• 제목/요약/키워드: Calibration Method

검색결과 2,822건 처리시간 0.028초

광 픽업 성능 평가기 캘리브레이션 (Calibration of an Optical Pick-up Performance Evaluator)

  • 류정래;도태용
    • 제어로봇시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.578-583
    • /
    • 2014
  • Optical pick-up is a core component for data read/write operations in optical disc drives, and an optical pick-up performance evaluator is an instrument used to analyze the overall performance of an optical pick-up. Due to inevitable errors in an analog measurement circuit, resultant evaluation data is not guaranteed to be accurate. In this paper, a calibration method for an optical pick-up performance evaluator is proposed to ensure evaluation accuracy. Measured data is corrected by a 1st order correction function, and a calibration process based on least-square method is utilized to obtain correction coefficients of the correction function. The proposed calibration method is applied to experiments, and enhanced accuracy is presented with resultant evaluation data.

GC의 주입방식 차에 따른 고농도 악취황 성분의 검량오차 연구 : 주입부피의 고정방식 대비 주입농도의 고정방식 간 비교연구 (The Selection of Sample Injection Modes and Its Effect on the Calibration Bias in S Gas Detection by Gas Chromatography)

  • 김기현;최여진
    • 한국대기환경학회지
    • /
    • 제21권2호
    • /
    • pp.269-274
    • /
    • 2005
  • In this work, analytical bias arising from the gas chromatographic determination of sulfur compounds was evaluated by the application of direct loop injection method to the GC/PFPD detection of four sulfur compounds including H$_{2}$S, CH$_{3}$SH, DMS, and DMDS. For the proper evaluation of analytical uncertainties involved in GC calibration, we employed two comparative techniques of calibration at fxed concentration injection (CFCI) vs calibration at fixed volume injection (CFVI) method. The results of our study indicate that CFCI method exhibits very poor sensitivity due to the matrix effect with varying injection volumes. On the other hand, as CFVI method overcomes such limitation, it can be used to obtain very accurate quantification of S compounds at their high concentration levels above a few to a few tens ppb.

Improvement of Field Calibration of a Transmissometer for Visibility Measurement

  • Kim Kyung W.;Kim Young J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제21권E2호
    • /
    • pp.49-56
    • /
    • 2005
  • A long-path transmissometer is one of the optical instruments widely used to measure atmospheric light extinction coefficient without enclosing a light beam and perturbing aerosols. Over the past two decades, a number of measurements have been carried out using the long-path transmissometer manufactured by OPTEC, Inc. Calibration of the transmissometer should be performed when any component of the transmissometer system is interchanged or installation condition is changed. For a better calibration of the transmissometer, application of a modified calibration method for the existing neutral density (ND)-filter method was recommended for the computation of the atmospheric transmittance using model MODTRAN 4 in this study. It was revealed that the measured light extinction coefficient from the transmissometer which was calibrated using the existing ND-filter method could be overestimated due to the assumption of the atmospheric transmittance suggested by OPTEC, Inc. The uncertainty of the measured light extinction coefficient from the transmissometer calibrated based on the modified ND-filter method was calculated to be approximately $13Mm^{-1}$.

질량측정에 의한 우량계 표준교정시스템 개발 (Development of Standard Calibration System for the Rain Gauges by Weighting Method)

  • 신강욱;홍성택
    • 제어로봇시스템학회논문지
    • /
    • 제12권8호
    • /
    • pp.818-823
    • /
    • 2006
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the uncertainty for the rainfall intensity and obtained useful result through the proposed calibration method.

지자기 센서의 온라인 왜곡 보정기법 (On-line Magnetic Distortion Calibration Method for a Magnetometer)

  • 김태연;소창주;유준
    • 제어로봇시스템학회논문지
    • /
    • 제18권9호
    • /
    • pp.819-822
    • /
    • 2012
  • This paper describes an on-line magnetic distortion calibration procedure for a magnetometer. The horizontal magnetic field is calculated through the earth magnetic field sensed by 3-axes magnetometer. The ellipse equation is derived from a set of horizontal magnetic field data using least square method and calibration parameters are determined. The calibration process is performed iteratively until parameters are not renewed, and experimental results show the effectiveness of the devised method.

정방형 교정 frame을 이용한 카메라의 교정 파라메타 추정에 관한 연구 (A study on the calibration parameter estimation of camera using square calibration frame)

  • 최성구;노도환
    • 전자공학회논문지B
    • /
    • 제33B권7호
    • /
    • pp.127-137
    • /
    • 1996
  • The 3-dimensional measurement using stereo vision system must achieve a camera calibration. So far, the 3-dimensional calibration technique that uses two-dimensional grid papar and a non-linear least square method has been developed and tested. But, this method is inefficient because it has many calculation procedure and a non-linear analysis. Therefore, this paper proposed the projective geometric method which produced the calibration parameter by vanishing point. The vanishing point is producted by a cross ratio and a parallel line pairs. The results of the computer simulation show utility of the proposed method.

