• 제목/요약/키워드: Cancellous bone thickness

검색결과 38건 처리시간 0.031초

임프란트 나사형태와 치조골 흡수에 따른 응력분산의 3차원 유한요소법적 분석 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION ACCORDING TO THE THREAD DESIGNS AND THE MARGINAL BONE LOSS OF THE IMPLANTS)

  • 김일규;손충렬;장금수;조현영;백민규;박승훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권1호
    • /
    • pp.60-71
    • /
    • 2008
  • The objective of this study is to evaluate the stress distribution according to the thread design and the marginal bone loss of a single unit dental implant under the axial and offset-axial loading by three dimensional finite element analysis. The implants used had the diameter of 5mm and 4mm with 13mm in length and prosthesis with a conical type which is 6mm in height and 12mm in diameter. The thread designs were triangular, square and buttress. In the three dimensional finite element model with $15\times15\times20mm$ hexahedron and 2mm cortical thickness, implants were placed with crown to root ratio 7:12, 10:9, 13:6 and 16:3. And additionally the axial force of 100N were applied into 0mm, 2mm and 4mm away from the center of the implants. The results were as follows 1. The maximum von-Mises stress in cortical bone was concentrated to cervical area of implant, and in cancellous bone, apical portion. 2. Comparing the von-Mises stresses in cortical bone of 2mm and 4mm offset loading with central axial loading, it were increased to 3 and 5 times in diameter 4mm implant, and 2 and 4 times, in diameter 5mm implant. 3. The square threads were more effective than the triangular and butress as the longer diameter, the offset loading, and the worse crown to root ratio. 4. The von-Mises stresses were relatively stable until crown to root ratio 13:6, but it was suddenly increased at 16:3. From the results of this study, minimum requirement of crown to root ratio of implant is 2:1, and in the respect of crown to root ratio, diameter and offset loading, square threads are more effective than triangular and buttress threads.

낭종성 병변을 동반한 상완골의 섬유성 골이형성증에서 steroid의 효과 - 증례 보고 - (The effect of steroid for fibrous dysplasia of the humerus combined with multiple cystic lesion)

  • 한수봉;신규호;김보현;원정훈
    • 대한골관절종양학회지
    • /
    • 제8권1호
    • /
    • pp.20-26
    • /
    • 2002
  • 섬유성 골이형성증은 골의 발육 이상으로 해면골이 섬유성 조직으로 대치되어 나타나는 양성 병변으로 대퇴골, 경골, 두개골, 늑골, 상완골 등에 호발하며 동통, 진행하는 병변, 병적 골절 등을 일으키기 쉬워 여러 가지 치료법이 시도되어 왔으나 그 중 골 소파 및 골 이식술이 현재까지 널리 시행되고 있다. 본 교실에서는 17세 여자 환자로 우측 상완골 전장에 걸친 다발성 골 낭종을 동반한 섬유성 골이형성증 환자에 steroid 주입법을 약 3개월 간격으로 총 2차례 시행하였고 처음 주입 후 약 11개월 후에 시행한 추시 단순 방사선 촬영상 병변의 크기가 감소하였고, 골음영 및 피질골의 두께가 증가하였으며, 자기공명영상촬영 검사상 병변의 크기가 상당히 감소하였고, T2 강조 영상에서 정상 골수의 신호강도와 비슷하게 변화 하였으며, 처음 주입 후 약 2년 8개월 후의 외래 추시상 통증 호소하지 않고 무리하지 않는 한도내에서 큰 불편 없이 지내고 있어 섬유성 골이형성증의 호전 소견을 보였기에 문헌고찰과 함께 보고하는 바이다.

