obtained due to the flexibility of the microcomputer.

  • PDF

Analysis of the Hosting Capacity of the Distributed Generation and Voltage Regulation Devices Operation According to Reactive Power Control Scheme of the Inverter-based Distributed Generation (인버터 기반 분산전원의 무효전력 제어 특성에 따른 분산전원의 수용용량 및 전압조정 설비의 운영 계획 분석)

  • Cho, Gyu-Jung;Kim, Ji-Soo;Song, Jin-Sol;Shin, Jae-Yun;Kim, Dong-Hyun;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.809-815
    • /
    • 2018
  • Distributed generations (DGs) using renewable energy resources in power systems have been widely integrated, and many of these DGs have intermittency. DGs can significantly affect the overall voltage profile of the system through the reactive power control for a voltage support. Therefore, in the planning stage of the optimal operation and dispatch of voltage regulation devices, DGs' hosting capacity with the reactive power control scheme should be considered. In this paper, we model the IEEE 34-bus test feeder, including all essential equipment. An optimization method is utilized to determine the optimal siting and operation of the voltage regulation devices in the presence of DGs with reactive power control scheme. Finally, we compare the optimal results of the each case to analyze the relationship among the hosting capacity of the DGs and voltage regulation devices operation.

A Zero Sequence Voltage Injection Method for Cascaded H-bridge D-STATCOM

  • Yarlagadda, Srinivasa Rao;Pathak, Mukesh Kumar
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1088-1096
    • /
    • 2017
  • Load variations on a distribution line result in voltage fluctuations at the point of common coupling (PCC). In order to keep the magnitude of the PCC voltage constant at its rated value and obtain zero voltage regulation (ZVR), a D-STATCOM is installed for voltage correction. Moreover, the ZVR mode of a D-STATCOM can also be used to balance the source current during unbalanced loading. For medium voltage and high power applications, a D-STATCOM is realized by the cascaded H-bridge topology. In the ZVR mode, the D-STATCOM may draw unbalanced current and in this process is required to handle different phase powers leading to deviations in the cluster voltages. Zero sequence voltage needs to be injected for ZVR mode, which creates circulating power among the phases of the D-STATCOM. The computed zero sequence voltage and the individual DC capacitor balancing controller help the DC cluster voltage follow the reference voltage. The effectiveness of the control scheme is verified by modeling the system in MATLAB/SIMULINK. The obtained simulations are further validated by the experimental results using a dSPACE DS1106 and five-level D-STATCOM experimental set up.

The Output Characteristics of Transcranial Magnetic Stimulation with Voltage Variable Capacitor-Charging System

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.2
    • /
    • pp.205-211
    • /
    • 2010
  • In this study, a Magnetic stimulation Pulse Train control technique is introduced and applied to Flyback converter operating in discontinuous conduction mode. In contrast to the conventional pulse width modulation control scheme, the principal idea of a Magnetic stimulation Pulse Train is to achieve output voltage regulation using high and low power pulses. The proposed technique is applicable to any converter operating in discontinuous conduction. However, this work mainly focuses on Flyback topology. In this paper, the main mathematical concept of the new control algorithm is introduced and simulations as well as experimental results are presented.

Control of the Subsystem for a Power System (전력시스템을 위한 서브시스템의 제어)

  • Lee, Yong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.404-409
    • /
    • 2009
  • A DC power system has many loads with various functions. In particular, these sizable loads take the form of power electronic converters. When they are tightly regulated, the loads appear as constant power loads and result in negative incremental input impedance. Under certain conditions the effect of such loads on the power system is causes instability. In this paper, converter with a large storage capacitor and a lag compensator is proposed as a DC bus conditioner to mitigate the voltage transients on the bus. In addition, the proposed control approach has the advantage of performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. Simulation and experimental results showed that the proposed control method was operated well in a small-scale DC power system that contained subsystems with constant power characteristics, such as DC/DC converters and electrical drives.