  • PDF

Absolute Radiometric Calibration for KOMPSAT-3 AEISS and Cross Calibration Using Landsat-8 OLI

  • Ahn, Hoyong;Shin, Dongyoon;Lee, Sungu;Choi, Chuluong
    • 한국측량학회지
    • /
    • 제35권4호
    • /
    • pp.291-302
    • /
    • 2017
  • Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remotely sensed data. This paper presents absolute radiometric calibration of the KOMPSAT-3 (KOrea Multi Purpose SATellite-3) and cross calibration using the Landsat-8 OLI (Operational Land Imager). Absolute radiometric calibration was performed using a reflectance-based method. Correlations between TOA (Top Of Atmosphere) radiances and the spectral band responses of the KOMPSAT-3 sensors in Goheung, South Korea, were significant for multispectral bands. A cross calibration method based on the Landsat-8 OLI was also used to assess the two sensors using near simultaneous image pairs over the Libya-4 PICS (Pseudo Invariant Calibration Sites). The spectral profile of the target was obtained from EO-1 (Earth Observing-1) Hyperion data over the Libya-4 PICS to derive the SBAF (Spectral Band Adjustment Factor). The results revealed that the TOA radiance of the KOMPSAT-3 agree with Landsat-8 within 5.14% for all bands after applying the SBAF. The radiometric coefficient presented here appears to be a good standard for maintaining the optical quality of the KOMPSAT-3.

효율적인 각/가속도 센서 오차 보상을 위한 3 축 각도 측정 장치의 개발 및 활용 (Development and Application of Three-axis Motion Rate Table for Efficient Calibration of Accelerometer and Gyroscope)

  • 곽환주;황정문;김정한;박귀태
    • 제어로봇시스템학회논문지
    • /
    • 제18권7호
    • /
    • pp.632-637
    • /
    • 2012
  • This paper introduces a simple and efficient calibration method for three-axis accelerometers and three-axis gyroscopes using three-axis motion rate table. Usually, the performance of low cost MEMS-based inertial sensors is affected by scale and bias errors significantly. The calibration of these errors is a bothersome problem, but the previous calibration methods cannot propose simple and efficient method to calibrate the errors of three-axis inertial sensors. This paper introduces a new simple and efficient method for the calibration of accelerometer and gyroscope. By using a three-axis motion rate table, this method can calibrate the accelerometer and gyroscope simultaneously and simply. Experimental results confirm the performance of the proposed method.

자동차 안전운전 보조 시스템에 응용할 수 있는 카메라 캘리브레이션 방법 (Camera Calibration Method for an Automotive Safety Driving System)

  • 박종섭;김기석;노수장;조재수
    • 제어로봇시스템학회논문지
    • /
    • 제21권7호
    • /
    • pp.621-626
    • /
    • 2015
  • This paper presents a camera calibration method in order to estimate the lane detection and inter-vehicle distance estimation system for an automotive safety driving system. In order to implement the lane detection and vision-based inter-vehicle distance estimation to the embedded navigations or black box systems, it is necessary to consider the computation time and algorithm complexity. The process of camera calibration estimates the horizon, the position of the car's hood and the lane width for extraction of region of interest (ROI) from input image sequences. The precision of the calibration method is very important to the lane detection and inter-vehicle distance estimation. The proposed calibration method consists of three main steps: 1) horizon area determination; 2) estimation of the car's hood area; and 3) estimation of initial lane width. Various experimental results show the effectiveness of the proposed method.

배열안테나 시스템의 평균 내부순환 안테나 교정 방법 (Average Internal Loop-back Antenna Calibration Method for Array Antenna Systems)

  • 이일신;김현수;이홍원;정재학
    • 한국통신학회논문지
    • /
    • 제34권2A호
    • /
    • pp.139-146
    • /
    • 2009
  • 본 논문은 TDD(Time Division Duplex) 배열안테나 시스템에서 빔형성을 할 때와 송신 전력을 할당하는 경우에 필요한 송수신 RF 단의 진폭과 위상 오차를 교정하는 평균자동내부순환교정 방법을 제안한다. 제안된 기술은 기존의 부가적인 내부 신호발생기나 외부의 기준신호를 필요로 하지 않으며 송수신기 내부의 스위치와 커플러를 이용하여 배열안테나 RF단을 교정할 수 있는 방법이다. 또한 한 개의 송수신 RF단을 사용한 교정에 의한 오차를 줄이기 위해서 평균송수신 RF단 교정 방법을 제안하였다. 전산모의실험을 통해 DOA(Direction of Arrival)추정 빔형성 알고리즘이 송수신 RF단 교정에 의해 정확한 빔형성이 되는 것을 보였고 송신 전력 할 당시에도 제안된 교정에 의해 비트오류율이 낮아짐을 보였다.