• 제목/요약/키워드: Cadmium Electrode

검색결과 40건 처리시간 0.021초

INVESTIGATION OF "STEPPED" DISCHARGE CURVES IN SINTERED TYPE NICKEL-CADMIUM CELL

  • SASAKI, Y.;YAMASHITA, T.
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.360-362
    • /
    • 1999
  • Formation of the nickel-cadmium alloy in the negative electrode of nickel-cadmium cell subjected to continuous charging at elevated temperatures ($40~45^{\circ}C$) is shown to be one of the causes of the 'stepped' discharge curves. The alloy has been characterized by electrode potential measurement and X-ray diffraction method. The potential lowering during discharge is related to discharge of the alloy. X -ray diffraction suggests that the nickel-cadmium alloy can be formed during charge in negative electrode by interaction of the two metals. Addition of Ni $(OH)_2$ into $Cd{\;}(OH)_2$ active material is found to form the alloy more readily than sintered negative electrode alone.ode alone.

  • PDF

알칼리 축전지의 활물질에 관한 연구. 카드뮴 전극에 관하여 (Studies on the Active Materials of Alkaline Storage Battery. On Cadmium Electrode)

  • 이주성;주충렬;박수길
    • 대한화학회지
    • /
    • 제25권5호
    • /
    • pp.325-330
    • /
    • 1981
  • Ni-Cd 전지 중 카드뮴 전극을 수산화 칼륨용액 중에서 각종 조건의 변화에 따른 cyclic voltammetry를 행하여 카드뮴전극의 전기화학적 거동을 검토하였으며 voltammogram에 나타나는 peak전위 근처의 각 전위에서 정전위 전해를 하여 충, 방전상태의 전기화학적 거동을 X-선 회절선도의 해석 결과와 결부시켜 전극반응 메카니즘을 종합적으로 검토하였다. 수산화카드뮴 마이너스 전극의 음극분극 곡선에는 두 개의 peak가 나타난다. 마이너스극의 수산화카드뮴은 제 1 peak 전위에서 카드뮴 금속으로 환원되고 제 2 peak 전위에 도달하면 매우 활성이 큰 금속 상태로 되며 (002)면이 (101)면보다 성장이 매우 크다. 또한 제 2 peak 전위의 카드뮴은 산소와의 선택적인 반응이 급속히 일어남을 알 수 있었다. 본 실험의 결과 카드뮴극과 산소와의 반응은 화학적 반응인 $2Cd + O_2 + 2H_2O\;{\longrightarrow}\;2Cd(OH)_2$으로 진행된다고 추정하였다.

  • PDF

Simultaneous Removal of Cadmium and Copper from a Binary Solution by Cathodic Deposition Using a Spiral-Wound Woven Wire Meshes Packed Bed Rotating Cylinder Electrode

  • Al-Saady, Fouad A.A.;Abbar, Ali H.
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.58-66
    • /
    • 2021
  • Spiral-wound woven wire meshes packed bed rotating cylinder electrode was used for the simultaneous removal of cadmium (Cd) and copper (Cu) from a binary solution. The effects of weight percent of each metal on the removal and current efficiencies were studied at an operating current of 345A, while the effect of current on the removal efficiency of both metals was investigated at three levels of current (240, 345.and 400 mA). The experiments were carried out at constant rotation speed 800 rpm, pH = 3, and a total concentration of metals (500 ppm). The results showed that the removal efficiency of copper increased from 89% to 99.4% as its weight percent increased from 20% to100%. In a similar fashion, the removal efficiency of cadmium increased from 81% to 97% as its weight percent increased from 20% to100%. The results confirmed that the removal efficiency of any metals declined in the presence of the other. Increasing of current resulted in increasing the removal efficiency of both metals at different weight percents. The results confirmed that current efficiencies for removing of copper and cadmium simultaneously decline with increasing of electrolysis time and weight percent of cadmium or with decreasing the weight percent of copper. Current efficiency was higher at the initial stage of electrolysis for all weight percents of metals. The results showed that the decay of copper concentration was exponential at all weight percents of copper, confirming that the electrodeposition of copper is under mass transfer control in the presence of cadmium. While the decay of cadmium concentration was linear at lower weight percent of cadmium then changed to an exponential behavior at high weight percent of cadmium in the presence of copper.

