• 제목/요약/키워드: Capacitive type

검색결과 221건 처리시간 0.023초

평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발 (Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor)

  • 강전홍;류제천;이상화;김규태;김명수;한상옥;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권9호
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

Classification and Analysis of Switched Reluctance Converters

  • Ahn, Jin-Woo;Liang, Jianing;Lee, Dong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.571-579
    • /
    • 2010
  • This paper reviews and analyzes converters for SRM(Switched Reluctance Motor) drive. Conventional classification focuses on the number of power switches and diodes. It is easy to find the number of semiconductors and the cost by counting the number of active components, but it does not show the important characteristics of a power converter. The voltage ratings for the power switches and diodes are also difficult to identify. This paper proposes a switched reluctance (SR) converter configuration that is classified based on the commutation type and magnetic energy path. The converter has three parts: utility interface, front-end circuit, and power converter. Based on the overview on the conventional SR drive, the most important characteristic of the converter is determined by the topology of front-end in conjunction with the power converter. An SR converter has two parts: front-end and power converter. Inasmuch as the capacitive front-end is widely used for voltage source converters, this paper focuses on topologies for the front-end.

디지털신호처리기법을 이용한 중금속이온농도 결정의 SWSV 신호분석 (The SWSV signal analysis for decision of heavy metal ion concentration using digital signal processing method)

  • 이재춘
    • 디지털산업정보학회논문지
    • /
    • 제5권4호
    • /
    • pp.11-17
    • /
    • 2009
  • Polarography is a subclass of voltammetry where the working electrode is a dropping mercury electrode. More, I developed the experiment for raising up mercury electrode. In Voltammetry, information about an analyte is obtained by measuring the current as the potential is varied at oxidation-reduction reaction. A plot of current vs. potential in a polarography experiment shows the current oscillations correspoding to the drops of Hg falling from the capillary. The drops growth causes capacitive and faradic current. These changing current effects combined with experiments where the potential is continuously changed can result in noisy traces. The raising up type improved upon the method of dropping in hardware. In reduction of the noise, moving average smoothing method have been used. But the other procedure is introduced based on Fourier transformation. So FFT and IFFT engine was implemented and installed in my experiment. However, after experimentation, peak height as the measuring parameter gave a good linear relationship to concentration. The resolution of potential peaks of various kinds, using Zn and Cu as the example, was improved using the smoothing method.

포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발 (Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell)

  • 홍진영;이정헌;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

초기 비결합된 수직빗살 전극형 정전 스캐너의 거동제어 (Feedback control for initially unengaged vertical comb type electrostatic scanner)

  • 이병렬;원종화;조진우;정희문;조용철;이진호;고영철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.845-846
    • /
    • 2006
  • In this paper, we describe a capacitive position sensing and motion control scheme of a MEMS scanner used for laser display application. The laser displays can be made by scanning laser beams much the same way a CRT scans electron beams. So the accuracy of the scanner motion determines the quality of the displayed image. The MEMS scanner under consideration is composed of electrostatic comb electrodes with initial gap and requires large driving voltage. Due to the under-damping and nonlinear driving characteristics, the scanner motion is subject to be an unwanted oscillation. For the linear scanner motion, we devise a differential charge amplifier and phase compensator. The experimental results show that the implemented feedback control system provides sufficient electrical damping and improves the dynamic performance of the scanner.

  • PDF

The Micro Pirani Gauge with Low Noise CDS-CTIA for In-Situ Vacuum Monitoring

  • Kim, Gyungtae;Seok, Changho;Kim, Taehyun;Park, Jae Hong;Kim, Heeyeoun;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권6호
    • /
    • pp.733-740
    • /
    • 2014
  • A resistive micro Pirani gauge using amorphous silicon (a-Si) thin membrane is proposed. The proposed Pirani gauge can be easily integrated with the other process-compatible membrane-type sensors, and can be applicable for in-situ vacuum monitoring inside the vacuum package without an additional process. The vacuum level is measured by the resistance changes of the membrane using the low noise correlated double sampling (CDS) capacitive trans-impedance amplifier (CTIA). The measured vacuum range of the Pirani gauge is 0.1 to 10 Torr. The sensitivity and non-linearity are measured to be 78 mV / Torr and 0.5% in the pressure range of 0.1 to 10 Torr. The output noise level is measured to be $268{\mu}V_{rms}$ in 0.5 Hz to 50 Hz, which is 41.2% smaller than conventional CTIA.

