• 제목/요약/키워드: Capacitor Quality

검색결과 196건 처리시간 0.029초

전기철도 급전시스템 전력품질 향상을 위한 새로운 보상장치 검토 (Analysis on New Equipment for countermeasure of Power Quality in Electric Railway)

  • 김주락;한문섭;이장무;정호성;김희중
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1396-1401
    • /
    • 2004
  • This paper proposes analysis on new equipment for power quality in electric railway. The Proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as de link. This structure can be compensated for active and reactive power in catenary through transformer.

  • PDF

슈퍼캐패시터와 가변속 엔진발전기를 이용한 독립형 전원 시스템 (An Isolated Power System Based on Variable Speed Engine Generator with Super-capacitor)

  • 이준환;이승환;설승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.15-17
    • /
    • 2007
  • The variable speed engine generator set is interested for an isolated power system due to reduced fuel consumption and less emission. However, because of sluggish dynamic behavior of the internal combustion engine the power quality would be degraded during the sudden load power surge, where the power required by the load is not available by the engine due to the reduced engine speed. An isolated power system based on variable speed engine with a super-capacitor bank improves dynamic characteristics under sudden load change, and power quality, fuel consumption, and pollutants can be reduced remarkably. Also, it is verified by the computer simulation that the inverter of 3phase-4leg is compatible to the isolated power system with unbalanced load. In this paper, the feasibility of the system has been verified based on a 26kw commercial diesel engine system.

  • PDF

Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1015-1024
    • /
    • 2015
  • This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.

유전상수 센서를 이용한 유압 작동유의 분석을 위한 실험장비 개발 (Development of Experimental Device for Analysis of Hydraulic Oil Characteristics with Dielectric Constant Sensors)

  • 홍성호
    • Tribology and Lubricants
    • /
    • 제37권2호
    • /
    • pp.41-47
    • /
    • 2021
  • An experimental device was developed for analysis of hydraulic oil characteristics with dielectric constant sensors. Online analysis is the most effective method of the three methods used for analyzing lubricant oils. This is because it can monitor the machine condition effectively using oil sensors in real time without requiring excellent analysis skill and eliminates human errors. Determining the oil quality usually requires complex laboratory equipment for measuring factors such as density, viscosity, base number, acid number, water content, additive, and wear debris. However, the electric constant is another indicator of oil quality that can be measured on-site. The electric constant is the ratio of the capacitance of a capacitor using that material as a dielectric, compared with a similar capacitor that has a vacuum as its dielectric. The electric constant affects the factors such as the base oil, additive, temperature, electric field frequency, water content, and contaminants. In this study, the tendency of the electric constant is investigated with a variation of temperature, water content, and dust weight. The experimental device can control working temperature and mix the contaminants with oil. A machine condition monitoring program developed to analyze hydraulic oil is described. This program provides graph and digital values with variation of time. Moreover, it includes an alarm system for when the oil condition is bad.

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.

Dual CDS를 수행하는 CMOS 단일 슬로프 ADC를 위한 개선된 잡음 및 지연시간을 가지는 비교기 설계 (Design of a Comparator with Improved Noise and Delay for a CMOS Single-Slope ADC with Dual CDS Scheme)

  • 장헌빈;천지민
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.465-471
    • /
    • 2023
  • 본 논문은 CMOS Image Sensor(CIS)에 사용되는 single-slope ADC(SS-ADC)의 노이즈와 출력의 지연을 개선한 비교기 구조를 제안한다. 노이즈와 출력의 지연 특성을 개선하기 위해 비교기의 첫 번째 단의 출력 노드와 두 번째 단의 출력 노드 사이에 커패시터를 삽입하여 miller effect를 이용한 비교기 구조를 설계하였다. 제안하는 비교기 구조는 작은 capacitor를 이용하여 노이즈와 출력의 지연 및 layout 면적을 개선하였다. Single slop ADC에서 사용되는 CDS 카운터는 T-filp flop과 bitwise inversion 회로를 사용하여 설계하였고 전력 소모와 속도가 개선되었다. 또한 single slop ADC는 analog correlated double sampling(CDS)와 digital CDS를 함께 동작하는 dual CDS를 수행한다. Dual CDS를 수행함으로써 fixed pattern noise(FPN), reset noise, ADC error를 줄여 이미지 품질이 향상된다. 제안하는 comparator 구조가 사용된 single-slope ADC는 0.18㎛ CMOS 공정으로 설계되었다.

