• Title/Summary/Keyword: Calibration Factor

Search Result 436, Processing Time 0.027 seconds

Measurement of Radon-222 Exhalation Rate from Building Materials by Using CR-39 Radon Cup (CR-39 라돈컵을 이용한 국산 전축자재의 라돈-222 방출율 측정)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.15-24
    • /
    • 1991
  • Radon-222 exhalation rate from several domestic building materials were experimentally measured by using radon cup method, in which a CR-39 plastic is used as a passive radon detector. The radon detection factor of CR-39 detector determined in a series of calibration experiments was $0.164{\pm}0.005(tracks\;cm^{-2}/Bq\;d\;m^{-3})$, which is consistent with those reported by other investigators. The radon exhalation rates of several building materials (brick, red brick, concrete block, granite plate, concrete floor and wall) ranges from $6.8{\times}10^{-6}\;(granite plate)\;to\;75.0{\times}10^{-6}Bq/m^2-sec(brick)$ with the increasing order of granite plate, red brick, concrete wall, concrete block, concrete floor and brick. It showed that the CR39 radon cup can be efficiently utilized in measuring the radon-222 gas exhalation rate from building materials.

  • PDF

An experimental study on the fretting fatigue crack behaviour of A12024-T4 (A12024-T4의 프레팅 피로균열거동에 관한 실험적 연구)

  • Lee, Bong-Hun;Lee, Sun-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.511-518
    • /
    • 1997
  • The technique of fretting fatigue test was developed and fretting fatigue tests of A12024-T4 were conducted under several conditions. The newly developed calibration methods for measuring surface contact tractions showed good linearity and repeatability. The plate type specimen to which tow bridge type pads were attached and vision system was used to observe the crack behaviour. The oblieque cracks appeared in the early stage of crack growth and they became mode I cracks as they grow about 1 mm. The mode I transition points were found to be longer when surface tractions are higher or bulk stress is lower. Before the crack becomes mode I crack, 'well point' where crack grow about rate is minimum, was detected under every experimental condition. The crack behaviour was found to be affected by surface tractions, contact area, bulk stress. It was also found that partial slip and stick condition is most detrimental and the crack starts from the boundary of stick and slip. For gross slip crack started at the outside edge of pad. After crack mode transition, fretting fatigue cracks showed almost same behaviour of plain mode I fatigue cracks. Equivalent stress intensity factor was used to analyze the behaviour of fretting fatigue cracks and it was found that stress intensity factors can be applied to fretting fatigue cracks.

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF

Weigh-in-Motion load effects and statistical approaches for development of live load factors

  • Yanik, Arcan;Higgins, Christopher
    • Structural Engineering and Mechanics
    • /
    • v.76 no.1
    • /
    • pp.1-15
    • /
    • 2020
  • The aim of this paper is to simply present live load factor calculation methodology formulation with the addition of a simple new future load projection procedure to previously proposed two methods. For this purpose, Oregon Weigh-in-Motion (WIM) data were used to calculate live load factors by using WIM data. These factors were calculated with two different approaches and by presenting new simple modifications in these methods. A very simple future load projection method is presented in this paper. Using four different WIM sites with different average daily truck traffic (ADTT) volume, and all year data, live load factors were obtained. The live load factors, were proposed as a function of ADTT. ADTT values of these sites correspond to three different levels which are approximately ADTT= 5,000, ADTT = 1,500 and ADTT ≤ 500 cases. WIM data for a full year were used from each site in the calibration procedure. Load effects were projected into the future for the different span lengths considering five-year evaluation period and seventy-five-years design life. The live load factor for ADTT=5,000, AASHTO HS20 loading case and five-year evaluation period was obtained as 1.8. In the second approach, the methodology established in the Manual for Bridge Evaluation (MBE) was used to calibrate the live load factors. It was obtained that the calculated live load factors were smaller than those in the MBE specifications, and smaller than those used in the initial calibration which did not convert to the gross vehicle weight (GVW) into truck type 3S2 defined by AASHTO equivalents.

Development of Rutting Model for Asphalt Mixtures using Laboratory and Accelerated Pavement Testing (실내 및 포장가속시험를 이용한 아스팔트 혼합물의 소성변형 모형 개발)

  • Lee, Sang-Yum;Lee, Hyun-Jong;Huh, Jae-Won;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.79-89
    • /
    • 2008
  • The pavement performance model is the most important factor to determine the pavement life in the mechanistic-empirical pavement design guide (MEPDG). As part of Korean Pavement Research Program (KPRP), the Korean Pavement Design Guide (KPDG) is currently being developed based on mechanistic-empirical principle. In this paper, the rutting prediction model of asphalt mixtures, one of the pavement performance model, has been developed using triaxial repeated loading testing data. This test was conducted on various types of asphalt mixtures for investigating the rutting characteristics by varying with the temperature and air void. The calibration process was made for the coefficients of rutting prediction model using the accelerated pavement testing data. The accuracy of prediction model can be increased when by considering the effect of individual rutting properties of materials rather than shear stresses with depths.

