• Title/Summary/Keyword: Capacitive type

Search Result 221, Processing Time 0.028 seconds

LED Driver with TRIAC Dimming Control by Variable Switched Capacitance for Power Regulation

  • Lee, Eun-Soo;Sohn, Yeung-Hoon;Nguyen, Duy Tan;Cheon, Jun-Pil;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.555-566
    • /
    • 2015
  • A TRIAC dimming LED driver that can control the brightness of LED arrays for a wide range of source voltage variations is proposed in this paper. Unlike conventional PWM LED drivers, the proposed LED driver adopts a TRIAC switch, which inherently guarantees zero current switching and has been proven to be quite reliable over its long lifetime. Unlike previous TRIAC type LED drivers, the proposed LED driver is composed of an LC input filter and a variable switched capacitance, which is modulated by the TRIAC turn-on timing. Thus, the LED power regulation and dimming control, which are done by a volume resistor in the same way as the conventional TRIAC dimmers, can be simultaneously performed by the TRIAC control circuit. Because the proposed LED driver has high efficiency and a long lifetime with a high power factor (PF) and low total harmonic distortion (THD) characteristics, it is quite adequate for industrial lighting applications such as streets, factories, parking garages, and emergency stairs. A simple step-down capacitive power supply circuit composed of passive components only is also proposed, which is quite useful for providing DC power from an AC source without a bulky and heavy transformer. A prototype 60 W LED driver was implemented by the proposed design procedure and verified by simulation and experimental results, where the efficiency, PF, and THD are 92%, 0.94, and 6.3%, respectively. The LED power variation is well mitigated to below ${\pm}2%$ for 190 V < $V_s$ < 250 V by using the proposed simple control circuit.

Development of Humidity Sensor Based on Ceramic/Metal Halide Composite Films for Non-Contact Biological Signal Monitoring Applications (비접촉 생체신호 모니터링 응용을 위한 세라믹/메탈 할라이드 복합막 기반 습도센서 개발)

  • Park, Tae-Ung;Kim, Ik-Soo;Kim, Min-Ji;Park, Chulhwan;Seo, Eui-kyoung;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.412-417
    • /
    • 2022
  • Capacitive-type humidity sensors with a high sensitivity and fast response/recovery times have attracted a great attention in non-contact respiration biological signal monitoring applications. However, complicated fabrication processes involving high-temperature heat treatment for the hygroscopic film is essential in the conventional ceramic-based humidity sensors. In this study, a non-toxic ceramic/metal halide (BaTiO3(BT)/NaCl) humidity sensor was prepared at room temperature using a solvent-free aerosol deposition process (AD) without any additional process. Currently prepared BT/NaCl humidity sensor shows an excellent sensitivity (245 pF/RH%) and superior response/recovery times (3s/4s) due to the NaCl ionization effect resulting in an immense interfacial polarization. Furthermore, the non-contact respiration signal variation using the BT/NaCl sensor was determined to be over 700% by maintaining the distance of 20 cm between the individual and the sensor. Through the AD-fabricated sensor in this study, we expect to develop a non-contact biological signal monitoring system that can be applied to various fields such as respiratory disease detection and management, infant respiratory signal observation, and touchless skin moisture sensing button.

Development of Flexure Applied Bond head for Die to Wafer Hybrid Bonding (Die to Wafer Hybrid Bonding을 위한 Flexure 적용 Bond head 개발)

  • Jang, Woo Je;Jeong, Yong Jin;Lee, Hakjun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.171-176
    • /
    • 2021
  • Die-to-wafer (D2W) hybrid bonding in the multilayer semiconductor manufacturing process is one of wafer direct bonding, and various studies are being conducted around the world. A noteworthy point in the current die-to-wafer process is that a lot of voids occur on the bonding surface of the die during bonding. In this study, as a suggested method for removing voids generated during the D2W hybrid bonding process, a flexible mechanism for implementing convex for die bonding to be applied to the bond head is proposed. In addition, modeling of flexible mechanisms, analysis/design/control/evaluation of static/dynamics properties are performed. The proposed system was controlled by capacitive sensor (lion precision, CPL 290), piezo actuator (P-888,91), and dSpace. This flexure mechanism implemented a working range of 200 ㎛, resolution(3σ) of 7.276nm, Inposition(3σ) of 3.503nm, settling time(2%) of 500.133ms by applying a reverse bridge type mechanism and leaf spring guide, and at the same time realized a maximum step difference of 6 ㎛ between die edge and center. The results of this study are applied to the D2W hybrid bonding process and are expected to bring about an effect of increasing semiconductor yield through void removal. In addition, it is expected that it can be utilized as a system that meets the convex variable amount required for each device by adjusting the elongation amount of the piezo actuator coupled to the flexible mechanism in a precise unit.

