• Title/Summary/Keyword: Cam Analysis

Search Result 596, Processing Time 0.025 seconds

Some Statistical Considerations for the Estimation of Urinary Mercury Excretion in Normal Individuals (정상인의 요중 수은배설량 추정의 통계학적 연구)

  • Park, Hee-Sook;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 1980
  • Purpose of this study is to find out proper means of estimating the urinary mercury excretion in the normal individuals. Whole void volume was collected every 2 hours beginning from 6 o'clock in the morning until 6 o'clock next morning. Mercury excretion in each urine specimen was measured by NIOSH recommended dithizone colorimetric method (Method No.: P & CAM 145). Urinary concentration of mercury was adjusted by two means: specific gravity of 1.024 and a gram of creatinine excretion per liter of urine comparing the data with the unadjusted ones. Mercury excretion in 24-hour urine specimen was calculated by adding the amounts measured with the hourly collected specimens of each individual. Statistical analysis of the urinary mercury excretion revealed the following results: 1. Frequency distribution curve of mercury excreted in urine of hourly specimens was best fitted to power function expressed in the form of $y=ax^b$. Adjustment of the urinary mercury concentration by creatinine excretion was shown to be superior($y=1674x^{-1.52},\;r^2=0.95$) over nonadjustment($y=2702x^{-1.57},\;r^2=0.92$) and adjustment by specific gravity of 1.024($y=4535x^{-1.66},\;r^2=0.93$). 2. Both log-transformed mercury excretion in hourly voided specimens and mercury excretion itself in 24 hour specimens showed the normal distributions. 3. The frequency distribution of mercury adjusting the urinary concentration of mercury by creatinine excretion was best fitted to a theoretical normal distribution with the sample means and standard deviation than those unadjusted or adjusted with specific gravity of 1.024. 4. Average urinary mercury excretions in 24-hour urine specimen in an individual were as follows: a) Unadjusted mercury excretion mean and standard deviation : $$18.6{\pm}13.68{\mu}gHg/l$$. median : $$16.0\;{\mu}gHg/l$$. range : $$0.0-55.10\;{\mu}gHg/l$$. b) Adjusted with specific gravity mean : $$20.7{\pm}11.76\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ median : $$20.7\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ range : $$0.0-52.9\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ c) Adjusted with creatinine excretion mean and standard deviation : $$10.5{\pm}6.98\;{\mu}gHg/g$$ creatinine/l median : $$9.4\;{\mu}gHg/g$$ creatinine/l range : $$0.0-26.7\;{\mu}gHg/g$$ creatinine/l 5. No statistically significant differences were found between means calculated from 24-hour urine specimens and those from hourly specimens transformed into logarithmic values. (P<0.05).

  • PDF

Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods (서로 다른 두 가지 스캔법을 이용하여 제작된 지르코니아 보철물의 적합도에 대한 비교)

  • Choi, Hyun-Suk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • Purpose: This research was conducted to compare the marginal and internal fit of zirconia prostheses fabricated with the model scan method and the intraoral scan method. Materials and methods: In this study, 20 extracted human mandibular first molar was used in the preparation of abutment tooth for the fabrication of zirconia prostheses. In the first group, the model scan method was applied on 10 prepared teeth. In the other group, the intraoral scan method was used on other 10 prepared teeth. Datum of both groups were transmitted to the software system. Afterwards, 20 zirconia prostheses were fabricated using the Ceramill system. Weight technique was used to evaluate the internal gap of the zirconia prostheses. In the Replica technique, marginal gap of the zirconia prostheses were analyzed by optical microscopy. Statistical analysis was based on one-way ANOVA. Results: Model scan group showed lower average weight than intraoral scan group when weight technique was applied, which has significance (P < .05). Also, model scan group showed significantly lower figures in all 5 measurements of replica technique than intraoral scan group (P < .05). Conclusion: Zirconia prostheses of both groups demonstrated clinically acceptable margin and internal fit. However, model scanned zirconia prostheses showed higher marginal and internal fit than intraoral scanned crowns.

