• Title/Summary/Keyword: Calibration factor

Search Result 437, Processing Time 0.026 seconds

A Compensator to Advance Gyro-Free INS Precision

  • Hung Chao-Yu;Fang Chun-Min;Lee Sou-Chen
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.351-358
    • /
    • 2006
  • The proposed inertial measurement unit (IMU) is composed of accelerometers only. It can determine a vehicle's position and attitude, which is the Gyro-free INS. The Gyro-free INS error is deeply affected by the sensor bias, scale factor and misalignment. However, these parameters can be obtained in the laboratory. After these misalignments are corrected, the Gyro-free strap-down INS could be more accurate. This paper presents a compensator design for the strap-down six-accelerometer INS to correct misalignment. A calibration experiment is taken to get the error parameters. A simulation results show that it will decrease the INS error to enhance the performance after compensation.

The General Analysis of an Active Stereo Vision with Hand-Eye Calibration (핸드-아이 보정과 능동 스테레오 비젼의 일반적 해석)

  • Kim, Jin Dae;Lee, Jae Won;Sin, Chan Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.83-83
    • /
    • 2004
  • The analysis of relative pose(position and rotation) between stereo cameras is very important to determine the solution that provides three-dimensional information for an arbitrary moving target with respect to robot-end. In the space of free camera-model, the rotational parameters act on non-linear factors acquiring a kinematical solution. In this paper the general solution of active stereo that gives a three-dimensional pose of moving object is presented. The focus is to achieve a derivation of linear equation between a robot′s end and active stereo cameras. The equation is consistently derived from the vector of quaternion space. The calibration of cameras is also derived in this space. Computer simulation and the results of error-sensitivity demonstrate the successful operation of the solution. The suggested solution can also be applied to the more complex real time tracking and quite general and are applicable in various stereo fields.

The General Analysis of an Active Stereo Vision with Hand-Eye Calibration (핸드-아이 보정과 능동 스테레오 비젼의 일반적 해석)

  • 김진대;이재원;신찬배
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.89-90
    • /
    • 2004
  • The analysis of relative pose(position and rotation) between stereo cameras is very important to determine the solution that provides three-dimensional information for an arbitrary moving target with respect to robot-end. In the space of free camera-model, the rotational parameters act on non-linear factors acquiring a kinematical solution. In this paper the general solution of active stereo that gives a three-dimensional pose of moving object is presented. The focus is to achieve a derivation of linear equation between a robot's end and active stereo cameras. The equation is consistently derived from the vector of quaternion space. The calibration of cameras is also derived in this space. Computer simulation and the results of error-sensitivity demonstrate the successful operation of the solution. The suggested solution can also be applied to the more complex real time tracking and quite general and are applicable in various stereo fields.

Reliability analysis of tunnels with consideration of the earthquakes extreme events

  • Azadi, Mohammad;Ghasemi, S. Hooman;Mohammadi, Mohammadreza
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.433-439
    • /
    • 2020
  • Tunnels are one of the most important constructions in civil engineering. The damage to these structures caused enormous costs. Therefore, the safe and economic design of these structures has long been considered. However, both applied loads on the tunnels as well as the resistance of the structural members are naturally uncertain parameters, hence, the design of these structures requires considering the probabilistic approaches. This study aims to determine the load and resistant factors of lining tunnels concerning the earthquake extreme events limit state function. For this purpose, tunnels that have been designed according to the previous design codes (AASHTO Tunnel LRFD 2017) and using reliability analysis, the optimum reliability of these structures for different loading scenarios is determined. In this paper, the tunnel is considered circular. Finally, the proper load and resistance factors are calculated corresponding to the obtained target reliability. Based on the performed calibration earthquake extreme events limit state function, the result of this study can be recommended to AASHTO Tunnel LRFD 2017.

Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard (물 흡수선량 표준에 기반한 선량교정 프로그램 개발)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.175-183
    • /
    • 2003
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma (or exposure) calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to the uncertainty of the physical parameters used. Recently, the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocols(IAEA TRS-398 and AAPM TG-51). The dose calibration programs for these two protocols were developed. This program for high energy photon and electron beams was also developed for users to use in a window environment using the Visual C++ language. The formalism and physical parameters of these two protocols were strictly applied to the program. The tables and graphs of the physical data, and the information of ion chambers were numericalized for their incorporation into a database. This program can be useful in developing new dosimetry protocols in Korea.

