Effects of CellCaSi and Inorganic Additives on Phosphorus Removal in Water (규산질다공체와 무기첨가물의 수중 인 제거 효과)

  • Park, Myung-Hwan;Han, Myung-Soo;Lee, Seog-June;Ahn, Chi-Yong;Yoon, Byung-Dae;Oh, Hee-Mock
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.3 s.99
    • /
    • pp.213-219
    • /
    • 2002
  • The CellCaSi, a porous silicate material, was tested for the removal of phosphorus (P as phosphate) in water. The effect of the CellCaSi was investigated on the basis of both particle size (under 1,2, and 4 mm) and added amount (0, 1, 2.5, 5, and 10 g/1) of the CellCaSi. The removal efficiency of phosphorus was highest with a particle size of under 1 mm and also increased with an increasing amount of the CellCaSi. The pH change showed little effect on the phosphorus removal of the CellCaSi. The calcium ion was eluted from the CellCaSi into the water, while the aluminium and iron were not. The eluted calcium ion was combined with dissolved phosphorus and then precipitated. The highest removal efficiency of phosphorus was obtained by the combined addition of the CellCaSi, calcium chloride, and ferric chloride. That is, the phosphorus concentrations of 0.10 and 1.0 mg/1 decreased to 0.03 and 0.47 mg/l by the addition of the CellCaSi (1 g/l), calcium ion (30 mg/l), and ferric ion (1 mg/l) at day 8 after treatment. The water qualities at the end of the experiment were as follows: pH was 8.1 and conductivity was 318 ${\mu}$S/cm (a registered maximum conductivity of 500${\mu}$S/cm for raw and potable wafers).

Observations of Treatment Efficiency and Fouling in Submerged Membrane Filtration Treating High-Turbidity Source Water (고탁도 원수대응 침지식 멤브레인 여과에서 공기폭기 및 용액조성에 따른 파울링 및 처리효율 관찰)

  • Jang, Hoseok;Byun, Youngkwon;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.77-83
    • /
    • 2017
  • Transient behavior of fouling resistance was observed with a laboratory-scaled, submerged microfiltration membrane system treating high-turbidity source water consisting of inorganic silica particles and humic acid. Fouling mitigation efficiency with inorganic silica particles caused by aeration was reduced significantly as both humic acid and calcium ion existed together. Scanning electron microscopic observations showed that humic acid was adsorbed onto the surface of inorganic silica particles in the presence of calcium. Turbidity removal was achieved almost completely by submerged MF system regardless of feed compositions. However, the $UV_{254}$ removal of humic acid was improved in the presence of both calcium and inorganic silica particles. Additionally, increasing air-flow rate tended to increase $UV_{254}$ removal efficiency higher than 80%. This may be caused by back-transport of humic acid enhanced by inorganic silica particles providing surface for organic adsorption in the presence of calcium.

Transfer of Calcium along Trophic Levels on Limestone and Granitic Gneiss Grassland (석회암과 화강편마암 지역의 초지에서 영양단계별 칼슘 전이)

  • Yi, Hoon-Bok;Nam, Sang-Ho;Kim, Joon-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.3
    • /
    • pp.228-238
    • /
    • 2007
  • Calcium plays an important role for the organisms' physiology, reproduction, and growth. Calcium amount and transfer efficiency along trophic levels were compared at two different geological areas, Limestone area (LS) and Granitic Gneiss area (GG) in 1992 and 1993. Biomass and calcium amount of plants, herbivores and carnivores were seasonally measured. The removal sweeping net method was used to collect the quantitative insect samples. Calcium content (mgCa $g^{-1}$ DM) and pH of soil were 4.85 and 7.3 at LS and 0.21 and 7.3 at GG. The calcium transfer efficiencies (%) at LS and CG were 0.2 and 4.2 from soil to plants, 0.002 and 0.02 from plants to herbivores, and 73 and 47 from herbivores to carnivores, respectively. As a whole, the high calcium content of the LS soil reduced the utilization of calcium by plants. The higher trophical levels were, the higher ecological efficiency of the biological levels was. The calcium transfer amount was higher at LS, but its efficiency was rather higher at GG.

