• Title/Summary/Keyword: Calibration Standard

Search Result 1,155, Processing Time 0.033 seconds

Verification of TDR and FDR Sensors for Volumetric Soil Water Content Measurement in Sandy Loam Soil (사양토에서의 용적수분 함량 측정을 위한 TDR 및 FDR 센서의 검증)

  • Hur, Seung-Oh;Ha, Sang-Keun;Kim, Jeong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.2
    • /
    • pp.110-116
    • /
    • 2009
  • This study was to verify and calibrate seven kinds of soil water sensors for volumetric soil water content(VSWC) measurement under field. Types of sensors were TDR (Time Domain Reflectometry) and FDR(Frequency Domain Reflectometry). Two kinds of TDR were TRIME(profile type), and Mini-TRASE(rod type). Five kinds of FDR were EasyAG, EnviroSCAN, PR-1(profile type), and WET-1(rod type). VSWC by TRIME and Mini-TRASE compared with VSWC by soil core showed the standard error of about 2.4%, and 1.4% which is the smallest value among all the sensors used in the experiment, respectively. The errors of EasyAG and EnviroSCAN analyzed with scaled frequency(SF) were about 2.6%, and 2.8% and those by 1 versus 1 correspondence were about 2.6%, and 2.6%, respectively. WET-1 showed about 2.0% of error, which is the smallest value among errors by FDR sensors. PR-1 with the error of about 4.7% should be hard for application in field. Therefore, users on soil water sensors have to take into consideration the errors of sensors revealed after the calibration for the correct measurement of VSWC in field. The rest except for PR-1 among the sensors could be used for VSWC measurement with 1.4~2.6% error.

Study on Determination of Boron using the PGAA Facility at HANARO Research Reactor (하나로의 즉발감마선 방사화분석 장치를 이용한 붕소의 정량에 대한 연구)

  • Chung, Young-Sam;Cho, Hyun-Jae;Moon, Jong-Hwa;Kim, Sun-Ha;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.391-398
    • /
    • 2003
  • Basic research for the determination of boron content in biological sample has been carried out using the PGAA facility of the 24MW research reactor(HANARO). For investigation of characteristics for the measurement condition, neutron flux and its homogeneity were measured at irradiating geometry. The size of thermal neutron beam collimated from beam guide is $2{\times}2cm^2$ at the sample position. The neutron flux measured was the range of $1.0{\sim}6.5{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, and flux distribution from center within the radius of 4.5 mm and 9.0 mm was $5.77{\pm}0.71{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$ and $4.68{\pm}1.64{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, respectively. Accordingly, sample size is adjusted within 10 mm for a homogeneous irradiation of high quality. Measurement system is designed to reduce the background source by Compton scattering and to improve the analytical sensitivity. To investigate the energy calibration and Compton suppression effect of gamma-ray counting system, the background conditions on both of Compton and single-mode were measured using NaCl standard. On the other hand, degree of spectral interference for sodium 472 keV peak as a matrix effect in the sample is established for an accurate boron analysis, and then boron content in three certified reference materials (NIST SRM 1570a, 1547, 1573a) was measured by using two modes and the results were compared with each other.

Evaluation of Testosterone Metabolites/Dehydroepiandrosterone As the Indicators of Testosterone Administration in Horse Doping (경주마 약물검사에서 testosterone 투여 여부표지자로서의 testosterone 대사체들에 대한 dehydroepiandrosterone의 비율 평가)