Corrosion Inhibition Performance of Two Ketene Dithioacetal Derivatives for Stainless Steel in Hydrochloric Acid Solution

  • Lemallem, Salah Eddine;Fiala, Abdelali;Ladouani, Hayet Brahim;Allal, Hamza
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.237-253
    • /
    • 2022
  • The methyl 2-(1,3-dithietan -2- ylidene)-3-oxobutanoate (MDYO) and 2-(1,3-dithietan-2-ylidene) cyclohexane -1,3-dione (DYCD) were synthesized and tested at various concentrations as corrosion inhibitors for 316L stainless steel in 1 M HCl using weight loss, electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PDP), surface analysis techniques (SEM / EDX and Raman spectroscopy) and Functional Density Theory (DFT) was also used to calculate quantum parameters. The obtained results indicated that the inhibition efficiency of MDYO and DYCD increases with their concentration, and the highest value of corrosion inhibition efficiency was determined in the range of concentrations investigated (0.01 × 10-3 - 10-3 M). Polarization curves (Tafel extrapolation) showed that both compounds act as mixed-type inhibitors in 1M HCl solutions. Electrochemical impedance spectra (Nyquist plots) are characterized by a capacitive loop observed at high frequencies, and another small inductive loop near low frequencies. The thermodynamic data of adsorption of the two compounds on the stainless steel surface and the activation energies were determined and then discussed. Analysis of experimental results shows that MDYO and DYCD inhibitors adsorb to the metal surface according to the Langmuir model and the mechanism of adsorption of both inhibitors involves physisorption. SEM-EDX results confirm the existence of an inhibitor protective film on the stainless steel surface. The results derived from theoretical calculations supported the experimental observation.

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.

Wideband Colpitts Voltage Controlled Oscillator with Nanosecond Startup Time and 28 % Tuning Bandwidth for Bubble-Type Motion Detector (나노초의 발진 기동 시간과 28 %의 튜닝 대역폭을 가지는 버블형 동작감지기용 광대역 콜피츠 전압제어발진기)

  • Shin, Im-Hyu;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1104-1112
    • /
    • 2013
  • This paper presents a wideband Colpitts voltage controlled oscillator(VCO) with nanosecond startup time and a center frequency of 8.35 GHz for a new bubble-type motion detector that has a bubble-layer detection zone at the specific distance from itself. The VCO circuit consists of two parts; one is a negative resistance part with a HEMT device and Colpitts feedback structure and the other is a resonator part with a varactor diode and shorted shunt microstrip line. The shorted shunt microstrip line and series capacitor are utilized to compensate for the input reactance of the packaged HEMT that changes from capacitive values to inductive values at 8.1 GHz due to parasitic package inductance. By tuning the feedback capacitors which determine negative resistance values, this paper also investigates startup time improvement with the negative resistance variation and tuning bandwidth improvement with the reactance slope variation of the negative resistance part. The VCO measurement shows the tuning bandwidth of 2.3 GHz(28 %), the output power of 4.1~7.5 dBm and the startup time of less than 2 nsec.

Therapeutic Effect of Combined Radiotherapy and Hyperthermia in Primary Hepatocellular Carcinoma (원발성 간암의 방사선치료및 온열요법의 병용치료 효과)

