• Title/Summary/Keyword: Calibration Factor

Search Result 435, Processing Time 0.026 seconds

Sensitivity Enhancement of a Hot-Wire Anemometer by Changing Overheat Ratio with Velocity (유속에 따른 열선의 과열비 조정을 통한 열선유속계의 감도향상에 관한 연구)

  • ;;Kauh, S. K.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2678-2689
    • /
    • 1995
  • In this study, a new hot-wire anemometer which has greater sensitivity than that of a constant temperature anemometer (CTA) was proposed. In contrast to CTA, the wire working resistance of the new anemometer increases with flow velocity, that is, the operating mode of the wire becomes variable temperature. The variable temperature anemometer(VTA) was made by substituting a voltage controlled variable resistor such as photoconductive cell or transistor for one of the resistors in the bridge. By positively feeding back the bridge top signal to the input side of these electronic components, the wire overheat ratio could be increased with velocity automatically. Static response analyses of the VTA, constant voltage anemometer (CVA) and CTA were made in detail and calibration experiments were performed to validate the proposed operating principle. The wire operating resistance of the CVA decreases with velocity and this leads to lower sensitivity than that of a CTA. But the sensitivity of the newly proposed VTA is superior to that of a CTA, since the wire overheat ratio increases with velocity. Consequently, it is found that the major factor that is responsible for large sensitivity of a VTA is not the working resistance itself but the change of the wire working resistance with velocity.

Experimental Evaluation of Percussion Performance for Rock-Drill Drifter

  • Seo, Jaho;Park, Jin-Sun;Kim, Heungsub;Noh, Dae Kyung
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Purpose: The objective of this study was to understand the operating mechanism of the rock-drill drifter, to explain how to setup an experimental test system and measure the strain of the drifter's rod, and to evaluate the drifter's performance with respect to the impact energy and blow frequency. Methods: The structure of the rock-drill drifter and its operating principle regarding the impact process were analyzed. Static calibration was carried out to calculate the correction factor using a drifter rod as the first step of the experimental test. The impact energy and blow frequency were then calculated based on strain measurements of the drifter's rod. Results: Experimental results showed that the tested drifter elicited a blow frequency of 3330 BPM (Blows Per Minute) and generated impact energy of 170 J/blow. This indicates that the drifter elicits a higher percussion speed and results in a lower impact energy compared to the hydraulic breaker at the same input power. Conclusions: The study proposed methodologies that deal with the experimental setup and the evaluation of the performance of the rock-drill drifter. These methodologies can be extensively used for validating and improving the percussion performance of the drilling equipment.

Uncertainty in Determination of Menthol from Mentholated Cigarette (담배 중 멘톨 분석에 대한 불확도 측정)

  • 장기철;이운철;백순옥;한상빈
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • This study was carried out to evaluate the uncertainty in the analysis of menthol content from the mentholated cigarette. Menthol in the sample cigarette was extracted with methanol containing an anethole as an internal standard, and then analyzed by gas chromatography. As the sources of uncertainty associated with the analysis of menthol, were the following points tested, such as the weighing of sample, the preparation of extracting solution, the pipetting of extracting solution into the sample, the preparation of standard solution, the precision of GC injections for standard & sample solution, the GC response factor of standard solution, the reproducibility of menthol analysis, and the determination of water content in tobacco, etc. For calculating the uncertainties, type A of uncertainty was evaluated by the statistical analysis of a series of observation, and type B by the information based on supplier's catalogue and/or certificated of calibration. Sources of uncertainty were subsequently included and mathematically combined with the uncertainty arising from the assessment of accuracy to provide the overall uncertainty. It was shown that the main source of uncertainty came from the errors in the reproducibility of menthol and water determination, the purity of menthol reference material in the preparation of standard solution, and the precision of GC injections for sample solution. The errors in sample weighing and volume measurement contributed relatively little to the overall uncertainty. The expanded uncertainty in the mentholated cigarettes, Korean and American brand, at 0.95 level of statistical confidence was $\pm$0.06 and $\pm$0.07 mg/g for a menthol content of 1.89 and 2.32 mg/g, respectively.

  • PDF

Visual Fatigue Reduction Based on Depth Adjustment for DIBR System

  • Liu, Ran;Tan, Yingchun;Tian, Fengchun;Xie, Hui;Tai, Guoqin;Tan, Weimin;Liu, Junling;Xu, Xiaoyan;Kadri, Chaibou;Abakah, Naana
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.4
    • /
    • pp.1171-1187
    • /
    • 2012
  • A depth adjustment method for visual fatigue reduction for depth-image-based rendering (DIBR) system is proposed. One important aspect of the method is that no calibration parameters are needed for adjustment. By analyzing 3D image warping, the perceived depth is expressed as a function of three adjustable parameters: virtual view number, scale factor and depth value of zero parallax setting (ZPS) plane. Adjusting these three parameters according to the proposed parameter modification algorithm when performing 3D image warping can effectively change the perceived depth of stereo pairs generated in DIBR system. As the depth adjustment is performed in simple 3D image warping equations, the proposed method is facilitative for hardware implementation. Experimental results show that the proposed depth adjustment method provides an improvement in visual comfort of stereo pairs as well as generating comfortable stereoscopic images with different perceived depths that people desire.