  • PDF

악정형력 적용을 위한 골내 고정원으로서 미니플레이트 형상의 영향: 3차원 유한요소법적 연구 (INFLUENCE OF MINIPLATE SHAPES AS SKELETAL ANCHORAGE FOR APPLICATION OF ORTHOPEDIC FORCE: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 이남기;백승학;최동순;박영욱;김지혁;차봉근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권4호
    • /
    • pp.345-352
    • /
    • 2008
  • Purpose: This study was performed to evaluate the stress distribution in the bone and the displacement distribution of the miniscrew under orthopedic force with two different types of miniplate design as skeletal anchorage for orthopedic treatment. Materials and methods: Finite element models were made for 6-hole miniplate (0.8mm in thickness), which were designed in two different shapes-one is curvilinear shaped (C plate, Jeil Medical Co., Korea) and another, Y shaped (Y plate), fixed with 3 pieces of miniscrew 2mm-diameter and 6mm-long respectively. A traction force of 4 N was applied in $0^{\circ}$, $30^{\circ}$ and $60^{\circ}$ to imaginary axis connecting two unfixed distalmost holes of the miniplate. Results: The maximum von Mises stress in the bone was much greater in the cortical portion rather than in the cancellous portion. C plate showed greater maximum von Mises stress in the cortical bone than Y plate. The maximum displacement of the miniscrew was greater in C plate than Y plate. The more increased the angle of the applied orthopedic force, the greater maximum von Mises stress in the bone and maximum displacement of the miniscrew. It was observed that in C plate, the von Mises stress in the bone and displacement of the miniscrew were distributed around the distalmost screw-fixed area. Conclusions: The results suggest that Y plate should have the advantage over C plate and in the placement of the miniplate, its imaginary axis should be placed as parallel as possible to the direction of orthopedic force to obtain its primary stability.

Intraosseous anesthesia in symptomatic irreversible pulpitis: Impact of bone thickness on perception and duration of pain

  • Nilius, Manfred;Mueller, Charlotte;Nilius, Minou Helene;Haim, Dominik;Leonhardt, Henry;Lauer, Guenter
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권6호
    • /
    • pp.367-375
    • /
    • 2020
  • Background: Intraosseous anesthesia (IO) allows the anesthetic solution to be injected directly into the cancellous bone. The anesthetic solution immediately reaches the periapical region, and thus the axonal area of the nerve, where it can temporarily disable the sodium pump. The effect is felt almost without any time delay, and only a small amount of anesthetic solution is required. Methods: This study aims to investigate the efficacy of IO using the AnestoⓇ device after infiltration anesthesia (IA) and/or inferior alveolar nerve block anesthesia (IANB) failed to work in symptomatic irreversible pulpitis (hot tooth). The 33 patients included in the study were treated additionally with 1.7 ml articaine hydrochloride with 1:100,000 epinephrine hydrochloride (UltracainⓇ D-S, Sanofi-Aventis, Frankfurt, Germany) IO. Results: The electrical pulp test showed that 95.76% of the volunteers reacted positively to the combination of IANB or IA with the IO. In women, the additive IO was effective at 97.22%. In men, the IO led to pain elimination in 94.00% of cases. The duration of the IO was less than a quarter of an hour (13.03 min). The IO worked longer in women than in men (13.61 min vs. 12.33 min). Overall, more than every third tooth that needed trepanation was located in the posterior area of the mandible (36.4%). Treatment of hot teeth in this area was associated with an increased pulse rate and increased residual pain. There was a moderate correlation (Spearman-Rho [IRI] = 0.280) between the Visual Analog Scale (VAS) score and bone density, and a significant correlation (IRI = 0.612) between subjective residual pain and bone width. The IO resulted in a moderate, transient increase in the pulse rate by approximately 20 bpm. This is similar to the temporary increase in heart rate after conventional anesthesia techniques in non-preloaded patients and can be considered clinically irrelevant. Conclusion: IO with the AnestoⓇ device as an extension and deepening of local pain elimination is recommended for the treatment of hot teeth.

서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구 (Analysis of thermal changes in bone by various insertion torques with different implant designs)

  • 김민호;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.168-176
    • /
    • 2011
  • 연구 목적: 임플란트 식립시에 발생할 수 있는 열변화는 임플란트의 실패를 초래할 수 있다. 식립토크에 따른 열변화 양상을 파악함으로 임플란트의 형태에 따른 차이점과 적절한 식립토크가 어떤 것인지 파악하고자 한다. 연구 재료 및 방법: 실험재료로는 두께 15 - 20 mm의 소 견갑골을 가로 35 mm, 세로 40 - 50 mm 크기가 되도록 골편으로 자르고 이중에 피질골의 두께가 2 - 3 mm 되는 표본을 선정한 후 표본의 반을 $36.5^{\circ}C$ 수조에 실온 $25^{\circ}C$에 노출 시켜 내부 온도는 평균 $36.5^{\circ}C$, 표면온도 $28^{\circ}C$가 되도록 설계하였다. $4.5{\times}10\;mm$의 외부육각을 가지는 Br${\aa}$nemark 형태의 임플란트와 $4.8{\times}10\;mm$의 Microthread 형태를 지니는 내부연결 형태의 임플란트를 과도한 식립토크로 식립하고 온도 측정은 계측점에서 0.2 mm 이내에 열전대를 위치시켜 기록하였다. 삼차원유한요소 분석은 골의 형태를 가로 4 cm, 세로 4 cm, 높이 2 cm의 직육면체로 가정하고, 직육면체 윗면에서 2 mm까지를 피질골, 그 아랫부분을 해면골이라고 가정하였다. 마찰열은 매식이 종료된 상황에서 골에 남는 cavity 모양을 기초로 경계조건을 부여하였다. CAD 프로그램인 SolidWorks 소프트웨어를 이용하였고, 이를 유한요소 구조해석용 프로그램인 Abaqus 6.9-1로 불러들여 해석하였다. 결과 및 결론: In vitro실험에서 Microthread type의 임플란트가 상대적으로 더 높은 최고점 온도를 보여주고 있으며 이는 임플란트의 형태에 따른 마찰열 발생이 주요 원인으로 보인다. 유한요소분석을 통해 살펴본 결과 Br${\aa}$nemark 형태의 임플란트의 경우 50 Ncm이상에서 Microthread를 가지는 형태의 경우에는 35 Ncm이상에서 Eriksson 등이 보고한 역치를 초과하는 온도가 발생하였다. 이를 통해 볼 때 Microthread type 이 식립토크에 따른 온도 증가가 더 민감함을 알 수 있다. 실험결과를 통해서 서로 다른 형태의 임플란트 식립시에 임플란트의 형태에 따라 적절한 삽입토크를 부여하는 것이 성공적인 임플란트 시술에 중요한 요소 중에 하나임을 알 수 있었다. 특히 Microthread를 갖는 임플란트 형태는 높은 초기고정성을 얻을 수 있다는 장점이 있는 반면 과도한 식립 토크로 인한 열 손상 가능성을 가질 수 있으므로 골량과 골질의 신중한 평가와 적절한 수술기법이 필요할 것으로 생각된다.

임플란트의 직경과 길이 변화가 초기 안정성에 미치는 영향 (Influence of implant diameter and length changes on initial stability)

  • 조재명;조욱;윤미정;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.335-341
    • /
    • 2009
  • 연구목적: 충분한 골질과 골량은 임플란트의 조기 실패 방지와 초기 안정성을 위해서 중요한 사항으로 알려져 있다. 임플란트 길이나 직경이 초기 안정성에 미치는 영향을 연구한 다수의 실험들이 골과의 접촉면적을 달리하였기 때문에 직경과 길이만이 초기 안정성에 미치는 실제 영향을 파악하는데 한계가 있다. 이에 유사한 표면적을 가지는 임플란트를 통하여 길이와 직경 상대적 변화가 초기 안정성에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: 골질에 따라 피질골과 해면골의 두께가 다른 4종류의 폴리우레탄 모형골을 임플란트 식립에 사용하였다. 유사한 표면적과 형태를 가지나 직경과 길이가 서로 다른 임플란트 ($3.5{\times}13.0\;mm$, $4.0{\times}11.5\;mm$, $4.5{\times}10.0\;mm$, $5.0{\times}8.5\;mm$) 10개를 식립하고 식립 회전력과 공진 주파수를 측정하였다. 결과 및 결론: 초기 안정성에 영향을 미치는 주 요소는 골질이었으며 (P < .05), 식립 회전력과 공진 주파수 모두 골질이 우수할수록 높은 측정치를 보였다. 2. D1, D2, D3 모형골에서 임플란트의 직경이 커지고 길이가 짧아짐에 따라 공진 주파수는 유의한 차이를 보이지 않았으나 (P >.05), 식립 회전력은 증가하였다 (P <.05). 3. D4 모형골에서는 임플란트의 직경이 커지고 길이가 짧아짐에 따라 공진주파수와 식립 회전력 모두 감소하였다 (P <.05). 이상의 결과로부터 골질이 양호한 조건에서는 길이가 짧더라도 직경이 큰 임플란트의 사용이 초기 안정성 측면에서 부가적 수술의 대안이 될 수 있을 것으로 생각된다.