  • Kang Ki Mun;Choi Ihl Bohng;Kay Chul Seung;Choi Byung Ok;Chung Su Mi;Kim In Ah;Han Sung Tae;Sun Hee Sik;Chung Kyu Won;Shinn Keyong Sub
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.191-199
    • /
    • 1994
  • Purpose : This study was undertaken to show the clinical results of combined radiotherapy and hyperthermia in primary hepatoma Materials and Methods : Between December 1989 and March 1993, 50 patients with hepatomas were treated by combined radiotherapy and hyperthermia. Among them, we analyzed retrospectively 33 patients who received the complete course of treatment. The ages of the patients ranged from 36 to 75(mean age: 55.5 years). Twenty-six patients ($78.8\%$) were men, and 7 ($21.2\%$ were women. According to Child's classification, nine patients ($27.3{\%}$) were A group, 9 ($27.3\%$) were B group, 15 ($45.4\%$) were C group. Radiation therapy was done by a 6 MV and 15 MV linear accelerator. Patients were treated with daily fractions of 150-180 cCy to doses of 2550 cGy -4950 cGy (median : 3000 cGy). Local hyperthermia was done by 8 MHZ RF capacitive heating device (Cancermia. Green Cross Co., Korea), 50-60 min/session, 1-2 sessions/wk, and 8.5 sessions (median number)/patient. We analyzed the prognostic factors including age, sex, tumor type, Child's classification, $\alpha$-fetoprotein, liver cirrhosis, ascites, portal vein invasion, esophageal varix, number of hyperthermia, chemotherapy, total bilirubin level, Karnofsky perfomance status. Results : The overall 1-year survival was $24.2\%$, with a mean survival of 10months. Of 33 patients, tumor regression (PR+MR) was seen in $30.4\%$, no response was seen in $52.2\%,\;17.4\%$ patient was progressed. In patients who had tumor regression, the overall 1-year survival was $42.1\%$ with a mean survival of 14 months. Factors influencing the survival were sex (p=0.05), tumor type (p=0.0248), Child's classification (p=0.0001), liver cirrhosis (p=0.0108), ascites (p=0.0009), and Karnofsky perfomance status (p=0.0028). Complications developed in 28 patients, including 18 hot pain,5 fat necrosis, 3 transient fever, 2 nausea and vomiting. Conclusion : In this study, the results suggests that combined radiotherauy and hyperthermia may improve the survival rate of hepatoma.

  • PDF

High crystallization of ultra-thin indium tin oxide films prepared by reactive sputtering with post-annealing (반응성 스퍼터링으로 제조한 ITO 초박막의 후 열처리에 따른 고 결정화)

  • Lee, Ho-Yun;Kim, Seo-Han;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.128-128
    • /
    • 2018
  • 최근 디스플레이 기술은 보다 가볍고, 얇고, 선명한 스마트 형태로 발전되고 있다. 특히 스마트산업의 성장으로 터치스크린패널(Touch Screen Panel, TSP)을 사용하는 기술이 다양해짐에 따라 더 높은 감도와 해상도를 달성하기 위한 핵심기술이 필요한 실정이다. TSP는 저항막 방식, 정전용량 방식, 적외선 방식, 초음파 방식 등 다양한 방식이 있다. 그 중 정전용량방식 터치 패널 (Capacitive type touch panel, CTTP)은 다른 유형에 비해 빠른 반응속도 및 멀티 터치 기능 등의 이점을 가지고 있기 때문에 연구의 초점이 되고 있다. 이를 실현하기 위해서 CTTP은 가시광영역의 높은 투과율과 낮은 비저항을 필요로 하기 때문에 박막의 초 슬림화 및 고 결정화도가 선행되어야만 한다. CTTP에 사용되는 투명전극 소재 중에서 40%의 비중을 차지하고 있는 ITO박막은 내구성과 시인성이 좋으나 생산 비용이 비싸다는 단점이 있다. 한편, 반응성 스퍼터링은 기존에 단일 소결체를 사용한 DC마그네트론 스퍼터링법보다 높은 증착률과 낮은 생산 비용으로 초박막을 만들 수 있다는 장점을 가진다. 본 실험에서는 In/Sn (2wt%) 금속 합금 타깃을 사용한 반응성 스퍼터링법을 이용하여 기판 온도 (RT 및 $140^{\circ}C$)에서 두께 30 nm의 In-Sn-O (ITO)박막을 증착하고, 대기 중 $140^{\circ}C$ 온도에서 시간에 따라 열처리한 후 박막의 물성을 관찰하였다. 증착 중 기판 가열을 하지 않은 ITO 박막의 경우, 열처리 시간이 증가함에 따라 비저항은 감소하였고, 홀 이동도는 현저하게 증가하였으며 캐리어 밀도에서는 별다른 차이가 없었다. 이를 통해 비저항의 감소는 캐리어 농도보다는 결정화를 통한 이동도의 증가와 관련 있다는 것을 확인할 수 있었다. 열처리 시간에 따른 박막의 핵 생성 및 결정 성장은 투과 전자 현미경(TEM)으로 명확하게 확인하였으며, 완전 결정화 된 박막의 grain size는 300~500 nm로 확인되었다. 기판온도 $140^{\circ}C$에서 증착한 박막의 경우, 후 열처리를 하지 않은 상태에서도 이미 결정화 된 것을 확인할 수 있었으며, 후 열처리 시에도 grain size에는 큰 변화가 없었다. 이는 증착 중에 박막의 결정화가 이미 완결된 것으로 판단된다. 또한, RT에서 증착한 박막의 경우에는 후 열처리 초기에는 산소공공등과 같은 결함들의 농도가 감소하여 투과율이 증가하였으나 완전한 결정화가 일어난 후에는 투과율이 약간 감소한 것을 확인할 수 있었다. 이는 결정화 시 박막의 표면 조도가 증가하였고 이로 인해 빛의 산란이 증가하여 투과율이 감소한 것으로 판단된다. 이러한 결과로 반응성 스퍼터링 공정으로 제조한 ITO 초박막은 후열처리에 의한 완전한 결정화를 이룰 수 있으며, 이를 통해 얻은 낮은 비저항과 높은 투과율은 고품질 TSP에 적용될 가능성을 가진다고 판단된다.

