• 제목/요약/키워드: Calculate

검색결과 11,142건 처리시간 0.036초

Uncertainty and Sensitivity Analysis on A Biosphere Model

  • Park, Wan-Sou;Kim, Tae-Woon;Lee, Kun-Jai
    • Journal of Radiation Protection and Research
    • /
    • 제15권2호
    • /
    • pp.101-112
    • /
    • 1990
  • For the performance assessment of the radioactive waste disposal system (repository), a biosphere model is suggested. This biosphere model is intended to calculate the annual doses to man caused by the contaminated river water for eight pathways and four radionuclides. This model can also be applied to assess the radiological effects of contaminated well water. To account for the uncertainties on the model parameter values, parameter distributions are assigned to these model parameters. Then, Monte Carlo simulation method with Latin Hypercube sampling technique is used. Also, sensitivity analysis is performed by using the Spearman rank correlation coefficients. It is found that these methods are a very useful tool to treat uncertainties and sensitivities on the model parameter values and to analyze the biosphere model. A conversion factor is proposed to calculate the annual dose rate to humans arising from a unit radionuclide concentration in river water. This conversion factor allows for the substitution of the biosphere model in a probabilistic performance assessment computer code by one single variable.

  • PDF

표면 폭발하중 파라메타의 수정 산정식 (A Modified Equation of Parameter of Surface Blast Load)

  • 전두진;김기태;한상을
    • 한국공간구조학회논문집
    • /
    • 제17권3호
    • /
    • pp.75-82
    • /
    • 2017
  • The Kingery-Bulmash equation is the most common equation to calculate blast load. However, the Kingery-Bulmash equation is complicated. In this paper, a modified equation for surface blast load is proposed. The equation is based on Kingery-Bulmash equation. The proposed equation requires a brief calculation process, and the number of coefficients is reduced under 5. As a result, each parameter obtained by using the modified equation has less than 1% of error range comparing with the result by using Kingery-Bulmash equation. The modified equation may replace the original equation with brief process to calculate.

A Simplified Method to Calculate the EMF Characteristics of Multi-disk Axial-gap PM Motor using 2-D & 3-D FEM

  • Kim, Young-Kwan;Lee, Ju
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.34-39
    • /
    • 2008
  • The purpose of this paper is characteristic analysis of multi-disk axial-gap pm motor for turbo compressor. The axial-gap permanent magnet motor has shown a growing interest in high-speed application for its high-efficiency, compact size and low vibration characteristics due to core-less structure. To achieve high-power, the axial-gap PM motor has multi-disk structure of stator and rotor disk. Because of its complicated magnetic flux path, it is not easy to calculate a dynamic characteristics using finite element analysis. In this paper, the simplified 2-D unfolded model to predict EMF characteristic is presented. To verify thesuggested 2-D unfolded model analysis of back-EMF characteristic was calculated and compared 3-D finite element. Finally the proposed method is verified by experimental results and shows good agreement with test results.

프로니해석법을 이용한 공진 주파수 검출 알고리즘 (Oscillation Frequency Detecting Technique for Transmission Line Protection using Prony's Analysis)

  • 조경래;김성수;박종근;홍준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.509-512
    • /
    • 1995
  • The relaying algorithm to calculate the fault distance from only transient signal at faults in T/L is presented. In this paper. At faults the oscillation frequency components exist in both voltage and current and these components minimize the input impedance shown in fault point. The equivalent source impedance shown in relaying point is needed to calculate the fault distance using these components. To source impedance, the reflection coefficient between forward wave and backward and the Prony's analysis is also employed to extract the oscillation frequency component from transient signals. The case study show that the new distance relaying algorithm satisfies the high operation speed and high accuracy even if the algorithm uses only transient signals.

  • PDF

채널 길이와 전송 전력을 고려한 시변 환경 옥내 단일 사용자 전력선 통신의 outage 확률 분석 (Outage Probability Analysis under Time-varying characteristic of Indoor Single User PLC Considering Channel Length and Transmit Power)

  • 신재영;정지채
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.285-290
    • /
    • 2010
  • We investigate the outage probability in terms of QoS (quality of service) in indoor PLC network. We consider various kinds of appliances for realistic indoor PLC network. For estimation of the outage probability, we calculate the time-varying channel responses considering the loading conditions based on regular human activities and include the additive noise. We calculate the outage probability for each terminal and investigate relationship between the outage probability and the channel length, and transmit powers. Our results suggest that the outage probability is increased when the channel length becomes longer because more appliances affect the amount of reduced channel capacity and is not improved distinctly for very high and low outage threshold by increasing the transmit power. However, we can see outage probability improvement for 30% outage threshold case by increasing the transmit power.