  • Kim, Jin Young;Choi, Man Ho;Kim, Sung Jean;Kyong, Jin Burm;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.190-195
    • /
    • 1999
  • The metabolism of testosterone ($17{\beta}$-hydroxy-androst-4-en-3-one) was confirmed in horse after a single intramuscular administration of testosterone cypionate (750 mg). Solvent extracts of urine obtained with enzymatic hydrolysis and methanolysis were analyzed by GC/MS after oxime t-butyldimethylsilyl (oxime-TBDMS) derivatization. The structures of four urinary metabolite after testosterone administration in horse were determined based on EI mass spectra and $5{\alpha}$-androstane-$3{\beta}$, $17{\alpha}$-diol and $5{\alpha}$-androstane-$3{\beta}$-ol-17-one as major was confirmed with authentic standard. Also the concentrations of $5{\alpha}$-androstane-$3{\beta}$, $17{\alpha}$-diol, $5{\alpha}$-androstane-$3{\beta}$, $17{\beta}$-diol, dehydroepiandrosterone (DHEA), $5{\alpha}$-androstane-$3{\beta}$-ol-17-one and testosterone were determined in the urine of normal subjects and the urine after administration. The recovery and detection limit in the most drugs were 86.3~94.7% and 1~3 ppb, respectively. Correlation coefficients for calibration were in the range of 0.984~0.999. Excretion profile of testosterone presents the rapid and large increasement up to maximum values at days 5 after administration and the slow regression. The relative ratios of testosterone, its metabolites over DHEA were determined for indication of testosterone administration in horse doping.

  • PDF

Determination of Amitrole in Water Samples by Evaporation and GC/MS (증발법과 GC/MS를 이용한 수질 시료 중의 Amitrole의 분석법 연구)

  • Yoon, So Hee;Hong, Ji Eun;Pyo, Hee Soo;Park, Song Ja
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.483-487
    • /
    • 2003
  • Amitrole is well-known as a non-selective herbicide and it is able to cause contamination of driking water as well as pollution of ground water and surface water. However, it is difficult to extract from water because it has a high solubility for water whereas a low solubility for general organic solvents. This method is described for the determination of amitrole in water samples by GC/MS. After evaporation of 10 mL water sample by a vacuum evaporator, amitrole was derivatized with isobutyl chloroformate (iso-BCF) on room temperature for 15~20 min. As a result, the sensitivity for GCfMS was improved as N-isobutoxycarbonyl amitrole derivative was formed. The linearity of the calibration curve showed good as 0.997. The recoveries were obtained more than 94.9% and relative standard deviations were less than 2.8% at $1.0{\mu}g/L$, $10.0{\mu}g/L$ and $100.0{\mu}g/L$. The limit of detection showed $0.1{\mu}g/L$ with a signal-to-noise ratio (S/N) of 3.

Gastrointestinal and Hepatic First-pass Effects of Triflusal in Rats (흰쥐에서 트리플루살의 위장관 및 간 초회통과효과)

  • Cho, Hea-Young;Jeong, Tae-Jin;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.4
    • /
    • pp.265-271
    • /
    • 2001
  • In order to elucidate the influence of intestinal and hepatic first-pass effect on the pharmacokinetics of triflusal, the biotransformation of triflusal in the gastrointestinal tract and liver was designed. Moreover, we tried to establish an HPLC method applicable for bioassay and available to pharmacokinetics, not only with the simultaneous determination of triflusal and its active metabolite, 2-hydroxy-4-trifluoromethyl benzoic acid (HTB), but also with improving sensitivity. After the administration of triflusal (10 mg/kg) and HTB (10 mg/kg) into femoral vein, portal vein (only triflusal) and oral route (only triflusal), pharmacokinetic parameters were investigated from the plasma concentration-time profiles of triflusal and HTB in rats. An HPLC method was developed for the simultaneous determination of triflusal and HTB in rat plasma, urine and bile. The HPLC analysis was carried out using a C18 column and acetonitrile-methanol-water (25:10:65, v/v/v) as the mobile phase and UV detection at 234 nm. Furosemide was used as the internal standard. The calibration curves were linear over the concentration range $0.05-5.0\;{\mu}g/ml$ for triflusal and $0.2-200.0\;{\mu}g/ml$ for HTB with correlation coefficients greater than 0.999 and with intra-day or inter-day coefficients of variation not exceeding 10.0%. This assay procedure was applied to the study of metabolite pharmacokinetics of triflusal and HTB in rats. It was supposed that triflusal was almost metabolized in vivo because urinary and biliary excreted amounts of triflusal could be ignored as it was lower than 1.2% of the administered dose. According to the gastrointestinal and hepatic biotransformation pathways of triflusal, it was found that triflusal was hydrolyzed by about 5% in intestine and metabolized by about 53% in liver, and that the bioavailability of triflusal after oral administration of triflusal was 0.44, and also that the fraction of total elimination rate of triflusal which formed HTB in liver $(F_{mi},\;%)$ was about 98%. These results showed that triflusal was almost metabolized in liver, and the total elimination of triflusal in the body was dependent to the formation rate of HTB from triflusal in liver.

