• 제목/요약/키워드: Calibration

검색결과 6,284건 처리시간 0.029초

Detection of Calibration Patterns for Camera Calibration with Irregular Lighting and Complicated Backgrounds

  • Kang, Dong-Joong;Ha, Jong-Eun;Jeong, Mun-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.746-754
    • /
    • 2008
  • This paper proposes a method to detect calibration patterns for accurate camera calibration under complicated backgrounds and uneven lighting conditions of industrial fields. Required to measure object dimensions, the preprocessing of camera calibration must be able to extract calibration points from a calibration pattern. However, industrial fields for visual inspection rarely provide the proper lighting conditions for camera calibration of a measurement system. In this paper, a probabilistic criterion is proposed to detect a local set of calibration points, which would guide the extraction of other calibration points in a cluttered background under irregular lighting conditions. If only a local part of the calibration pattern can be seen, input data can be extracted for camera calibration. In an experiment using real images, we verified that the method can be applied to camera calibration for poor quality images obtained under uneven illumination and cluttered background.

적외채널 기본 복사보정 결과를 이용한 기하보정 처리의 정확도 분석 (Analysis of Geometric Calibration Accuracy using the Results from IR Channel Nominal Radiometric Calibration)

  • 서석배;권은주;진경욱
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.147-155
    • /
    • 2013
  • 천리안위성 기상탑재체 적외채널의 복사보정에서는 기본 복사보정식을 기반으로 다섯 개의 알고리즘이 추가되어 있다. 일반적으로 기하보정은 복사보정 이후 수행하므로, 복사보정 완료시각은 기하보정 처리의 시작시각을 결정한다. 본 논문에서는 기하보정 처리의 시작시각을 앞당기는 방법을 제안하기 위해서, 기본 복사보정 및 정밀 복사보정(기본 복사보정에 다섯 개의 알고리즘 추가) 결과를 입력으로 수행한 기하보정 처리의 정확도를 비교 분석한 내용을 정리하였다. 처리 속도가 빠른 기본 복사보정의 결과와 정확한 복사보정 값을 포함하는 정밀복사보정의 결과를 입력으로 각각의 기하보정 처리의 정확도를 분석하는 실험을 수행하였고, 두 경우 모두 기하보정 정확도 요구사항을 만족시킴을 검증하였다. 따라서 기하보정 처리 속도를 향상시키기 위해서, 기본 복사보정식으로 생성된 결과를 기하보정 처리의 입력으로 사용할 수 있음을 확인하였다.

대형 평판 디스플레이의 정밀 정렬을 위한 캘리브레이션 기술 (Calibration Technology for Precise Alignment of Large Flat Panel Displays)

  • 홍준호;신동원
    • 한국기계가공학회지
    • /
    • 제21권3호
    • /
    • pp.100-109
    • /
    • 2022
  • In this study, calibration technology that increases the alignment accuracy in large flexible flat panels was studied. For precise of calibration, a systematization of the calibration algorithm was established, and a calibration correction technique was studied to revise calibration errors. A coordinate systems of camera and UVW stage was established to get the global position of the mark, and equations for translational and rotational calibration were systematically derived based on geometrical analysis. Correction process for the calibration data was carried, and alignment experiments were performed sequentially in cases of the presence or absence of calibration-correction. Alignment results of both calibration correction and non-calibration correction showed accuracy performance less than 1㎛. On the other hand, the standard deviation in calibration-correction is smaller than non-calibration correction. Therefore, calibration correction showed improvement of the alignment repeatability.

In-Process Relative Robot WorkCell Calibration

  • Wang, Jianjun;Sun, Yunquan;Gan, zhongxue
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.269-272
    • /
    • 2003
  • Industry is now seeing a dramatic increase in robot simulation and off-line programming. In order to use off-line programming effectively, the simulated workcell has to be identical to the real workcell. This requires an efficient and accurate method for the workcell calibration. Currently used techniques in the industry, however, are typically time-consuming, expensive and therefore not suitable for in-process application. This is because most of these techniques are based on the so-called “absolute calibration” method. In contrast to absolute method, relative calibration only measures the difference of an interested object relative to a standard reference. Owing to the small measurement range requirement, relative calibration method is very cheap and can achieve very high accuracy. In this paper the relative method is applied to calibrate an entire grinding workcell. Linear gauge is the only measurement device used. This workcell calibration includes tool center point (TCP) calibration and work object frame calibration. Due to the efficiency of the calibration algorithm and the simplicity of the calibration setup, the described calibration procedure can be done in process.

  • PDF

Boresight calibration을 이용한 외부표정요소 산출에 관한 연구 (A study on the transformation of EO parameters using Boresight calibration)

  • 박수영;윤여상;김준철;정주권;주영은
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2003년도 추계학술발표회 논문집
    • /
    • pp.129-134
    • /
    • 2003
  • Mobile Mapping System needs system calibration of multi sensors. System calibration is defined as determination of spatial and rotational offsets between the sensors. Especially, EO parameters of GPS/INS require knowledge of the calibration to camera frame. The calibration parameters must be determined with the highest achievable accuracy in order to get 3D coordinate points in stereo CCD images. This study applies Boresight calibration for the calibration between GPS/INS and camera, and estimates the Performance of the calibration.