A STUDY ON THE SHEAR BOND STRENGTH OF LUTING GLASS IONOMER AND DENTIN TREATED WITH CALCIUM SOLUTION (칼슘수용액으로 처리한 상아질과 합착용 글래스아이오노머의 전단결합강도에 관한 연구)

  • Paik, Young-Girl;Lee, Sung-Bok;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.593-610
    • /
    • 1996
  • The objective of this paper was to evaluate the shear bond strength of luting glass ionomer cement with defferent calcium based solution treatment on dentin surface. 120 extracted human teeth were classified into 12 group based on presence of smear layer on dentin surface and type of treatment solution. Smear layer remove on dentin surface was done using 6% citric acid for 60 seconds. Five different dentin surface treatment solutions(calcium acetate, calcium carbonate, clacium chlorided, calcium hydroxide, and calcium phosphate) were evaluated in this study. After surface modification, metal ring(inner diameter : 3mm, depth : 1mm) was placed to expose the same dentin surface area and inner space was filled with luting glass ionomer cement according to the recommended procedure for stadard clinical procedure. The shear bond strength of glass ionomer cement was determined after 24 hours. SEM was used for the evaluation of the surface morphologic changes and EDAX analysis was done for determination of the change of the calcium contents of treated dentin. Follwing conclusion can be drawn : 1. In the group of the dentin surface with smear layer, the calcium carbonate solution was the most effective for the increase of the clacium content and the shear bond strength of glass ionomer cement to dentin surfaces. 2. In the group of the calcium carbonate treated dentin with msear layer, the shear bond strength was increased twice compared to the control group and cohesive failure mode was observed. 3. The shear bond strength of cement was increased significantly be the removal of smear layer using 6% citric aicd. However, additional calcium solution treatments were not effective for further bond strength increase. 4. The shear bond strength of cement was significantly improved by both of the removal of smear layer and the calcium solution treatment, and the former was more effective for bond strength improvement. 5. The smear layer removed/calcium solution treated groups showed dentinal tubule obstruction and crystal attachment in SEM evaluation. However, the shear bond strengths of these groups were not increased compared to the smear layer removed/no dentin treatment group.

  • PDF

Microbial Removal Using Layered Double Hydroxides and Iron (Hydr)oxides Immobilized on Granular Media

  • Park, Jeong-Ann;Lee, Chang-Gu;Park, Seong-Jik;Kim, Jae-Hyeon;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.149-156
    • /
    • 2010
  • The objective of this study was to investigate microbial removal using layered double hydroxides (LDHs) and iron (hydr)oxides (IHs) immobilized onto granular media. Column experiments were performed using calcium alginate beads (CA beads), LDHs entrapped in CA beads (LDH beads), quartz sand (QS), iron hydroxide-coated sand (IHCS) and hematite-coated sand (HCS). Microbial breakthrough curves were obtained by monitoring the effluent, with the percentage of microbial removal and collector efficiency then quantified from these curves. The results showed that the LDH beads were ineffective for the removal of the negatively-charged microbes (27.7% at 1 mM solution), even though the positively-charged LDHs were contained on the beads. The above could be related to the immobilization method, where LDH powders were immobilized inside CA beads with nano-sized pores (about 10 nm); therefore, micro-sized microbes (E. coli = 1.21 ${\mu}m$) could not diffuse through the pores to come into contact with the LDHs in the beads, but adhere only to the exterior surface of the beads via polymeric interaction. IHCS was the most effective in the microbial removal (86.0% at 1 mM solution), which could be attributed to the iron hydroxide coated onto the exterior surface of QS had a positive surface charge and, therefore, effectively attracted the negatively-charged microbes via electrostatic interactions. Meanwhile, HCS was far less effective (35.6% at 1 mM solution) than IHCS because the hematite coated onto the external surface of QS is a crystallized iron oxide with a negative surface charge. This study has helped to improve our knowledge on the potential application of functional granular media for microbial removal.

Treatment of Fluoride in Semiconductor Wastewater by using Fluidized Bed Reactor (유동상 반응기를 이용한 반도체 폐수의 불소 처리)

  • An, Myeong-Ki;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.437-442
    • /
    • 2010
  • This work was initiated both to maximize purity of calcium fluoride sludge and to minimize water content in the settled sludge. The sludge was produced in the process of fluoride removal of semiconductor wastewater by the addition of $Ca^{2+}$ ion. Fludized bed reactor(FBR) using calcium fluoride as a seed was adapted. Optimum pH and molar ratio of $Ca^{2+}/F^-$ were determined in lab-scale study. The experimental results showed that fluoride removal was increased as pH and molar ratio of $Ca^{2+}/F^-$ increased, with the best removal of 79.8% in an optimum condition. In the optimum point of fluoride removal, very low ${PO_4}^{3-}$-P removal of 9.3% was observed. It indicates forming $CaF_2$ crystal of high purity, when side reaction of calcium with phosphate was minimized. In addition, water content of settled sludge was 19.3%, which is relatively low compared to other fluoride removal processes. Consequently, the FBR process proposed in this study was very effective in fluoride removal, producing good sludge of high purity and less water content.