Development of herbicide-tolerant Korean rapeseed (Brassica napus L.) cultivars (한국 고유의 품종을 이용한 제초제 저항성 유채 개발)

  • Kim, Hyo-Jin;Lee, Hye-Jin;Go, Young-Sam;Roh, Kyung-Hee;Lee, Young-Hwa;Jang, Young-Seok;Suh, Mi-Chung
    • Journal of Plant Biotechnology
    • /
    • v.37 no.3
    • /
    • pp.319-326
    • /
    • 2010
  • An interest in the production of seed-oil based fuel and raw materials, which comes from renewable plant sources, has been intrigued by the phenomenon of global warming and shortage of fossil fuels. Rapeseed (Brassica napus) is the most important oilseed crop, which produces seeds with 40% oil. It is desirable to develop genetically modified rapeseed producing oils, which can be easily converted to biodiesel. As an initial step for development of genetically modified rapeseed for the production of biofuels or bio-based materials, Korean rapeseed cultivars, Naehan, Youngsan, Tammi and Halla, were analyzed. Four Korean rapeseed cultivars produce 32 to 40% oil of seed dry weight, which is rich in oleic acid (more than 60 mole%). The cotyledonary petioles of rapeseed cultivar, Halla, were transformed using Agrobacterium tumefaciens strain GV3101, carrying the uidA gene encoding $\beta$-glucuronidase (GUS) as a reporter gene and the phosphinothricin acetyltransferase (PAT) gene as a selectable marker. The stable integration of PAT gene in the genome of transgenic rapeseeds was confirmed by PCR analysis. Expression of uidA gene in various rapeseed organs was determined by fluorometric assay and histochemical staining. Transformation efficiency of a Korean rapeseed Halla cultivar was 10.4%. Genetic inheritance of transgenes was confirmed in $T_2$ generation.

Effect of coloring agent dryness on zirconia color (치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Hae-Jung;Moon, Yun Hee;Kim, Woong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.176-182
    • /
    • 2018
  • One of the most important factor of esthetic prosthesis is the color of the teeth. Zirconia is produced in the process of design, milling, coloring, drying, and sintering. The effect of the drying degree of zirconia colorant on the color tone is examined. For the experiment, a total of 45 zirconia specimens(15 for each) were fabricated by using cad/cam system. The zirconia specimens(L block(LAZOR), Z block(Zircos-E block posterior), A block(AlphaZ)) were then subjected to zirconia sintering in accordance with the manufacturer's instructions, using a chemical coloring agent to Non-drying(0sec), intermediate (10sec), and completely dried (10min) temperature holding times. The color tone was measured using a spectrophotometer. The results were analyzed with a One-way analysis of variance and the Tukey post-hoc test (${\alpha}=.05$) The $L^*$ values of L, A specimens, $a^*$ values of A specimens, and $b^*$ values of Z specimens were not statistically different according to the degree of drying (p>0.05), While the $L^*$ value of Z specimen, $a^*$ value of L, Z specimen, $b^*$ values of L, A specimens were statistically different according to the degree of drying(p <0.05). In conclusion, the drying of zirconia colourants improves zirconia brightness and increases the optical properties of the enamel.

SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF ZIRCONIA CORE ON THE COLOR OF CERAMIC (지르코니아 코아가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석)

  • Pae Ah-Ran;Baik Jin;Woo Yi-Hyung;Kim Hyung-Sup;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.466-477
    • /
    • 2005
  • Statement of problem : Problem of matching the appearance of porcelain restorations with the patient's natural dentition has always been a concern to dental clinicians. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. Among the various factors, shade and translucency or the core can significantly affect the overall esthetics of the restoration and should be considered when selecting an all-ceramic system. Purpose : The purpose of this study was to spectrophotometrically evaluate the influence of different zirconia systems and core thickness on the final shade of all-ceramic restorations using the CIEL$^*a^*b^*$ system. Material and Methods: Core specimens (n : 20 per group) of In-Ceram Alumina, In-Ceram Zirconia, Digident CAD/CAM Zirconia, Cercon Zirconia were fabricated 20mm in diameter. 10 specimens of each group were fabricated at core thickness of 0.5mm and 0.7mm. These core specimens were veneered with shade Al & A3 porcelain of the recommended manufacturer. CIEL$^*a^*b^*$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan). Color differences were calculated using the equation ${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{\frac{1}{2}}$. Results : 1. Specimens of core thickness 0.5mm and 0.7mm did not exhibit clinically perceived color difference. 2. Regarding shade reproducibility, In-Ceram Alumina and In-Ceram Zirconia showed significant difference within each group. 3. Cercon Zirconia group showed the highest $L^*$ value and Digident Zirconia group showed lowest $a^*$ & $b^*$ value. 4. Generally the shade difference between materials was higher in the A3 shade group than in the Al shade group. Conclusion: Within the limitations of this study, there was no color difference after increase in core thickness and every all-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Accuracy of the CT guided implant template by using an intraoral scanner according to the edentulous distance (구강스캐너를 이용하여 제작된 CT 가이드 임플란트 수술용 형판의 무치악 거리에 따른 정확도 분석)