An MMIC VCO Design and Fabrication for PCS Applications

  • Kim, Young-Gi;Park, Jin-Ho
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.202-207
    • /
    • 1997
  • Design and fabrication issues for an L-band GaAs Monolithic Microwave Integrated Circuit(MMIC) Voltage Controlled Oscillator(VCO) as a component of Personal Communications Systems(PCS) Radio Frequency(RF) transceiver are discussed. An ion-implanted GaAs MESFET tailored toward low current and low noise with 0.5mm gate length and 300mm gate width has been used as an active device, while an FET with the drain shorted to the source has been used as the voltage variable capacitor. The principal design was based on a self-biased FET with capacitive feedback. A tuning range of 140MHz and 58MHz has been obtained by 3V change for a 600mm and a 300mm devices, respectively. The oscillator output power was 6.5dBm wth 14mA DC current supply at 3.6V. The phase noise without any buffer or PLL was 93dB/1Hz at 100KHz offset. Harmonic balance analysis was used for the non-linear simulation after a linear simulation. All layout induced parasitics were incorporated into the simulation with EEFET2 non-linear FET model. The fabricated circuits were measured using a coplanar-type probe for bare chips and test jigs with ceramic packages.

  • PDF

Ginger Extract as Green Corrosion Inhibitor for Steel in Sulfide Polluted Salt Water

  • Fouda, Abd El-Aziz S.;Nazeer, Ahmed Abdel;Ibrahim, Mohamed;Fakih, Mohamed
    • 대한화학회지
    • /
    • 제57권2호
    • /
    • pp.272-278
    • /
    • 2013
  • Extract of ginger has been evaluated as a green inhibitor for the corrosion of steel in sulfide polluted NaCl solution using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and electrochemical frequency modulation (EFM) techniques. Potentiodynamic polarization measurements showed that this extract acts as a mixed type inhibitor but mainly inhibits the cathodic reaction. The inhibition efficiency was found to increase with inhibitor concentration reaching to approximately 83.9% using 250 ppm of ginger. Nyquist plots show a single capacitive loop in uninhibited and inhibited solutions. From EFM the causality factors are very close to theoretical values which indicate that the measured data are of good quality. The adsorption process of the studied extract on steel surface obeys Temkin adsorption isotherm. The results obtained from the different electrochemical techniques were in good agreement which prove the validity of these tools in measurement of corrosion rate. Ginger extract has no effect on Escherichia Coli and can be applied safely on waste water treatment plants.

A Novel Soft-Switching PWM DC/DC Converter with DC Rail Series Switch-Parallel Capacitor Edge Resonant Snubber Assisted by High-Frequency Transformer Parasitic Components

  • ;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.377-382
    • /
    • 2005
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. One topology of proposed DC-DC converters is composed of a typical voltage source-fed full-bridge high frequency PWM inverter using DC busline side series power semiconductor switching devices with the aid of a parallel capacitive lossless snubber. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. It is proved that the more the switching frequency of full-bridge soft switching inverter increases, the more soft-switching PWM DC-DC converter with a hish frequency transformer link has remarkable advantages for its efficiency and power density as compared with the conventional hard-switching PWM inverter type DC-DC converter

  • PDF

Nano and micro structures for label-free detection of biomolecules

  • Eom, Kil-Ho;Kwon, Tae-Yun;Sohn, Young-Soo
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.403-420
    • /
    • 2010
  • Nano and micro structure-based biosensors are promising tool for label-free detection of biomolecular interactions with great accuracy. This review gives a brief survey on nano and micro platforms to sense a variety of analytes such as DNA, proteins and viruses. Among incredible nano and micro structure for bio-analytical applications, the scope of this paper will be limited to micro and nano resonators and nanowire field-effect transistors. Nanomechanical motion of the resonators transducers biological information to readable signals. They are commonly combined with an optical, capacitive or piezo-resistive detection systems. Binding of target molecule to the modified surface of nanowire modulates the current of the nanowire through electrical field-effect. Both detection methods have advantages of label-free, real-time and high sensitive detection. These structures can be extended to fabricate array-type sensors for multiplexed detection and high-throughput analysis. The biosensors based on these structures will be applied to lab-on-a-chip platforms and point-of-care diagnostics. Basic concepts including detection mechanisms and trends in their fields will be covered in this review.