임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구 (Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis)

  • 이우현;임종화;조인호
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.221-239
    • /
    • 2010
  • 본 연구에서는 임플란트 지지 3-unit 고정성 보철물에서 임플란트의 수와 위치변화에 따른 지지골과 임플란트에서의 응력 분포를 삼차원 유한요소분석법으로 관찰하고자 하였다. 3개의 임플란트를 중심선 일직선상에 나란히 식립한 모델과 중심선에서 제1대구치 임플란트를 협측으로 1.5mm offset 시키고 나머지 임플란트는 설측으로 1.5mm offset 시킨 모델 및 이와 반대로 offset 시킨 모델 그리고 2개의 임플란트를 이용하여 양단 지지한 모델과 근심 및 원심 캔틸레버 모델을 만들고, 교합력도 제2소구치에만 155N을 작용한 경우, 제2대구치에만 206N을 작용한 경우, 제1소구치에는 155N, 제1, 2대구치에는 각각 206N을 동시에 적용한 경우에 대해 각각 협측 교두에 설측방향으로 $30^{\circ}$ 경사하중을 적용시켰을 때와 치아 중심와에 수직하중을 적용했을 때에 대해 유한요소법을 이용하여 골과 임플란트에 발생하는 응력 분포를 관찰하였다. 이 같은 실험 결과를 바탕으로 각각의 응력을 비교하여 다음과 같은 결과를 얻었다. 어떤 하중이 작용하더라도 더 많은 수의 임플란트를 이용하여 제작한 수복물이 골과 임플란트 자체에 작은 응력이 발생하였으며, 3개 구치 상실의 경우에 2개의 임플란트로 지지할때는 양단지지 수복물이 유리한 결과를 나타내었고, 중심와 수직하중이 아니고 협측경사 하중일 때는 협측으로 offset 한 것이 가장 좋은 결과를 나타내었다.

보급형 3D프린터 재료가 CT 영상에 미치는 영향 분석 (Analysis of the Effect of Entry-Level 3D Printer Materials on CT Images)

  • 박세환;조현정;이성준;이송빈;박상협;류대연;허영철
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.673-680
    • /
    • 2022
  • 본 연구에서는 PLA를 기반으로 알루미늄, 나무, 구리, 카본, 대리석이 각각 20% 함유된 재질들의 CT number를 분석하고 영상에 어떠한 영향을 미치는지 분석하고자 하였다. 보급형 3D 프린터를 이용하여 5×30×30 ㎣(두께×직경×높이)의 원기둥 모양 팬텀을 제작하였다. 관전압을 80, 100, 120 kV로 변화시키고, 관전류초를 100, 200 mAs로 변화시켜 테이블 중앙에 놓인 팬텀을 총 6가지 조건으로 횡단 스캔하였다. Image J를 이용하여 원형의 ROI를 설정하고 물질부 CT number의 정량값과 주변부 CNR의 정량값을 구하였다. 물질부의 CT number 평균값은 PLA-나무20%, PLA-대리석20%, PLA-카본20%, PLA-100%, PLA-알루미늄20%, PLA-구리20% 순으로 높아졌고(p<0.05), kV 증가에 따른 CT number는 음의 상관성을 확인하였다. 주변부의 CNR값은 PLA-대리석20%, PLA-구리20%, PLA-카본20%, PLA-나무20%, PLA-알루미늄20%, PLA-100% 순으로 증가 됨을 확인하였다(p<0.05). 각 재료별 HU 값과 유사한 인체 장기는 PLA-구리20%는 치밀골, PLA-알루미늄20%는 해면골, PLA-100%는 응고된 혈액, PLA-카본20%와 PLA-대리석20%는 간, 근육, 비장, PLA-나무20%는 지방과 유사한 값이었다. 또한 모든 재료에서 필라멘트 주변부 영상을 흐리게 하는 흐림 현상을 확인하였고 특히 PLA-100%에서 영상 주변부 흐림 현상이 가장 많은 것을 확인하였다. 따라서 의료용팬텀 제작의 재질을 선정할 때 목표 장기의 HU 값을 반영하고, 팬텀 주변부의 흐림 현상을 고려하는 것이 바람직하다고 판단하며 본 연구가 기초 자료를 제공할 수 있을 것이라 사료된다.