• Title/Summary/Keyword: Calibration process

Search Result 762, Processing Time 0.034 seconds

Preliminary Analysis of Data Quality and Cloud Statistics from Ka-Band Cloud Radar (Ka-밴드 구름레이더 자료품질 및 구름통계 기초연구)

  • Ye, Bo-Young;Lee, GyuWon;Kwon, Soohyun;Lee, Ho-Woo;Ha, Jong-Chul;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2015
  • The Ka-band cloud radar (KCR) has been operated by the National Institute of Meteorological Research (NIMR) of Korea Meteorological Administration (KMA) at Boseong National Center for Intensive Observation of severe weather since 2013. Evaluation of data quality is an essential process to further analyze cloud information. In this study, we estimate the measurement error and the sampling uncertainty to evaluate data quality. By using vertically pointing data, the statistical uncertainty is obtained by calculating the standard deviation of each radar parameter. The statistical uncertainties decrease as functions of sampling number. The statistical uncertainties of horizontal and vertical reflectivities are identical (0.28 dB). On the other hand, the statistical uncertainties of Doppler velocity (spectrum width) are 2.2 times (1.6 times) larger at the vertical channel. The reflectivity calibration of KCR is also performed using X-band vertically pointing radar (VertiX) and 2-dimensional video disdrometer (2DVD). Since the monitoring of calibration values is useful to evaluate radar condition, the variation of calibration is monitored for five rain events. The average of calibration bias is 10.77 dBZ and standard deviation is 3.69 dB. Finally, the statistical characteristics of cloud properties have been investigated during two months in autumn using calibrated reflectivity. The percentage of clouds is about 26% and 16% on September to October. However, further analyses are required to derive general characteristics of autumn cloud in Korea.

Identification of Apple Cultivars using Near-infrared Spectroscopy

  • Choi, Sun-Tay;Chung, Dae-Sung;Lim, Chai-Il;Chang, Kyu-Seob
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1624-1624
    • /
    • 2001
  • Near-infrared spectroscopy (NIRS) was used to investigate the possibility for application in identification of apple cultivars. Three apple cultivars ‘Kamhong, Hwahong, and Fuji’ produced in Korea were scanned over the range of 1100-2500nm using NIRS (Infra Alzer 500). Two types of samples were used for scanning; one was apple with skin and the other was apple without skin. For cultivar identification, the NIR absorbance spectrums were analyzed by qualitative calibration in “Sesame” analysis program, and the various influence properties such as sugar contents, acidity, color, firmness, and micro-structure were compared in scanned samples. The ‘Kamhong’ cultivar could be identified from ‘Hwahong’ and ‘Fuji’ cultivars using the cluster model analysis. The test samples in calibration between ‘Kamhong’ and ‘Fuji’ cultivars could be completely identified. The test samples in calibration between ‘Kamhong’ and ‘Hwahong’ cultivars could be identified most of all. But, ‘Hwahong’ and ‘Fuji’ cultivars could not be quite classified each other. The apple skin influenced the identification process of apple cultivars. The samples without skin were more difficult to classify in calibration than the samples with skin. The physicochemical properties of apple cultivars showed like the result of identification in calibration using NIRS. Some physicochemical properties of ‘Kamhong’ cultivar were different from those of the other cultivars. Those of ‘Hwahong’ and ‘Fuji’ cultivars showed. similar to each other. The sucrose contents of ‘Kamhong’ cultivar were higher and the fructose contents and firmness of skin and flesh were lower than those of the others. The hypodermis layer of skin in ‘Kamhong’ cultivar was thinner than those of the others. In this studies, the identification of all apple cultivars by NIRS was not quite accurate because of the physicochemical properties which were different in the same cultivar, and inconsistent patterns by culivars in some properties. To solve these problems in NIRS application for apple cultivar identification, further study should be focused on the use of peculiar properties among the apple cultivars.

