• Title/Summary/Keyword: Capacitor Quality

Search Result 196, Processing Time 0.021 seconds

A Study on the Dynamic Voltage Restorer to Application Luminaire for Emergency Exit Sign Operation to the Energy Storage System (에너지 저장장치(ESS)의 비상 유도등 동작을 적용한 순간전압강하 보상장치에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Kim, Jin Sun
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.433-439
    • /
    • 2015
  • Recently, Interest in power the quality was increased because of increasing the use of sensitive load equipment into an electrical disturbance such as computer, Electricity, Electronics, Telecommunications and semiconductor device. In addition, To enhance power quality, the instantaneous voltage drop occurred in precision load equipment is a need for proper compensation. In order to solve the problem, The developed dynamic voltage restorer (DVR) using an electric double layer capacitor (EDLC) has been applied. In this paper, We will do study to apply hybrid capacitors that have high energy density to the same size compared to the EDLC to DVR. Also, As a emergency luminaires of emergency power supply that we can support more than 10 years of life was confirmed the applicability of hybrid capacitor.

High-Q Micromechanical Digital-to-Analog Variable Capacitors Using Parallel Digital Actuator Array (병렬 연결된 다수의 디지털 구동기를 이용한 High-Q 디지털-아날로그 가변 축전기)

  • Han, Won;Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.137-146
    • /
    • 2009
  • We present a micromechanical digital-to-analog (DA) variable capacitor using a parallel digital actuator array, capable of accomplishing high-Q tuning. The present DA variable capacitor uses a parallel interconnection of digital actuators, thus achieving a low resistive structure. Based on the criteria for capacitance range ($0.348{\sim}1.932$ pF) and the actuation voltage (25 V), the present parallel DA variable capacitor is estimated to have a quality factor 2.0 times higher than the previous serial-parallel DA variable capacitor. In the experimental study, the parallel DA variable capacitor changes the total capacitance from 2.268 to 3.973 pF (0.5 GHz), 2.384 to 4.197 pF (1.0 GHz), and 2.773 to 4.826 pF (2.5 GHz), thus achieving tuning ratios of 75.2%, 76.1%, and 74.0%, respectively. The capacitance precisions are measured to be $6.16{\pm}4.24$ fF (0.5 GHz), $7.42{\pm}5.48$ fF (1.0 GHz), and $9.56{\pm}5.63$ fF (2.5 GHz). The parallel DA variable capacitor shows the total resistance of $2.97{\pm}0.29\;{\Omega}$ (0.5 GHz), $3.01{\pm}0.42\;{\Omega}$ (1.0 GHz), and $4.32{\pm}0.66\;{\Omega}$ (2.5 GHz), resulting in high quality factors which are measured to be $33.7{\pm}7.8$ (0.5 GHz), $18.5{\pm}4.9$ (1.0 GHz), and $4.3{\pm}1.4$ (2.5 GHz) for large capacitance values ($2.268{\sim}4.826$ pF). We experimentally verify the high-Q tuning capability of the present parallel DA variable capacitor, while achieving high-precision capacitance adjustments.

The Characteristics of Asymmetric Hybrid Supercapacitor Cells and Modules for Power Quality Stabilization (전력품질 안정화용 비대칭 하이브리드 슈퍼커패시터 셀 및 모듈 특성)

  • Lee, Byung-Gwan;Maeng, Ju-Cheul;Lee, Joung-Kyu;Yoon, Jung-Rag
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.617-621
    • /
    • 2016
  • In addition to the energy storage facilities based on high power technologies, Electric double layer capacitors(EDLC) are today's candidate for power quality stabilization. However, its low energy density is often inhibiting factor for application of electric power industry. Hybrid supercapacitor is an promising energy storage device that positioned between conventional EDLC and Li-ion battery. This paper describes the preparation and characteristics of a hybrid supercapacitor and module for power quality stabilization. A cylindrical 3200F hybrid supercapacitor ($60{\times}74.5mm$) was assembled by using the $Li_4Ti_5O_{12}$ electrode as an anode and activated carbon as a cathode. It shows 2.5 times higher energy density than conventional EDLC with the same volume. In order to determine the characteristics of the hybrid supercapacitor Module for uninterruptible power supply (UPS), hybrid supercapacitor cells were connected in series with active balancing circuit. At even the high current density of 14A(10C), Module prepared by 18 cells showed the capacitance of 170F at 30~50V, suggesting the applicability for UPS.

