• Title/Summary/Keyword: Cable head

Search Result 43, Processing Time 0.031 seconds

Analysis on Lightning Overvoltage According to Lead Length of Surge Arrester for Underground Cable Outdoor Termination Protection at C/H Tower (C/H 철탑 종단접속함 보호용 피뢰기 리드선 길이에 따른 뇌과전압 분석)

  • Jung, Chae-Kyun;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.257-263
    • /
    • 2016
  • This paper describes the lightning arrester transients in cable head termination. The installation references of cable head tower and lightning arresters are firstly reviewed, then the performance of lightning arrester operation is also evaluated based on lightning overvoltage analysis by the change of grounding lead cable length. This paper finally proposes the optimal length of grounding lead cable at the cable head termination. The limited lightning current is also proposed according to the change of grounding lead cable length. The results will contribute to protecting insulation breakdown failure against lightning surge at the terminations and joints.

TAPERED TUBULAR STEEL POLE FOR CABLE HEAD (케이블헤드 설치용 관형지지물)

  • Park, Tae-Dong;Kwon, Hyeog-Mun
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.158-160
    • /
    • 1997
  • WHEN IT IS REQUIRED TO CONNECT OVERHEAD TRANSMISSION LINE WITH UNDERGROUND CABLE, PREVALENT METHOD WAS TO USE CABLE HEAD TYPICALLY MADE OF LATTICE STEEL STRUCTURE. BUT IN VIEW OF THE INCREASING DEMAND THAT STEEL STRUCTURE INSTALLED IN URBAN AREA AND/OR RESIDENTIAL AREA NEED TO MATCH WITH ENVIRONMENTAL SURROUNDINGS, THE UNSHAPELY LARGE-SIZED LATTICE STEEL STRUCTURE CAN NOT BE A PROPER ONE BECAUSE THAT IT IS NOT WELCOMED BY THE RESIDENTS AND ACCORDINGLY ITS INSTALLATION TENDS TO CONFRONT WITH CIVIL PETITION. AS AN ALTERNATIVE METHOD TO SETTLE AFOREMENTIONED UNFAVOURABLE SITUATION WE MAY BE UNDER, WE AR INTENDING TO DEVELOP THE CABLE HEAD MADE OF TAPERED TUBULAR STEEL POLE AND TO PUT IT TO PRACTICAL USE. THE ADVANTAGE WE CAN TAKE OF THE TAPERED TUBULAR STEEL POLE IS THAT IT CAN BE INSTALLED IN A VERY LIMITED SPACE MAXIMIZING THE UTILITY VALUE OF THE LAND AND THAT ITS SMART SHAPE WITH COLOUR COATING IN CONSIDERATION OF AESTHETIC AESTHETIC CAN BE IN GOOD HARMONY WITH THE SURROUNDINGS.

  • PDF

Performance Test of a R134a Centrifugal Water Chiller

  • Jeong, Jin-Hee;Yoon, Pil-Hyun;Kim, Ghil-Yeung;Lee, Hyeon-Koo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.97-105
    • /
    • 2002
  • A centrifugal water chiller using alternative refrigerant R134a has been developed. The prototype was designed to have refrigerating capacity of 300RT. Its compressor employs a single high-speed impeller, airfoil diffuser and collector. Newly developed, enhanced tubes were installed in the evaporator and the condenser to reduce the required head for the compressor. Off-design characteristics at various conditions, performance test of the compressor and analysis of the refrigeration cycle were performed. So the probability of use in part load condition was checked and the direction for revision was suggested.

An Installation of 154kV XLPE CABLE in Steep Slope Condition (고낙차 조건에서의 154kV XLPE CABLE 설치)

  • Hwang, Soon-Chul;Lee, Chang-Su;Lee, Cheon-Ku;Goh, Chang-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.775-778
    • /
    • 1992
  • In 1980, 154kV OF cable was installed at the Cheong-Pyeong pumped-storage power station. Effective head of this pumped-storage station is 250m between upper and lower re-servior and length of cable route is 750m. However, several failures have happened owing to steep slope during the operation. 154 kV XLPE cable was applied for this power station to eliminate a lack of stability on account of steep slope and successfully installed in 1991. Meanwhile, installation procedure brings about many problem to be solved. In this paper, we describe the counter measure of cable sliding phenomena caused by heat shrinkage as well as the method of installation of cable under the steep slope condition. And hereafter, we think this paper will be a good reference to design and installation of 154kV XLPE cables in steep slope turnnel at urban areas.