  • Kang, Byeong-Gil;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Purpose: The purpose of this study is to compare the accuracy of the CT guided implant template that was produced by using an intraoral scanner according to the edentulous distance. Materials and methods: Five maxillary casts were fabricated using radiopaque acrylic resin with the second premolars, first molars, and second molars missing. Then a virtual cast was acquired by scanning each resin cast. Implant treatment was planned on the missing sites by superimposing the presurgical CT DICOM file and the virtual cast. Then the implants were placed using a surgical template followed by postsurgical CT scan. The distance and angle of the platform and apex between the presurgical implant and postsurgical implant were measured using the X, Y, and Z axis of the superimposed presurgical CT and postsurgical CT via software followed by statistical analysis using Kruskall-Wallis test and Mann-Whitney test. Results: The implant placement angle error increased towards the second molars but there was no statistically significant difference. The implant placement distance error at the platform and apex also increased towards the second molars and there was a statistically significant error at the second molars. Conclusion: Although the placement angle had no statistically significant difference between the presurgical implant and postsurgical implant, the placement distance at the platform and apex showed a larger error and a statistically significant difference at the second molar implant.

Effect of coloring agent on the color of zirconia (Coloring agent가 지르코니아 색조 재현성에 미치는 영향)

  • Kim, Kwanghyun;Noh, Kwantae;Pae, Ahran;Woo, Yi-Hyung;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.18-25
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the effect of two types of coloring agents and the number of application on the color of zirconia. Materials and methods: Monolithic zirconia specimens ($15.7mm{\times}15.7mm{\times}2.0mm$) (n = 33) was prepared and divided into 11 groups. Each experimental group was coded as a1-a5, w1-w5 according to the type of coloring agent and number of application. Specimens with no coloring agent applied were set as control group. The color difference of specimen was measured by using double-beam spectrophotometer, and calculated color difference (${{\Delta}E^*}_{ab}$), translucency parameter (TP). All data was analyzed with two-way ANOVA, multiple comparison $Sch{\acute{e}}ffe$ test, Pearson correlation and linear regression analysis. Results: As the number of application increased, values of $CIE\;L^*$ was decreased, but values of $CIE\;b^*$ was increased in both coloring agents. However, there was no significant difference on values of translucency parameter. The color difference range of each group was ${0.87{\Delta}E^*}_{ab}$ to ${9.43{\Delta}E^*}_{ab}$. Conclusion: In this study, type of coloring agent and the number of application did not affect the color difference of zirconia.

A Study about the News Searched on Web-site Related to HRT and Analysis of Perimenopausal and Postmenopausal Patient Who Visited Dept, of Ob&Gy Korean Medicine Hospital (폐경후 호르몬대체요법에 대한 인터넷 웹싸이트 자료 내용 및 학술 연구 경향 분석과 국내 한방병원 내원환자에 관한 연구)

  • Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.1
    • /
    • pp.219-235
    • /
    • 2006
  • Purpose : To investigate the medical information related to HRT online and the medical treatment of perimenopausal and postmenopausal women in the Dept. of Ob&Gy Korean Medicine Hospital, after the discontinuance of the WHI trial in U.S, July 2002. Methods : With the key-words "HRT", "Hormone Replacement therapy", "호르몬 대체요법(HRT)", 갱년기 증후군(perimenopausal syndrome)", “폐경기후증후군(postmenopausal syndrome)", I searched for the information from July 2002 to 2005 on DAUM, the representative portal site in Korea, and I've got a grasp of the tendency of the informational propagation on HRT. Moreover, I investigated chief complaints and tendency of give up HRT of the perimenopausal and postmenopausal women(aged between 47 and 60) who visited Dept. of Ob&Gy Korean Medicine Hospital for 2 years and 6 months since July 2002. Results : 1) Searching for the news on DAUM, I found; 2 articles on the methods of HRT: 4 on the positive effects of HRT: 4 on the general items including the positive effects of HRT: 19 on the side effects of HRT: 1 on the insignificant effect of HRT :4 on the apprehensions about HRT: 3 on the strengthening of the criteria on medical fees review: 3 on the discontinuance of HRT: 8 on the alternative materials and medicines to HRT: 4 on the guidance for the phyto-estrogen. 2) I analyzed chief complaints of 120 women. The majority of chief complaints were vasomotor symptoms like hot flush and sweating. There were only 4 patients who wanted to give up HRT. Conclusion : The side effects of HRT were objectively dealt with online but there was not enough effective and continuous guidance. In the case that a woman not on HRT wishes to overcome perimenopausal period through KM therapy, this information may have affected her decision. However, not many women who were already on HRT terminated the therapy for fear of side effects and switched to KM therapy. Promotion of KM therapy in improving health during perimenopausal and postmenopausal period is desperately needed.

  • PDF

Factors Related to Motor Subtypes of Delirium Patients in a Surgical Intensive Care Unit (일 종합병원 외과 중환자실 환자의 섬망 아형별 관련 요인)

  • Park, Sang Hee;Kim, Hee Jeong;Choi, Hee Young;You, Ji Eun;Park, Ji Eun;Kim, Eun Jung;Lim, Soo Jung
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.207-216
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the motor subtypes of delirium in patients in a Surgical Intensive Care Unit (SICU), and identify the factors related to the characteristics of patients according to the motor subtypes of delirium. Methods: Data were collected in the SICU of a tertiary hospital in city from October 2018 to June 2019. Delirium was detected using the Confusion Assessment Method for the ICU (CAM-ICU) and motor subtypes of delirium were measured with the Delirium Motor Subtype Scale (DMSS)-4. Patients' characteristics were obtained by using the electronic medical records. Descriptive statistics were used to analyze the data. Results: Among 1,112 patients, 172 patients showed delirium (15.5%). After excluding dementia patients and patients refusing to participate in the study, 126 patients included in the final analysis. Delirium patients were classified as hyperactive delirium (32.5%), hypoactive delirium (42.9%), mixed delirium (11.9%), and non-motor subtype delirium (12.7%). Conclusion: The study results suggest that hypoactive delirium is the most prevalent motor subtype of delirium in SICU. More application of ventilators, more administration of sedatives, more use of catheters, and higher nursing severity were reported for hypoactive delirium cases than hyperactive ones. Therefore, it is necessary to assess early the motor subtypes of delirium using structured tools and develop appropriate nursing interventions suitable for each subtype of delirium.

Digital Video Source Identification Using Sensor Pattern Noise with Morphology Filtering (모폴로지 필터링 기반 센서 패턴 노이즈를 이용한 디지털 동영상 획득 장치 판별 기술)

  • Lee, Sang-Hyeong;Kim, Dong-Hyun;Oh, Tae-Woo;Kim, Ki-Bom;Lee, Hae-Yeoun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • With the advance of Internet Technology, various social network services are created and used by users. Especially, the use of smart devices makes that multimedia contents can be used and distributed on social network services. However, since the crime rate also is increased by users with illegal purposes, there are needs to protect contents and block illegal usage of contents with multimedia forensics. In this paper, we propose a multimedia forensic technique which is identifying the video source. First, the scheme to acquire the sensor pattern noise (SPN) using morphology filtering is presented, which comes from the imperfection of photon detector. Using this scheme, the SPN of reference videos from the reference device is estimated and the SPN of an unknown video is estimated. Then, the similarity between two SPNs is measured to identify whether the unknown video is acquired using the reference device. For the performance analysis of the proposed technique, 30 devices including DSLR camera, compact camera, camcorder, action cam and smart phone are tested and quantitatively analyzed. Based on the results, the proposed technique can achieve the 96% accuracy in identification.