Effects of Salts on the Formation of $\alpha$-Calcium Sulfate Hemihydrated from by-Product Gypsum of Phosphoric Acid Process at Hydrothermal Condition (가압수열 수용액중에서 인산석고로부터 $\alpha$형 반수석고의 생성에 미치는 염류의 영향)

  • 이구종;최상흘
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.4
    • /
    • pp.343-348
    • /
    • 1987
  • The effects of salts such as aluminum sulfate as inorganic salt(2-4%), and sodium salts of citrate, tartrate, succinate, potassium tartrate and gelatin as organic salts(0.1%) on the formation of ${\alpha}$-calcium sulfate hemihydrate from by-product gypsum of phosphoric acid process under hydrothermal condition at 123$^{\circ}C$ and 133$^{\circ}C$ were investigated. Aluminum sulfate solution exhibited the catalystic effected on the crystallization of ${\alpha}$-calcium sulfate hemihydrate of which was assumed in the prismatic form, and organic salts solution exhibited little effect on the catalystic action to the crystallization, than inorganic salts. In the acidic solution with sulfuric acid(pH=2), needle like crystal of calcium sulfate hemihydrate was obtained. Hydrothermal process with aluminum sulfate solution also showed certain amounts of impurity removal such as phosphorus penataoxide from calcium sulfate hemihydrate.

  • PDF

Treatment Features of Fluorine-containing Wastewater Using Calcium as a Precipitant for Its Reuse (처리수(處理水) 재사용(再使用)을 위한 칼슘 침전법(沈澱法)에 의한 불소폐수(弗素廢水) 처리(處理) 특성(特性))

  • Kim, Young-Im;Baek, Mi-Hwa;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.16 no.4
    • /
    • pp.27-32
    • /
    • 2007
  • The characteristics of fluorine removal from wastewater have been investigated by precipitation method using calcium as a precipitant for the purpose of the reuse of treated wastewater. In the conditions of 10 mM of the initial concentration of fluorine and pH 4, the precipitation of fluorine was rapidly progressed within a few minutes after the precipitant was added and the precipitation of fluorine was observed to follow a second order reaction. Also, as the addition of precipitant was increased, the reaction rate constant of fluorine precipitation was found to rise. Postulating that the maximum fluorine removal was attained at pH 4, about 70% of fluorine was precipitated compared with the maximum removal when 10 times of equivalent amount of calcium was employed at pH 2 and the fluorine removal was about 96% compared with its maximum value at pH 3 under the same addition of precipitant. The fluorine precipitation reaction was found to be endothermic and the coexistence of $SiF_6{^{2-}}$ with fluorine resulted in its less removal. Finally, the isoelectric point of the precipitate was examined to be ca. pH 5.

Effect of Ovariectomy and Dietary Calcium Levels on Bone Metabolism in Rats Fed Low Calcium Diet during Growing Period (성장기 동안 저칼슘식이를 섭취한 흰쥐에서 난소절제 및 칼슘 섭취량이 골격대사에 미치는영향)

  • 이연숙
    • Journal of Nutrition and Health
    • /
    • v.31 no.3
    • /
    • pp.279-288
    • /
    • 1998
  • This study explored the effect of calcium levels and/or ovariectomy on bone metabolism using female Sprague-Dawley weanling rats as a model . Rats received a low (0.1%) calcium diet for 8 weeks. The rats were then divided into three subgroups that were fed 0.1% ,0.5% and 1.5% calcium diets for 8 weeks after operation. The results of this experiment indicate that body weight gin was higher in ovariectomy groups than in sham groups regardless of calcium level and food intake. Serum Ca and P concentrations were of normal level regardless of calcium level and ovariectomy. Estrogen concentration was low in the ovariectomized group. Serum alkaline phophatase activity and urinary hydroxyproline have been used as markers of bone formation and resorption. These values were increased in ovariectomized groups. The weight, length and breaking force of femur were not significantly different between the groups. Ash, Ca, P and total lipid contents in femur and lumbar were decreased in the groups fed low calcium . Mg content was decreased in the ovariectomy and total protein content was not affected by calcium level and ovariectomy. The effect groups of ovarectomy on calcium contents of bone was more prominent in lumbar than in femur. In conclusion, though low calcium intakes during growth period may retard the attainment of peak bone mass, calcium supplementation after this period increased bone growth and mineral contents, but not significant effect in three calcium levels. Furthermore, calcium intake was shown to have a greater influence on the mineral contents of femur than of lumbar, and removal of endogenous estrogen production by ovariectomy was shown to be more deleterious on the ash and calcium contents of the lumbar than of femur.

  • PDF

HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS (임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구)

  • Lee, Sang-Chul;Song, Woo-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF