• Title/Summary/Keyword: Cancer detection

Search Result 1,520, Processing Time 0.028 seconds

Immunohistochemical Detection of Lymph Nodes Micrometastases in Patients of Pathologic Stage I Non-small-cell Lung Cancer (병리적 병기 1기의 비소세포폐암 환자에서 면역조직화학염색에 의한 림프절 미세전이 관찰)

  • Ryu, Jeong-Seon;Han, Hye-Seung;Kim, Min-Ji;Kwak, Seung-Min;Cho, Jae-Hwa;Yoon, Yong-Han;Lee, Hong-Lyeol;Chu, Young-Chae;Kim, Kwang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.345-350
    • /
    • 2004
  • Background : To evaluate the frequency and clinical significance of lymph node micrometastasis in patients of non-small-cell lung cancer pathologically staged to be T1-2,N0. Method : From consecutive 29 patients of non-small-cell lung cancer who received curative operation and routine systemic nodal dissection, we immunohistochemically examined 806 lymph nodes from mediastinal, hilar and peribronchial lesion. All slides were stained with hematoxylin and eosin staining for one section and with cytokeratin AE1/AE3 antibody for another consecutive section of same lymph node to find out micrometastasis. Results : In 806 lymph nodes examined, no tumor cell was seen on hematoxylin and eosin staining and micrometastic foci were shown to be on 0.37%(3) of 806 lymph nodes, in which were upper paratracheal, interlobar and peribronchial lymph node. These three positive stains constitute 10.3%(3) of the 29 patients with non-small-cell lung cancer. Nine patients died from disease progression(4), postoperative complication(3) and concomitant diseases(2). The four patients with disease progression did not show evidence of micrometastasis on their lymph node examination. Conclusion : The frequency of lymph node micrometastasis was in 0.37% of 806 lymph nodes examined. The study results might suggested that routine analysis of micrometastasis on the lymph node didn't give any clinical implication on patients with non-small-cell lung cancer.

A Study on Need Assessment in Health Promotion Programs for Developing Nursing Centers - Breast Self Examination- (간호센타 개발을 위한 건강증진 프로그램 요구사정 연구-유방자가검진 프로그램을 중심으로-)

  • Park, In-Hyae;Kang, Hae-Young;Lee, Jeong-Hee;Ryu, Hyun-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.21-36
    • /
    • 2000
  • The purpose of this study was to assess the needs of breast self examination education (BSEE) programs for developing nursing centers. A first, we reviewed the literature of activity and management-related factors of nursing centers: and, second. we used a questionnaire to discover the degree of knowledge, attitude, and practice on breast cancer, as well as an individual's intention to participate BSEE program. 1. Reviewing the literatures of nursing center activities. Nursing centers which were administered by a professional nurse are an ideal site for faculty and student practices. With the use of nursing models of health. professional nurses in nursing centers diagnose and treat human responses to potential and actual health problems and offer holistic, client-centered health service. In nursing centers professional nursing services include health education, health promotion, and health-related research. A nursing center is comprised of the advisory and exacutive commitee; the advisory commitee serves consultants and links community needs to the nursing center, while the director of the exacutive commitee identifies the potential resources to generate funds, support, and facilitate the activities of staffs in a nursing center. Nursing centers mobilize various financal resources for reimbursement of services from college and insurance companies, collect minimum service fees from the client, and further collect fees for providing programs to community groups, this also includes membership fees, and donations. The services provided by nursing centers focus on services related to primary prevention, health maintenance & health promotion, direct nursing care for acute & chronic diseases, and holistic care for actual and potential health problems. The client satisfaction for the services was high. Students also showed positive reponses for their clinical experiences and independent working conditions. 2. The degree of knowledge, attitudes, and practices for breast cancer. and an individual's intention to participate in the BSEE program. The subjects of this study were 308 females in K-city in the Republic of Korea. Data were collected using a self-administered questionnaire. The mean age of the respondents was 35.0 years old. Those who already participated in the BSEE were 64.9%, and those who had support and encouragement to practice BSE from significant others were 25.1 %. Clients intent to participate in the BSEE were 37.0%. The mean score of knowledge(2.4 out of 5 points) and practices(1.8 out of 5 points) for breast cancer were quite low, but the mean score of attitudes was relatively positive04.5 out of 20 point) for breast cancer. Those who already had BSEE showed significantly high scores in knowledge(t=6.48, p<0.01), attitudes (t=10.54, p<0.01). and practices(t=57.07, p<0.001) for breast cancer than those who had not participated in the BSEE. In all age groups no intention to participate in the BSEE was higher than who the intention to participate. These findings suggest some strategies should be developed to increase the awareness of breast cancer's early detection.

