• Title/Summary/Keyword: Cable sheath

Search Result 126, Processing Time 0.028 seconds

Improvement of Detailed Fault Point Decision Using EMTP Analysis of Search Coil Method for HVDC Cables (Search Coil법의 EMTP 분석을 통한 HVDC 케이블 상세 고장지점 판정 정확도 개선)

  • Jung, Chae-Kyun;Park, Jin-Woo;Yang, Byeong-Mo;Kang, Ji-Won;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1656-1662
    • /
    • 2011
  • In a previous paper, the EMTP modeling technique using search coil test is established through various transient analysis including system grounding condition and grounding resistance for HVDC submarine cables. It was also proved by comparison with real test results. Based on this EMTP modeling technique, in this paper, it will be applied for modeling of ${\pm}180kV$ real HVDC submarine system(Jeju~Haenam). This paper variously analyses the effects of fault resistance including the resistance between core and sheath, the resistance between sheath and amore and the resistance between amore and sea water through EMTP modeling of search coil method. The results can contribute to the accuracy of detailed fault point prediction of search coil test for HVDC submarine cables.

Ion Permeation in Compounds for the Power Cable Sheath (배전케이블 외피용 컴파운드의 이온투과 특성)

  • Kim, Dong-Myung;Park, Kwang-Seok;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.864-865
    • /
    • 1998
  • Permeation of $Ca^{2+}$ ions in PVC and flame-retardant polyolefin (FR) compounds for the sheath of medium voltage underground cables was studied. At $70^{\circ}C$ ion permeation increases fast at times of up to a few tens of hour and then at a relatively slow rate. The first fast increase was attributed to the diffusion of ions in the samples while the second slow increase of ion permeation was attributed to the permeation of $Ca^{2+}$ ions through the samples. It was also found that the diffusivity of $Ca^{2+}$ ions in FR compounds is much higher than that in PVC compounds.

  • PDF

Development of Distance Relay Algorithm Using ACI Technique on Underground Power Cable System (ACI 기법을 이용한 지중송전계통 거리계전알고리즘 개발)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Roh, Seok-Beom;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.676-678
    • /
    • 2005
  • In underground power cable system, the apparent impedance at the relaying point can be changed because of the complicated configuration such as the various earth resistance and the operation of sheath voltage limiter (SVL). They have a bad effect on the distance relay operation Therefore, in this paper, in order to solve this problem, the authors are going to anly the advanced computational technique(ACI) of FR-FIS(Fuzzy Relation-based Fuzzy Inference System).

  • PDF

Phenomenon of Power Interference and Screening Factor (전력유도 현상과 차폐계수)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Lee, Kyoung-Wook;Kim, Jae-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

Evaluation of Distance Relay Operation Characteristic with the Reduction Devices Installed in Underground Power Cable Systems (시스순환전류 저감장치 설치시 거리계전기 응동 특성 평가)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.494-496
    • /
    • 2003
  • This paper analyses the operation characteristic of distance relay when the single line to ground occurs in underground power cable systems that reduction device of sheath circulating current is installed. To apply that reduction device to actual system, the change of line impedance calculated at relay point is also analysed by the connection type of SVLs and fault location, fault inception angle with the installation of reduction device of reactor or not.

  • PDF

A fault location algorithm for underground cable by Distributed Parameter Circuit Analysis (분포정수회로 해석을 통한 지중케이블 고장거리 알고리즘 연구)

  • Yang, Xia;Bae, Y.J.;Choi, M.S.;Lee, S.J.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.171-173
    • /
    • 2003
  • This paper presents a new fault location algorithm for 3 phase underground cable based on distributed parameter circuit analysis, by which we establish the basic equations for each of core and sheath currents and voltages considering cross-bonding sheaths. The proposed algorithm need simulate by EMTP, and then the EMTP data need be compared with the calculation result in Matlab.

  • PDF

A Study on the Flame Retardancy According to the Aging of Power Cables (전력케이블의 경년열화에 따른 난연성에 관한 연구)

  • Lee, Hae-Pyeong;Kim, Hae-Rim;Park, Young-Ju;Song, Sa-Keum
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.358-361
    • /
    • 2010
  • 본 연구에서는 공동지하구 내에서 고온다습하고 유해가스 등 밀폐된 환경에서 사용되었던 CV-Cable을 대상으로 예상되는 Cable sheath 열화기간을 사용기간별(G전선 29년, L전선 14년, L전선 10년)로 3단계로 구분하여 콘칼로리미터와 UL 94 분석장비 등을 활용하여 착화시간, 총발열량, 연소속도를 측정함으로써 전력케이블의 경년열화에 따른 난연성을 비교분석하였다.

  • PDF

Switching Surge Analysis of Underground Transmission Systems (지중송전시스템의 스위칭서지 해석)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Jang, Sung-Hwan;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.481-483
    • /
    • 2002
  • In this paper, for continuously changed closing time of circuit breakers, switching overvoltage on 345kV underground transmission systems are variously analyzed using EMTP with statistical analysis method. And, switching overvoltage and closing surge occurred in conductors at sending and receiving end and metal sheath with variation of cable length are analyzed, and the reduction effects for switching overvoltage considered preinsertion resistance of circuit breakers are examined.

  • PDF

The Effects of Multi-Bonding Methods for Cable Covering Protection Unit (방식층 보호장치 결선방식의 혼용에 따른 영향분석)

  • Kim, Jeong-Nyeon;Ha, Che-Ung;Lee, Su-Gil
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.10
    • /
    • pp.489-492
    • /
    • 2001
  • The connection method of CCPU has been changed from connection between sheath and grounding to connection between sheaths without grounding since 1997. In domestic, there is so many cases that cables circuits were installed before 1997, added in same route after that, operated as multi-connecting systems of CCPU in same route. This paper examine the problem of multi-connecting system by EMTP simulation, and presents methods to improve the system characteristics.

  • PDF

Design of Measuring System for Insulation Resistance and Humidity in High-Power XLPE Cables in Operation and the Relationship Between Insulation Resistance and Humidity in the Oversheath (운전 중인 고전력 XLPE 케이블의 절연저항과 습도의 측정 시스템 설계 및 방식층 절연저항과 습도의 상관관계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.179-184
    • /
    • 2016
  • The usual way used by electric power stations to deliver high levels of generated power is via 6.6kV XLPE (or CV) cables. Depending on the manufacturing technique, installation environment, and usage conditions, the deterioration processes of the power cables start from the instant of operation. Cable junctions may break down in three years from the start of operation due to the manufacturing or construction defects. Otherwise they should be in good working order for 20-30 years. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to the dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables at Korean Western Power Co. Ltd. located in Taean, Chungcheongnam-do province. In this paper, we introduce the device hardware. Using the device, we have measured the insulation resistance and humidity in the sheath of the cables. We present, in analysed results, the effect of humidity on insulation resistance in cable sheaths.