  • PDF

HPLC Analysis and Pharmacokinetics of KAL-1120, a Novel Anti-inflammation Agent, in Rats (흰쥐에서 항염증제 후보물질 KAL-1120의 HPLC 분석 및 약물동태)

  • Shin, Dae-Hwan;Lee, Jung-Yeol;Park, Seong-Hyeok;Lee, Gyeong-Bok;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of N-(-4-Chlorophenyl)-6-hydroxy-7-methoxy-2-chromanecarboxamide (KAL-1120), a novel anti-inflammation agent, in the rat plasma. The method was applied to analyze the compound in the biological fluids such as bile, urine and tissue homogenates. After liquid-liquid extraction, the compound was analyzed on an HPLC system with ultraviolet detection at 275 nm. HPLC was carried out using reversed-phase isocratic elution with a $C_{18}$ column, a mobile phase of a mixture of acetonitril (40 v/v%) at a flow rate of 1.0 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma was linear over the concentration range of 0.05-50 ${\mu}g$/mL. The intra- and inter-day assay accuracies of this method ranged from 0.06% to 9.33% of normal values and the precision did not exceed 6.28% of relative standard deviation. The plasma concentration of KAL-1120 decreased to below the quantifiable limit at 1.5 hr after the i.v. bolus administration of 2-10 mg/kg to rats ($t_{1/2,({\alpha})}$ and $t_{1/2,({\beta})$ of 2.15 and 26.7 min at a dose of 2 mg/kg, 3.91 and 33.0 min at a dose of 10 mg/kg, respectively). The steady-state volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) were not significantly altered in rats given doses from 2 to 10 mg/kg. Of the various tissues tested, KAL-1120 was mainly distributed in the lung and heart after i.v. bolus administration. KAL-1120 was detected in the bile by 30 min after its i.v. bolus administration. However, the concentration in the urine after i.v. bolus administration became too low to measure, suggesting that KAL-1120 is mostly excreted in the bile. In conclusion, this analytical method was suitable for the preclinical pharmacokinetic studies of KAL-1120 in rats.

Development of Analytical Methods of Hyperoside from Rosa canina L. (Rosa canina L. 중 hyperoside의 시험법 개발 연구)

  • Oh, Jae Myoung;Lee, Hwa Jung;Bahn, Kyeong Nyeo;Seo, Il Won;Lee, Young Joo;Lee, Jin Hee;Park, Ji Min;Kang, Tae Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.173-177
    • /
    • 2015
  • Rosa canina L. is health functional food materials that can help to temporarily relieve symptoms of arthritis. This study has been conducted to develop and validate analytical methods for hyperoside of Rosa canina L.. Methods based on HPLC with ultraviolet detection (UVD) were established through instrumental analytical conditions, and the examination of data, such as domestic and foreign reliable methods and journals. HPLC UVD analysis using Capcell Pak $C_{18}$ MG II column at 353 nm was determined on test through the column, mobile phase. The validation has been performed on the method to determine linearity, accuracy, limits of quantification (LOQ) and repeatability for hyperoside. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.999, and the LOQ was $0.393{\mu}g/mL$. Relative standard deviation (RSD) values of data from repeatability precision was between 0.6 and 2.6%. Recovery rate test at hyperoside scored between 98 and 99%. These results indicate that the established HPLC method is very useful for the determination of hyperoside in Rosa canina L. to develop a health functional material.