  • PDF

Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer (자궁경부암의 강내치료를 위한 선량측정)

  • 김진기;김정수;김형진;권형철
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 1995
  • Dose distribution of HDR-RALS source represents an inverse square law as the distance. Difference of measurement value and calculation value according of brachytherapy. Therefore, in HDR-RALS dose calibration and calculation have an important effect in treatment of uterine cervical cancer and absorbed dose of interesting points. In intracavitary therapy, particula attention is paid for precise determination of the doses to be applied. In this report, we have discussed that the calibration of a HDR-RALS, differences between calculation dose use of isodose chart and measurement in rectum. Dose rate calibration of radiation sources are obtained from air kerma and Г factor with calibraed ion chamber for cobalt source. and used semiconductor detector for compared with measurement in phantom. Eighteen patients were treated with a HDR-RALS for intrcavitarty irradiation (ICR) using a cobalt-cesium source. Repoductivity of dose measurements were 0.3 -1.1% in phantom. The means of dose distribution was -6- +21% between calculation of isodose chart and measurement of recyum, and was same mean value upper 6.3% in measurement value than calculation does.

  • PDF

Application of Levenberg Marquardt Method for Calibration of Unsteady Friction Model for a Pipeline System (관수로 부정류 마찰항 보정을 위한 Levenberg Marquardt 방법의 적용연구)

  • Park, Jo Eun;Kim, Sang Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.4
    • /
    • pp.389-400
    • /
    • 2013
  • In this study, a conventional pipeline unsteady friction model has been integrated into Levenberg Marquardt method to calibrate friction coefficient in a pipeline system. The method of characteristics has been employed as the modeling platform for the frequency dependant model of unsteady friction. In order to obtain Hessian and Jacobian matrix for optimization, the direct differentiation of pressure to friction factor was calculated and sensitivities to friction for heads and discharges were formulated for implementation to the integration constant in the characteristic method. Using a hypothetical simple pipeline system, time series of pressure, introduced by a sudden valve closure, were obtained for various Reynolds numbers. Convergency in fiction factors were evaluated both in steady and unsteady friction models. The comparison of calibration performance between the proposed method and genetic algorithm indicates that faster and stabler behaviour of Levenberg Marquardt method than those of evolutionary calibration.

A Calibration Method of the CSC Model for Considering Material Properties of Ultra-high Performance Concrete (초고성능 강섬유 보강 콘크리트 물성 반영을 위한 소성 기반 콘크리트 CSC 모델 보정기법)

  • Gang-Kyu, Park;MinJoo, Lee;Sung-Wook, Kim;Hyun-Seop, Shin;Jae Heum, Moon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.402-410
    • /
    • 2022
  • The present study introduces a calibration method of the CSC model implemented in the LS-DYNA program for considering the material properties of ultra-high performance concrete(UHPC). Based on previous experimental studies, various parameters, which constitute three shear failure surfaces, pressure-volumetric strain curve, fracture energy, dynamic increase factor(DIF), and so on, are modified. Then, the proposed calibration method is verified by comparing the numerical result with the experimental data through the single element analysis. In addition, based on the established finite element models, the applicability of the calibrated CSC model is examined for UHPC structures subjected to impact and blast loadings.

The Uncertainty Analysis of SWAT Simulated Streamflow Applied to Chungju Dam Watershed (충주댐 유역의 유출량에 대한 SWAT모형의 예측불확실성 분석)

