Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

  • Received : 2013.05.11
  • Accepted : 2013.05.26
  • Published : 2013.06.15

Abstract

Tissue equivalent proportional counter (TEPC) can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS). The prototype TEPC which can simulate a 2 ${\mu}m$ of the site diameter for micro-dosimetry has been tested with a standard alpha source ($^{241}Am$, 5.5 MeV). Also, the calibration of the TEPC was performed by the $^{252}Cf$ neutron standard source in Korea Research Institute of Standards and Science (KRISS). The determined calibration factor was $k_f=3.59{\times}10^{-7}$ mSv/R.

Keywords

References

  1. Alexakhin R, Cousins C, Gonza'lez A, Menzel H, Pentreath R, et al., The 2007 Recommendations of the International Commission on Radiological Protection, ICRP 103 (2007).
  2. Burmeister J, Kota C, Maughan RL, Paired miniature tissueequivalent proportional counters for dosimetry in high flux epithermal neutron capture therapy beams, NIM, 422, 606-610 (1999). https://doi.org/10.1016/S0168-9002(98)00968-1
  3. Dietze G, Menzel H, Bühler G, Calibration of Tissue- Equivalent Proportional Counters Used as Radiation Protection Dosemeters, RPD, 9, 245-249 (1984).
  4. Keith J, Badhwar G, Lindstrom D, Neutron spectrum and dose-equivalent in shuttle flights during solar maximum, NTRM, 20, 41-47 (1992).
  5. Kunz A, Pihet P, Arend E, Menzel HG, An easy-to-operate portable pulse-height analysis system for area monitoring with TEPC in radiation protection, NIM, 299, 696-701 (1990). https://doi.org/10.1016/0168-9002(90)90872-4
  6. Lindborg L, Bartlett D, Beck P, McAulay I, Schnuer K, et al., Cosmic Radiation Exposure of Aircraft Crew, European Communities, Radiation Protection 140 (2004).
  7. Mulville D, Electrical grounding architecture for unmanned space craft, NASA Technical Handbook, NASA-HDBK- 4001 (1998).
  8. Rossi H, Rosenzweig W, A Device for the Measurement of Dose as a Function of Specific Ionisation, Radiology, 64, 404-411 (1955). https://doi.org/10.1148/64.3.404
  9. Sakaguchi T, Doke T, Hasebe N, Hayashia T, Kashiwagic T, et al., LET distribution measurement with a new realtime radiation monitoring device-III onboard the Space Shuttle STS-84, NIM, 437, 75-87 (1999). https://doi.org/10.1016/S0168-9002(99)00652-X
  10. Taddei P, Borak T, Guetersloh S, Gersey B, Zeitlin C, et al., The response of a spherical tissue-equivalent proportional counter to different heavy ions having similar velocities, RM, 4179, 1227-1234 (2006).
  11. Vetter R, Baker E, Bartlett D, Borak T, Langhorst S, et al., Operational radiation safety program for astronauts in low-earth orbit, a basic frame work, NCRP No.142 (2002).

Cited by

  1. Measurement of Linear Energy Spectra for 135 MeV/u Carbon Beams in HIMAC Using Prototype TEPC vol.23, pp.3, 2014, https://doi.org/10.5369/JSST.2014.23.3.197
  2. Calibration of TEPC for CubeSat Experiment to Measure Space Radiation vol.32, pp.2, 2015, https://doi.org/10.5140/JASS.2015.32.2.145