• Title/Summary/Keyword: Capacitance aging

Search Result 39, Processing Time 0.02 seconds

A Study on the Complex Accelerating Degradation and Condition Diagnosis of Traction Motor for Electric Railway (전기철도용 견인전동기의 복합가속열화 상태진단에 관한 연구)

  • 왕종배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.93-101
    • /
    • 2002
  • In this study, the stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the C-Class(200$\^{C}$ ) insulation system of traction motors. The complex accelerative degradation was periodically performed during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, the condition diagnosis test such as insulation resistance '||'&'||' polarization index, capacitance '||'&'||' dielectric loss and partial discharge properties were investigated in the temperature range of 20 ∼ 160$\^{C}$. Relationship among condition diagnosis tests was analyzed to find a dominative degradation factor and an insulation state at end-life point.

A Simple ESR Measurement Method for DC Bus Capacitor Using DC/DC Converter (DC/DC 컨버터를 이용한 DC Bus 커패시터의 간단한 ESR 측정 기법)

  • Shon, Jin-Geun;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.372-376
    • /
    • 2010
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. The estimation of the equivalent series resistance(ESR) is important parameter in life condition monitoring of electrolytic capacitor. This paper proposes a simple technique to measure the ESR of an electrolytic capacitor. This method uses a switching DC/DC boost converter to measure the DC Bus capacitor ESR of power converter. Main advantage of the proposed method is very simple in technique, consumes very little time and requires only simple instruments. Simulation results are shown to verify the performance of the proposed method.

Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis (견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가)

  • 왕종배;김명룡
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF

Non-Contact Ultrasonic Testing of Aircraft Joints using Laser Generated Lamb Wave (레이저 여기 램파를 이용한 항공기 판재 접합부의 비접촉식 초음파 검사)

  • Jhang, Kyoung-Young;Kim, Hong-Joon;Ceringlia, Donatella;Djordjevic, Boro
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.163-168
    • /
    • 2001
  • Due to aging, adhesively bonded and riveted aircraft lap joints can contain distends, cracks around rivet holes, fatigue induced flaws, and corrosion. It is required for the safety of aircraft to inspect these defects through the whole region of mint in rapid speed. Bond quality or adhesively bonded and riveted aluminum lap splice joints is investigated using non-contact remote ultrasonic nondestructive evaluation (NDE). Non-contact ultrasonic tests are performed using laser generation and air-coupled transducer detection. A Q-switched Nd:YAG laser and a periodic transmission mask are used to generate a selected Lamb mode. The Lamb wave is generated on one side of the lap splice joint, propagates along the plate, interacts with the joint and is detected on the other side by a micromachined air-coupled capacitance transducer. Analysis of recorded signals allows to evaluate the condition of the bond.

  • PDF

Analysis of Insulation Quality in Large Generator Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho;Kim, Byong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.384-390
    • /
    • 2011
  • To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.

Evaluation about Dielectric Property of Heat Transfer Fluids for Fuel Cell Vehicle using Cylindrical Multi-Terminal Capacitive-Conductive Sensor (원통형 다전극식 정전용량-전기전도도 센서를 이용한 연료전지 차량용 냉각수의 유전특성 평가)

  • Kim, Jae-Hoon;Kim, Ju-Han;Kim, Yoon-Hyung;Choi, Kang-Wal;Han, Sang-Ok;Yong, Gee-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1087-1094
    • /
    • 2010
  • We have developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid. It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Also to assess diagnosis characteristics of heat transfer fluid, i.e. coolant, we have performed accelerated aging test using developed sensor attached to cooling system. Consequently, it was measured dielectric and electric resistance of coolant to estimate and analyse for dielectric properties by degradation condition.

A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication (Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발)

  • Kim, Dong-Jun;Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

A Plan to Ensure Safety of Electric Installation in Empty houses During Normal Working Hours (부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, In-Soo;Bae, Seok-Myung;Cho, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.25-26
    • /
    • 2006
  • An electrical fault is defined as any abnormal condition caused by reduction in the insulation strength between energized conduction parts and ground or any grounded part of an electrical system. Failure of solid insulation can be caused by excessive mechanical tension being applied on the insulation, harsh service environment, aging, and also by corona phenomena. The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installation for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF

Analysis of the Effect of Alternating Current Ripple on Electrical State of Health Degradation of 21700 Lithium-ion Battery (교류 리플이 21700 리튬 이온 배터리의 전기적 건강 상태 열화에 미치는 영향 분석)

  • Bongwoo Kwak
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.477-485
    • /
    • 2023
  • In this paper, the effect of AC ripple on the lifetime of lithium-ion batteries is experimentally analyzed. Bidirectional power conversion system(PCS) is used to increase the efficiency of energy storage systems (ESS). When connected to the grid, a current ripple with a frequency twice the grid frequency is applied to the battery due to its structure. Therefore, to analyze the effect of AC ripple on Li-ion battery aging, cycle life test are performed by applying charge/discharge profiles of DC current and DC+AC current ripple specifications. Based on the experimental results, direct current internal resistance (DCIR), incremental capacitance (IC), and surface temperature were analyzed. As a result, it is confirmed that AC ripple does not directly affect degradation and that battery degradation slows down after a certain cycle. These results can serve as a guideline for optimizing filters to reduce ripple on the battery side in applications where AC ripple occurs.