  • PDF

Design and Implementation of IoT-Based Intelligent Platform for Water Level Monitoring (IoT 기반 지능형 수위 모니터링 플랫폼 설계 및 구현)

  • Park, Jihoon;Kang, Moon Seong;Song, Jung-Hun;Jun, Sang Min
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.4
    • /
    • pp.177-186
    • /
    • 2015
  • The main objective of this study was to assess the applicability of IoT (Internet of Things)-based flood management under climate change by developing intelligent water level monitoring platform based on IoT. In this study, Arduino Uno was selected as the development board, which is an open-source electronic platform. Arduino Uno was designed to connect the ultrasonic sensor, temperature sensor, and data logger shield for implementing IoT. Arduino IDE (Integrated Development Environment) was selected as the Arduino software and used to develop the intelligent algorithm to measure and calibrate the real-time water level automatically. The intelligent water level monitoring platform consists of water level measurement, temperature calibration, data calibration, stage-discharge relationship, and data logger algorithms. Water level measurement and temperature calibration algorithm corrected the bias inherent in the ultrasonic sensor. Data calibration algorithm analyzed and corrected the outliers during the measurement process. The verification of the intelligent water level measurement algorithm was performed by comparing water levels using the tape and ultrasonic sensor, which was generated by measuring water levels at regular intervals up to the maximum level. The statistics of the slope of the regression line and $R^2$ were 1.00 and 0.99, respectively which were considered acceptable. The error was 0.0575 cm. The verification of data calibration algorithm was performed by analyzing water levels containing all error codes in a time series graph. The intelligent platform developed in this study may contribute to the public IoT service, which is applicable to intelligent flood management under climate change.

Design of IGRINS Wavelength Calibration System

  • Oh, Hee-Young;Pak, Soo-Jong;Yuk, In-Soo;Park, Chan;Lee, Sang-On;Chun, Moo-Young;Kim, Kang-Min;Lee, Sung-Ho;Pyo, Tae-Soo;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • IGRINS (the Immersion GRating Infrared Spectrograph) is a high resolution infrared spectrograph which is being developed by a collaboration of the University of Texas, the Korea Astronomy and Space Science Institute, and Kyung Hee University. The wavelength calibration unit of IGRINS will be situated between the telescope flange and IGRINS dewar. It will include Th-Ar hallow cathode lamp, optical elements, and gas absorption cell for the case that requires precise calibration (e.g., radial velocity observation). The system will also use a tungsten halogen lamp in an integrating sphere as a blackbody source for the flat-field imaging. IGRINS will be placed initially on the McDonald 2.7m Harlan J. Smith telescope and later on 4-8m class telescopes. We present an overview of the plan for the wavelength calibration sources and of the development process for the optical and mechanical design of the IGRINS calibration system.

  • PDF

Computer Vision Based Measurement, Error Analysis and Calibration (컴퓨터 시각(視覺)에 의거한 측정기술(測定技術) 및 측정오차(測定誤差)의 분석(分析)과 보정(補正))

  • Hwang, H.;Lee, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • When using a computer vision system for a measurement, the geometrically distorted input image usually restricts the site and size of the measuring window. A geometrically distorted image caused by the image sensing and processing hardware degrades the accuracy of the visual measurement and prohibits the arbitrary selection of the measuring scope. Therefore, an image calibration is inevitable to improve the measuring accuracy. A calibration process is usually done via four steps such as measurement, modeling, parameter estimation, and compensation. In this paper, the efficient error calibration technique of a geometrically distorted input image was developed using a neural network. After calibrating a unit pixel, the distorted image was compensated by training CMLAN(Cerebellar Model Linear Associator Network) without modeling the behavior of any system element. The input/output training pairs for the network was obtained by processing the image of the devised sampled pattern. The generalization property of the network successfully compensates the distortion errors of the untrained arbitrary pixel points on the image space. The error convergence of the trained network with respect to the network control parameters were also presented. The compensated image through the network was then post processed using a simple DDA(Digital Differential Analyzer) to avoid the pixel disconnectivity. The compensation effect was verified using known sized geometric primitives. A way to extract directly a real scaled geometric quantity of the object from the 8-directional chain coding was also devised and coded. Since the developed calibration algorithm does not require any knowledge of modeling system elements and estimating parameters, it can be applied simply to any image processing system. Furthermore, it efficiently enhances the measurement accuracy and allows the arbitrary sizing and locating of the measuring window. The applied and developed algorithms were coded as a menu driven way using MS-C language Ver. 6.0, PC VISION PLUS library functions, and VGA graphic functions.