  • PDF

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

A Comparison of Conventional Cytology and ThinPrep Cytology of Bronchial Washing Fluid in the Diagnosis of Lung Cancer (폐암의 진단 검사 중 기관지 세척액에서 ThinPrep검사법과 기존의 세포검사법의 유용성에 대한 비교)

  • Kim, Sang-Hoon;Kim, Eun Kyung;Shi, Kyeh-Dong;Kim, Jung-Hyun;Kim, Kyung Soo;Yoo, Jeong-Hwan;Kim, Joo-Young;Kim, Gwang-Il;Ahn, Hee-Jung;Lee, Ji-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.523-530
    • /
    • 2007
  • Background: A ThinPrep$^{(R)}$ Processor was developed to overcome the limitations of conventional cytology and is widely used to diagnose various cancers. This study compared the diagnostic efficacy of conventional cytology for lung cancer with that of the ThinPrep$^{(R)}$ cytology using the bronchial washing fluid. Methods: The bronchial washing fluid of 790 patients from Jan. 2002 to Dec. 2006, who were suspected of gaving a lung malignancy, was evaluated. Both ThinPrep$^{(R)}$ and conventional cytology were performed for all specimens. Result: Four hundred forty-six men and 344 women were enrolled in this study, and 197 of them were diagnosed with cancer from either a bronchoscopic biopsy or a percutaneous needle aspiration biopsy. ThinPrep$^{(R)}$ cytology showed a sensitivity, specificity, positive predictive value, negative predictive value and false negative error rate of 71.1%, 98.0%, 92.1%, 91.1%, 8.9%, respectively. The conventional cytology showed sensitivity, specificity, positive predictive value, nagative predictive value and false negative error rate of 57.9%, 98.0%, 90.5%, 87.5%, 12.5%, respectively. For central lesions, the sensitivity of conventional cytology and ThinPrep$^{(R)}$ were 70.1% and 82.8%, respectively. Conclusion: ThinPrep$^{(R)}$ cytology showed a higher sensitivity and lower false negative error rate than conventional cytology. This result was unaffected by the histological classification of lung cancer. Therefore, ThinPrep$^{(R)}$ cytology appears to be a useful method for increasing the detection rate of lung cancer in bronchial washing cytology test.

Feasibility Study of the Radiophotoluminescent Glass Dosimeter for High-energy Electron Beams (유리선량계를 이용한 고에너지 전자선 측정 이용 가능성에 관한 연구)

  • Son, Ki-Hong;Jung, Hai-Jo;Shin, Sang-Hun;Lee, Hyun-Ho;Lee, Sung-Hyun;Kim, Mi-Sook;Ji, Young-Hoon;Kim, Kum-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.52-58
    • /
    • 2011
  • Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of glass dosimeters including dose linearity, reproducibility, angular dependence, dose rate dependence, and energy dependence of 5 different electron energy qualities. The GD was irradiated with high-energy electron beams from the medical linear accelerator andgamma rays from a cobalt-60 teletherapy unit. All irradiations were performed in a water phantom. The result of the dose linearity for high-energy electron beams showed well fitted regression line with the coefficient of determination; $R^2$ of 0.999 between 6 and 20 MeV. The reproducibility of GDs exposed to the nominal electron energies 6, 9, 12, 16, and 20 MeV was ${\pm}1.2%$. In terms of the angular dependence to electron beams,GD response differences to the electron beam were within 1.5% for angles ranging from $0^{\circ}$ to $90^{\circ}$ and GD's maximum response differencewas 14% lower at 180o. In the dose rate dependence, measured dose values were normalized to the value obtained from 500 MU/min. The uncertainties of dose rate were measured within ${\pm}1.5%$ except for the value from 100 MU/min. In the evaluation of the energy dependence of the GD at nominal electron energies between 6 and 20 MeV, we obtained lower responses between 1.1% and 4.5% based on cobalt-60 beam. Our results show that GDs have a considerable potentiality for measuring doses delivered by high-energy electron beams.

Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography (폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교-)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Diagnosing and determining the stage of lung cancer by means of positron emission tomography (PET) ha.. been proven valuable because of the limitations of diagnosis by computed tomography (CT). We compared the efficacy of PET with that of CT in diagnosing pulmonary tumor and staging of lung cancer Material and Method: We performed F-18 FDG PET to determine the malignancy and the staging on patients who have been suspicious or were diagnosed as lung cancer by chest X-ray and CT. The findings of PET and of CT of 41 patients (male, 29: female, 12: mean age, 59) were compared with pathologic findings obtained from a mediastinoscopy and thoracotomy. Result: Out of 41 patients, 35 patients had malignant lesions (squamous cell carcinonla 19 cases, adenocarcinoma 14 cases, adenosquamous cell carcinoma 2 cases) and 6 patients had benign lesions. Diagnosing of lung cancer, the sensitivity, specificity and accuracy of CT and PET were the same for two method and the numbers were 100%, 50%, and 92.7% respectively. Eighteen LN groups out of 108 mediastinal LN groups who recieved histologic examination proved to be malignant. Pathologic lymph node (LN) stage was N0-Nl 31 cases, N2 8 cases, N3 2 cases. The correct identification of the nodal staging with CT, PET scans were 31 cases (75.6%), 28 cases (68.3%) respectively. The LN group was underestimated in each 6 cases of CT and PET. In 4 cases of CT and 7 cases of PET, they were overestimated in compare to histologic diagnosis. In the detection of mediastinal LN groups invasion, the sensitivity, specificity and accuracy of CT were 39.8 %, 93.3 %, and 84.3 % respectively. For PET, they were 61.1 %, 90.0 %, and 85.2 %. When two methods considered together (CT+PET), they were increased to 77.8 %, 93.3 %, and 90.7 % respectively. Conclusion: PET appears to be similar to CT in the diagnosis and the nodal taging of pulmonary tumor. Two tests may stage patients with lung cancer more accurately than CT alone.

Usefulness of $^{18}F$-FDG PET/CT in Locoregional Recurrence of Differentiated Thyroid Cancer: Comparison PET/CT to PET and Neck Ultrasonography for Biopsy-proven Lesions (갑상선유두암 재발 진단에서 $^{18}F$-FDG PET/CT와 경부초음파검사 병용의 유용성: PET, 경부초음파검사 그리고 혈청 티로글로불린 (thyroglobulin)의 비교)

  • Kim, Kun-Ho;Shong, Min-Ho;Seo, Young-Duk;Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.411-420
    • /
    • 2009
  • Purpose: The aim of this study was to investigate the usefulness of $^{18}F$-FDG PET/CT with neck ultrasonography (neck US) in patients with recurrent, papillary thyroid cancer. Material and methods: This retrospective study (December 2006 to April 2008) enrolled sixty-one patients (ninety-one lesions) who underwent high-dose $^{131}I$-ablation therapy after total thyroidectomy, and evaluated recurred papillary thyroid cancer. All lesions were confirmed by histopathology and compared histopathologic findings to PET, PET/CT, and neck US findings. Results: In sixty-one patients (57 women, 4 men; age range, 24-81 years, mean 49 years; 61 papillary carcinomas), the sensitivity, specificity, accuracy of $^{18}F$-FDG PET/CT was 87.2%, 64.0%, 78.1% on a patient basis and 92.3%, 66.7%, 80.9% on a lesion basis, respectively. The sensitivity, specificity, accuracy of $^{18}F$-FDG PET was 71.8% (p=0.03), 59.0% (p=1.00), 67.2% (p=0.03) on a patient basis and 78.8% (p<0.01), 64.1% (p=1.00), 72.5% (p=0.02) on a lesion basis, respectively. The sensitivity, specificity, accuracy of neck US was 71.1% (p=0.07), 52.2% (p=0.75), 63.9% (p=0.05) on a patient basis and 71.2% (p<0.01), 61.5% (p=1.00), 67.0% (p=0.06) on a lesion basis, respectively. Combined $^{18}F$-FDG PET/CT with neck US improved the sensitivity, specificity, accuracy to 94.7% (p=0.50), 82.6% (p=0.13), 90.2% (p=0.03) on a patient basis and 96.2% (p=0.50), 89.7% (p<0.01), 93.4% (p<0.01) on a lesion basis, respectively. Conclusion: $^{18}F$-FDG PET/CT demonstrated significantly higher sensitivity than neck US for the detection of recurred papillary thyroid cancer lesions. Furthermore, combined $^{18}F$-FDG PET/CT with neck US showed more improved sensitivity, specificity, accuracy for diagnosis of recurrent papillary thyroid cancer.