Nafion-Ethylenediamine이 수식된 유리탄소전극에 의한 Cd(II) 이온의 정량 (Determination of Cadmium(II) Ion Using the Nafion-Ethylenediamine-Modified Glassy Carbon Electrode)

  • 김진아;고영춘;박찬주;박병호;정근호
    • 분석과학
    • /
    • 제14권2호
    • /
    • pp.123-130
    • /
    • 2001
  • Perfluorinated sulfonated polymer-ethylenediamine(Nafion-en)이 화학수식된 유리탄소전극을 사용하여 Cd(II) 이온의 정량에 대해 연구하였다. Cd(II) 이온의 착화제인 ethylenediamine(en)을 nafion에 고정시켜 유리탄소전극 표면에 수식하면 이 수식전극의 en은 Cd(II) 이온과 $[Cd(en)_2]^{2+}$의 착물을 형성한다. Nafion-en이 화학수식된 유리탄소전극에서 시차펄스전압전류법에 의한 Cd(II) 이온의 환원봉우리전위는 $-0.780({\pm}0.005)V$(vs. Ag/AgCl), 측정범위는 $5.0{\times}10^{-7}-2.0{\times}10^{-5}M$, 검출한계(3s)는 $2.20{\times}10^{-7}M$이었다. Nafion-en이 화학수식된 유리탄소전극의 검출한계가 수식되지 않은 유리탄소전극에 비해 약 14배 정도 향상되었다.

  • PDF

카드뮴과 납 전기화학적 검출을 위한 전극선정에 관한 연구 (Study on Electrode Selection for Electrochemical Detection of Cadmium and Lead)

  • 김학진;김기영;모창연;조한근
    • Journal of Biosystems Engineering
    • /
    • 제33권6호
    • /
    • pp.404-409
    • /
    • 2008
  • Excessive presence of heavy metals in environment affects plants and fruits grown in the contaminated area. Rapid on-site monitoring of heavy metals can provide useful information for efficiently characterizing heavy metal-contaminated sites and for minimizing the exposure of the contaminated food crops to humans. This study reports on the evaluation of gold and glassy carbon (GC) electrodes with mercury or bismuth as a coating material for simultaneous determination of cadmium (Cd) and lead (Pb) in 0.1 M $HNO_3$ solution by anodic stripping voltammetry (ASV). The use of a square-wave voltammetric potential between a working electrode and a reference electrode caused Cd and Pb ions deposited on the electrode surface to be oxidized, thereby generating electric currents at different potentials. The mercury-coated gold electrode was not sensitive enough to detect the usable range of Cd concentrations (1 to 100 ppb). The GC electrodes with mercury or bismuth displayed well-defined, sharp and separate current peaks for Cd and Pb ions when the square-wave voltammetric potentials were applied. The peak currents measured with both mercury- and bismuth- coated GC electrodes were linearly proportional to Cd and Pb concentrations in the range of 1 to 200 ppb in 0.1 M $HNO_3$ with strong linear relationships between concentration and peak current ($R^2$ > 0.95), indicating that both of Cd and Pb ions could be quantitatively measured.

양극벗김전위법 비스무스막 유리탄소전극을 이용한 표준 쌀 분말 내 카드뮴과 납 측정 (Using a Bismuth-film Glassy Carbon Electrode Based on Anodic Stripping Voltammetry to Determine Cadmium and Lead in a Standard Rice Flour)

  • 김학진;손동욱;모창연;한재웅;김기영;박상원;엄애선
    • Journal of Biosystems Engineering
    • /
    • 제34권5호
    • /
    • pp.377-381
    • /
    • 2009
  • Excessive presence of heavy metals in environment may contaminate plants and fruits grown in that area. Rapid on-site monitoring of heavy metals can provide useful information to efficiently characterize heavy metal-contaminated sites and minimize the exposure of the contaminated food crops to humans. This study reports on the evaluation of a bismuth-coated glassy carbon electrode for simultaneous determination of cadmium (Cd) and lead (Pb) in a NIST-SRM 1568a rice flour by anodic stripping voltammetry (ASV). The use of a supporting electrolyte 0.1 M $HNO_3$ at a dilution ratio (sample pretreated with acid digestion in a microwave oven: supporting electrolyte) of 1:1 provided well-defined, sharp and separate peaks for Cd and Pb ions, thereby resulting in strongly linear relationships between Cd and Pb concentrations and peak currents measured with the electrode ($R^2\;=\;0.97$, 0.99 for Cd and Pb, respectively). The validation test results for spiked standard solutions with different concentrations of Cd and Pb gave acceptable predictability for both spiked Cd and Pb ions with mean prediction errors of 6 to 30%. However, the applicability of the electrode to the real rice flour sample was limited by the fact that Cd concentrations spiked in the rice flour sample were overly estimated with relatively high variations even though Pb ion could be quantitatively measured with the electrode.