  • PDF

Evaluation of Insulation Characteristics of EHV XLPE Power Cable (초고압 XLPE 전력케이블의 절연특성평가(I))

  • Jeong, K.H.;Baeg, I.J.;Lee, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1617-1619
    • /
    • 1998
  • In the nation, 154kV XLPE cable with an insulation thickness of 23mm have been used for transmission lines. The thickness is designed by old parameters which were determined by Kreuger, Oudin et al. in 1960s. By the way, the manufacturing technology has been developed. Especially in extruding and curing process we are using a triple common extruding head and applying gas-curing process. It allows the quality of XLPE cable improved. The paper evaluates the AC minimum insulation breakdown strength of XLPE power cable using model table. We can verify the uplifted insulation quality. And we expects the cable insulation thickness to be reduced applying the new parameter to the cable insulation design.

  • PDF

Dynamic analysis of ROV cable considering the coupling motion of ROV cable systems

  • Cho, Kyu Nam;Song, Ha Cheol;Hong, Do Chun
    • Structural Engineering and Mechanics
    • /
    • v.18 no.4
    • /
    • pp.429-440
    • /
    • 2004
  • Remotely Operated Vehicle of 6000-meters is a new conceptual equipment made to replace the manned systems for investigating the deep-sea environment, and all of the ROV systems in operational condition strongly depend on the connecting cables. In this point of view dynamics of the ROV cable system is very important for operational and safety aspects as a cable generally encounters great tension. Researches have been executed on this problem, and most of papers have been mainly focused on the operational condition of ROV system in deep sea. This paper presents the dynamic cable response analysis during ROV launching condition rather than the operational one in order to provide the design guide of a ROV cable system in this circumstance, considering the coupling effects between cable and wave-induced ship motion. To obtain the variations of cable tensions during a ROV launching, a pre-stressed harmonic response analysis was carried out. Wave-induced tensions of the cable during ROV launching were obtained in real sea states using FE modeling, and the basic design guide of a ROV cable system was obtained.

A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line (혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향)

  • Jeon, Yong-Joo;Jeon, Myung-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

A Study on Overvoltage Reduction Method of Single Point Bonded Section on Combined Transmission Lines (혼합송전선로 편단접지 구간 과전압 저감 방안에 관한 연구)

  • Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok;Kim, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1881-1887
    • /
    • 2009
  • This paper discusses the effects of ECC (Earth Continuity Conductor) for reducing the level of induced sheath overvoltages at the single point bonded section of combined transmission lines which are mixed underground power cable with overhead line in one T/L. In previous papers, the characteristics of ECC on only underground power cable systems were sufficiently analyzed. However, the result of only underground power cable systems are totally different from that of combined transmission lines because ECC is commonly grounded with overhead grounding wire at mesh of cable head. Therefore, in this paper, the installation effects of ECC have been variously analyzed considering the three kinds of fault positions, cable formation of duct and trefoil, spacing between phase conductor and ECC, and the change of overhead transmission line section length on 154kV combined transmission line. Finally, simulation results show that ECC can effectively reduce the induced sheath voltage.

A Mountain Head Lamp Applied for Loupes-assisted Microsurgery (루뻬 미세수술에 있어서 등산용 헤드램프의 활용)

  • Yun, Byung-Min;Han, Kyu-Nam;Kim, Suk-Wha
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.48-50
    • /
    • 2008
  • Loupes-assisted microsurgery often needs an operational head lamp for a better condition of light. This may cause serious neck fatigue due to the weight the operational head lamp, the limitation of the operator's head movement from the hind cable, and some cost for purchasing and management of it. On the contrary, a mountain head lamp is very light, full of freedom in movement, applicable to all types of loupes, and relatively very cheap. In conclusion, a mountain head lame can be a cost-effective light source for Loupes-assisted microsurgery.

  • PDF