Extended Compliance Solution of ESET Specimen for Thermal fatigue Crack Growth Test (열피로 균열성장시험을 위한 ESET 시편의 확장된 컴플라이언스 해)

  • Lee, Ho-Jin;Kim, Maan-Won;Lee, Bong-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.62-67
    • /
    • 2005
  • An eccentrically-loaded single edge crack tension specimen (ESET) is similar to a compact tension(CT) specimen loaded in tension-tension. The standard ESET specimen exhibits advantages over other types of cracked specimen, such as n, single-edge crack, and middle-crack tension specimen. The details of ESET specimen configuration, test procedure, and calculations are described in ASTM E647 standard. However, a difficulty in attaching COD gage to the knife-edge on the front foe of the specimen can be found when the size of ESET specimen is small for rapid cooling and heating in thermal fatigue testing. The finite element analysis is performed for the ESET specimen with projected knife-edge on the front foe and a crack-length-compliance equation is suggested for the new specimen configuration. Calibration test are conducted with 347 stainless steel to compare the measured crack length with the calculated crack length from the suggested compliance expression. The test results showed good agreements with those of analysis.

Mineral Admixture Factors Affecting Rheological Properties of Cement Paste (시멘트 페이스트의 레올로지 특성에 미치는 혼화재 변수의 영향)

  • Heo Young-Sun;Hwang Yin-Sung;Shin Hyun-Sup;Yoon Seob;Lee Gun-Cheol;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.57-61
    • /
    • 2005
  • Cement paste is originally the basic material and crucial factor consisting concrete. This study investigates the relationship between flow apparatuses, which are ring flow(R-F), flow cone(F-C) and mini slump(M-S), in order to estimate the fluidity of cement Paste. For quantitatively evaluating the measured data this study also investigated the calibration of the rheology consistent, such as yield value and plastic viscosity, of cement paste using viscometer For this purpose the present work discussed the influence of 3 type of ordinary portland cement with different companies, affecting the fluidity of cement paste. and it also demonstrated the influence of the various kinds of mineral admixtures, such as fly ash(FA), blast furnace slag(BS) and silica fume(SF) and that of incorporating ratio. The author concluded that using R-F apparatus is the most effective flow test method of cement paste and it is exactly proportional to other apparatus' rheological properties.

  • PDF

Development of a Dispersion Analysis Program for the Liquid Rocket Engine and its Application (액체로켓 엔진 성능 분산해석 프로그램의 개발 및 응용)

  • Park, Soon-Young;Nam, Chang-Ho;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.63-69
    • /
    • 2011
  • In this study, we developed a dispersion analysis program of the gas-generator cycle liquid propellant rocket engine by expanding the mode analysis software(GEMAT). The performance dispersions of an engine that are arisen from the internal dispersion factors of engine's sub-components were formulated and solved to find the effects of each dispersion factor. We were also able to present the calculation method to find the required pressure margin for the compensation of those dispersion to satisfy the required performances of engine. Using this method, we could propose a novel procedure of compensating during the ground firing test which would induce the performance improvement by lessening the pumps discharge pressures or augmenting the combustion chamber pressure.

Tempereture Dependent Dielectric Relaxation Study of Aniline in Dimethylsulphoxide and Dimethlformamide Using Time Domain Technique (시간분해기법을 이용한 디메틸 술폭사이드와 디메틸 포름아미드-아닐린용액에서 온도의존 유전이완에 관한 연구)

  • Chaudhari, Ajay;Patil, C.S.;Shankarwar, A.G.; Arbad, B.R.;Mehrotra, S.C.
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.3
    • /
    • pp.201-207
    • /
    • 2001
  • The dielectric relaxation study for aniline-dimethylsulphoxide (DMSO) and aniline-dim.ethylformamide(DMF) has been carried out using the Time domain reflectometry (TDR) technique, at different temperature and concentrations, in the frequency range of 10 MHz to 10 GHz. The dielectric parameters viz. static permittivity, relaxation time, the Kirkwood correlation factor, excess permittivity, excess inverse relaxation time and thermodynamic parameters have been obtained. The calibration method based on least squares fit method has been used. The dielectric parameters show systematic change with temperature and concentrations.

  • PDF

Bone Density Spatial Distribution of Radiation Dose Measurement (양방사선 골밀도 측정 장치의 공간산란선량분포측정)

  • Kim, Seon-Chil;Won, Do-Yeon;Park, Chang-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF

A 4x Time-Domain Interpolation 6-bit 3.4 GS/s 12.6 mW Flash ADC in 65 nm CMOS

  • Liu, Jianwei;Chan, Chi-Hang;Sin, Sai-Weng;U, Seng-Pan;Martins, Rui Paulo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.395-404
    • /
    • 2016
  • A 6-bit 3.4 GS/s flash ADC in a 65 nm CMOS process is reported along with the proposed 4x time-domain interpolation technique which allows the reduction of the number of comparators from the conventional $2^N-1$ to $2^{N-2}$ in a N-bit flash ADC. The proposed scheme effectively achieves a 4x interpolation factor with simple SR-latches without extra clocking and calibration hardware overhead in the interpolated stage where only offset between the $2^{N-2}$ comparators needs to be calibrated. The offset in SR-latches is within ${\pm}0.5$ LSB in the reported ADC under a wide range of process, voltage supply, and temperature (PVT). The design considerations of the proposed technique are detailed in this paper. The prototype achieves 3.4 GS/s with 5.4-bit ENOB at Nyquist and consumes 12.6 mW power at 1 V supply, yielding a Walden FoM of 89 fJ/conversion-step.