이온치환 반응을 이용한 니켈-카드뮴 폐이차전지에서 카드뮴의 분리에 대한 연구 (A Study on the Separation of Cadmium from Waste Ni-Cd Secondary Batteries by Ion Substitution Reaction)

  • 김대원;박일정;안낙균;정항철;정수훈;최중엽;양대훈
    • 자원리싸이클링
    • /
    • 제27권4호
    • /
    • pp.36-43
    • /
    • 2018
  • 폐 니켈-카드뮴 전지의 재활용을 위하여 효율적으로 카드뮴과 니켈을 분리할 수 있도록 이온치환 반응을 이용하여 선택적으로 카드뮴을 분리하였다. 폐 니켈-카드뮴 전지 내의 전극을 분쇄하여 얻은 전극 분말을 황산에 침출시킨 니켈-카드뮴 용액에 황화나트륨을 첨가하여 CdS로 침전시켰다. 다양한 조건에서 이온치환실험을 실시하였으며, 최적조건으로는 상온에서 용액의 pH = -0.1, $Na_2S/Cd=2.3$일 때 용액 내 잔존하는 Cd은 약 100 ppm으로 대부분 CdS로 침전된 결과를 얻을 수 있었다.

비스무스 나노분말 표지 전극의 카드뮴/납 검출특성에 관한 연구 (A Study on Detection Characteristics of Cadmium and Lead for Bi Nanopowder-Labeled Electrode)

  • 이경자;김현진;이희민;이상훈;이민구;이창규
    • 한국분말재료학회지
    • /
    • 제15권5호
    • /
    • pp.393-398
    • /
    • 2008
  • Trace analysis of Cd and Pb at surface modified thick film graphite electrode with Bi nanopowder has been carried out using square-wave anodic stripping voltammetry (SWASV) technique. Bi nanopowder synthesized by gas condensation (GC) method showed the size of $50{\sim}100$ nm with BET surface area, $A_{BET}=6.8m^{2}g^{-l}$. For a strong adhesion of the Bi nanopowder onto the screen printed carbon paste electrode, nafion solution was added into Bi-containing suspension. From the SWASV, it was found that the Bi nanopowder electrode exhibited a well-defined responses relating to the oxidations of Cd and Pb. The current peak intensity increased with increasing concentration of Cd and Pb. From the linear relationship between Cd/Pb concentrations and peak current, the sensitivity of the Bi nanopowder electrode was quantitatively estimated. The detection limit of the electrode was estimated to be $0.15{\mu}g/l$ and $0.07{\mu}g/l$ for Cd and Pb, respectively, on the basis of the signal-to-noise characteristics (S/N=3) of the response for the $1.0{\mu}g/l$ solution under a 10 min accumulation.

Toxic Effect of Cadmium Assay in Contaminated Soil Earthworm Cell Using Modified Sensor

  • Ly, Suw Young;Kyung, Lee;Kim, Chae Hwa;Seo, Roma;Lee, Soo Youn;Kim, Lina;Chae, Su min;Choi, Sung Wook;Kim, Ji Yoon
    • Toxicological Research
    • /
    • 제31권2호
    • /
    • pp.213-217
    • /
    • 2015
  • A voltammetric toxic metal of cadmium detection was studied using a fluorine doped graphite pencil electrode (FPE) in a seawater electrolyte. In this study, square wave (SW) stripping and chronoamerometry were used for determination of Cd(II) in seawater. Affordable pencils and an auxiliary electrode were used as reference. All experiments in this study could be performed at reasonable cost by using graphite pencil. The application was performed on the tissue of contaminated soil earthworm. The results show that the method can be applicable for vegetables and in vivo fluid or medicinal diagnosis.

카드뮴 전해석출에서의 이성분첨가물계의 효과 (The Effect of Some Binary Additive Systems in the Electrodeposition of Cadmium)

  • 이경호
    • 분석과학
    • /
    • 제9권2호
    • /
    • pp.161-167
    • /
    • 1996
  • 이성분계 첨가물을 이용한 카드뮴 석출과 수소 생성의 상대족인 속도를 조절할 수 있는 가능한 방법에 대하여 조사하였다. 수소를 발생하는 물의 전기환원을 억제하는 소수성 필름을 형성할 수 있는 벤질 알코올을 첨가제 중의 하나로 선택하였다. 다른 한 가지 첨가제는 카드뮴(II) 이온의 친수성을 약화시킴으로써 소수성 벤질 알코올 필름층을 쉽게 가로질러 환원극에 전착시킬 수 있는 것을 선택하였다. 전압 전류 효율 연구로부터 이온쌍과 착물 첨가제가 벤질 알코올 필름 존재하에서 카드뮴의 환원을 촉진시킬 수 있다는 것을 확인하였다. 벤질 알코올 필름은 나트륨 이온과 카드뮴의 염화착물을 형성하는 이온쌍을 얻기에 충분하도록 전극 주위의 유전상수를 낮추고, 카드뮴의 환원을 촉진시킨다. 이러한 환원의 촉진은 염화물이 존재하지 않는 황산염 용액에서는 일어나지 않는다. 왜냐하면 카드뮴은 본래 아쿠아 착물과 이온쌍으로 존재하여 카드뮴의 환원을 촉진시키지 못하고 환원을 방해시키기 때문이다.

  • PDF