Circuit design for wireless hearing aid telecoil electromagnetic noise cancellation (무선보청기 텔레코일의 전자계 잡음 소거를 위한 회로 설계)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.382-384
    • /
    • 2005
  • When a hearing aid' s user is listening through telephone or cellular phone, he/she usually suffers from severe electrical magnetic interference noise. It is because hearing aids amplify voice signal as well as background noise. A telecoil, an induction coil, is a possible solution for the problem. Because a telecoil has the characteristic of high pass filter, it has some problem of resulting increased high frequency noise. For solving this problem, we can use a capacitor connected with the telecoil in parallel. According to capacitance, receiving signal quality may change. In this paper, proper capacitor values for the best sound quality are investigated by experimental work.

  • PDF

Circuit design for wireless hearing aid telecoil electromagnetic noise cancellation (무선보청기 텔레코일의 전자계 잡음 소거를 위한 회로 설계)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.551-553
    • /
    • 2005
  • When a hearing aid' s user is listening through telephone or cellular phone, he/she usually suffers from severe electrical magnetic interference noise. It is because hearing aids amplify voice signal as well as background noise. A telecoil, an induction coil, is a possible solution for the problem. Because a telecoil has the characteristic of high pass filter, it has some problem of resulting increased high frequency noise. For solving this problem, we can use a capacitor connected with the telecoil in parallel. According to capacitance, receiving signal quality may change. In this paper, proper capacitor values for the best sound quality are investigated by experimental work.

  • PDF

A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters (소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법)

  • In, Hyo-Chul;Kim, Seok-Min;Park, Seong-Soo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

Stability Analysis and Improvement of the Capacitor Current Active Damping of the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1565-1577
    • /
    • 2016
  • For grid-connected LCL-filtered inverters, dual-loop current control with an inner-loop active damping (AD) based on capacitor current feedback is generally used for the sake of current quality. However, existing studies on capacitor current feedback AD with a control delay do not reveal the mathematical relation among the dual-loop stability, capacitor current feedback factor, delay time and LCL parameters. The robustness was not investigated through mathematical derivations. Thus, this paper aims to provide a systematic study of dual-loop current control in a digitally-controlled inverter. At first, the stable region of the inner-loop AD is derived. Then, the dual-loop stability and robustness are analyzed by mathematical derivations when the inner-loop AD is stable and unstable. Robust design principles for the inner-loop AD feedback factor and the outer-loop current controller are derived. Most importantly, ensuring the stability of the inner-loop AD is critical for achieving high robustness against a large grid impedance. Then, several improved approaches are proposed and synthesized. The limitations and benefits of all of the approaches are identified to help engineers apply capacitor current feedback AD in practice.

A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication (Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발)

  • Kim, Dong-Jun;Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

AlN Based RF MEMS Tunable Capacitor with Air-Suspended Electrode with Two Stages

  • Cheon, Seong J.;Jang, Woo J.;Park, Hyeon S.;Yoon, Min K.;Park, Jae Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • In this paper, a MEMS tunable capacitor was successfully designed and fabricated using an aluminum nitride film and a gold suspended membrane with two air gap structure for commercial RF applications. Unlike conventional two-parallel-plate tunable capacitors, the proposed tunable capacitor consists of one air suspended top electrode and two fixed bottom electrodes. One fixed and the top movable electrodes form a variable capacitor, while the other one provides necessary electrostatic actuation. The fabricated tunable capacitor exhibited a capacitance tuning range of 375% at 2 GHz, exceeding the theoretical limit of conventional two-parallel-plate tunable capacitors. In case of the contact state, the maximal quality factor was approximately 25 at 1.5 GHz. The developed fabrication process is also compatible with the existing standard IC (integrated circuit) technology, which makes it suitable for on chip intelligent transceivers and radios.

Development of On-Line Type Voltage Sag Compensation Systems by Using a Supercapacitor (수퍼커패시터를 이용한 상시가동형 순시전압강하 보상시스템의 개발)

  • Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • This paper deal with development of on-line type voltage sag compensation system using supercapacitor EDLC to solve the voltage sag problems which are considered to be dominant disturbances affecting the power quality. With the wide use of semiconductor devices in electrical equipment, modem-type loads are becoming increasingly sensitive to the voltage sags and the disturbances prove to be costly to industries. Supercapacitor EDLC is employed to compensate dynamically for the voltage sag of system with sensitive loads. This capacitor has higher energy density than the electrolytic capacitor. Also, this capacitor has a lot of advantage such as no maintenance, longer life cycle and faster charge-discharge time than the battery system. Therefore, in this paper, the energy design scheme of supercapacitor and the configuration technique of on-line type voltage sag compensation systems are newly introduced. According to the results of experimental of prototype 5[kVA] system, it is verified that the developed system has effectiveness of voltage sag compensation by using a supercapacitor EDLC.