  • PDF

Nomogram building to predict dyslipidemia using a naïve Bayesian classifier model (순수 베이지안 분류기 모델을 사용하여 이상지질혈증을 예측하는 노모 그램 구축)

  • Kim, Min-Ho;Seo, Ju-Hyun;Lee, Jea-Young
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.4
    • /
    • pp.619-630
    • /
    • 2019
  • Dyslipidemia is a representative chronic disease affecting Koreans that requires continuous management. It is also a known risk factor for cardiovascular disease such as hypertension and diabetes. However, it is difficult to diagnose vascular disease without a medical examination. This study identifies risk factors for the recognition and prevention of dyslipidemia. By integrating them, we construct a statistical instrumental nomogram that can predict the incidence rate while visualizing. Data were from the Korean National Health and Nutrition Examination Survey (KNHANES) for 2013-2016. First, a chi-squared test identified twelve risk factors of dyslipidemia. We used a naïve Bayesian classifier model to construct a nomogram for the dyslipidemia. The constructed nomogram was verified using a receiver operating characteristics curve and calibration plot. Finally, we compared the logistic nomogram previously presented with the Bayesian nomogram proposed in this study.

Head tracking system using image processing (영상처리를 이용한 머리의 움직임 추적 시스템)

  • 박경수;임창주;반영환;장필식
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.1-10
    • /
    • 1997
  • This paper is concerned with the development and evaluation of the camera calibration method for a real-time head tracking system. Tracking of head movements is important in the design of an eye-controlled human/computer interface and the area of virtual environment. We proposed a video-based head tracking system. A camera was mounted on the subject's head and it took the front view containing eight 3-dimensional reference points(passive retr0-reflecting markers) fixed at the known position(computer monitor). The reference points were captured by image processing board. These points were used to calculate the position (3-dimensional) and orientation of the camera. A suitable camera calibration method for providing accurate extrinsic camera parameters was proposed. The method has three steps. In the first step, the image center was calibrated using the method of varying focal length. In the second step, the focal length and the scale factor were calibrated from the Direct Linear Transformation (DLT) matrix obtained from the known position and orientation of the camera. In the third step, the position and orientation of the camera was calculated from the DLT matrix, using the calibrated intrinsic camera parameters. Experimental results showed that the average error of camera positions (3- dimensional) is about $0.53^{\circ}C$, the angular errors of camera orientations are less than $0.55^{\circ}C$and the data aquisition rate is about 10Hz. The results of this study can be applied to the tracking of head movements related to the eye-controlled human/computer interface and the virtual environment.

  • PDF

Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test (엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석)

  • Yang, In-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

  • Nam, Uk-Won;Lim, Chang Hwy;Lee, Jae Jin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Park, Youngsik;Kim, Hyun Ok;Moon, Myungkook;Kim, Sunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • Tissue equivalent proportional counter (TEPC) can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS). The prototype TEPC which can simulate a 2 ${\mu}m$ of the site diameter for micro-dosimetry has been tested with a standard alpha source ($^{241}Am$, 5.5 MeV). Also, the calibration of the TEPC was performed by the $^{252}Cf$ neutron standard source in Korea Research Institute of Standards and Science (KRISS). The determined calibration factor was $k_f=3.59{\times}10^{-7}$ mSv/R.

Development of Absolute Deformation Analysis System by Close-Range Photogrammetry (Close-Range Photogrammetry에 의한 절대변형해석 시스템의 개발)

  • 배연성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.2
    • /
    • pp.127-135
    • /
    • 2004
  • The calibration of lens to be used and the planning of photographing planning layout is very important to achieve the requested accuracy in the precision measurement by close-range photogrammetry. Establishment of absolute coordinate system is regarded as another important factor for the purpose of measuring absolute deformation of photogrammetric object. In this study, the following tasks were performed : (1) calibration of super-wide-angle lens or focal length 21mm fer close-range photographing used by 35mm metric camera, (2) development of the measuring system for monitoring of absolute deformation through periodic observation of small area, and, (3) application of this system to monitor the absolute deformation of surface of underwater structure in fixed cycle and to present the efficiency of the system.