세라믹 적층공정을 이용한 강압용 압전변압기의 제작 및 특성 (Fabrication and Properties of Piezoelectric Transformer for Step-Down Voltage using Ceramic Stack Process)

  • 이창배;윤중락
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.164-164
    • /
    • 2009
  • A multilayer piezoelectric transformer(MPT) for step-down voltage was made by ceramic stack process. And then, the characteristics of piezoelectric transformer, such as resonance frequency, matching impedance, electro-mechanical coupling coefficient, voltage gain, heat generation and efficiency, are analyzed. The piezoelectric transformer consists of a lead zirconate titanate ceramic with a high electromechanical quality factor. The piezoelectric transformer, with a multilayered construction in the thickness direction, was formed with dimensions 15mm long, 15mm wide and 5mm thick.

  • PDF

소결과정에 있어서 Bindex Burnout 온도 및 소결온도까지의 가열속도가 MLC의 전기적 특성에 미치는 영향 (The Effect of Binder Burnout Time and Heating Rate on the Electrical Properties of Multilayer Ceramic Capacitors)

  • 김호기;오창섭;김용혁
    • 한국세라믹학회지
    • /
    • 제24권3호
    • /
    • pp.207-214
    • /
    • 1987
  • This paper is to determine the effect of binder burnout time and heating rate on the electrical propertries of type II multilayer ceramic capacitors(MLC). The quality of multilayer ceramic capacitor depends suitable on the binder burnout time, which is determined for at least 24 hours in the PVB-binder system. It is suggested that theelectrical properties of multilayer ceramic capacitor is due to the control of heating rate, with the dipole moment density from grain size distributiion. Comparing the fast firing with slow, we observed a small but consistent improvement in the electrical properties.

  • PDF

다목적 유전자 알고리즘을 이용한 SVC와 외부 리액터/커패시터 뱅크의 헙조 제어 (Coordination of SVC and External Reactor/Capacitor Banks Using Multi-objective)

  • 박종영;이상호;박종근;손광명;이송근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.233-235
    • /
    • 2000
  • SVC(Static Var Compensator) is commonly installed with conventional mechanically switched existing reactor or capacitor banks for wide range voltage control. The frequencies of switching of external banks have a great impact on the quality of voltage, but is limited since the life time of the external banks depends severely on the number of switching. So it is a complete multi-objective nonlinear optimization problem with conflicting objectives. This paper presents a method to determine the optimal coordination of SVC and external banks using genetic algorithm based on the multi-objective criteria. Optimal dead band and delay time of external banks is sought for reliable and efficient operation

  • PDF

The characteristics of MIS BST thin film capacitor

  • Park, Chi-Sun;Kim, In-Ki
    • 한국결정성장학회지
    • /
    • 제11권1호
    • /
    • pp.38-42
    • /
    • 2001
  • Electric and dielectric(Ba,Sr)$TiO_3$[BST] thin films for emtal-Insulator-Semiconductor(MIS) capacitors have been studied. BST thin films wre deposted on p-Si(100) substrates bythe RF magnetron sputtering with tempratue range of 500~$600^{\circ}C$. The dielectric properties of MIS capacitors consisting of Al/BST/$SiO_2$/Si sandwich structure were evaluated ot redcue the leakage current density. The charge state densities of the MIS capacitors were determined by high frequency (1 MHz) C-V measurement. In order to reduce the leakage current in MIS capacitor, high quality $SiO_2$ layer was deposited on bare p-Si substrate. Depending on the oxygen pressure and substrate temperature both positive and negative polarities of effective oxide charge in the MIS capacitors were evaluated. It is considered that the density of electronic states, generated at the BST/$SiO_2$/p-Si interface due to the asymmetric structure within BST/$SiO_2$/Si structure, and the oxygen vacancy content has influence on the behavior of oxide charge.

  • PDF