• Title/Summary/Keyword: Calibration image

Search Result 803, Processing Time 0.029 seconds

A NEW APPROACH OF CAMERA MODELING FOR LINEAR PUSHBROOM IMAGES

  • Jung, Hyung-Sup;Kang, Myung-Ho;Lee, Yong-Woong;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1162-1164
    • /
    • 2003
  • The methods of the geometric reconstruction and sensor calibration of satellite linear pushbroom images are investigated. The model of the sensor used is based on the SPOT model that is developed by Kraiky. The satellite trajectory is a Keplerian trajectory in the approximation. Four orbit parameters, longitude of the ascending node(${\omega}$), inclination of the orbit plan(I), latitude argument of the satellite(W) and distance between earth center and satellite, are used for the camera modeling. Time-dependent orbit parameters are expressed by quadratic polynomials. SPOT-5 images have been used for validation tests. The results are that the RMSE acquired from 20 GCPs is 1.763m and the RMSE of 5 checking points 2.470m. Because the ground resolution of SPOT-5 is 2.5m, the result obtained in this study has a good accuracy. It demonstrates that the sensor model developed by this study can be used to reconstruct the geometry of satellite image using pushbroom camera.

  • PDF

A New Method of Noncontact Measurement for 3D Microtopography in Semiconductor Wafer Implementing a New Optical Probe based on the Precision Defocus Measurement (비초점 정밀 계측 방식에 의한 새로운 광학 프로브를 이용한 반도체 웨이퍼의 삼차원 미소형상 측정 기술)

  • 박희재;안우정
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.129-137
    • /
    • 2000
  • In this paper, a new method of noncontact measurement has been developed for a 3 dimensional topography in semiconductor wafer, implementing a new optical probe based on the precision defocus measurement. The developed technique consists of the new optical probe, precision stages, and the measurement/control system. The basic principle of the technique is to use the reflected slit beam from the specimen surface, and to measure the deviation of the specimen surface. The defocusing distance can be measured by the reflected slit beam, where the defocused image is measured by the proposed optical probe, giving very high resolution. The distance measuring formula has been proposed for the developed probe, using the laws of geometric optics. The precision calibration technique has been applied, giving about 10 nanometer resolution and 72 nanometer of four sigma uncertainty. In order to quantitize the micro pattern in the specimen surface, some efficient analysis algorithms have been developed to analyse the 3D topography pattern and some parameters of the surface. The developed system has been successfully applied to measure the wafer surface, demonstrating the line scanning feature and excellent 3 dimensional measurement capability.

  • PDF

Development of a Remote Object's 3D Position Measuring System (원격지 물체의 삼차원 위치 측정시스템의 개발)

  • Park, Kang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.60-70
    • /
    • 2000
  • In this paper a 3D position measuring device that finds the 3D position of an arbitarily placed object using a camersa system is introduced. The camera system consists of three stepping motors and a CCD camera and a laser. The viewing direction of the camera is controlled by two stepping motors (pan and tilt motors) and the direction of a laser is also controlled by a stepping motors(laser motor). If an object in a remote place is selected from a live video image the x,y,z coordinates of the object with respect to the reference coordinate system can be obtained by calculating the distance from the camera to the object using a structured light scheme and by obtaining the orientation of the camera that is controlled by two stepping motors. The angles o f stepping motors are controlled by a SGI O2 workstation through a parallel port. The mathematical model of the camera and the distance measuring system are calibrated to calculate an accurate position of the object. This 3D position measuring device can be used to acquire information that is necessary to monitor a remote place.

  • PDF

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Wafer Position Recognition System Using Radial Shape Calibrator (방사형 캘리브레이터률 이용한 웨이퍼 위치 인식시스템)

  • Lee, Byeong-Guk;Lee, Joon-Jae
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.5
    • /
    • pp.632-641
    • /
    • 2011
  • This paper presents a position error recognition system when the wafer is mounted in cleaning equipment among the wafer manufacturing processes. The proposed system is to enhance the performance in cost and reliability by preventing the wafer cleaning system from damaging by alerting it when it is put in correct position. The proposed algorithm is in obtaining a mapping function from camera and physical wafer by designing and manufacturing the radial shape calibrator to reduce the error by using the conventional chess board one. The system is to install in-line process using high reliable and high accurate position recognition. The experimental results show that the performance of the proposed system is better than that of the existing method for detecting errors within tolerance.

A Framework for Real Time Vehicle Pose Estimation based on synthetic method of obtaining 2D-to-3D Point Correspondence

  • Yun, Sergey;Jeon, Moongu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.904-907
    • /
    • 2014
  • In this work we present a robust and fast approach to estimate 3D vehicle pose that can provide results under a specific traffic surveillance conditions. Such limitations are expressed by single fixed CCTV camera that is located relatively high above the ground, its pitch axes is parallel to the reference plane and the camera focus assumed to be known. The benefit of our framework that it does not require prior training, camera calibration and does not heavily rely on 3D model shape as most common technics do. Also it deals with a bad shape condition of the objects as we focused on low resolution surveillance scenes. Pose estimation task is presented as PnP problem to solve it we use well known "POSIT" algorithm [1]. In order to use this algorithm at least 4 non coplanar point's correspondence is required. To find such we propose a set of techniques based on model and scene geometry. Our framework can be applied in real time video sequence. Results for estimated vehicle pose are shown in real image scene.