Comparison of Size Criteria in Mediastinal Lymph Node Involvement of Adenocarcinoma of Lungs (폐 선암의 종격동 림프절 전이에 있어서 림프절 크기 기준의 비교)

  • Gu, Ki-Seon;Kuk, Hiang;Koh, Hyeck-Jae;Yang, Sei-Hun;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.542-547
    • /
    • 1999
  • Background: Decision in mediastinal lymph node involvement of lung cancer by CT scan is very important and valuable for the treatment planning and prognosis prediction. In general, long diameter of mediastinal lymph node more than 15mm is used as criterion of lung cancer involvement. Adenocarci-noma has a tendency of early distant metastasis and micrometastasis, so adenocarcinoma may involve lymph node earlier and cannot be detected before lymph nodes are enlarged enough. The authors tried to determine the difference between two size criteria(15mm, 10mm) in adenocarcinoma for the detection of cancer involvement. Methods: Numbers of sample are 60 cases(male 46, female 14, median age: 61.5 years). According to pathology, squamous cancer 41, large cell cancer 2, adenocarcinoma 17. According to TNM stage, I 23, III 24, IIIA 13. Results : Mean long diameter of lymph node involvement is 16.0($\pm8.0$) mm in non-adenocarcinoma group, and that of adenocarcinoma group is 12.0($\pm3.2$) mm(p<0.05). If long diameter of lymph node larger than 15mm as involvement criterion is applied, sensitivity, specificity, positive predictive index, negative predictive index, accuracy of nonadenocarcinoma group are 54%, 100%, 100%, 83%, 86%, and those of adenocarcinoma group are 43%, 90%, 75%, 69%, 71%. If long diameter of lymph node larger than 10mm as involvement criterion is applied, sensitivity, specificity, positive predictive index. negative predictive index. accuracy of nonadenocarcinoma group are 65%, 77%, 61%, 92%, 79%, and those of adenocarcinoma group are 100%, 80%, 78%, 100%, 88%. Conclusion: Long diameter of lymph node larger than 10mm is more valuable criterion as lymph node involvement in adenocarcinoma of lungs.

  • PDF

Detection of Brain Metastatses Using Limited Brain MR Imaging : Usefulness of Limited Contrast-Enhanced MR Imaging in Brain Metastasis (뇌전이암 진단을 위한 제한적 뇌 자기공명영상의 유용성에 관한 연구)

  • Kwon, Sun Jung;Lee, Yun Sun;An, Jin Yong;Park, Hee Sun;Jung, Sung Soo;Kim, Ju Ock;Kim, Jin Hwan;Song, Chang Joon;Kim, Sun Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.499-505
    • /
    • 2003
  • Background : The brain is a common site of a metastasis in lung cancer patients. If left untreated, the patients succumb to progressive neurological deterioration with a lower survival rate than with other metastases sites. Contrast-enhanced MR imaging in the absence of symptoms or clinical signs is not recommended for identifying a cerebral metastasis in lung cancer patients because of management effectiveness. This pilot study was performed to estimate whether or not limited brain MR imaging, which has a lower cost, could be used to replace conventional brain MR imaging. Method : Between April 1999 and March 2001, 43 patients with a primary lung cancer and the others (breast cancer, stomach cancer, colon cancer, malignant melanoma etc), who had neurological symptoms and signs, were examined using conventional brain MR imaging to examine brain metastases. The control group involved four patients who had no evidence of brain metastases the sensitivity, specificity and correlation of limited brain MR imaging were compared with conventional brain MR imaging. Results : All the 43 patients who were examined with conventional brain MR imaging showed evidence of brain metastases, whereas limited brain MR imaging indicated that 42 patients had brain metastases(sensitivity=97.67%). One patient in whom limited brain MR imaging showed no brain metastasis had a metastasis in the cerebellum, as shown by the contrast-enhanced T1 weighted axial view using conventional brain MR imaging. The conventional brain MR imaging and the limited brain MI imaging of the 4 control patients both indicated no brain metastases (specificity=100 %). The Pearson Correlation of the two groups was 0.884(Confidence Interval : 99%) observed. Conclusion : Limited brain MR imaging can detect a brain metastasis with the same accuracy. In addition, it is cost-effective (229,000 won, 180$) compared to conventional brain MR imaging(529,000 won, 480$) when patients had neurological symptoms and signs or staging.