  • PDF

Array Calibration for CDMA Smart Antenna Systems

  • Kyeong, Mun-Geon;Park, Hyung-Geun;Oh, Hyun-Seo;Jung, Jae-Ho
    • ETRI Journal
    • /
    • 제26권6호
    • /
    • pp.605-614
    • /
    • 2004
  • In this paper, we investigate array calibration algorithms to derive a further improved version for correcting antenna array errors and RF transceiver errors in CDMA smart antenna systems. The structure of a multi-channel RF transceiver with a digital calibration apparatus and its calibration techniques are presented, where we propose a new RF receiver calibration scheme to minimize interference of the calibration signal on the user signals. The calibration signal is injected into a multi-channel receiver through a calibration signal injector whose array response vector is controlled in order to have a low correlation with the antenna response vector of the receive signals. We suggest a model-based antenna array calibration to remove the antenna array errors including mutual coupling errors or to predict the element patterns from the array manifold measured at a small number of angles. Computer simulations and experiment results are shown to verify the calibration algorithms.

  • PDF

On-Site vs. Laboratorial Implementation of Camera Self-Calibration for UAV Photogrammetry

  • Han, Soohee;Park, Jinhwan;Lee, Wonhee
    • 한국측량학회지
    • /
    • 제34권4호
    • /
    • pp.349-356
    • /
    • 2016
  • This study investigates two camera self-calibration approaches, on-site self-calibration and laboratorial self-calibration, both of which are based on self-calibration theory and implemented by using a commercial photogrammetric solution, Agisoft PhotoScan. On-site self-calibration implements camera self-calibration and aerial triangulation by using the same aerial photos. Laboratorial self-calibration implements camera self-calibration by using photos captured onto a patterned target displayed on a digital panel, then conducts aerial triangulation by using the aerial photos. Aerial photos are captured by an unmanned aerial vehicle, and target photos are captured onto a 27in LCD monitor and a 47in LCD TV in two experiments. Calibration parameters are estimated by the two approaches and errors of aerial triangulation are analyzed. Results reveal that on-site self-calibration excels laboratorial self-calibration in terms of vertical accuracy. By contrast, laboratorial self-calibration obtains better horizontal accuracy if photos are captured at a greater distance from the target by using a larger display panel.

초음파 도플러 유속계 교정 시설 현황 (Analysis of Calibration Facilities for Acoustic Doppler Current Profilers (ADCPs))

  • 이정한;황근춘;김은수
    • Ocean and Polar Research
    • /
    • 제33권2호
    • /
    • pp.171-183
    • /
    • 2011
  • Despite technological developments and application advances of Acoustic Doppler Current Profilers (ADCPs), no standard procedure has been adopted or accepted for calibration of ADCPs. Limitations of existing facilities for calibrating ADCPs, the complexity of ADCP instruments, and rapid changes in ADCP technology are some of the reasons why a standard procedure has not been adopted. However, there is increasing realization of the need for effective Quality Assurance (QA) and as part of that the importance of standardized calibration. In this study, the significance of calibration and QA plans for ADCPs is discussed and the calibration facilities for ADCPs at home and abroad are reported. Furthermore, the method for calibrating ADCPs using a towed car and its limitations are discussed. This study contributes to discussions surrounding the establishment of standard procedures for calibrating ADCPs and QA plans, and the construction of calibration facilities in the future.

레이저 섬광법에 의한 열확산계수 측정시 적외검출소자에서 실시간 온도보정이 미치는 영향 (Effects of the in-process calibration from IR detector for thermal diffusivity measurement by laser flash method)

  • 이원식;배신철
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.795-802
    • /
    • 1998
  • For measuring the thermal diffusivity by laser flash method, raw data have to be calibrated using temperature data. We have developed in-process calibration method and polynomial calibration in which thermal diffusivity can be calibrated during measuring, This method is different from existing temperature pre-process calibration method and exponential calibration having various source of error. Using this new calibration method, measurement accuracy was improved about 1∼2% compare to the value by the existing method. We also studied more accurate fitting curve as in Figure 4 was shown the result of measuring output characteristics of IR radiometer with temperature. As illustrated in data, in-process calibration method and polynomial calibration equation is proper than pre-process calibration method and exponential calibration.

  • PDF

Characteristics of COMS MI Radiometric Calibration

  • Cho, Young-Min
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.71-74
    • /
    • 2006
  • Communication Ocean Meteorological Satellite (COMS) is planned to be launched onto Geostationary Earth Orbit in 2008. The meteorological imager (MI) is one of COMS payloads and has 5 spectral channels to monitor meteorological phenomenon around the Korean peninsular intensively and of Asian-side full Earth disk periodically. The MI has on-board radiometric calibration capabilities called 'blackbody calibration' for infrared channels and 'space look' for infrared/visible channels, and radiometric response stability monitoring device called 'albedo monitor' for visible channel. Additionally the MI has on-board function called 'electrical calibration' for the check of imaging path electronics of both infrared and visible channels. The characterization of MI performance is performed to provide the pre-launch radiometric calibration data which will be used for in-orbit radiometric calibration with the on-board calibration outputs. The radiometric calibration of the COMS MI is introduced in the view point of instrument side in terms of in-orbit calibration devices and capabilities as well as the pre-launch calibration activities and expected outputs.

  • PDF