Atmospheric Aerosol Detection And Its Removal for Satellite Data

  • Lee, Dong-Ha;Lee, Kwon-Ho;Kim, Young-Joan
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.5
    • /
    • pp.379-383
    • /
    • 2006
  • Satellite imagery may contain large regions covered with atmospheric aerosol. A highresolution satellite imagery affected by non-homogenous aerosol cover should be processed for land cover study and perform the radiometric calibration that will allow its future application for Korea Multi-Purpose Satellite (KOMPSAT) data. In this study, aerosol signal was separated from high resolution satellite data based on the reflectance separation method. Since aerosol removal has a good sensitivity over bright surface such as man-made targets, aerosol optical thickness (AOT) retrieval algorithm could be used. AOT retrieval using Look-up table (LUT) approach for utilizing the transformed image to radiometrically compensate visible band imagery is processed and tested in the correction of satellite scenery. Moderate Resolution Imaging Spectroradiometer (MODIS), EO-l/HYPERION data have been used for aerosol correction and AOT retrieval with different spatial resolution. Results show that an application of the aerosol detection for HYPERION data yields successive aerosol separation from imagery and AOT maps are consistent with MODIS AOT map.

CONSTRUCTION OF AN ENVIRONMENTAL RADON MONITORING SYSTEM USING CR-39 NUCLEAR TRACK DETECTORS

  • AHN GIL HOON;LEE JAI-KI
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.395-400
    • /
    • 2005
  • An environmental radon monitoring system, comprising a radon-cup, an etching system, and a track counting system, was constructed. The radon cup is a cylindrical chamber with a radius of 2.2 cm and a height of 3.2 cm in combination with a CR-39 detector. Carbon is impregnated in the bodies of the detector chamber to avoid problem of an electrostatic charge. The optimized etching condition for the CR-39 exposed to a radon environment turned out to be a 6 N NaOH solution at 70^{\circ}$ over a 7hour period. The bulk etch rate under the optimized condition was $1.14{\pm}0.03\;{\mu}m\;h^{-1}$. The diameter of the tracks caused by radon and its progeny were found to be in the range of $10\~25\;{\mu}m$ under the optimized condition. The track images were observed with a track counting system, which consisted of an optical microscope, a color charged couple device (CCD) camera, and an image processor. The calibration factor of this system is obtained to be $0.105{\pm}0.006$ tracks $cm^2$ per Bq $m^{-3}$ d.

A Monocular Vision Based Technique for Estimating Direction of 3D Parallel Lines and Its Application to Measurement of Pallets (모노 비전 기반 3차원 평행직선의 방향 추정 기법 및 파렛트 측정 응용)

  • Kim, Minhwan;Byun, Sungmin;Kim, Jin
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.11
    • /
    • pp.1254-1262
    • /
    • 2018
  • Many parallel lines may be shown in our real life and they are useful for analyzing structure of objects or buildings. In this paper, a vision based technique for estimating three-dimensional direction of parallel lines is suggested, which uses a calibrated camera and is applicable to an image being captured from the camera. Correctness of the technique is theoretically described and discussed in this paper. The technique is well applicable to measurement of orientation of a pallet in a warehouse, because a pair of parallel lines is well detected in the front plane of the pallet. Thereby the technique enables a forklift with a well-calibrated camera to engage the pallet automatically. Such a forklift in a warehouse can engage a pallet on a storing rack as well as one on the ground. Usefulness of the suggested technique for other applications is also discussed. We conducted an experiment of measuring a real commercial pallet with various orientation and distance and found for the technique to work correctly and accurately.

High Accuracy Skeleton Estimation using 3D Volumetric Model based on RGB-D

  • Kim, Kyung-Jin;Park, Byung-Seo;Kang, Ji-Won;Kim, Jin-Kyum;Kim, Woo-Suk;Kim, Dong-Wook;Seo, Young-Ho
    • Journal of Broadcast Engineering
    • /
    • v.25 no.7
    • /
    • pp.1095-1106
    • /
    • 2020
  • In this paper, we propose an algorithm that extracts a high-precision 3D skeleton using a model generated using a distributed RGB-D camera. When information about a 3D model is extracted through a distributed RGB-D camera, if the information of the 3D model is used, a skeleton with higher precision can be obtained. In this paper, in order to improve the precision of the 2D skeleton, we find the conditions to obtain the 2D skeleton well using the PCA. Through this, high-quality 2D skeletons are obtained, and high-precision 3D skeletons are extracted by combining the information of the 2D skeletons. Even though this process goes through, the generated skeleton may have errors, so we propose an algorithm that removes these errors by using the information of the 3D model. We were able to extract very high accuracy skeletons using the proposed method.