• Title/Summary/Keyword: Capacitor discharge system

Search Result 82, Processing Time 0.024 seconds

A Study on Development of High Voltage Mica Capacitors (고전압 마이카 커패시터 개발에 관한 연구)

  • Yun, Eui-Jung;Choi, Cheal-Soon;Kim, Jae-Wook;Lee, Dong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1229-1234
    • /
    • 2008
  • In this work, ultra high-voltage (17 - 50 kV AC), reliable 80 pF mica capacitors for partial discharge system application were investigated. Mica was used as the dielectric of the capacitors. Using the conservative design rule, over 3 individual $50\;{\mu}m$ thick mica sheets with a size of 30mm{\times}35mm were used with lead foils to form a parallel capacitor element and 20 mica sheets were interleaved with lead foils to form a series stack of parallel capacitor element to meet the requirements of the capacitors. The dimensions of the fabricated 80 pF capacitors for 17 kV AC and 50 kV AC were $90\;mm{\times}90\;mm$ and $95\;mm{\times}180\;mm$, respectively. The high-frequency characteristics of the capacitance (C) and dissipation factor (D) of the developed capacitors were measured using a capacitance meter. The developed capacitors exhibited C of 79.5 - 87.5 pF, had D of 0.001% over the frequency ranges of 150 kHz to 50 MHz, had a self-resonant frequency of 65 MHz, and showed results comparable to those measured for the capacitors prepared recently by $Adwel^{Tm}$. The developed capacitors also showed excellent characteristics for thermal shock test and temperature cycling test.

Basic Studies on Development of Electrical Weed Control System (전기방전식 잡초방제기 개발을 위한 기초연구)

  • 김태한;장익주;이정택
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.303-310
    • /
    • 1997
  • Motivated by the need fir developing the new method of weed control in place of chemical weedicide, this paper aims at making good use of electricity against environmental pollution. Compared with chemical weedicide, the electric method of weed control is functionally more versatile, effectively more rapid, and lower in terms of cost. In particular, this method will contribute to environmental protection. In detail the electrical weed control system which is the simple circuit for generating the electric current of high voltage is comprised of step-up transformer which rectifies the current and the capacitor which stores the energy. The effectiveness of electrical weed control system is evaluated by germination rate and control of Dgitaria Sangvinalis(Galinsoga ciliate). As a result, the electrical weed control system(high voltage spark discharge) can kill weeds effectively

  • PDF

Development of Hardware for Controlling Abnormal Temperature in PCS of Photovoltaic System (태양광발전시스템의 PCS에서 이상 온도 제어를 위한 하드웨어개발)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.21-26
    • /
    • 2019
  • This paper is purposed to develop hardware for controlling abnormal temperature that can occur environment and component itself in PCS. In order to be purpose, the hardware which is four part(sensing, PLC, monitoring and output) keep detecting temperature for critical components of PCS and can control the abnormal temperature. Apply to the hardware, it is selected to PV power generation facilities of 20 kW in Cheong-ju city and measured the data for one year in 2017. Through the temperature data, it is found critical components of four(discharge resistance, DC capacitor, IGBT, DSP board) and entered the setting value for operating the fan. The setting values for operating the fan are up to $130^{\circ}C$ in discharge resistance, $60^{\circ}C$ in DC capacitor, $55^{\circ}C$ in IGBT and DSP board. The hardware is installed at the same PCS(20 kW in Cheong-ju city) in 2018 and the power generation output is analyzed for the five days with the highest atmospheric temperature(Clear day) in July and August in 2017 and 2018 years. Therefore, the power generation output of the PV system with hardware increased up to 4 kWh.

Experiental Study on the Electrostatic Discharge in the HDD Spindle System Using Fluid Dynamic Bearings (유체동압베어링을 사용하는 하드 디스크 드라이브 스핀들 시스템에서 발생하는 정전기 방전에 관한 실험적 연구)

  • Kang, Min-Gu;Jang, Gun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.318-323
    • /
    • 2005
  • This paper introduces the mechanism of the ESD (Electrostatic discharge) in the HDD spindle system using FDBs (Fluid Dynamic Bearings). When a HDD (Hard Disk Drive) spindle system is rotating, triboelectric charging occurs in the FDBs through the friction of the lubricant between the rotating shaft and stationary sleeve. And this electrostatic charge is accumulated in the rotating part of the HDD spindle system because it is insulated from the ground by the lubricant. This research shows experimentally that the behavior of electric charge and discharge in the FDB spindle system is the same as that of a capacitor. It also measures the electrostatic charge and discharge of the FDB spindle system due to the chanse of humidity, supporting load and motor speed. This research shows that the control of ESD is required in the HDD spindle system using FDBs, because the electrostatic charge accumulated in the FDB spindle system may cause the breakdown damage of the GMR head and data loss consequently.

  • PDF

Formation of Nanoparticles by Spark Discharge in Liquid (용액 내 스파크 방전을 이용한 나노입자 제조 및 특성 평가)

  • Choi, Hoomi;Kim, Jangah;Jung, Seungkyo;Yoon, Juho;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.37-43
    • /
    • 2012
  • In this study, we designed a 'spark in liquid' system. The spark discharge between two electrodes were used to generate particles by using sufficient temperature to evaporate a part of electrodes. The power supply system provides a continuous spark discharge by discharging of the capacitor to ionize the electrodes in liquid. The DC spark discharge system operates with 1-10 kV voltage. Processed copper and graphite rods were used to both electrodes with 1-3 mm diameter. There are several variables which can control the particle size and concentration such as gap distance between electrodes, applied voltage, operating liquid temperature, electrode type and liquid type. So we controlled these variables to confirm the change of particle size distribution and concentration of particles contained in liquid as wt%. 'spark in liquid' system is expected to apply nanoink by control of concentration with analysis of characteristics.