  • PDF

Development of a Computation Program for Automatic Processing of Calibration Data of Radiation Instrument (방사선 측정기 교정 데이터의 자동처리를 위한 전산프로그램 개발)

  • Jang, Ji-Woon;Shin, Hee-Sung;Youn, Cheung;Lee, Yun-Hee;Kim, Ho-Dong;Jung, Ki-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.246-254
    • /
    • 2006
  • A computation program has been developed for automatic data processing in the calibration process of gamma survey meter. The automatic processing program has been developed based on Visual Basic. The program has been coded according to steps of calibration procedure. The OLE(object linking an embedding) Excel automation method fur automatic data processing is used in this program, which is a kind of programming technique for the Excel control. The performance test on the basis of reference data has been carried out by using the developed program. In the results of performance test, the values of calibration factors and uncertainties by the developed program were equal to those obtained from the reference data. In addition, It was revealed that the efficiency and precision of working are significantly increased by using the developed program.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Determination of Calibration Curve for Total Nitrogen Contents Analysis in Fresh Rice Leaves Using Visible and Near Infrared Spectroscopy (벼 생체엽신 질소함량 측정을 위한 근적외선분광분석의 검량식 작성)

  • Kwon Young-Rip;Baek Mi-Hwa;Choi Dong-Chil;Choi Joung-Sik;Choi Yeong-Geun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.6
    • /
    • pp.394-399
    • /
    • 2005
  • Near Infrared Spectroscopy (NIRS) has been used as a tool for the rapid, accurate and nondestructive assay of the fresh rice leaf in nitrogen content. NIRS used in this study was visible and near infrared spectroscopy type instrument, Foss model 6500. To obtain a useful calibration equation, standard regression between the data was analyzed by chemical analysis and by NIRS method. Accuracy of calibration equation for nitrogen content on fresh leaf of rice were 0.879, 0.858 and 0.819, respectively. Accuracy of calibration equation after outlier treatment increased as 0.017, 0.02 and 0.061 improved each with 0.896, 0.878 and 0.880, respectively. Calibration equation combined using merge function after accuracy of calibration equation more increased by 0.911. Difference analysis value between calibration equation and lab value by kjeldahl showed $0.001\%$. With this as same result is the possibility of closing the deterioration of the sample in order to omit a construction and pulverization process it is judged with the fact that the nitrogen content measurement of the fresh rice leaf which the possibility of reducing an hour and an expense is by a near infrared spectroscopy technique will be possible.

3D Feature Based Tracking using SVM

  • Kim, Se-Hoon;Choi, Seung-Joon;Kim, Sung-Jin;Won, Sang-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1458-1463
    • /
    • 2004
  • Tracking is one of the most important pre-required task for many application such as human-computer interaction through gesture and face recognition, motion analysis, visual servoing, augment reality, industrial assembly and robot obstacle avoidance. Recently, 3D information of object is required in realtime for many aforementioned applications. 3D tracking is difficult problem to solve because during the image formation process of the camera, explicit 3D information about objects in the scene is lost. Recently, many vision system use stereo camera especially for 3D tracking. The 3D feature based tracking(3DFBT) which is on of the 3D tracking system using stereo vision have many advantage compare to other tracking methods. If we assumed the correspondence problem which is one of the subproblem of 3DFBT is solved, the accuracy of tracking depends on the accuracy of camera calibration. However, The existing calibration method based on accurate camera model so that modelling error and weakness to lens distortion are embedded. Therefore, this thesis proposes 3D feature based tracking method using SVM which is used to solve reconstruction problem.

  • PDF

Real Time Eye and Gaze Tracking

  • Park Ho Sik;Nam Kee Hwan;Cho Hyeon Seob;Ra Sang Dong;Bae Cheol Soo
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.857-861
    • /
    • 2004
  • This paper describes preliminary results we have obtained in developing a computer vision system based on active IR illumination for real time gaze tracking for interactive graphic display. Unlike most of the existing gaze tracking techniques, which often require assuming a static head to work well and require a cumbersome calibration process for each person, our gaze tracker can perform robust and accurate gaze estimation without calibration and under rather significant head movement. This is made possible by a new gaze calibration procedure that identifies the mapping from pupil parameters to screen coordinates using the Generalized Regression Neural Networks (GRNN). With GRNN, the mapping does not have to be an analytical function and head movement is explicitly accounted for by the gaze mapping function. Furthermore, the mapping function can generalize to other individuals not used in the training. The effectiveness of our gaze tracker is demonstrated by preliminary experiments that involve gaze-contingent interactive graphic display.

  • PDF