• Title/Summary/Keyword: Calibration Routine

Search Result 73, Processing Time 0.031 seconds

Calibration and maintenance of partial discharge measuring system in compliance to IEC 60270 (IEC 60270에 따른 부분방전 측정 시스템의 교정 및 유지관리 방법)

  • Kim, Ji-Hwan;Roh, Chang-Il;Kim, Geun-Yong;Park, Nam-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.656_657
    • /
    • 2009
  • IEC 60270 에서는 부분방전 시험회로와 측정 시스템에 관하여 기술하고 있을 뿐 아니라 측정 시스템의 교정 및 교정기(Calibrator) 와 측정 시스템의 유지 관리 방법에 대해서 규정하고 있다. 유지관리 방법으로는 type tests, routine tests, performance tests, performance checks 가 있으며, 본 논문에서는 사용자가 주기적으로 시행하는 performance tests, performance check 에 관하여 기술한다.

  • PDF

RUNOFF ESTIMATION FROM TWO MID-SIZE WATERSHEDS USING SWAT MODEL

  • Kim, Chulg-yum;Kim, Hyeon-jun;Jang, Cheol-hee;Kim, Nam-won
    • Water Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.193-202
    • /
    • 2003
  • SWAT model was applied to estimate daily stream flow for Yongdam and Bocheong watersheds in Korea. The model was calibrated and validated for the two watersheds and a new routine was added to analyze runoff process in paddy fields. The model efficiencies for two watersheds were 0.77 and 0.65 for the calibration period, and 0.76 and 0.50 for the validation period, respectively. It showed that water balance method simulated the runoff from paddy fields more precisely than CN method in SWAT. As results, the SWAT model is applicable to Korean watersheds, and more accurate estimation is possible using daily water balance method in paddy fields.

  • PDF

Applications of Near Infrared Reflectance Spectroscopy(NIRS) in Forage Evaluation (조사료 가치 평가를 위한 근적외선 분광법(NIRS)의 활용)

  • 박형수;이종경;이효원
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.24 no.1
    • /
    • pp.81-90
    • /
    • 2004
  • Farmers need timely information on the nutritional status of their animals and the nutritive value of pastures and supplementary feeds if they are to apply successfully this existing nutritional information. Near infrared reflectance(NIR) spectroscopy has been used over the last forty years to analyse accurately protein, fiber, and other organic components in animal foods. NIR spectroscopy is a rapid, non-destructive, and non-polluting technology. When properly calibrated, NIR spectroscopy is used successfully with both concentrate and forage feeds. NIR methods predict in vitro digestibility accurately and precisely, and can predict in vivo digestibility at least as well as conventional "wet chemistry" methods such as in vivo digestion or the pepsin-cellulase method, and much more rapidly. NIR technology has been applied to the routine monitoring (through analysis of feces samples) of the nutritional status of cattle and other grazing animals. This report reviews the use of near infrared reflectance(NIR) spectroscopy to monitor the nutritive value of animal feeds and the nutritional status of grazing animals.

An Evaluation of Liquid Chromatography/Mass Specrometry with Atmospheric Pressure Chemical Ionizarion for the Rapid and Simultaneous Measurement of Carbamate Pesticides and Organophosphorus Pesticides

  • Kim, Byeong Ju;So, Hyeon Yeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.471-476
    • /
    • 2000
  • Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtrained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 ㎍/mL. Teh peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to run. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng.