A Study of New Energy Storage System for PV System (PV 시스템 적용을 위한 새로운 에너지 저장 시스템 고찰)

  • Yu, Gwon-Jong;Jung, Young-Seok;Jung, Myung-Woong;Park, Yong-Sung;Choi, Jae-Ho;Choe, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1391-1393
    • /
    • 2002
  • There arc some problems on storage batteries which are called Secondary Battery, such as long charging time, limited cycle life, low coulomb efficiency and inaccurate residual power meter. To solve those problems, a complex system of capacitors and Super Capacitors of increased energy density. Though the capacitors alone arc not capable of delivering stable output, the accompanied circuits compensate the various characteristics all through the charge-and discharge-cycle. This paper deals with Energy Storage System with Super Capacitor for PV System Discussed in this paper are, explains the accompanied circuits of Super Capacitor which is compared with the Second Batteries.

  • PDF

Development of Charger/Discharger to Test Performance for EDLC (EDLC를 위한 성능시험용 충방전기 개발)

  • Kim, Geum-Soo;Moon, Jong-Hyun;Cho, Hyun-Cheol;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.16-22
    • /
    • 2012
  • With the increase of consumption of new renewable energy, the use of Electric Double Layer Capacitor(EDLC) is being gradually widened as the next generation energy storage device. In order to expand the market of EDLC which is recently receiving a lot of attraction as a new promising area, development of a charge/discharge cycle tester to measure and test performance, is essential. Therefore, this research designed a circuit to measure capacity and internal resistance and a circuit to measure voltage maintenance properties, based on EDLC's basic charging/discharging properties so it is able to measure the state of charge and discharge at high speed. When evaluating performance characteristics, the 5[V]/100[A] prototype-EDLC charge/discharge testing system developed for this research showed ${\pm}0.1$[%] of accuracy of voltage and current measurement. It was also proved that the developed charge/discharge testing system for EDLC can be applied to the actual industry, when testing the entire system using a program produced for data monitoring and acquisition.

Design and Fabrication of an Ultra-low Partial Discharge Measurement System (극미소 부분방전 측정시스템의 설계 및 제작)

  • Seo, Hwang-Dong;Song, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kwon, Jang-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

Electrochemical Characteristics of Carbon/Carbon Hybrid Capacitor and Li-ion Battery/Hybrid Capacitor Combination (Carbon계 Hybrid Capacitor의 전기 화학적 기술 및 Li-ion Battery의 혼성 동력원 특성)

  • Lee, Sun-Young;Kim, Ick-Jun;Moon, Seong-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.597-598
    • /
    • 2005
  • Recently, the performance of portable electric equipment can often improved by a Li-ion battery assisted by a supercapacitor. A supercapacitor can provide high power density as well as a low resistance in the hybrid system. In this study, we have prepared, as the pluse power souce, a commercially supplied Li-ion battery with a capacity of 700mAh and AC resistivity of $60m\Omega$ at 1kHz and nonaqeous asymmetric hybrid capacitor composed of an activated carbon cathode and MCMB anode, and have examined the electrochemical characteristics of hybrid capacitor and the pulse performances of parallel connected battery/hybrid capacitor source. The nonaqueous asymmetric hybrid capacitor, the stacks of 10 pairs of the cathode, the porous separator and the anode electrode were housed in Al-laminated film cell. The hybrid capacitor, which was charged and discharged at a constant current at $0.25mA/cm^2$ between 3 and 4.3V, has exhibited the capacitance of 100F. And the equivalent series resistance was $32m\Omega$ at 1kHz. By combining a Li-ion battery and a hybrid capacitor, the pulse performance of battery can be improved 23% in run time under a pulse discharge of 7C-rate.

  • PDF

A Study on Improvement of Operation Characteristics and Inspection Method of Standby Power Supply such as Emergency Induction Light using Li-ion Capacitor (리튬이온커패시터를 활용한 비상유도등 예비전원장치의 동작 특성 및 점검방법 개선에 관한 연구)

  • Jung, Jun-Chea
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.392-401
    • /
    • 2020
  • Purpose: This study analyzes the operating characteristics of a lithium ion capacitor that can be used as a standby power supply in an emergency, and determines whether the standby power supply is abnormal even by measuring the voltage using a linear proportionality characteristic during charging and discharging. The aim is to provide an experimental basis that can be done. Method: As a method for this study, first, analyze the operation principle and characteristics of the existing backup power supply and lithium ion capacitor, and then measure the voltage of the lithium ion capacitor according to the configuration and system block diagram of the induction lamp used in the experiment. We proceed with the test of the measured value of discharge power for each voltage band to check the amount of power held by the battery and the operation test experiment using induction lamps. Results: Just by checking the charging voltage using the linear proportional characteristics of lithium ion capacitors, it provides a basis for accurately inferring the effective operating time of induction lamp lamps. Conclusion: In the event of a disaster, the lithium ion capacitor is used as a spare power supply for emergency induction lamps to prevent complete discharge of emergency induction lamps, to prevent the problem of performing normal operation of the standby power supply, and to use only a simple voltage measurement to reserve power. It was intended to suggest many uses for evacuation equipment application in the future by making it possible to check whether the device is abnormal.