Analysis of quercetin in extract of Hovenia dulcis Thunb (헛개나무과병추출물 중 퀘르세틴 분석)

  • Hu, SooJung;Oh, Jae-Myoung;Oh, Hyun-Suk;Moon, Myung-Hee;Bae, Yun-Young;Lee, Sung-Hye;Kim, Ji-An;Koo, Yong-Eui
    • Analytical Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.255-260
    • /
    • 2016
  • Based on the Korean Health Functional Food Act, health functional foods are dietary supplements containing nutrients or other substances that have nutritional or physiological effects. Since generic health functional food items have been expanded, this project was performed to develop a standardized analytical method of examining such sale items. The method exhibited high linearity in the quercetin calibration curve ($R^2$ > 0.999) over concentrations of $0-40{\mu}g/mL$. The limits of detection and quantitation for quercetin were $0.12{\mu}g/mL$ and $0.36{\mu}g/mL$, respectively, while quercetin recovery was 97.1-105.4 % with standard deviations of 1.15-3.11 %. To verify the accuracy of the analytical methods, the labeled amounts of purchased health functional foods were monitored. The recovery rate for multiple quercetin concentrations ranged from 82.5-105.1 % of the labeled amounts. Thus, the new method was suitable for all cases.

Analytical method validation and monitoring of levulinic acid in soy sauce and their application to food (간장 및 이를 활용한 식품의 레불린산 분석방법 검증 및 모니터링)

  • Kim, Dan-Bi;Kim, Sunyoung;Lee, Sanghee;Yoo, Miyoung
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.295-302
    • /
    • 2017
  • This study presents a method validation for extraction and quantitative analysis of levulinic acid in soy sacues using high performance liquid chromatograph-photodiode array detector (HPLC-PDA). The levulinic acid in samples were extracted with distilled water, and then purified with C18 Sep-Pak cartridge. The calibration curves showed good linearity (R > 0.999) in a relatively wide concentration range ($2.5-400{\mu}g/mL$). Mean recoveries and relative standard deviation (RSD) of levulinic acid spiked in soy sauce samples at different spiking levels ($2.5-400{\mu}g/mL$; 6 point). Recoveries were 87.58-97.26 % with RSD less than 15 %, and limit of detection (LOD) and limit of quantification (LOQ) were 0.64 and $1.64{\mu}g/mL$, respectively. According to monitoring result with the established method, levulinic acid was found in 43 of 59 domestic commercial soy sauces, soy sauce based sauces and seasoned meats. The contamination levels were 0.44-1.23 mg/mL for soy sauces, 0.03-0.83 mg/mL for soy sauce based sauces and 8.43-38.94 mg/mL for seasoned meats. The results indicated to be rapidly and accurately qualifying levulinic acid and can be used as a suitable quality control method for soy sauce and soy sauce related commodities.

Development and Validation of a Simultaneous Analytical Method for the Detection of Mefentrifluconazole and Triticonazole Fungicide in Agricultural Crops (농산물 중 메펜트리플루코나졸 및 트리티코나졸 살균제의 동시 분석법 개발 및 검증)

  • Park, Ji-Su;Lee, Han Sol;Lee, Su Jung;Shin, Hye-Sun;Shim, Jae-Han;Yun, Sang Soon;Jung, Yong-hyun;Oh, Jae-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.2
    • /
    • pp.130-137
    • /
    • 2020
  • BACKGROUND: Mefentrifluconazole and triticonazole are the triazole fungicides. The maximum residue levels for agricultural products need to be set up. Therefore, development of the official analytical method for determination of mefentrifluconazole and triticonazole residues from agricultural crops was necessary due to safety management, and then a simultaneous analytical method was developed for the determination of mefentrifluconazole and triticonazole in agricultural crops. METHODS AND RESULTS: Samples were extracted using acetonitrile and purified using dispersive solid phase extraction, and then detected with liquid chromatograph-tandem mass spectrometry (LC-MS/MS). Matrix-matched calibration curves (0.0025-0.25 ㎍/mL) were linear into a sample extract with r2>0.99. For validation, the recovery test was carried out at three fortification levels (LOQ, 10 LOQ and 50 LOQ) from agricultural samples. The results for mefentrifluconazole and triticonazole ranged between 92.3 to 115.3% and 91.4 to 108.5%, respectively and RSD (relative standard deviation) values were also below 6.0%. Furthermore, inter-laboratory was conducted to validate the method. CONCLUSION: All values were corresponded with the criteria ranges requested by both the CODEX (CAC/GL 40-1993, 2003) and MFDS guidelines (2016). Therefore, the proposed method can be used as an official analytical method for determination of mefentrifluconazole and triticonazole (triazole fungicides) in the Republic of Korea.