NIRS Analysis of Liquid and Dry Ewe Milk

  • Nunez-Sanchez, Nieves;Varo, Garrido;Serradilla-Manrique, Juan M.;Ares-Cea, Jose L.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1251-1251
    • /
    • 2001
  • The routine analysis of milk chemical components is of major importance both for the management of animals in dairy farms and for quality control in dairy industries. NIRS technology is an analytical technique which greatly simplifies this routine. One of the most critical aspects in NIRS analysis of milk is sample preparation and analysis modes which should be fast and straightforward. An important difficulty when obtaining NIR spectra of milk is the high water content (80 to 90%) of this product, since water absorbs most of the infrared radiation, and, therefore, limits the accuracy of calibrating for other constituents. To avoid this problem, the DESIR system was set up. Other ways of radiation-sample interaction adapted for liquids or semi-liquids exist, which are practically instantaneous and with limited or null necessity of sample preparation: Transmission and Folded Transmission or Transflectance. The objective of the present work is to compare the precision and accuracy of milk calibration equations in two analysis modes: Reflectance (dry milk) and Folded Transmission (liquid milk). A FOSS-NIR Systems 6500 I spectrophotometer (400-2500 nm) provided with a spinning module was used. Two NIR spectroscopic methods for milk analysis were compared: a) folded transmission: liquid milk samples in a 0.1 pathlength sample cell (ref. IH-0345) and b) reflectance: dried milk samples in glass fibre filters placed in a standard ring cell. A set of 101 milk samples was used to develop the calibration equations, for the two NIR analysis modes, to predict casein, protein, fat and dry matter contents, and 48 milk samples to predict Somatic Cell Count (SCC). The calibrations obtained for protein, fat and dry matter have an excellent quantitative prediction power, since they present $r^2$ values higher than 0.9. The $r^2$ values are slightly lower for casein and SCC (0.88 and 0.89 respectively), but they still are sufficiently high. The accuracy of casein, protein and SCC equations is not affected by the analysis modes, since their ETVC values are very similar in reflectance and folded transmission (0.19% vs 0.21%; 0.16% vs 0.19% and 55.57% vs 53.11% respectively), Lower SECV values were obtained for the prediction of fat and dry matter with the folded transmission equations (0.14% and 0.25% respectively) compared to the results with the reflectance ones (0.43% and 0.34% respectively). In terms of accuracy and speed of analytical response, NIRS analysis of liquid milk is recommended (folded transmission), since the drying procedure takes 24 hours. However, both analysis modes offer satisfactory results.

  • PDF

Development of a 3D Laser Scanner Based Tunnel Scanner (3D 레이저 스캐너 기반의 터널스캐너 개발)

  • SaGong, Myung;Moon, Chul-Yi;Lee, Jun-S.;Hwang, Seon-Keun;Kim, Byung-Hong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.377-388
    • /
    • 2006
  • Most structures experience deterioration after construction. A routine inspection and maintenance must be accomplished for the efficient use of the structures. The routine inspection will play a major role on the determination of maintenance period and method. This study aims development of an automated tunnel inspection system based upon a 3 dimensional laser scanner. As for the initial stage of the project, a prototype tunnel scanner has been developed. The development of a tunnel scanner prototype follows comparison between image scanning and laser scanning system and investigation on the applicability and adaptivity of the scanners to the railway tunnel scanner. The applicability of the laser scanner on the railway tunnel has been confirmed from the pilot test by using commercialized general purpose close range laser scanner and applicability of a laser scanner as a railway tunnel scanner has been checked. From the result, a prototype of railway tunnel scanner has been built and the calibration of the system was carried out. Finally the developed tunnel laser scanner has been applied to different shapes and sizes of tunnels in use.

Mid-infrared (MIR) spectroscopy for the detection of cow's milk in buffalo milk

  • Anna Antonella, Spina;Carlotta, Ceniti;Cristian, Piras;Bruno, Tilocca;Domenico, Britti;Valeria Maria, Morittu
    • Journal of Animal Science and Technology
    • /
    • v.64 no.3
    • /
    • pp.531-538
    • /
    • 2022
  • In Italy, buffalo mozzarella is a largely sold and consumed dairy product. The fraudulent adulteration of buffalo milk with cheaper and more available milk of other species is very frequent. In the present study, Fourier transform infrared spectroscopy (FTIR), in combination with multivariate analysis by partial least square (PLS) regression, was applied to quantitatively detect the adulteration of buffalo milk with cow milk by using a fully automatic equipment dedicated to the routine analysis of the milk composition. To enhance the heterogeneity, cow and buffalo bulk milk was collected for a period of over three years from different dairy farms. A total of 119 samples were used for the analysis to generate 17 different concentrations of buffalo-cow milk mixtures. This procedure was used to enhance variability and to properly randomize the trials. The obtained calibration model showed an R2 ≥ 0.99 (R2 cal. = 0.99861; root mean square error of cross-validation [RMSEC] = 2.04; R2 val. = 0.99803; root mean square error of prediction [RMSEP] = 2.84; root mean square error of cross-validation [RMSECV] = 2.44) suggesting that this method could be successfully applied in the routine analysis of buffalo milk composition, providing rapid screening for possible adulteration with cow's milk at no additional cost.