순간전압강하 누적 테이블 및 밀도 테이블 계산을 위한 취약지역 결정 방법 (Method to Determine Areas of Vulnerability for Calculating Sag Cumulative Table and Sag Density Table)

  • 박창현;이한상
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.746-751
    • /
    • 2014
  • This paper presents a method to calculate a sag cumulative table and density table based on the area of vulnerability to voltage sags. The expected sag performance at sensitive load points can be easily assessed through the calculation of the sag cumulative table and density table. However, the calculation of the tables regarding large power systems is very difficult task. Therefore, an efficient method for calculating the tables is needed. In this paper, the improved method to determine the areas of vulnerability is addressed and the method to calculate the tables based on the area of vulnerability is also described. The proposed scheme can be efficiently used to assess the voltage sag performance at sensitive load points in large power systems.

개선된 고속월쉬변환에 의한 직교필터 설계 (The orthogonal filter design using improved fast Walsh transform)

  • 정제욱;조영호;이한석;박준훈;심재선;안두수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2620-2623
    • /
    • 2000
  • The standard approach consists of using correlation of orthogonal functions in digital filtering, such as well-known FFT(Fast Fourier Transform) and FWT(Fast Walsh Transform). But it needs much calculations, multiplications and additions. The calculation amount is m $log_2m$ in the general case. Therefore, this requires high speed processors to calculate in real time, which can calculate floating point. This study developed improved fast Walsh transform based on dyadic-ordered fast Walsh transform, then regenerated signal flow graph of improved fast Walsh transform, and used it for digital filtering, and then measured fundamental frequency and harmonics for current and voltage signals of power system.

  • PDF

확률론적 조류계산을 이용한 송전 신뢰도 여유 계산 (Calculate Transmission Reliability Margin using Probabilistic Load Flow)

  • 신동준;김진오;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.569-571
    • /
    • 2003
  • As a definition of NERC, Available Transfer Capability(ATC) is a measure of the transfer capability remaining in the physical transmission network for the future commercial activity. To calculate ATC, accurate and defensible TTC, CBM and TRM should be calculated in advance. In this paper, we propose a method to quantify TRM using probabilistic load flow based on the method of moment. Generation output, bus voltages, loads, and line outages are considered as complex random variables (CRV) to take into account for uncertainties related to the transmission network conditions. Probability Density Function (PDF) of line flow at the most limiting line is used to quantify TRM with the desired probabilistic margin. Suggested method is compared with the results from conventional CPF method and verified using 24 bus MRTS, and the suggested method based on PLF shows efficiency and flexibility for the quantification of TRM compared with the conventional method.

  • PDF

Reliability analysis of shallow tunnel with surface settlement

  • Yang, X.L.;Li, W.T.
    • Geomechanics and Engineering
    • /
    • 제12권2호
    • /
    • pp.313-326
    • /
    • 2017
  • Based on the reliability theory and limit analysis method, the roof stability of a shallow tunnel is investigated under the condition of surface settlement. Nonlinear Hoek-Brown failure criterion is adopted in the present analysis. With the consideration of surface settlement, the internal energy and external work are calculated. Equating the rate of energy dissipation to the external rate of work, the expression of support pressure is derived. With the help of variational approach, a performance function is proposed to reliability analysis. Improved response surface method is used to calculate the Hasofer-Lind reliability index and the failure probability. In order to assess the validity of the present results, Monte-Carlo simulation is performed to examine the correctness. Sensitivity analysis is used to estimate the influence of different variables on reliability index. Among random variables, the unit weight significantly affects the reliability index. It is found that the greater coefficient of variation of variables lead to the higher failure probability. On the basis of the discussions, the reliability-based design is achieved to calculate the required tunnel support pressure under different situations when the target reliability index is obtained.

Bridge-type structures analysis using RMP concept considering shear and bending flexibility

  • Hosseini-Tabatabaei, Mahmoud-Reza;Rezaiee-Pajand, Mohmmad;Mollaeinia, Mahmoud R.
    • Structural Engineering and Mechanics
    • /
    • 제74권2호
    • /
    • pp.189-199
    • /
    • 2020
  • Researchers have elaborated several accurate methods to calculate member-end rotations or moments, directly, for bridge-type structures. Recently, the concept of rotation and moment propagation (RMP) has been presented considering bending flexibility, only. Through which, in spite of moment distribution method, all joints are free resulting in rotation and moment emit throughout the structure similar to wave motion. This paper proposes a new set of closed-form equations to calculate member-end rotation or moment, directly, comprising both shear and bending flexibility. Furthermore, the authors program the algorithm of Timoshenko beam theory cooperated with the finite element. Several numerical examples, conducted on the procedures, show that the method is superior in not only the dominant algorithm but also the preciseness of results.