  • Joh, Hyung-Kyung;Park, Jong-Yoon;Shin, Hyung-Jin;Lee, Ji-Wan;Kim, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.29-29
    • /
    • 2011
  • SWAT (Soil and Water Assessment Tool) 모형은 물리적 기반의 준분포형 강우-유출 모형으로서, 대규모의 복잡한 유역에서 장기간에 걸친 다양한 종류의 토양과 토지이용 및 토지관리 상태에 따른 유출과 유사 및 오염물질의 거동에 대한 토지관리 방법의 영향을 예측이 가능하여, 수자원 관리 계획 및 유역관리를 위한 의사결정 지원 등 그 적용 범위가 매우 광범위하다. 이러한 모형의 적용성 검증을 위해서는 매개변수 민감도 분석 및 검 보정, 예측 불확실성 분석을 필요로 한다. 최근 수문 모델의 불확실성을 분석하기 위한 다양한 기법들이 개발 되었는데, 본 연구는 충주댐 유역(6,581.1 m)을 대상으로 유역출구점의 실측 일 유출량 자료(1998~2003)를 바탕으로 SWAT 모형의 유출관련 매개변수(총 18개)에 대한 불확실성 분석을 실시하였다. 이때 사용된 분석 기법으로는 SUFI2 (Sequential Uncertainty FItting algorithm 2), GLUE (Generalized Likelihood Uncertainty Estimation), ParaSol (Parameter Solution)등을 적용 하였다. 이러한 기법은 모두 SWAT-CUP (SWAT-Calibration Uncertainty Program, Abbaspour, 2007) 모형에 탑재되어있으며, 모형의 결과로써 검 보정, 매개변수의 민감도 분석, 각종 목적 함수 및 불확실성의 범위 등이 자동으로 산출 되므로 모형의 사용자가 불확실성 평가 기법의 분석 및 비교를 손쉽게 할 수 있다. 그 결과 대표적인 목적 함수인 결정 계수( $^2$)와 NSE (Nash-Sutcliffe Model Efficiency)는 모두 0.65에서 0.92사이의 값을 나타내어 대체적으로 모의가 잘 이루어졌음을 알 수 있었다. 그러나 불확실성의 범위를 나타내는 지표인 p-factor 및 r-factor에서는 평가 기법 별로 그 차이가 확연하게 드러났다. 여기서 p-factor는 불확실성 범위에 실측치가 포함되는 비율이며, r-factor는 불확실성의 상대적인 범위로 각각 1과 0에 가까울수록 모의 기법의 성능이 우수함을 의미한다. 세 가지 알고리듬 중에서 SUFI2의 p-factor가 약 0.51로 가장 높게 나타났으며, ParaSol의 r-factor가 0.00으로 가장 작게 나타났다. 여기서 p-factor는 불확실성 범위에 실측치가 포함되는 비율이며, r-factor는 불확실성의 상대적인 범위를 의미한다. 본 연구의 결과는 SWAT 모형을 이용한 수문모델링에서 수문분석에 따른 예측결과의 불확실성을 정량적으로 평가함으로서, 모형의 적용성 평가 및 모의결과의 신뢰성 확보에 근거자료로 활용이 가능할 것으로 판단된다.

  • PDF

Neutron Personal Dose Equivalent Evaluation Using Panasonic UD-809P Type TLD Albedo Dosimeters (Panasonic UD-809P 알비도 열형광선량계를 이용한 중성자 개인선량당량 평가)

  • Shin, Sang-Woon;Son, Joong-Kwon;Jin, Hua
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.143-154
    • /
    • 1999
  • Panasonic UD-809P type albedo neutron TL dosimeters mounted on a water phantom were used to measure neutron personal dose equivalent in a Korean nuclear power plant. From the measured TL readings, personal dose equivalents from thermal, epithermal and fast neutrons were evaluated by using a method adopted in a neutron dose calculation algorithm for Panasonic UD-809P type albedo neutron TL dosimeters, which was suggested in a Panasonic TLD System User's Manual. The results showed that personal dose equivalent from fast neutrons could not be adequately evaluated in a field with high thermal neutron fraction to be encountered in a nuclear power plant. This seems to be related to the incomplete incidence of albedo thermal neutrons to the TL dosimeters. In order to evaluate appropriately the personal dose equivalent from fast neutrons in the field condition, new method fer the neutron dose calculation algorithm was suggested. In this new method, neutrons are grouped into thermal neutrons and fast neutrons. For each neutron component, equations for TL response, sensitivity factor, calibration factor and personal dose equivalent were derived.

  • PDF