Predicting Calcium and Phosphorus Concentrations in Imported Hay by near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입건초의 Ca과 P 함량 예측)

  • Lee, Bae Hun;Kim, Ji Hye;Oh, Mirae;Lee, Ki Won;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.41 no.1
    • /
    • pp.29-34
    • /
    • 2021
  • Near infrared reflectance spectroscopy (NIRS) is routinely used for the determination of nutrient components of forages. However, little is known about the impact of sample preparation and wavelength on the accuracy of the calibration to predict minerals. This study was conducted to assess the effect of sample preparation and wavelength of near infrared spectrum for the improvement of calibration and prediction accuracy of Calcium (Ca) and Phosphorus (P) in imported hay using NIRS. The samples were scanned in reflectance in a monochromator instrument (680-2,500 nm). Calibration models (n = 126) were developed using partial least squares regression (PLS) based on cross-validation. The optimum calibrations were selected based on the highest coefficients of determination in cross validation (R2) and the lowest standard error of cross-validation (SECV). The highest R2 and the lowest SECV were obtained using oven-dry grinded sample preparation and 1,100-2,500 nm wavelength. The calibration (R2) and SECV were 0.99 (SECV: 468.6) for Ca and 0.91 (SECV: 224.7) for P in mg/kg DM on a dry weight, respectively. Results of this experiment showed the possibility of NIRS method to predict mineral (Ca and P) concentration of imported hay in Korea for routine analysis method to evaluate the feed value.

Application of Enzymatic method to Determine Choline Concentration in Bovine Blood and Muscle (소의 혈액 및 근육 중 choline 농도 분석을 위한 효소측정법의 적용기법의 개발)

  • Kim, Young-Il;Jung, Won-Chul;Shon, Ho-Yeong;Kim, Suk;Hur, Yoen;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.271-275
    • /
    • 2008
  • Choline is important an organic compound for normal membrane function, acetylcholine synthesis, lipid transport, and methyl metabolism. In biological tissues and foods, there are multiple choline compounds that contribute to choline content. There are so many analytical methods for choline determination, such as radioisotopic, high-performance liquid chromatography, and gas chromatography/mass spectrometry. However, these existing methods are expensive, unmanageable, and time-consuming. In this study, we modified enzymatic method, which is applicable for the determination of choline in milk and infant formulas, and applied to bovine serum and muscle. The calibration curves were linear with higher correlation coefficients than 0.994. Recoveries obtained by calibration curves from the spiked bovine serum and muscle samples varied between 70.6 and 85.2%. The method may be suitable for use as a routine method in the determination of choline for biological tissue and food samples.

Study for Residue Analysis of Fluxametamid in Agricultural Commodities

  • Kim, Ji Young;Choi, Yoon Ju;Kim, Jong Soo;Kim, Do Hoon;Do, Jung Ah;Jung, Yong Hyun;Lee, Kang Bong;Kim, Hyochin
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • BACKGROUND: Accurate and simple analytical method determining Fluxametamid residue was necessary in various food matrices. Additionally, fulfilment of the international guideline of Codex (Codex Alimentarius Commission CAC/GL 40) was required for the analytical method. In this study, we developed Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method to determine the Fluxametamid residue in foods. METHODS AND RESULTS: Fluxametamid was extracted with acetonitrile, partitioned and concentrated with dichloromethane. To remove the interferences, silica SPE cartridge was used before LC-MS/MS (Liquid Chromatography-Tandem Mass Spectrometry) analysis with $C_{18}$ column. Five agricultural commodities (mandarin, potato, soybean, hulled rice, and red pepper) were used as a group representative to verify the method. The liner matrix-matched calibration curves were confirmed with coefficient of determination ($r^2$) greater than 0.99 at calibration range of 0.001-0.25 mg/kg. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. Mean average accuracies were shown to be 82.24-115.27%. The precision was also shown to be less than 10% for all five samples. CONCLUSION: The method investigated in this study was suitable to the Codex guideline for the residue analysis. Thus, this method can be useful for determining the residue in various food matrices as routine analysis.