  • PDF

Porous silicon : a new material for microsensors and microactuators (다공질 실리콘: 새로운 마이크로센서 및 마이크로액추에이터 재료)

  • Min Nam Ki;Chi Woo Lee;Jeong Woo Sik;Kim Dong Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • Since the use of porous silicon for microsensors and microactuators is in the euly stage of study, only several application devices, such as light-emitting diodes and chemical sensors have so far been demonstrated. In this paper we present an overview of the present status of porous silicon sensors and actuators research with special emphasis on the applications of chemical sensors and optical devices. The capacitive type porous silicon humidity sensors had a nonlinear capacitance-humidity characteristic and a good sensitivity at higher humidity above $40\%RH$. The porous silicon $n^+-p-n^+$ device showed a sharp increase in current when exposed to an ethanol vapor. The $p^+-PSi-n^+$ diode fabricated on porous silicon diaphragm exhibited an optical switching characteristic, opening up its utility as an optical sensor or switch. The photoluminescence (PL) spectrum, taken from porous silicon under 365 nm excitation, had a broad emission, peaked at -610 nm. The electroluminescence(EL) from ITO/PSi/In LED had a broader spectrum with a blue shifted peak at around 535nm than that of the PL.

Combined Radiotherapy and Hyperthermia for Nonresectable Hepatocellular Carcinoma (절제 불가능한 원발성 간암의 온열 및 방사선 병용 요법)

  • Seong Jin Sil;Juhn Juhn Kyu;Suh Chang Ok;Kim Gwi Eon;Han Kwang Hyub;Lee Sang In;Roh Jae Kyung;Choi Heung Jai;Kim Byung Soo
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.247-257
    • /
    • 1989
  • Thirty patients with nonresectable hepatocellular carcinoma (HCC) due to either locally advanced lesion or association with liver cirrhosis, treated with combined radiotherapy and hyperthermia between April 1988 and July 1988, at Dept. of Radiation Oncology, Yonsei university College of medicine, were analysed. External radiotherapy of a total dose of 3060cGy/3.5 wks was given. Hyperthermia was given twice a week with a total of 6 treatment sessions using 8MHz radiofrequency capacitive type heating device, i.e., Thermotron RF-8 and Cancermia. In all cases hyperthermia was given within 30 minutes after radiotherapy for 30~60min. Temperature was measured by inserting thermocouple into the tumor mass under the ultrasonographic guidance only for those who had not bleeding tendency. As a result, partial response (PR) was achieved in 12 patients (40%), and symptomatic improvement was observed in 22 patients (78.6%) among 28 patients who had suffered from abdominal pain. The most significant factor affecting the tumor response rate was the type of tumor (single massive: 10/14, 71.4%; diffuse infiltrative: 2/10, 20%; multinodular:0/6, 0%; p<0.005). There were not any significant side effects relating to combined treatment. The overall 1 year survival rate was 34%, with 50% in the PR group and 22% in the no response group (NR), respectively. Median survival was 6.5 months and longer for those of PR than of NR (11 mos. vs 5, p<0.05). In conclusion, combined radiotherapy and hyperthermia appeared to be effective in local control and symptomatic palliation of HCC. Further study including a larger number of the patients to confirm its effect in survival and detrimental side effect should be urged.

  • PDF